Professional Documents
Culture Documents
Tank
Initial pressure (P0) 0 MPa [-0.099~10]
Input 0 MPa for atmospheric pressure and negative values for vacuum pressure.
Please refer to the product catalog for the sonic conductance and critical pressure ratio of the component.
Calculation results.
0.25
Time input Time(t) 0.02 s
0.2
Pressure input Pressure(P) MPa
Pressure P [MPa]
0.15
Time t Pressure P
Isothermal change
0.1
Adiabatic change
0.05
0
0 0.02 0.04 0.06 0.08
Time t [s]
Precautions:
• Isothermal change indicates the condition where heat transfer between inside and outside of the tank is performed sufficiently and temperature is maintained
constantly. Adiabatic change indicates the condition where heat transfer is shut-off completely. In reality, the air stays between these two conditions, so the
response time will also be the value between the isothermal and adiabatic changes.
• The values do not include the response time and piping volume of the valve.
Comments
Enter comments.
2022-4-26
Version:1.2.04