Professional Documents
Culture Documents
Phone: +62 542 762810 Ext. 4007, Call Center 1500 228
Email: sos.manager@trakindo.co.id
Terdeteksi Kontaminasi Air Yang Berlebihan (1.12%) Pada Sampel Oli. Tes Viskositas Dan Besaran Partikel Tidak Dapat Dilakukan.
Hasilnya Tidak Merepresentasikan Kondisi Aktual Elemen Karena Tingginya Kandungan Air. Index Pq Di Atas Normal. Keausan
Abnormal Pada Gear, Shaft, Bearing Atau Spline. Hentikan Unit Sesegera Mungkin Untuk Perbaikan. Secepatnya Periksa Final Drive
Dan Temukan Sumber Masuknya Air. Inspek Kerusakan Seal/Gasket, Kekencangan Bolt Pada Cover. Periksa Drain Plug Dari
Serpihan Material. Segera Lakukan Perbaikan. Ambil Sampel Oli Kembali Setelah 250 Jam Untuk Memonitor. Bilas Kompartemen
Untuk Menghilangkan Kontaminan Dan Serpihan Material.
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 1 of 2
FINAL DRIVE RIGHT
J21B-52057-0104
SERIAL NUMBER: 40511_J210
EQUIP NUM: EX80101KM
Urgent Action Required
KOMATSU PC800SE-7
REPORT COMMENT
THE ANALYSIS PROVIDED ARE INDICATIVE OF CONDITIONS BASED UPON SAMPLE INFORMATION RECEIVED AND THE QUALITY OF SAMPLE SUPPLIED.
RECOMMENDATIONS ARE PROVIDED AS A GUIDE ONLY. ANY DECISION TO REPAIR COMPONENTS IS ENTIRELY AT THE CUSTOMER'S DESCRETION. KINDLY ADVISE
YOU TO CONTACT US PRIOR TO 7 DAYS AFTER REPORT RELEASE SHOULD YOU NEED FURTHER DISCUSSION ABOUT THIS SAMPLE. ----- ANALISA INI BERSIFAT
INDIKASI, BERDASARKAN INFORMASI DARI LABEL & SAMPLE YG DI KIRIMKAN. JIKA ADA KEPUTUSAN PERBAIKAN COMPONENT SEPENUHNYA KEBIJAKAN CUSTOMER.
DISARANKAN AGAR DISKUSI LEBIH LANJUT MENGENAI SAMPLE INI HARUS DILAKUKAN SEBELUM 7 HARI DARI TANGGAL LAPORAN DI TERBITKAN.
Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 2 of 2