You are on page 1of 9

WATERPROOFING

REMEDIAL
CONSTRUCTION CHEMICALS DIVISION
Pidilite manufactures and markets a wide range of construction chemical products under two brands Dr. Fixit &
Roff covering different aspects of construction like waterproofing, building repairs, tile fixing, sealants, flooring
and grouts. Our Construction Chemicals products are also available in over 30 other countries

STATE-OF-THE-ART WATERPROOFING SYSTEMS

COMPANY PROFILE Waterproofing is a process that is designed to prevent water from penetrating a structure. Typically
waterproofing is done in various layers and stages to create multiple barriers so that water cannot penetrate
Pidilite Industries has been the pioneer and market leader in adhesives and sealants, construction chemicals, the structure. A combination of such stages is referred to as creating a “Building Envelope”.
art & craft products and polymer emulsions in India. Pidilite has some of the biggest brands in adhesives and
sealants category. These brands include Fevicol, M-seal and Fevikwik. Fevicol have become synonymous with However, often not enough importance is given to this very crucial area while constructing new structures.
adhesives to millions in India and is ranked amongst the most trusted brands in the country. Some of our other Over reliance on conventional and outdated systems, low awareness about modern waterproofing systems
major brands are Dr. Fixit, Pagel & Roff in Construction Chemicals, Cyclo and Motomax in auto care, Ranipal in and lack of trained expertise for application are some of the reasons for the same. Here’s where Dr. Fixit
fabric care, Fevistik glue stick and Hobby Ideas that is a Do-It-Yourself range of hobby and craft products. can help you to get the best waterproofing solutions for your new constructions. Dr. Fixit is India’s leading
brand in Waterproofing with a wide variety of products and solutions to meet all your waterproofing needs
- from foundations to walls to roofs. With access to the latest global technologies through its international
STATE-OF-THE-ART MANUFACTURING AND R&D subsidiaries and R&D centres,

We develop most of our products in-house with the help of a strong, research-driven innovation led with Dr. Fixit constantly brings innovative waterproofing solutions. Dr. Fixit also offers full technical support with
consumer insights. All the products are manufactured under ISO 9000 certification. Our R&D team works large pool of trained applicators.
closely with the marketing and technical service team to develop and enhance products that meet the
Call us now to benefit from our state-of-the-art waterproofing systems for your new constructions.
continuously changing requirements of our customers.
The treatment of common problems in old constructions like damp walls,
plaster cracks, efflorescence, etc. needs specialised products backed with
the right application procedures to ensure their proper treatment and
durability.

Dr. Fixit, India’s leading waterproofing and repairs expert presents a


guide to treat leakages, providing details of the finest products and
correct application methodology to treat such common problems.

WATERPROOFING Dr. fixit


SYSTEMS Solutions

REMEDIAL TREATMENT
Dr. Fixit NEWCOAT 6
FOR EXISTING ROOF

DAMPNESS OF INTERNAL WALLS Dr. Fixit WONDERPROOF 7

COATING FOR EXTERNAL WALLS Dr. Fixit RAINCOAT 8

SOLUTION FOR MASONRY DR. FIXIT CRACK-X 9


AND PLASTER CRACKS SHRINKFREE

WATERPROOFING SOLUTION DR. Fixit PU Injection 10


FOR LEAKING BASEMENTS

SOLUTION FOR VOIDS IN CONCRETE Pagel ZL 10 11

SOLUTION FOR STRENGTHENING Dr. Fixit Epoxy Injection 12


CONCRETE MEMBERS

SYSTEMATIC APPROACH CONCRETE REPAIR 13


TO CONCRETE REPAIR
REMEDIAL TREATMENT
FOR EXISTING ROOF DAMPNESS OF WALL

Dr. Fixit Wonderproof 1 - For severe


Dr. Fixit Newcoat
Dr. Fixit Roofseal Heavy Duty reinforced acrylic Dr.
Dr. Fixit
Fixit Wonderproof
Roofseal internal damp walls
waterproof coating Dr. Fixit Wonderproof 2 - Levelling plaster

High-performance waterproof coating for existing roofs Unique waterproofing solution for severe dampness in internal walls

HIGHLY ELASTIC System Life High adhesion BREATHABLE,


QUICK DRYING
UV-resistant AND RESILIENT Expectancy – with plastered ALLOWS WATER NO WATER CURING
TECHNOLOGY
COATING 5 years substrate VAPOUR TO PASS

Methodology Methodology
SURFACE PREPARATION
SURFACE PREPARATION
1. Mark the affected area to be repaired.
1. Cut open and clean cracks in the existing screed or Brickbat coba systems with compressed air.
2. Remove all the existing paint, pop, painters putty, etc. completely from the surface till the cement sand plastered
2. Repair these cracks with polymer modified mortar modified with Dr. Fixit Pidicrete URP. surface is exposed with the help of suitable tools.
3. Clean the surface thoroughly of all contaminants like dust, traces of curing compound, oil and 3. Ensure to chip off an additional 2sq. ft. area on all four sides of the affected damp area.
grease. Remove all surface imperfections, protrusions, structurally unsound and loose concrete.
APPLICATION
4. Prime the surface with Dr. Fixit Primeseal and allow it to dry. Apply the first coat of Dr. Fixit
1. Add 25 - 30% water to Dr. Fixit Wonderproof 1 to make a slurry coating and apply over the entire surface.
Newcoat.
2. Allow the first coat of Dr. Fixit Wonderproof 1 and leave it to dry for 4 to 6 hours.
5. While it is still wet, place a woven glass fibre mesh of measurements 2 mm x 2 mm and allow it to
soak completely. Immediately apply the second coat with a roller or squeeze, to ensure complete 3. Apply the second coat of Dr. Fixit Wonderproof 1 in a perpendicular direction to the first coat and allow it to dry for
coverage of the fibre mesh. 4 hours. In case of severe dampness a third coat of Dr. Fixit Wonderproof 1 is recommended.
4. Prepare a putty/mortar by adding 35 – 40 % water to Dr. Fixit Wonderproof 2 and apply it over the completely
6. Apply the third coat after 6 to 8 hrs, once the second coat is dry.
dried Dr. Fixit Wonderproof1 treated surface for levelling.
7. For roofs below 2000 sq. ft., use 2 coats of Dr. Fixit Newcoat Ezee. 5. After 20 to 30 minutes of the application of Dr. Fixit Wonderproof 2, level the surface using a putty blade/
aluminium float. Check the level and undulations, if required repeat the process until the desired level is achieved.
6. After 20 – 30 mins with the help of a water brush finish the surface with a putty blade/trowel.
7. Allow Dr. Fixit Wonderproof 2 to dry completely prior to painting.

1
Slab 1 Brick wall

1
2 Damaged Brickbat coba 2 Plaster
2
3 Dr. Fixit Primeseal 3 Dr. Fixit Wonderproof 1
8
4 Dr. Fixit Newcoat 1st coat 4 Dr. Fixit Wonderproof 2
3
5 Glass fibre mesh 7
5 Paint
6
6 Dr. Fixit Newcoat 2nd coat
5
7 Dr. Fixit Newcoat 3rd coat
4
4
8 Drip mould
3

2 5

7
COATING FOR SOLUTION FOR MASONRY
EXTERNAL WALLS AND PLASTER CRACKS

Exterior elastomeric coating that


Dr. Fixit
Dr. FixitRAINCOAT
Roofseal offers waterproofing as well as Dr.Fixit
Dr. FixitCrack-X
Roofseal
Shrinkfree
One time shrink free filler for plaster cracks
superior sheen

High performance acrylic elastomeric coating for waterproofing Non-shrinking crack filler for plastered walls
of external walls

Does not show


Excellent Bridges
Superior Almost twice Resistant to System life NON-SHRINK a depression UV AND
ability cracks up to
Sheen as No dilution as thick as algae and expectancy – EVEN AFTER after painting, WEATHER
to bridge 10 mm in single
against paint normal paint fungus 7 years CURING like other RESISTANT
cracks application
crack fillers

Methodology Methodology
SURFACE PREPARATION SURFACE PREPARATION

1. Check for surface cracks and treat them Dr. Fixit Crack-X Paste / Shrinkfree— depending on the 1. Remove the existing POP or painter’s putty till the plaster surface is exposed.
width of crack (Use paste for cracks up to 3 - 5 mm and Shrinkfree for cracks up to 10 mm).
2. Moisten the surface before applying Dr. Fixit Crack-X Shrinkfree.
2. Remove all surface imperfections and repair with polymer modified mortar using Dr. Fixit
APPLICATION
Pidicrete URP.
1. P
ress Dr. Fixit Crack-X Shrinkfree firmly into the crack only one time, with a spatula
PRIMING
or putty knife and level the surface
Prime the surface with Dr. Fixit Primeseal diluted 2:1 with water, maintaining the saturated surface 2. Allow it to dry in ambient conditions for 5 to 6 hours before painting for best
dry condition. Allow this to dry completely. results. A 7-day air curing is advised.
APPLICATION 3. Further, apply POP or painters’ putty once it is fully dry.

1. Apply the first coat of Dr. Fixit Raincoat without dilution. Allow to dry for 6 to 8 hrs.
2. Apply the second coat in a direction perpendicular to the first coat, ensuring complete
coverage of the area.

10
1
Spalled Plaster 9
2 Exposed Brick Masonry
8
3 Plaster Reinstated Using PMM
7
Mixed with Dr. Fixit Pidicrete URP
6
4 Column
5 Separation Joint Filled Using PMM 5
Dr. Fixit Pidicrete URP
6 Plaster Cracks Filled with 4
Dr. Fixit Crack-X Shrinkfree 3
7 Primer Coat of Dr. Fixit Primeseal
2
8 Separation Joint RCC-Masonry
9 2 Coats of Dr. Fixit Raincoat 1

10 Beam

9
Waterproofing
solution for SOLUTION FOR VOIDS IN
leaking basements CONCRETE

Injection grouting for leaking and damp All honeycombs and voids caused due to lack of proper
DR.
Dr.Fixit PURoofseal
Fixit Injection Dr. Fixit
Pagel Roofseal
ZL 10 compaction of concrete shall be taken up for treatment
basements (PU injection grouting) with injecting ultra-fine cementitious injections

Effective polyurethane injection grouting system for leaking Concrete if not compacted well, develops honeycombs
and damp basement and weakens the structure
Arrest any active water leakage in concrete and masonry walls. Treat honeycombs in concrete with cementitious
injections.
Low viscosity penetrating into the finest of cracks.
Excellent bond to concrete after setting.

Methodology
In basements, where there is drip leakage with or without pressure, they must be treated SURFACE PREPARATION
with low viscosity, polyurethane resin injections. Leakage from masonry walls or concrete
All areas marked as honeycombs and big voids will be filled and densified with this
members in the roof, walls, bathroom ceilings, etc. must be treated with polyurethane
treatment. The appropriate injection equipment as advised by the Dr. Fixit technical
injection. These injection system is the single-component system which reacts with water
team should be used to inject the Pagel ZL 10 ultra-fine injection, which is supplied in a
to form a foam or gel based on the amount of water encountered and bond extremely well
dry powder form. Right amount of water must be added (i.e. 0.4 to 0.5 w/c ratio) that
to arrest leakage and dampness.
will make the ZL 10 mixture extremely fluid.
Methodology
Small Voids and Honeycombs
Surface Preparation and Application
Appropriate nozzles generally used for any cementitious injection will serve the
1. Inject all cracks and voids actively leaking water with low viscosity, single-component purpose. The nozzles can be fixed directly over the voids.
polyurethane injection.
For Large Voids in Concrete
2. The injection packers may be fixed into holes drilled directly into the crack or drilled
diagonally from concrete adjacent to the crack. In case of curtain wall injection; long 1. For large voids in concrete, remove the loose aggregates and cement laitance
packers to be used to reach the void between waterproofing and structural member. 2. Provide shuttering over these areas and fill them in with Pagel ZL 10 grout through
3. Conduct fixing of packers with water-based epoxy putty that can set and harden in the the nozzles.
presence of water. 3. The grout will develop good strength and areas that are shuttered for injections,
4. If the void that needs to be filled is wider; then recommend a 4:1 ratio Dr. Fixit PU Foam can be undone, preferably after 48 hours, to ensure that no site abuse can
Injection: Water and if the void that need filling is too narrow then; 1:4 Dr. Fixit PU Foam damage the surface of the newly filled honeycombs.
Injection: Water is recommended. 4. If needed, finish off the surface of the concrete with the repair mortar Pagel R 20 /
5. Inject Dr. Fixit PU Foam Injection using injection packers fixed and 2-C pumps equipped 20, rapid cementitious repair mortar, to increase the protection of the area.
with a flushing unit.
6. Dr. Fixit PU Foam Injection can be injected to damp voids without water,alone , to seal
the leaks permanently.
7. Complete injecting into all the ports and allow the gel formation.
8. Over the next 1 or 2 days, the water leakage will get arrested and stop leaking through
the cracks or voids. In certain cases if leakage still persist do the injection again to get
best results.
9. This process is the same for all residential and public water-containing structures or
even dams and aqueducts.

11
SOLUTION FOR
STRENGTHENING SYSTEMATIC APPROACH
CONCRETE MEMBERS TO CONCRETE REPAIR

Dr.
Dr.Fixit Epoxy
Fixit Injection
Roofseal CONCRETE
Dr. REPAIR
Fixit Roofseal

Effective solution for cracks in structural members like Three pronged system for effective concrete repair
concrete retaining wall
Protect steel reinforcement bars with Dr. Fixit Epoxy Zinc Primer.
Strengthens damaged concrete when injected.
Use Dr. Fixit Epoxy Bonding agent for repair of RCC wall,
Can be injected even if water or moisture is present. underside of the slab.
Apply Dr. Fixit Micro Concrete to the cut area.

Methodology Methodology
Surface Preparation and Application SURFACE PREPARATION

1. Mark out the crack in the concrete member. 1. Mark out the area to be taken up for concrete repair and mechanically cut to a depth into the concrete well
behind the re-bars so that the micro-concrete can be placed effectively over a treatment with the suitable
2. Drill holes directly over the length of the crack using a drilling machine, at intervals bonding agent.
of 6 to 9 inches along the length of the crack.
2. Coat the steel reinforcement bars with a single component Dr. Fixit Epoxy Zinc Primer as cathodic protection..
3. In case of cracks up to 2 mm wide, fix the injection nozzles directly over the crack,
using a drilling machine. APPLICATION

4. Affix a non-return type of injection ports / nozzles in these holes with fast-setting 1. Use Dr. Fixit Epoxy Bonding Agent for an area over 10 sq. ft. of concrete repair in the underside of slab or repair
epoxy putty and let it dry for about 2 to 3 days. of the RCC wall.

5. Also, seal the crack between the ports with epoxy putty. 2. For other general repairs, use Dr. Fixit Pidicrete MPB, an acrylic bonding agent, by applying it neatly over a pre-
wetted surface.
6. In cases where the crack is wider than 2 mm up to 4 to 5 mm, drill holes at the sides
of the crack in a staggered fashion as shown in the picture, at intervals of 6 inches 3. After this dries, the cut area can be applied with Dr. Fixit Micro Concrete or Dr. Fixit Repair Mortar.
and affix them with epoxy putty as mentioned above.
4. After the repair mortar sets, apply Dr. Fixit Raincoat (any choice of colour) as a waterproofing.
7. Also, seal the face of the crack with a liberal application of the epoxy putty.
8. It is advised (since epoxy putty hardens sufficiently in a period of 2 to 3 days) to take
sufficient pressure off the injection hose and the pressure that may develop while
injecting the epoxy grout resin.
1 Rebar
9. Start pumping in Dr. Fixit Epoxy Injection after mixing it in a pail or a container, with
an appropriate injection pump. 2 Dr. Fixit EpoxyZinc Primer
3 Dr. Fixit EpoxyBonding Agent
10. Pumping can stop once the pressure is felt and no more epoxy resin can be injected.
4 Dr. Fixit Micro Concrete
11. Allow the resin to set for at least 7 full days, while it will harden and cure the crack.
5 Concrete Column
1
12. Over-painting or coating can be done on the concrete after the ports have been 6 Dr. FixitRaincoat
cut and removed, and the epoxy seal putty is ground off with a rotary scrubbing 2

machine for surface preparation. 3

13
15
Pidilite Industries Limited
Construction Chemicals Division
Ramkrishna Mandir Road, Post Box No. 17411
Andheri (E) Mumbai 400059 INDIA
Tel +91-22-2835 7000 • Fax +91-22-2835 7008
www.drfixit.co.in • techhelp@drfixit.co.in
REMEDI-BK-ENG-10/14

DISCLAIMER The product information & application details given by the company & its agents has been provided in good faith & meant to serve only as a general
guideline during usage. Users are advised to carry out tests & take trials to ensure on the suitability of products meeting their requirement prior to full scale usage
of our products. Since the correct identification of the problems, quality of other materials used and on-site workmanship are factors beyond our control, there are
no expressed or implied guarantee/ warranty as to the results obtained. The Company does not assume any liability or any consequential damage for unsatisfactory
results, arising from the use of our products.