You are on page 1of 16

Part Detail

Part Detail
Please see the details of the part you have configured. Note that Carling reserves the right to change
product details and specification without prior notice.

Catalog Number
VED2160B-G6CMV-0MZ

Specifications
Part Number: VED2160B-G6CMV-0MZ
CONTURA V ROCKER SWITCH SERIES
TRIPLE THROW ON-ON-ON
RATING: 20A 12V
10 TERM BASE: .250" TABS; NO BARRIERS ON BASE; NO JUMPERS
UNSEALED - LAMP 1 INDEPENDENT: T8+ T7-
LAMP 1 - INCANDESCENT 12V
NO LAMP IN LOCATION 2
BLACK BRACKET; NO GASKET
CONTURA V
LENS: 1 WHITE BAR LENS
BLACK ACTUATOR COLOR - HARD FINISH
LEGEND POSITION 1: HAZARD WARNING
LEGEND POSITION 2: DIRECTION INDICATOR
Special Notes
GBP/$50 EACH POS. LEGEND SETUP < 250 PCS
Additional Comments

Email: sales@carlingtech.com Application Support: team2@carlingtech.com


Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
NOW PART OF

V-Series
Contura® IV, V & VII
Sealed Rocker Switches

P ROD UC T WE BP A GE

request sample, configure part, watch video

Contura® IP66/68 Snap-In Mounted Switches


The V-Series switches are well known for their cutting
edge design, high quality, maximum performance and
unmatched reliability. These snap-in rocker switches
offer countless options for ratings, circuits, colors,
illuminations and symbols. These single or double pole
switches feature removable actuators in a choice of
actuator styles and colors, which may be purchased
and stocked separately. An optional plug-in terminal
connector enables pre-wiring of wire harness.

1-2 .4-20 125-250 12-24


Poles Amps VAC VDC

Typical Applications
∙ On/Off-Highway ∙ Armored Vehicles ∙ Commercial Food ∙ Any Application Requiring
∙ Marine ∙ Industrial Automation ∙ Medical Equipment Sealing Protection

www.carlingtech.com 860.793.9281 sales@carlingtech.com


Design Features

CLEAN CONNECTIONS
INTERCHANGEABLE ACTUATORS DUAL SEAL PROTECTION Options for both eight and
Panel redesign is a snap with our Seals out water, dust, debris, ten terminal base styles with
wide range of rocker styles. Achieve and sealed to IP66/68 for AMP & Packard compatible
maximum design variety with above-panel components connectors affords myriad
minimum inventory. Simply swap circuit options while
rockers to create an entirely new look providing ease of assembly.
for your panel.

MULTIPLE LIGHTING OPTIONS


OPTIONAL PANEL SEAL In addition to Incandescent BRASS ROLLER PIN SILVER PLATED BUTT
Helps prevent water/ lamps, our LED illumination Robust mechanism CONTACT MECHANISM
dust ingress behind is offered in a wide array of eliminates the need for Providing 50k to 100k
panel. light intensities, colors, as lubricants. Enables switch electrical cycles,
well as dual level, tri-color, to withstand -40°C to circuit and load
and flashing options. +85°C temperatures. dependent

2.
Actuator Options & Accessories
Contura II & III Contura X
The Contura II & III actuators are The raised bracket/bezel on the
constructed of thermoplastic Contura X helps prevent inadvertent
polycarbonate and are offered with actuation of the rocker, as well as
a hard nylon overlay or a “soft-touch” preventing debris from being trapped
elastomer overlay. These models under the actuator. This curved rocker
incorporate aesthetic designs on style is available with a variety of
the top and bottom of the rocker lenses and legends.
featuring two rows of raised “bumps”
on the Contura II and three “indented”
lines on the Contura III.

Contura IV Contura XI
The Contura IV’s “Shape to create The raised bracket/bezel on the
a Shape” actuator works with the Contura XI helps prevent inadvertent
curves, contours & advanced styling actuation of the rocker, as well as
of the latest panel designs, flowing preventing debris from being trapped
with these advanced curves & radii. under the actuator. This convex style
This actuator style fits on the Contura rocker is available with a wide variety of
flush bracket/bezel. lenses and legends.

Contura V Contura XII


The symmetrically curved Contura The Contura XII version features a
V actuator provides the perfect paddle style actuator with the raised
complement to the Contura IV’s bracket/bezel of Contura X and XI. The
“Shape to create a Shape” design contoured handle design provides
concept. With its flush style mounting intuitive recognition and ease of
bracket, Contura V can be mounted in operation and is available with all
between two Contura IV’s, by itself, or Contura X and XI lens and legend
in groups. offerings.

Contura VI (WAVE) Contura XIV


The Contura VI WAVE sealed rocker The Contura XIV represents a sleek new
switches, when used in a row, create crossover rocker design which should
an uniquely appealing “wave” design appeal to Trucks, Buses and Heavy
on your panel. A variety of colors and Vehicles as well as the Marine Industry.
finishes are available for both rocker Intuitive feel is provided by recessed
and wave insert. Contura VI features ridges along with a Center Groove
bar and oval lenses. which effectively defines the boundary
between top and bottom switch
functions.

Contura VII Illuminated Indicators &


Contura VII featuring gently curved Accessories
corners and edges assuring Alert operator of systems functions or
compatibility with most any panel malfunctions, are offered with removable/
design. Intuitive feel is maximized replaceable lamps in Contura II, II, V or X styles.
by the use of 2 embossed circular Accessories include connectors, mounting
pads located at opposite ends of panels, hole plugs, panel seals, and actuator
the rocker. Any combination of Bar removal tools. Refer to accessories page for
or Oval style lenses can be located full details
in the pads providing a truly unique
look, exclusive to Contura VII.

3.
Tech Specs
Electrical Environmental
Contact Rating 4VA @ 24VDC (MAX) resistive Sealing IP66/68, for above-panel
15 amps, 125VAC components of actual switch
10 amps, 250VAC only.
1/2 HP 125-250VAC
20 amps, 4-14VDC Corrosion Mixed Flowing Gas (MFG) Class III
15 amps, 15-28VDC 3 year accelerated exposure per
10A, 14VT ASTM B-827, B-845 Silver and gold
6A, 125VAC L contacts

Dielectric Strength 1500 Volts RMS Operating Temp -40°C to +85°C

Insulation Resistance 50 Megohms Vibration 1 Per Mil-Std 202F, Method 204D


Test Condition A 0.06 DA or
Initial Contact Resistance 10 milliohms max. @ 4VDC 10G’s 10-500 Hz. Tested with VCH
connector. Test criteria - No loss
Life Up to 100,000 cycles, circuit of circuit during test, pre and post
and load dependent test contact esistance.
Contacts Silver alloy, silver tin-oxide, fine Vibration 2 Resonance search24-50 Hz
silver 0.40 DA50-2000 Hz ±10 G’s peak
Horizontal Axis 3-5 G’s max.
Terminals Brass or copper/silver plate
Random 24 Hz 0.06 PSD-Gsq/Hz
1/4” (6.3mm) Quick Connect
60 Hz 0.50 100 Hz 0.50 200 Hz 0.025
terminations standard. Solder lug,
2000 Hz 0.025 No loss of circuit
Wire Lead
during test; <10μ seconds chatter.

Shock Per Mil-Std 202F, Method 213B, Test


Condition K @ 30G’s. Tested with
Physical VCH connector. Test criteria - No
loss of circuit during test, pre and
Lighted Incandescent - rated 10,000 post test contact resistance.
hours Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life Salt Spray Per Mil-Std 202F, Method 101D,
(LED is internally ballasted for Test Condition A, 96 Hrs. Sealed
voltages to 24VDC) version only.
Seals Internal Dust Mil STD 810, Method 510.2 Air
Optional external gasket panel Velocity 300 Ft/Min Duration 16Hr
seal
Thermal Shock Per Mil-Std 202F, Method 107F,
Base Polyester blend rated to 125°C with Test Cond. A, -55°C to +85°C. Test
a UL flammability rating of 94V0. criteria -pre and post test contact
resistance
Contura II, III, IV, V, VI, VII Hard Surface: Basic actuator
Actuator structure molded of thermoplastic Moisture Resistance Per Mil-Std 202F, Method 106F,
polycarbonate with a hard Nylon Test Criteria - pre and post test
66 thermoplastic surface overlay. contact resistance
Soft Surface: Basic actuator
structure molded of thermoplastic Ignition Protection All Contura switches with sealed
polycarbonate with an elastomer construction meet the
overlay. requirements of UL1500/ISO8846
for ignition protection, in addition
Contura X, XI, XII Actuator, Nylon 66 Reinforced rated to 105°C
to conformance with EC directive
VP
94/25/EC for marine products.
Lens Polycarbonate rated at 100°C

Contura XIV Polycarbonate lens/sub-rocker


with ABS shell Mounting Specifications .830
[21.08]

Panel Thickness Range


Gaskets Acceptable Panel Thickness
Actuator Travel (Angular Displacement) 0 .030 to .250 (.76 to 6.35mm)
1.450
TEST CUT
HOLE IN
1 .030 to .109 & .147 to .157 [36.83] ACTUAL
2 position 18° (.76 to 2.77mm & 3.73 to 3.98mm) MATERIAL

Recommended: No gasket with panel thickness


3 positions 9° from center of .032, .062, .093, .125,.187 or .250 SWITCH
MOUNTING HOLE

4. *Manufacturer reserves the right to change product specification without prior notice.
Ordering Scheme Contura IV

Sample
Part Number V 1 D A B T 0 B - E P C 00 - 0 00
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1. SERIES 6,7. LAMP (SAME CODING FOR BOTH SELECTIONS)


V V-Series Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2. CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Terminal Connections as viewed ( ) - momentary Red Amber Green Red
from bottom of switch: SP - single pole: terminals 1, 2 & 3. 2VDC A L F R
8 terminal 10 terminal DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S
12VDC C N H T
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 24VDC D P J V
1 - - 4 1 - - 4 * Consult factory for “daylight bright” LED options. Typical current
2 - - 5 2 - - 5 draw for LED is 20ma.
3 - - 6 3 - - 6
10- - 9
Position: 1 2 3 8. FLUSH BRACKET COLOR, PANEL SEAL 1
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF Black White Gray
2 B (ON) NONE OFF No Seal B W G
3 C ON NONE (OFF) One Seal C Y H
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON 9. ACTUATOR
7 K ON OFF (ON)
8 L (ON) OFF (ON) E Contura IV, left orientation
1,4
SPECIAL CIRCUITS T Contura IV, left orientation, laser etched
H* 2 & 3 2 & 3, 5 & 4 5&4 F Contura IV, right orientation
G* 2 & 3, 5 & 6 2 & 3 OFF R Contura IV, right orientation, laser etched
S* 2 & 3, 5 & 6 2 & 3 1&2 Actuator orientation over terminals:
M* (2 & 3, 5 & 6) 2 & 3 OFF 3,6
R* (2 & 3, 5 & 6) 2 & 3 2&1
E* 5 & 6 5 & 3 5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in 10. LENS
selection 4. External jumper between terminals 2 & 4 for circuit E are provided
by customer. Circuit E may be used for SP OFF-ON-ON circuit. 0 - No Actuator Z - No Lens
Clear White Amber Green Red Blue
1 6 B G M T
3. RATING 4 2 7 C H N U
3 8 D J P V
1 .4VA @ 28VDC Resistive
B 15A 24V 4 9 E K R W
C 20A 18V 5 A F L S Y EF
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) Lens color for LEDs must be clear, white, or match color of LED.
F 10A 14V, 6A 14VT (circuit G only) Green or blue lenses are not recommended with Neon lamps.
M .4VA/20A 12V
N .4VA/15A 24V
11. ACTUATOR COLOR 1, 5, 6

4. TERMINATION / BASE STYLE No Actuator 0 Black C Gray H Red S


White Y Nickel D Pewter E
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No
A B .250 TAB (QC) with barriers No 12. ACTUATOR LENS OR BODY LEGENDS 2
J K .250 TAB (QC) no barriers Yes T2 to 5
3 4 Solder Lug no barriers No 11 ON 12 OFF 13 I 14 O
C D Solder Lug No OFF ON O I
5 6 Wire Leads no barriers No
E F Wire Leads No 15 O O 16 O O 17 O I 18 I O
Note: Codes J & K for circuits H, G & M. Do not use silicone based F N N F
lubricants to reduce terminal insertion forces during connector assembly, as it F F
is detrimental to function and performance. For additional legend options & codes, visit us at www.carlingtech.com

5. ILLUMINATION & SWITCH SEALING 13. LEGENDS ORIENTTATION


Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above 0 No legend (used with codes 11-18 in selection 12)
terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols 1 Orientation 1
apply to LED lamps only 2 Orientation 2
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 3 Orientation 3
S 0 NONE – – 4 Orientation 4
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–) 1 2 3 4
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–) 13. ACTUATOR LENS LEGENDS
E 5 1 UP 1 (+) 7 (–)
2 UP 3 (+) 7 (–) 00 No legend this location / no actuator
F 6 1 INDEPENDENT 8 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when
2 UP 3 (+) 6 (–) switch requires two legends. If the two legends consist of one lens
and one body legend, lens legend must be specified in selection
G 7 1 INDEPENDENT 8 (+) 7 (–) 12; body legend specified in selection 14.
2 UP 3 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com.
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–) Notes:
SINGLE POLE SWITCHES ONLY Consult factory to verify horsepower rating for your particular circuit choice.
J 8 1 DOWN 3 (+) 8 (–) 1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is
2 INDEPENDENT 6 (+) 7 (–) standard on white, red and gray actuators. Custom colors are available,
K W 1 INDEPENDENT 8 (+) 7 (–) consult factory.
2 INDEPENDENT 6 (+) 7 (–) 3 Gloss brow is on left side of E actuator and right side of F actuator.
DOUBLE POLE SWITCHES ONLY 4 Additional ratings available. See V-Series Switch Accessories page.
L 9 1 DOWN 3 (+) 6 (–) 5 Laser etched rocker only available with lens code Z & actuator colors
M R 1 UP 3 (+) 6 (–) black, nickel or pewter.
N T 1 DOWN 3 (+) 6 (–) 6 Pewter and nickel colors only available with laser etched actuator.
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–) Configure Complete Part Number > Browse Standard Parts >
5.
Ordering Scheme Contura V

Sample
Part Number V 1 D A B T 0 B -G P C 00 - 0 00
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1. SERIES 6,7. LAMP


V V-Series Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2. CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Terminal Connections as viewed ( ) - momentary Red Amber Green Red
from bottom of switch: SP - single pole: terminals 1, 2 & 3. 2VDC A L F R
8 terminal 10 terminal DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T
1 - - 4 1 - - 4 24VDC D P J V
* Consult factory for “daylight bright” LED options. Typical current
2 - - 5 2 - - 5 draw for LED is 20ma.
3 - - 6 3 - - 6
10- - 9
Position: 1 2 3 8. FLUSH BRACKET COLOR, PANEL SEAL 1
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF Black White Gray
2 B (ON) NONE OFF No Seal B W G
3 C ON NONE (OFF) One Seal C Y H
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON
7 K ON OFF (ON) 9. ACTUATOR
8 L (ON) OFF (ON)
SPECIAL CIRCUITS 0 No Actuator
H* 2 & 3 2 & 3, 5 & 4 5&4 G Contura V
G* 2 & 3, 5 & 6 2 & 3 OFF P Contura V, laser etched
S* 2 & 3, 5 & 6 2 & 3 1&2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R*
E*
(2 & 3, 5 & 6)
5 & 6
2 & 3
5 & 3
2&1
5&1
10. LENS
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in 0 - No Actuator Z - No Lens style & location: #1 / #2
selection 4. External jumper between terminals 2 & 4 for circuit E are provided Clear White Amber Green Red Blue
by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1 6 B G M T
2 7 C H N U
3. RATING 4 3 8 D J P V
4 9 E K R W
1 .4VA @ 28VDC Resistive 5 A F L S Y
B 15A 24V Lens color for LEDs must be clear, white, or match color of LED.
C 20A 18V Green or blue lenses are not recommended with Neon lamps.
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V 11. ACTUATOR COLOR 1, 3, 5
N .4VA/15A 24V
No Actuator 0 Black C Gray H Red S
White Y Nickel D Pewter E
4. TERMINATION / BASE STYLE
8 term 10 Term Termination Jumper
1 2 .250 TAB (QC) no barriers No 12. ACTUATOR LENS OR BODY LEGENDS 2, 6
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5 11 ON 12 OFF 13 I 14 O
3 4 Solder Lug no barriers No OFF ON O I
C D Solder Lug No
5 6 Wire Leads no barriers No 15 O O 16 O O 17 O I 18 I O
E F Wire Leads No F N N F
Note: Codes J & K for circuits H, G & M. Do not use silicone based F F
lubricants to reduce terminal insertion forces during connector assembly, as it For additional legend options & codes, visit us at www.carlingtech.com
is detrimental to function and performance.

5. ILLUMINATION & SWITCH SEALING 12. LEGENDS ORIENTATION


0 No legend (used with codes 11-18 in selection 12)
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above 1 Orientation 1
terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols 2 Orientation 2
apply to LED lamps only 3 Orientation 3
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 4 Orientation 4
S 0 NONE – –
A 1 1 INDEPENDENT 8 (+) 7 (–)
B 2 1 DOWN 3 (+) 7 (–) 1 2 3 4
C 3 2 UP 3 (+) 7 (–)
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–) 13. ACTUATOR LENS LEGEND
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–) 00 No legend this location / no actuator
2 UP 3 (+) 6 (–) (used with codes 11-18 in selection 12) Selection 14 required when
G 7 1 INDEPENDENT 8 (+) 7 (–) switch requires two legends. If the two legends consist of one lens
2 UP 3 (+) 7 (–) and one body legend, lens legend must be specified in selection 12;
H Z 2 INDEPENDENT 8 (+) 7 (–)
U Y 1 INDEPENDENT 8 (+) 7 (–) body legend specified in selection 14.
2 INDEPENDENT 10 (+) 9 (–) For legend options & codes, visit us at www.carlingtech.com
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–) Notes:
2 INDEPENDENT 6 (+) 7 (–) Consult factory to verify horsepower rating for your particular circuit choice.
K W 1 INDEPENDENT 8 (+) 7 (–) 1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard
2 INDEPENDENT 6 (+) 7 (–) on white, red and gray actuators. Custom colors are available, consult factory.
DOUBLE POLE SWITCHES ONLY 3 Laser Etched rocker only available with lens code Z & actuator colors black,
L 9 1 DOWN 3 (+) 6 (–) nickel or pewter.
M R 1 UP 3 (+) 6 (–) 4 Additional ratings available. See V-Series Switch Accessories page.
N T 1 DOWN 3 (+) 6 (–) 5 Nickel and Pewter colors only available with laser etched actuator.
2 DOWN 1 (+) 4 (–) 6 Consult factory for laser etched lens callout.
P V 1 UP 1 (+) 4 (–)
6. 2 UP 3 (+) 6 (–)
Configure Complete Part Number > Browse Standard Parts >
Ordering Scheme Contura IV & V Locking

Sample
Part Number V 1 D A S W 0 B - J Z E 00 - 0
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13

1. SERIES 7. LAMP
V V-Series Lamp above terminals 3 & 6 end of switch
No lamp 0
Neon 1 125VAC 2 250VAC
Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
2. CIRCUIT 3
LED* superbright superbright
Terminal Connections as viewed ( ) - momentary Red Amber Green Red
2VDC A L F R
from bottom of switch: SP - single pole: terminals 1, 2 & 3. 6VDC B M G S
8 terminal 10 terminal DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 12VDC C N H T
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 24VDC D P J V
1 - - 4 1 - - 4 * Consult factory for “daylight bright” LED options. Typical current
2 - - 5 2 - - 5 draw for LED is 20ma.
3 - - 6 3 - - 6
10- - 9
Position: 1 2 3 8. FLUSH BRACKET COLOR, PANEL SEAL 1
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF Black White Gray
4 D ON NONE ON No Seal B W G
6 J ON OFF ON One Seal C Y H
7 K ON OFF (ON)
8 L (ON) OFF (ON)
9 N OFF NONE ON
9. HARD SURFACE ACTUATOR
CONTURA IV:
3. RATING 4
Orientation Black Gray Red White
Left J K L M
1 .4VA @ 28VDC Resistive Right N P R S
B 15A 24V
C 20A 18V Actuator orientation over terminals: 3,6 1,4
D 20A 12V CONTURA V: Black Gray Red White
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
F 10A 14V, 6A 14VT (circuit G only) U V W Y
M .4VA/20A 12V Actuator orientation over terminals: 3,6 1,4
N .4VA/15A 24V

10. LENS 5
4. TERMINATION / BASE STYLE
Z - No Lens
8 term 10 Term Termination Jumper Clear White Amber Green Red Blue
1 2 .250 TAB (QC) no barriers No A B C D E F bar lens
A B .250 TAB (QC) with barriers No G H J K L M oval lens
J K .250 TAB (QC) no barriers Yes T2 to 5
3 4 Solder Lug no barriers No Lens color for LEDs must be clear, white, or match color of LED.
C D Solder Lug No Green or blue lenses are not recommended with Neon lamps.
5 6 Wire Leads no barriers No
E F Wire Leads No
Note: Codes J & K for circuits H, G & M. Do not use silicone based
lubricants to reduce terminal insertion forces during connector as- 11. ACTUATOR LOCK FUNCTION AND COLOR 1
sembly, as it is detrimental to function and performance.
Lock Color Up Down Up & Down Center 3
Match Actuator A H R 1
Black B J S 2
5. ILLUMINATION & SWITCH SEALING White C K T 3
Red D L V 4
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above Safety Orange E M W 5
terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols
apply to LED lamps only Gray F G N 6
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals
S 0 NONE – –
C
H
3
Z
2 UP
2 INDEPENDENT
3 (+) 7 (–)
8 (+) 7 (–)
12. ACTUATOR LENS OR BODY LEGENDS 2

DOUBLE POLE SWITCHES ONLY 00 - No Legend


M R 1 UP 3 (+) 6 (–)
21 22 23 24
OFF ON O I
25 O 26 O 27 O 28 I
6. LOCK F N
F
Lock above terminals 1 & 4 end of switch. For additional legend options & codes, visit us at www.carlingtech.com
W low profile lock Y 6 high profile lock

Notes: Consult factory to verify horsepower rating for your particular


13. LEGENDS ORIENTTATION
circuit choice. 0 No legend
1 Custom colors are available. Consult factory. 1 Orientation 1
2 White imprinting is standard on black actuators; Black 2 Orientation 2
imprinting is standard on white, red and gray actuators. Custom 3 Orientation 3
colors are available, consult factory. 4 Orientation 4
3 Only available with 3 position circuits. Center OFF and special
circuits only available with center position lock function.
4 Additional ratings available. See V-Series Switch Accessories page. 1 2 3 4
5 Located at T3-6 end of switch.
6 Contura V style only.

Configure Complete Part Number > Browse Standard Parts >

7.
Ordering Scheme Contura VII

Sample
Part Number V 1 D A B T 0 B - Z R C 00 - 0 00
Selection 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1. SERIES 6,7. LAMP (SAME CODING FOR BOTH SELECTIONS)


V V-Series Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
No lamp 0
Neon 1 125VAC 2 250VAC
2. CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V
LED* superbright superbright
Terminal Connections as viewed ( ) - momentary Red Amber Green Red
from bottom of switch: SP - single pole: terminals 1, 2 & 3. 2VDC A L F R
8 terminal 10 terminal DP - double pole: terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S
8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T
1 - - 4 1 - - 4 24VDC D P J V
2 - - 5 2 - - 5 * Consult factory for “daylight bright” LED options. Typical current
draw for LED is 20ma.
3 - - 6 3 - - 6
10- - 9
Position: 1 2 3 8. FLUSH BRACKET COLOR, PANEL SEAL 1
SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5
1 A ON NONE OFF Black White Gray
2 B (ON) NONE OFF No Seal B W G
3 C ON NONE (OFF) One Seal C Y H
4 D ON NONE ON
5 F ON NONE (ON)
6 J ON OFF ON 9. ACTUATOR
7 K ON OFF (ON)
8 L (ON) OFF (ON) 0 No Actuator
SPECIAL CIRCUITS Z Contura VII
H* 2 & 3 2 & 3, 5 & 4 5&4
G* 2 & 3, 5 & 6 2 & 3 OFF Actuator orientation over terminals: 3,6 1,4
S* 2 & 3, 5 & 6 2 & 3 1&2
M* (2 & 3, 5 & 6) 2 & 3 OFF
R* (2 & 3, 5 & 6) 2 & 3 2&1 10. LENS
E* 5 & 6 5 & 3 5&1
Lens color for LEDs must be clear, white, or match color of LED.
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in Green or blue lenses are not recommended with Neon lamps.
selection 4. External jumper between terminals 2 & 4 for circuit E are 0 - No Actuator Z - No Lens
provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. White Amber Green Red Blue Lens style & location
6 B G M T
3. RATING 4
7 C H N U
1 .4VA @ 28VDC Resistive
B 15A 24V 8 D J P V
C 20A 18V 9 E K R W
D 20A 12V
E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) A F L S Y
F 10A 14V, 6A 14VT (circuit G only)
M .4VA/20A 12V 1 2 3 4 5
N .4VA/15A 24V
11. ACTUATOR COLOR/ THUMB PRINT COLOR 1
4. TERMINATION / BASE STYLE
O N/A - No Actuator C Black/Black
8 term 10 Term Termination Jumper H Grey/Black S Red/Black
1 2 .250 TAB (QC) no barriers No Y White/Black
A B .250 TAB (QC) with barriers No
J K .250 TAB (QC) no barriers Yes T2 to 5
3 4 Solder Lug no barriers No 12. ACTUATOR LENS OR BODY LEGENDS 2
C D Solder Lug No
5 6 Wire Leads no barriers No 11 ON 12 OFF 13 I 14 O
E F Wire Leads No OFF ON O I
Note: Codes J & K for circuits H, G & M. Do not use silicone based lubricants to
reduce terminal insertion forces during connector assembly, as it is detrimental
15 O O 16 O O 17 O I 18 I O
to function and performance.
F N N F
F F
For additional legend options & codes, visit us at www.carlingtech.com
5. ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above 13. ACTUATOR LENS OR BODY LEGENDS
terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols
apply to LED lamps only 0 No legend (used with codes 11-18 in selection 12)
Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 1 Orientation 1
0 NONE – – 2 Orientation 2
3 Orientation 3
A 1 1 INDEPENDENT 8 (+) 7 (–) 4 Orientation 4
B 2 1 DOWN 3 (+) 7 (–)
C 3 2 UP 3 (+) 7 (–) 1 2 3 4
D 4 1 DOWN 3 (+) 7 (–)
2 DOWN 1 (+) 7 (–)
E 5 1 UP 1 (+) 7 (–) 16. ACTUATOR LENS LEGEND
2 UP 3 (+) 7 (–)
F 6 1 INDEPENDENT 8 (+) 7 (–) 00 No legend this location / no actuator
2 UP 3 (+) 6 (–) (used with codes 11-18 in selection 12) Selection 14 required when
G 7 1 INDEPENDENT 8 (+) 7 (–) switch requires two legends. If the two legends consist of one lens
2 UP 3 (+) 7 (–) and one body legend, lens legend must be specified in selection
H Z 2 INDEPENDENT 8 (+) 7 (–) 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
U Y 1 INDEPENDENT 8 (+) 7 (–)
2 INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J 8 1 DOWN 3 (+) 8 (–) Notes:
2 INDEPENDENT 6 (+) 7 (–) Consult factory to verify horsepower rating for your particular
K W 1 INDEPENDENT 8 (+) 7 (–) circuit choice.
2 INDEPENDENT 6 (+) 7 (–) 1 Custom colors are available. Consult factory.
DOUBLE POLE SWITCHES ONLY 2 White imprinting is standard on black actuators.
Black imprinting is standard on white, red and gray actuators.
L 9 1 DOWN 3 (+) 6 (–) Custom colors are available, consult factory.
M R 1 UP 3 (+) 6 (–) 3 Additional ratings available. See V-Series Switch Accessories page.
N T 1 DOWN 3 (+) 6 (–) 4 Legends available for lighted oval lens version only
2 DOWN 1 (+) 4 (–)
P V 1 UP 1 (+) 4 (–)
2 UP 3 (+) 6 (–) Configure Complete Part Number > Browse Standard Parts >
8.
Dimensional Specs
inches [millimeters]

II CONTURA
CONTURAV IV CONTURA V V
CONTURA CONTURA
CONTURA
V VI CONTURA
CONTURAVII
VI
SHOWN WITH
SHOWN WITH SHOWNSHOWN
WITH WITH SHOWN
SHOWN WITH OVAL
WITH SHOWN WITHWITH
SHOWN LARGE LENS
OVAL S
BAR BAR
LENSLENS BAR LENS
LOW PROFILE LOCK LOW PROFILELENS
LOCK AND BAR
LENSLENS

1.922 1.922 1.922 1.922 1.950 1.950


1.922
.080 .080
[48.56] [48.56][48.56] [48.56][49.53] [49.53]
[48.82]
2.000 [2.03] [2.03]
[50.55]

1.079 1.079 1.126 1.126


[27.40] [27.40]1.479 1.479 [28.60] [28.60]
1.550 1.550 [37.57] [37.57]
[39.37] 1.126 [39.37]
[28.60]

10 TERMINAL BASE 10 TERMINAL BASE


10 TERMINAL
8 TERMINAL BASEBASE 8 TERMINAL
8 TERMINAL
BASE BASE W/BARRIER
8 TERMINAL BASEAND 10W/BARRIER AND
TERMINAL BASE
W/BARRIERS
W/BARRIERS W/BARRIERS
W/O BARRIERS W/OLAMP TERMINAL
BARRIERS LAMPBARRIERS
W/O TERMINAL

1.020 1.020 1.020 1.020 1.000


0.985 1.000 0.9
[25.91] [25.91][25.91] [25.91]
[25.40] [25.02] [25.40] [25.
1.050
[26.67]
.505 .505 .505 .505
.250 [6.35] .250 [6.35]
[12.83] [12.83][12.83] [12.83]
.031 [.78] .031 [.78]

.250 .250
.250 .250 .250 [6.35]
.250 [6.35]
.250 .031 .250 .0
.250
[6.35] [6.35][6.35] [6.35]X X
[.78]
[6.35] .031 [6.35] [.7
[6.35]X X X X .031
.031 .031 .031 .031[.78] [.78]
.820 .82
.031 .820 .820
[.78]
[.78]
[.78] [.78] [.78] [20.83] [20.
.390 .390 .820 .820 [20.83] .960
[20.83]
.96
.820 [9.90] [9.90][20.83] [20.83] .960 [24.38] .960 [24
[20.82] [24.38] [24.38]
.960 .960 .960 .960 .960
[24.38] [24.38] [24.38][24.38] [24.38]

8 TERMINAL BASE
10 TERMINAL BASE 8 TERMINAL
8 TERMINAL BASEBASE 8 TERMINAL BASE BASE
10 TERMINAL 1010
TERMINAL
TERMINALBASE
BASE
W/BARRIERS
W/O BARRIERS W/O BARRIERS
W/BARRIERS W/O BARRIERS
W/O BARRIERS W/O
W/O BARRIERS
BARRIERS

8 7 8 78 7 8 7
7 1 41 1 4
2.029 2.029
1 4 4
4
[51.53] [51.53]
2 5 2 52 5 2 5
5
3 6 3 63 6 3 6
6 10 9 10 9
9

SWITCH SHOWN WITH SWITCH


BOTTOM SHOWN WITH
VIEW BOTTOM VIEWBOTTOM VIEW BOTTOM VIEW
VCH CONNECTOR 8 VCH CONNECTOR 8 TERMINAL TERMINAL
TERMINAL SWITCH SHOWN WITH
TERMINAL SWITCH SHOWN WITH
OTTOM VIEW SWITCH SHOWN WITH
TERMINAL TERMINAL VC1 CONNECTOR 10 VC1 CONNECTOR
SWITCH SHOWN 10
TERMINAL ARRANGEMENT ARRANGEMENT ARRANGEMENT ARRANGEMENT
VC1 CONNECTOR 10
RRANGEMENT 8 TERMINAL BASE 10 TERMINAL BASE
8 TERMINAL BASE 10TERMINAL
TERMINAL BASE WITHTERMINAL
VC1
TERMINAL CONNECTOR 10
ERMINAL BASE
TERMINAL

9.
Circuit Diagrams:
CIRCUIT CIRCUIT CIRCUIT
CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM
3 3 6 13 4 6

1 A J

2 2 5 2 5

3 3 6 1 3 4 6

2 B K

2 2 5 2 5

3 3 6 1 3 4 6

3 C L

2 2 5 2 5

1 3 1 3 4 6 3 6

4 D M

2 2 5 2 5

1 3 1 3 4 6 1 3 6

5 E R

2 2 5 2 5

1 3 1 3 4 6 1 3 6

6 F S

2 2 5 2 5

1 3 3 6

7 G
SYMBOL LEGEND
SYM. DEFINITION
2 2 5
DESIGNATES TERMINALS AND CONTACTS
1 3 3 4 DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION

8 H DESIGNATES MOMENTARY CIRCUITS


DESIGNATES TWO POSITION CONNECTION
DESIGNATES EXTERNAL JUMPER PROVIDED
2 2 5 BY CUSTOMER

10.
Lamp Circuit Diagrams:
LAMP CIRCUIT LAMP CIRCUIT LAMP CIRCUIT LAMP CIRCUIT
CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM
+8 +8 +3 -6 +3 -6 +3 +6

A/1 1 F/6 1 2 L/9 1 SPECIAL 1 2


#1
-7 -7 -7

+3 +8 +3 +3 -6 +8 +6

B/2 1 G/7 1 2 M/R 2 SPECIAL 1 2


#3
-7 -7 -7

+3 +8 +1 +3 -4 -6 +8 +3

C/3 2 H/Z 2 N/T 1 2 SPECIAL 1 2


#4
-7 -7 -7

+1 +3 -8 +3 +6 +1 +3 -4 -6

D/4 1 2 J/8 1 2 P/V 1 2

-7 -7

+1 +3 +8 +6 +8 +10

E/5 1 2 K/W 1 2 U/Y 1 2

-7 (-)7 -7 -9

J-Series Hazard Warning Circuit Diagrams:


CIRCUIT CIRCUIT
CODE CIRCUIT DIAGRAM CODE CIRCUIT DIAGRAM

1 3 17 18 10(-) 10(-) 1 3 17 18

J1 1 J5 2

2 5 8 2 5 8

11 13 3 14 17 18 10(-) 11 13 3 14 6

J2 1 JA

5 8 5

1 3 17 18 10(-)
11 13 3 14

J3 1
JJ
NOTE:
2 5 8 J circuits are available for all
non-locking V-Series styles.
Consult factory for partnumber details.
1 3 17 18 10(-) 11 13 3 14 15 12 6 16

SYMBOL LEGEND
J4 1
JK SYM. DEFINITION
DESIGNATES TERMINALS AND CONTACTS
2 5 DESIGNATES LAMP LOCATION

11.
Stand-Alone Components
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VT with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS

Contura X & XI actuators without lenses separately Contura XII actuators without lenses separately

VVR 6 1 00 1 VVP J 1 Z 21 1 00
1 2 3 4 5 1 2 3 4 5 6 7
1. CONTURA X & XI ACTUATOR SEPARATELY
1 CONTURA XII ACTUATOR SEPARATELY
VVR
VVP
2. ACTUATOR STYLE & COLOR
2. ACTUATOR STYLE & COLOR
Black Gray White Red
Contura X 1 2 3 4 J Black K Gray N White M Red
Contura XI 6 7 8 9
3,4 LENS OPENING FOR 1
3. LENS OPENING FOR 1
Z No lens 1 Bar lens 2 Square lens
1 One bar lens
2 Two bar lenses 5 square lens on top/ 5, 7 LENS OR BODY LEGEND 2
3 One square lens bar lens on bottom
4 Two square lens (Contura X only) 00 - No Legend 21 22 23 24
OFF ON O I
4. ACTUATOR LENS OR BODY LEGEND 25 O 26 O 27 O 28 I
00 - No Legend this location F N
F
11 ON 12 OFF 13 I 14 O For additional legend options & codes, visit us at www.carlingtech.com
OFF ON O I
15 O O 16 O O 17 O I 18 I O 6 LEGEND ORIENTATION 3
F N N F
F F 0 No legend
1 Orientation 1
For additional legend options & code, visit us at www.carlingtech.com 2 Orientation 2
1 2
5. LEGEND ORIENTATION 1 1

0 No legend
1 Orientation 1 Contura X, XI & XII actuator lens assembly separately

VVL 2 1 00 0
2 Orientation 2
3 Orientation 3
4 Orientation 4 1 2 3 4

Contura X, XI & XII top piece of 2-piece lens separately 1 2 3 4 5

VVT 1
1 CONTURA X, XI & XII LENS SEPARATELY
VVL

2 LENS STYLE 3
1 2
1 TOP OF LENS SEPARATELY 1 Bar lens
2 One Piece Square lens
VVT 3 Bottom of Two-Piece Square lens 5

2 COLOR 3 TRANSLUCENT LENS COLOR

1 Clear 2 Smoke 3 White 1 Clear 2 White 3 Amber 4 Green 4 5 Red 6 Blue 4

4 LENS OR BODY LEGEND 2

Contura X, XI & XII actuator lens assembly: 00 - No Legend 21 22 23 24


OFF ON O I

25 O 26 O 27 O 28 I
F N

}
actuator stem top lens
two piece
F
lens assembly For additional legend options & codes, visit us at www.carlingtech.com.
posts mount toward actuator stem bottom lens

1 piece lens/bar lens are positioned the same as bottom lens for 5 LEGEND ORIENTATION 3
assembly, minus the top lens. Lenses snap in from bottom.
0 No legend
Notes: 1 Orientation 1
1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, 2 Orientation 2
or 2 must be chosen. 3 Orientation 3
2 Center of actuator marking not available for Contura XII. 4 Orientation 4 1 2 3 4
3 Legend is not available for bar style lens.
4 Not recommended with neon lamps.
5 Must also order top piece of 2 piece square lens separately.

12.
Accessories
Easily integrate Contura products into your system, with Contura
Accessories
Q.C. SELECTION GUIDE
Contura Connectors
PART NO
WIRE
RANGE
COMPANY ORIEN-
SERIES PLAIN TIN TATION
Q.C. SELECTION
PLATEDGUIDEAWG MM 2
BRASS
BRASS WIRE
(REF)
PART NO
02965580 RANGE
12 3.0
COMPANY 02965471 TIN 12010601 (2)16-14 (2)1.0-2.0 ORIEN-
SERIES
PACKARD PLAIN AWG 16-14 MM 1.0-2.0 2 TATION
BRASS02965470 PLATED B
58 SERIES BRASS (REF)
Q.C. SELECTION
02965469 Q.C.06288318
SELECTION
GUIDE Q.C. SELECTION GUIDE
20-18 GUIDE.5-.8
02965580 12 3.0
12084590 WIRE 105.0 WIRE WIRE
PART NO 12010601
02965471 PART NO PART NO
(2)16-14
RANGE (2)1.0-2.0
RANGE RANGE
COMPANY COMPANY COMPANY 12052224 123.0 ORIEN- ORIEN- ORIEN- TANG
PACKARD 02965470 TIN TIN 16-14 TIN 1.0-2.0 B
58SERIES
SERIES SERIES
PLAIN SERIES
PLAIN
PLATED 12015870
AWG PLAIN
PLATED 16-14
MM
AWG 2
PLATED
TATION 2
1.0-2.0
MMAWG TATION MM 2 TATION
PACKARD BRASS 02965469 BRASS BRASS
06288318 BRASS BRASS
20-18(REF) BRASS .5-.8 (REF) (REF)
METRI-PACK 12020035 (2)22-18 (2).5-.8 A
630 SERIES 02965580 12084590 12 02965580
02965580 105.03.012 3.0 12 3.0
12015832
02965471 12010601
02965471 12015869
12052224(2)16-14
12010601 123.0
02965471 20-18
12010601 (2)1.0-2.0
(2)1.0-2.0
(2)16-14 .5-.8
(2)16-14 (2)1.0-2.0 TANG
PACKARD PACKARD
02965470 Q.C. SELECTION
PACKARD
02965470 12052222
16-14 GUIDE 20-22
16-141.0-2.0
02965470 16-14 1.0-2.0 .35-.5
B1.0-2.0
16-14 B1.0-2.0 B
58 SERIES 58 SERIES 5812015870
SERIES TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT
PACKARD 02965469 06288318
02965469 20-18 06288318
02965469 .5-.8 20-18
06288318
WIRE .5-.8
20-18 .5-.8
METRI-PACK 12020035
PART NO (2)22-18 16-12 (2).5-.81.3-3 A SYMBOL
AMPCOMPANY 60253-1
630 SERIES 12084590 60253-2 105.0
12084590 RANGE
105.0
12084590 105.0
12015832 PLAIN 12015869 (2) 16 .5-.8 (2) ORIEN-1.3
250 SERIESSERIES 12052224 123.0 20-18 12052224
TIN12052224 123.0 123.0
TATION
TANG
B
TANG TANG
FASTIN-FASTON Q.C.
42100-1 SELECTION
PLATED
42100-2 AWG 18-14 MM 2
GUIDE .8-2
BRASS 12052222
12015870 12015870
16-14 20-22 12015870
1.0-2.0
16-14 .35-.51.0-2.0 16-14 1.0-2.0
PACKARD PACKARD PACKARD BRASS (REF) TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT
METRI-PACK60295-1 WIRE
METRI-PACK PART NO 60295-2
12020035
METRI-PACK
02965580 (2)22-18
12020035 16-12 22-18
12 (2).5-.8
(2)22-18
12020035
RANGE 3.0 1.3-3A(2).5-.8.3-.9
(2)22-18 A(2).5-.8 A
630 SERIES 630 60253-1 12015869
SERIES 630 60253-2
SERIES SYMBOL
AMP 12015832
COMPANY 12015832
02965471 1201060112015869
20-18
12015832
(2)16-14 12015869
.5-.8
20-18
(2)1.0-2.0 .5-.8
20-18
ORIEN- .5-.8
NOTE: Consult Delphi Packard and/orTIN Amp(2) on 16
actual (2) 1.3
part numbers and
250 SERIES SERIES
PACKARD PLAIN
12052222
02965470 PLATED 20-22
12052222 AWG
16-14 .35-.5
20-22 MM 2 .35-.5
12052222
1.0-2.0 TATION
20-22
B B availability.
TANG.35-.5
SYMBOL = TANGSHOWS
SYMBOLORIENTATION
= TANGSHOWS
SYMBOL =
OFORIENTATION
TANG INSHOWS
SLOTOF ORIENTATION
TANG IN SLOTOF TANG IN SLOT
AMP 58
FASTIN-FASTON is SERIES
a registered trademark
42100-102965469
BRASS 42100-2
BRASS
of AMP18-14
16-12
06288318
Inc. Harrisburg,
20-181.3-3
.8-2PA
(REF)
16-12 .5-.8 1.3-3 16-12 1.3-3
Delphi Packard
60253-1
60295-1is a registered
60253-2
60253-1
60295-2 trademark
60253-2
60253-1 of Delphi-Packard
60253-2 Electrical Systems Warren, Ohio
SYMBOL SYMBOL SYMBOL
AMP AMP 02965580 AMP (2) 16 22-18
12084590 12 (2) 1.3
105.0 (2) 16 3.0.3-.9(2) 1.3 (2) 16 (2) 1.3
250 SERIES 250 SERIES 250 SERIES B B TANG B
42100-1 02965471 12010601
12052224 (2)16-14
123.0.8-2 (2)1.0-2.0 .8-2
andB availability. .820
FASTIN-FASTON FASTIN-FASTON 42100-2
FASTIN-FASTON
42100-1 18-14
42100-2
42100-1 18-14
42100-2 18-14 .8-2
NOTE: Consult Delphi .820
PACKARDPackard and/or Amp
02965470
on actual
12015870 16-14
part numbers
16-14 .3-.9 1.0-2.0
1.0-2.0
AMP is a registered
58 SERIES
PACKARD 60295-2
60295-1trademark of AMP22-18
60295-1 60295-2
60295-1
Inc. Harrisburg, 22-18
60295-2
PA .3-.9
22-18 .3-.9[20.83]
METRI-PACK [20.83]
02965469 06288318
12020035 20-18
(2)22-18 .5-.8
(2).5-.8 A
NOTE:Delphi Packard
Consult 630
NOTE:
Delphi is a registered
SERIES
Packard
Consult trademark
NOTE: Packard
and/or
Delphi Amp
Consult
on actual
and/or of Delphi-Packard
Delphi part
Packard
Amp
12015832numbers
on actual
and/orand
12015869
12084590
part
Amp onElectrical
availability.
numbers
actual and
partSystems
availability.
20-18
105.0
numbers andWarren, Ohio
availability.
.5-.8
AMP is a registered
AMPtrademark
is a registered
ofAMP
AMPtrademark
isInc.
a registered
Harrisburg,
of AMP trademark
PA
Inc. Harrisburg,
of AMPPAInc. Harrisburg, PA TANG
Delphi Packard isDelphi
a registered
.820 Packardtrademark
is
Delphi12052224
12052222
a registered
Packard 123.0 of Delphi-Packard
is a 20-22
of Delphi-Packard
trademark
registered .35-.5 Systems
Electrical
trademark .820
of Delphi-Packard
Electrical
Warren, Systems
Ohio Electrical
TANG Warren,
SYMBOLSystems
=Ohio SHOWS
Warren, Ohio
ORIENTATION OF TANG IN SLOT
12015870 16-14
16-12 1.0-2.0
1.3-3 .770
[20.83]
PACKARD 60253-1 60253-2 [20.83] SYMBOL
AMP.820
METRI-PACK .820 12020035 .820(2)22-18 (2) 16 (2).5-.8
(2) 1.3 .820 A .820 .820 [19.56]
250 SERIES
630 SERIES [20.83] B [20.83] [20.83]
[20.83]
FASTIN-FASTON 12015832 [20.83] 12015869
42100-1 42100-2[20.83]20-18 18-14 .5-.8
.8-2
60295-1 12052222
60295-2 20-22
22-18 .35-.5
.3-.9
.920 .920 =
TANG SYMBOL SHOWS ORIENTATION OF TANG IN SLOT .770 1.170
16-12 1.3-3 .770 .770 .770
NOTE: AMPConsult Delphi60253-1
[23.37] Packard and/or Amp on actual part numbers and availability.
60253-2 [23.37] SYMBOL [19.56] [29.72]
AMP
250 SERIES is a registered trademark of AMP Inc. (2) 16
Harrisburg, PA(2) 1.3 [19.56] [19.56] [19.56]
Delphi Packard is a registered trademark of Delphi-Packard Electrical B
Systems Warren, Ohio
FASTIN-FASTON 42100-1 42100-2 18-14 .8-2
A A A A
.920
.920 60295-1
.820 .920 PACKARD 60295-2 .920 22-18 .3-.9 .920 .820 .920.920
VC2 .920 1.170 1.170PACKARD 630 1.170 1.170 PACKARD 630
PACKARD 630
VC1
[23.37]
[23.37] [20.83] [23.37]
630
[23.37]VC1 [23.37] [20.83] [23.37] [23.37] [23.37] VC2
[29.72] [29.72] [29.72][29.72] .950
NOTE: Consult Delphi Packard and/or Amp on actual B part numbers and availability.
B
AMP is a registered trademark of AMP Inc. Harrisburg, PA [24.13]
B B
A AMP, PACKARD 58Delphi Packard is a registered
A A A
trademark
AMP, PACKARD 58 of Delphi-Packard Electrical
A A
Systems Warren, Ohio
AMP AMP A A A A A A

10 3 2 1 8 7 4 5 69
A A A A
10 3 VC2 2 1 8 7 4 5 6 9VC2 .950 .770 PACKARD 630
PACKARD 630 VC2 VC2 VC2 PACKARD 630 PACKARD 630 PACKARD
PACKARDAMP, PACKARD 58PACKARD 630
630630 PACKARD 630 AMP, PACKARD 58
PACKARD 630
VC1 PACKARD 630 PACKARD PACKARD
VC1
630 630
VC1
PACKARD 630
VC1 VC1 VC1 VC2 VC2 .9503 2 1 8 .950 PACKARD 630
7 4 5 6
PACKARD 630
B VC1 B .820 B
PACKARD 630
B VC1 B B .820 VC2 [19.56]
[24.13] [24.13] .950[24.13]
B AMP, PACKARD 581.266 AMP, PACKARD 58
[20.83]
AMP, PACKARD
AMP, PACKARD
58 58 1.466
AMP, B
PACKARD 58 AMP
AMP, PACKARD 58 AMP [20.83]1.266 AMP AMP AMP B AMP1.466 B B B
58 58 [24.13]
B
1.250 B

AMP, 3 258[32.16]
10PACKARD 1 8 10 3 2 1 78 4AMP, 3 62958 1[37.24]
105PACKARD 78 4 5 6 9 10 73 4 2 51AMP689 10 3 .920 2 1 8 7104 3 5 2 619 8 7
[32.16] AMP4 5 69 73 42 15 8 6 9
AMP, PACKARD 58
[37.24]
AMP, PACKARD 58
3 2
B
AMP,
AMP,
PACKARD
PACKARD AMP, PACKARD 58
5 [31.75]
B
AMP, PACKARD 58

.920 1.170 1 AMP,8 PACKARD7 58 34 2 5 1 6 8 7 4 6 7 4 5 6


10 3 1.266 2 1 8 1.266 [23.37]71.466 4 1.2665 6 9 1.466 1.466
1.266 10 3 2 1.266 1 8
[23.37] 1.466
1.266 7 41.4665 6 9 1.466 1.250
[29.72] 1.250 1.250
AMP, PACKARD 58

.770 3 2 1 8 7 4 5 6
MARKING
[32.16]
1.266 DETAIL [32.16] [37.24] MARKING
[32.16]
1.466 DETAIL [32.16]
[37.24] [37.24]
1.266MARKING
[32.16] DETAIL [37.24]
[32.16] [37.24] MARKING
1.466 [37.24]DETAIL[31.75]
[19.56]
MARKING1.250
[31.75] DETAIL
[31.75] MARKING DETAIL
FRONT VIEWA
REAR VIEW A
FRONT VIEW REAR VIEWA A
FRONT VIEW REAR VIEW
[32.16]DETAIL
MARKING PACKARDMARKING
630
VC1 DETAIL
MARKING [37.24]
MARKING
DETAIL
PACKARD DETAIL
VC1 MARKING
630MARKING DETAIL DETAIL
MARKING MARKING
DETAIL
[32.16]
VC2 DETAIL MARKING DETAIL [37.24]
VC2 MARKING DETAIL MARKING
MARKING
PACKARD 630
DETAIL
DETAIL MARKING MARKING
.950 DETAIL MARKING
PACKARD 630
DETAIL MARKING DETAIL MARKING DETAIL
DETAIL
[31.75]
FRONT VIEW FRONT VIEWREARFRONT
VIEW VIEWREARB VIEW FRONT
REARVIEW
VIEW FRONT VIEW FRONT VIEW
REAR VIEW REAR VIEW FRONT REAR VIEWVIEW FRONT VIEW REAR
FRONT VIEW
VIEW REAR VIEW REAR VIEW
B
.920 .920 [24.13]
1.170
VC1
MARKING DETAIL AMP, PACKARD 58
MARKING DETAIL
AMP, PACKARD 58 AMP VC2
MARKING[23.37]
DETAIL AMP
MARKING DETAIL
B
MARKING
B
AMP, DETAIL
VCH MARKING DETAIL
FRONT 10 3 2
VC1VIEW REAR VIEW 8 [23.37]
1VC1 7
VC1 4 5 69 10 3 FRONT
VC2 2 1 8 VIEW
VC2 7 VC2
4 5 69 REAR VIEW 3 VCH FRONT
AMP, PACKARD 58
7 VIEW
[29.72]
VCH
PACKARD 58
VCH REAR VIEW
CONNECTOR HOUSING CONNECTOR HOUSING
CONNECTOR
CONNECTOR
HOUSING
HOUSING
CONNECTOR1.466HOUSING
2 1 8
CONNECTOR
4 5 6
HOUSING
CONNECTOR HOUSING
CONNECTOR
A 1.266 HOUSING
CONNECTOR HOUSING
1.466 A 1.266
(For AMP terminals only) CONNECTOR
A HOUSING
CONNECTOR
1.250 HOUSING
CONNECTOR
A HOUSING
[32.16] VC1 [37.24]VC1 (For AMP terminals
(For only)
AMP
[32.16]
VC2 (Foronly)
terminals AMP terminals
[37.24] only) PACKARD 630
[31.75] PACKARD 630

VC1
PACKARD 630 PACKARD 630
VC2 VC2 .950 VCH
CONNECTOR
MARKING DETAILHOUSING DETAIL [24.13]
B B
MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING MARKING DETAIL
CONNECTOR HOUSING
FRONT VIEW AMP, PACKARD 58
REAR VIEW
AMP, PACKARD 58
FRONT VIEW
AMP
REAR VIEW AMP B
FRONT
PACKARD VIEW
CONNECTOR
B
REAR HOUSING
PACKARDVIEW
10 3 2 1 8 7 4 5 69 (For
10 3AMP
2 terminals
1 8 only) 7 4 5 6 9 AMP,
3 2
58
1 8
AMP,
7
58
4 5 6
1.266
VC1 1.466 1.266
VC2 1.466 VCH 1.250
[32.16]
CONNECTOR HOUSING [37.24] CONNECTOR
[32.16]HOUSING [37.24] [31.75]
CONNECTOR HOUSING
(For AMP terminals only)
MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL

Contura X Boot (P/N VB1-01) Additional V-Series Ratings


FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW

VC1 VC2 VCH


CONNECTOR HOUSING
CONNECTOR HOUSING
(For AMP terminals only) 1 .4VA @ 28VDC Resistive
CONNECTOR HOUSING

4VB1-01
CONTURA X BOOT
10A VB1-01
250VAC
CONTURA X BOOT
VB1-01
1/2 HP,
CONTURA 15A
X 125
VAC 1/2 HP, No Agency Listings
BOOT
5 1 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
VB1-01
B 15A 24V CONTURA X BOOT
C VB1-01 20A 18VVB1-01
.757 .757 .757 CONTURA X BOOT
[19.23] [19.23] [19.23]
D 20A 12V
CONTURA X BOOT
E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
F VB1-01 10A 14V, 6A, 14VT (circuit G only)
.757
.757
[19.23] [19.23]
G
CONTURA X20A
BOOT 6V

.757 H 20A 3V
3.99 3.99 [19.23]
3.99 L 2 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
[101.35] [101.35] .757[101.35] M .4VA/20A 12V (combi-contact)
[19.23]
VRT (combination VRT gold/silver
VRT contacts for borderline dry circuit
Contura II, III, IV, V, VI & VII Actuator
TOP TOP TOP

3.99
INSERT POINTS UNDER .900
INSERT POINTS UNDER .900ACTUATOR applications)
REMOVAL
.900ACTUATOR REMOVAL
INSERT POINTS UNDER
TOOL TOOL
ACTUATOR REMOVAL
TOOL
[101.35]
ACTUATOR ACTUATOR
[22.86]
ACTUATOR
[22.86] (For flush[22.86]
N bracket)
.4VA/15A 24V(For
(combi-contact)
(For flush bracket) flush bracket)
Removal Tool (P/N VRT)
HOLD FLUSH ON BRACKET AND PUSH
HOLD FLUSH ON BRACKET AND PUSH
HOLD FLUSH ON BRACKET AND PUSH
IN IN IN

3.99TOP
TOP
TOP

TOP VRT
(combination gold/silver contacts for borderline dry circuit
ACTUATOR REMOVAL
[101.35] .900
applications)
INSERT POINTS UNDER
3.99
3.99
ACTUATOR
[22.86]
TOOL
(For flush bracket)
HOLD FLUSH ON BRACKET AND PUSH

[101.35]
IN
[101.35]
VRT
TOP TOP

.900NOTES VRT ACTUATOR REMOVAL


VRT
TOP
TOP
INSERT POINTS UNDER
.900 ACTUATOR REMOVAL TOOL
TOOLACTUATOR REMOVAL
ACTUATOR
.900 [22.86]
INSERT POINTS UNDER

INSERT
HOLD
IN
HOLD FLUSH ON BRACKET
ACTUATOR
POINTS
FLUSHIN UNDER
ON BRACKET AND PUSH
AND PUSH
[22.86] Consult factory to
(For flush bracket) TOOL
determine
(For availability for individual circuits and their HP rating.
flush bracket)
ACTUATOR
HOLD FLUSH ON BRACKET
IN
TOP AND TOP
PUSH [22.86] 1. Not(For
available with Contura 7 or 14 rocker styles.
flush bracket)
TOP 2. Rating L available with circuits 1, 4, A & D only.

13.
Accessories
Contura Mounting Panels
Dimensional Specifications: in. [mm]
+.008[+.20] +.008[+.20]
-.000[-.00] -.000[-.00]
MOUNTING PANEL .984 2.02
[51.3]
For additional units, add 1.03[26.2] per unit. For [25.00]
more than 2 V-Series Switches, add middle
section. Available in panel Thicknesses listed
below. Consult factory.
+.008[+.20] TEST +.008[+.20]
-.000[-.00]
CUT TEST CUT -.000[-.00]
1.90 HOLE IN HOLE IN
2.90
[48.2] [48.2]
ACTUAL ACTUAL MATERIAL
MOUNTING PANEL THICKNESS MATERIAL
.62 .187
[1.57] [4.75]
.093 .250
[2.36] [6.35]
.125 .375
[3.17] [9.52] VMS MOUNTING PANEL
MOUNTING PANEL OPENING
HOLE (2) UNITS

2.300 1.970 2.300


[58.42] [50.03] [58.42]

1.187 1.034 1.340


[30.14] [26.26] [34.03]

VME VMM VMS


MOUNTING PANEL MOUNTING PANEL MOUNTING
END MIDDLE PANEL

1.700 .670
[43.18] [17.01]
1.030 1.030
[26.16] [26.16]

2.300 2.300
[58.42] [58.42]

3.400 6.490
[86.36] [164.85]

VM6
VM3
MOUNTING PANEL
MOUNTING PANEL

Contura Hole Plug 1.450


[36.83]

Dimensional Specifications: in. [mm] TEST CUT


HOLE IN
ACTUAL
PLUG
MOUNTING HOLE
1.450 MATERIAL
[36.83]
.830
[21.08]

1.910
[48.51]
TEST CUT
.830 HOLE IN 1.900 VHP 1.900
[21.08] ACTUAL [48.26] CONTURA II,III HOLE PLUG [48.26]
MATERIAL

.960 .960 .960


[24.38] [24.38] [24.38]

1.240
1.460
[31.50]
1.820 [37.08]
[46.23]
.430 VHP
[10.92] CONTURA II,III HOLE PLUG .080
VH2
1.240 [2.03] STANDARD HOLE PLUG
1.820 [31.50] (With wing serrations)
.430
[46.23]
VH1
[10.92] STANDARD HOLE PLUG
2.000 (No wing serrations)
[50.80] (With VC1 connector attached)
VHP
MOUNTING PANEL PLUG
DETAIL VIEW VH1 DETAIL VIEW
VH2
1.067 VH1 HOLE PlUG VH2
HOLE PLUG
[27.10] HOLE PLUG (No wing Serrations HOLE PLUG
(No wing Serrations with VC1 connector attached) (with wing Serrations )
(with wing Serrations )
for ease of removal)

DETAIL VIEW
VH3 VH4 VH1,VH3 & VH5
CONTURA IV HOLE PLUG CONTURA IV HOLE PLUG HOLE PLUGS
1.928 (No wing serrations) (With wing serrations) (No wing serrations
[48.97] for ease of removal)

1.020
[25.91]

DETAIL VIEW
VH5 VH6 VH2,VH4 & VH6
CONTURA V HOLE PLUG CONTURA V HOLE PLUG HOLE PLUGS
(No wing serrations) (With wing serrations) (With wing serrations)

14.
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors
or visit www.carlingtech.com/findarep.

CANADA
EUROPE

USA
MIDDLE
EAST
MEXICO
AFRICA ASIA-PACIFIC
OCEANIA

SOUTH
AMERICA

About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and
electronic switches and assemblies, circuit breakers, electronic controls, power
distribution units, and multiplexed power distribution systems. With six ISO9001 and
IATF16949 registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than
manufacture electrical components, they engineer powerful solutions! To learn more
about Carling please visit www.carlingtech.com/company-profile.

To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications.

© Carling Technologies, Inc.


15. Carling, Contura are registered trademarks of Carling Technologies, Inc. in the U.S. and other countries.

You might also like