You are on page 1of 4

N-2339 ENGLISH SEP / 90

GRAVITOMETER - DATA SHEET

Standardization

The Responsible CONTEC Subcommittee provides guidance on the


interpretation of this Standard when questions arise regarding its contents.
The Department of PETROBRAS that uses this Standard is fully responsible
for adopting and applying the clauses thereof.
Mandatory Requirement: a provision established as being the most adequate
CONTEC and which shall be used strictly in accordance with this Standard. If a decision
Comissão de Normas is taken not to follow the requirement ("non-conformity" to this Standard) it
Técnicas shall be based on well-founded economic and management reasons, and be
approved and registered by the Department of PETROBRAS that uses this
Standard. It is characterized by the verb forms "shall", "it is necessary...", "is
required to...", "it is required that...", "is to...", "has to...", "only ... is
permitted", and other equivalent expressions having an imperative nature.
Recommended Practice (nonmandatory) a provision that may be adopted
under the conditions of this Standard, but which admits (and draws attention
to) the possibility of there being a more adequate alternative (not written in
this Standard) to the particular application. The alternative adopted shall be
approved and registered by the Department of PETROBRAS that uses this
Standard. It is characterized by the verbal form "should" and equivalent
expressions such as "it is recommended that..." and "ought to..." (verbs of a
nonmandatory nature). It is indicated by the expression: [Recommended
SC - 10 Practice].
Instrumentation and Copies of the registered "non-conformities" to this Standard that may
Industrial Automation contribute to the improvement thereof shall be submitted to the Responsible
CONTEC Subcommittee.
Proposed revisions to this Standard shall be submitted to the Responsible
CONTEC Subcommittee, indicating the alphanumeric identification and
revision of the Standard, the clause(s) to be revised, the proposed text, and
technical/economic justification for revision. The proposals are evaluated
during the work for alteration of this Standard.
“The present Standard is exclusive ownership of PETRÓLEO
BRASILEIRO S.A. - PETROBRAS, for internal use in the company,
and any copy for external use or disclosure, without previous
express authorization, implies unlawful act pursuant the relevant
legislation through which the applicable responsibilities shall be
imputed. The external circulation shall be regulated by a specific
clause of Secrecy and Confidentiality, pursuant the terms of the
intellectual and industrial property law.”

Foreword
PETROBRAS technical standards are prepared by Working Groups – GTs
(consisting of PETROBRAS specialists and PETROBRAS Subsidiaries specialists), are commented by Local
Representatives (representatives of the Industrial Units, Engineering Projects, Technical Divisions and
PETROBRAS Subsidiaries), are approved by Responsible Subcommittees SCs (consisting of specialists
belonging to the same speciality, representing the various PETROBRAS Departments and PETROBRAS
Subsidiaries), and approved by CONTEC General Assembly (consisting of representatives of the
Superintendencies of the PETROBRAS Departments and PETROBRAS Subsidiaries that use PETROBRAS
technical standards). A PETROBRAS technical standard is subjected to revision at any time by the Responsible
Subcommittee and must be reviewed every five years to be revalidated, revised or cancelled. PETROBRAS
technical standards are prepared in accordance with standard PETROBRAS N -1. For complete information
about PETROBRAS standards see PETROBRAS Technical Standards Catalog.

PROPERTY OF PETROBRAS
----------------------------------------------------------------
| |
| GRAVITOMETER - DATA SHEET | NI-2339
| |
| | SET/1990
| Standardization |
----------------------------------------------------------------
1 SCOPE

This standard cover gravitometer - data sheet to be used in PETROBRAS


designs.

2 STANDARDS AND/OR COMPLEMENTARY DOCUMENTS

In the aplication of this standard it’s necessary to consult:

IEC-79-0 - General requirements;


IEC-529 - Classification of degrees of protection provided by
enclosures.

3 BASIC CONSIDERATIONS

3.1 This data sheet should be attached to a RM (Material


Requisition) to be considered a purchasing document.

3.2 This data sheet should be considered as a lasting document of


the equipment after they have been full filled (as built) by the
manufacturer or engineering company.

---------------

/APPENDIX A

----------------------------------------------------------------
Origin: CONTEC - Subcommittee no 10 - Instrumentation and
Industrial Automation.
----------------------------------------------------------------
To be of real value this report should not be static, but should
be subjected to periodic review.
----------------------------------------------------------------
Key-words: gravitometer - data sheet.

----------------------------------------------------------------
Property of PETROBRAS 02 Page
2 NI-2339
----------------------------------------------------------------

----------------------------------------------------------------
Property of PETROBRAS

DATA SHEET
CLIENT SHEET
OF
PROJECT

PETROBRAS UNIT

GRAVITOMETER

1 TAG NUMBER

2 SERVICE

3 FUNCTION
4 MOUNTING
5 DEGREE OF PROTECTION
6 TYPE OF PROTECTION
7 POWER SUPPLY
8 ASSOCIATED TRANSMITER OUTPUT (CONVERTER)

10 TYPE
11 MEASUREMENT METHOD
12 SPAN

13 ACCURACITY

14 MATERIAL
15 PROCESS CONNECTION

16

17 OUTPUT INDICATOR
18 PURGE
19

20

21
22

23

24

25 FLUID TYPE
26 TEMPERATURE OP./ PROJECT EG. UNIT:

27 PRESSURE OP./ PROJECT EG. UNIT:


28 DENSITY @ 20º / 4 ºC / TEMPERATURE..OP
29 VISCOSITY OP.CONDICTION (Cp)

30 POUR POINT ( C )
31
32 REFERENCE
33 MODEL
34 NOTES :

ORIGINAL REV. A REV. B REV. C REV. D REV. E REV. F REV. G REV. H


DATE
EXECUTION
CHECK
APPROVAL
INFORMATION CONTAINED IN THIS DOCUMENT IS PROPERTY OF PRETROBRAS. UNAUTHORIZED USE IS PROHIBITED