FINAL DRIVE RIGHT EQUIP NUM: EX80101KM SERIAL NUMBER: 40511_J210


KOMATSU PC800SE-7
J21B-52057-0104 Urgent Action Required Interp By: Zaid Muhardian
LABEL#: B0G56
Interpreted On: 26-Feb-22
SAMPLE SHIP TIME (days) : 19
Excessive Water Contamination (1.12%) Detected In This Oil Sample. The Viscosity & Large Particle Test Can Not Be Performed.
HARMONI PANCA UTAMA Elemental Analysis Results Do Not Represent The Actual Condition Of Elements Due To High Water Content In The Sample. Ferrous
PT. Debris (Pq) Above Normal, Abnormal Wear Has Occurred On Gear, Shaft, Bearings Or Spline. Suggest Stop Unit Immediately To
Correct Problem(S). As Soon As Possible, Inspect Final Drive And Determine The Source Of Water Entry. Inspect Seal/Gasket
0G56 - (KJA) KALTIM JAYA
Failure, Cover Bolts Tightness. Check The Drain Plug For Debris. Make Necessary Repairs. Re-Sample When Hours On Oil Reach
BARA - HARMONI PANCA
250 Hours To Monitor. Flush The Compartment To Remove Contaminants And Debris.
UTAMA PT.
LOCATION: KJA

RECEIVED DATE: 22-Feb-22

BRANCH REC DT: 18-Feb-22

Terdeteksi Kontaminasi Air Yang Berlebihan (1.12%) Pada Sampel Oli. Tes Viskositas Dan Besaran Partikel Tidak Dapat Dilakukan.
Hasilnya Tidak Merepresentasikan Kondisi Aktual Elemen Karena Tingginya Kandungan Air. Index Pq Di Atas Normal. Keausan
Abnormal Pada Gear, Shaft, Bearing Atau Spline. Hentikan Unit Sesegera Mungkin Untuk Perbaikan. Secepatnya Periksa Final Drive
Dan Temukan Sumber Masuknya Air. Inspek Kerusakan Seal/Gasket, Kekencangan Bolt Pada Cover. Periksa Drain Plug Dari
Serpihan Material. Segera Lakukan Perbaikan. Ambil Sampel Oli Kembali Setelah 250 Jam Untuk Memonitor. Bilas Kompartemen
Untuk Menghilangkan Kontaminan Dan Serpihan Material.

SAMPLE INFORMATION For additional sample history, go to: my.cat.com

OIL CONDITION AND PHYSICAL/CHEMICAL TEST


07-Feb-22 08-Dec-21 25-Oct-21 23-Aug-21 07-Feb-22 08-Dec-21 25-Oct-21 23-Aug-21
Sampled Date
Sample Id J21B-52057-0104 J21B-51349-0607 J21B-51320-3029 J21B-51245-1666 VISCOSITY AT 100°C (Centistokes)
Lab Date 26-Feb-22 15-Dec-21 16-Nov-21 02-Sep-21 V100 Viscosity at 100 C 11.2 10.70
Meter [Hr] 25397 28205 27471 26608
Comp Meter [Hr] 25397 28205 27471
Meter On Fluid 2000 0 0
WATER CONTAMINATION
Fluid Brand SHELL UNKNOWN UNKNOWN SHELL
W Water E P N N
Fluid Weight 30 30 30 30
Fluid Type SPIRAX UNKNOWN UNKNOWN SPIRAX S4 CX
Fluid Change N Y N N
Filter Change U U U U WATER CONTENT (% - OIL; mg/Kg=ppm - FUEL)
H2O Water 1.1203 0.6252

PARTICLE QUANTIFIER INDEX


WEAR METAL/CONTAMINANT/ADDITIVES PQI PQ Index 1307 471 39 20
07-Feb-22 08-Dec-21 25-Oct-21 23-Aug-21
ELEMENTS (ppm)
Cr Chromium 5 1 0 PARTICLE COUNT AND OTHER ANALYSIS
1 1 0 07-Feb-22 08-Dec-21 25-Oct-21 23-Aug-21
Pb Lead
Fe Iron 486 39 29
PCV PC Visual DARK-HQF-ME DARK-MQF-M - -
Cu Copper 17 1 1
Al Aluminum 90 7 1
Sn Tin 1 0 0
PARTICLE COUNT (Count/mL)
Ni Nickel 1 0 0
6µ 6µ 67759 29043
B Boron 9 8 1
14µ 14µ 1545 1827
K Potassium 12 2 0
ISO6 ISO6 23 22
Na Sodium 2 1 0
ISO14 ISO14 18 18
Si Silicon 269 32 16
Ca Calcium 3401 3032 3059
P Phosphorus 925 863 800
Zn Zinc 1108 1110 1037
Mg Magnesium 50 42 15
Mo Molybdenum 4 2 1

Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 1 of 2
FINAL DRIVE RIGHT
J21B-52057-0104
SERIAL NUMBER: 40511_J210
EQUIP NUM: EX80101KM
Urgent Action Required
KOMATSU PC800SE-7

REPORT COMMENT
THE ANALYSIS PROVIDED ARE INDICATIVE OF CONDITIONS BASED UPON SAMPLE INFORMATION RECEIVED AND THE QUALITY OF SAMPLE SUPPLIED.
RECOMMENDATIONS ARE PROVIDED AS A GUIDE ONLY. ANY DECISION TO REPAIR COMPONENTS IS ENTIRELY AT THE CUSTOMER'S DESCRETION. KINDLY ADVISE
YOU TO CONTACT US PRIOR TO 7 DAYS AFTER REPORT RELEASE SHOULD YOU NEED FURTHER DISCUSSION ABOUT THIS SAMPLE. ----- ANALISA INI BERSIFAT
INDIKASI, BERDASARKAN INFORMASI DARI LABEL & SAMPLE YG DI KIRIMKAN. JIKA ADA KEPUTUSAN PERBAIKAN COMPONENT SEPENUHNYA KEBIJAKAN CUSTOMER.
DISARANKAN AGAR DISKUSI LEBIH LANJUT MENGENAI SAMPLE INI HARUS DILAKUKAN SEBELUM 7 HARI DARI TANGGAL LAPORAN DI TERBITKAN.

Result Explanation Section

Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 2 of 2