This document is a portable generator inspection form used to check generators before use. It lists 5 components to inspect: the engine, generator, general aspects, earthing, and certifications. Each component lists specific items to check such as for leaks, exposed terminals, labelling, spill containment, decibel output, earthing cable attachment, and ELCB ratings. The form is used to document the inspection results and determine if the generator passes, requires holding, or is rejected for use.
This document is a portable generator inspection form used to check generators before use. It lists 5 components to inspect: the engine, generator, general aspects, earthing, and certifications. Each component lists specific items to check such as for leaks, exposed terminals, labelling, spill containment, decibel output, earthing cable attachment, and ELCB ratings. The form is used to document the inspection results and determine if the generator passes, requires holding, or is rejected for use.
This document is a portable generator inspection form used to check generators before use. It lists 5 components to inspect: the engine, generator, general aspects, earthing, and certifications. Each component lists specific items to check such as for leaks, exposed terminals, labelling, spill containment, decibel output, earthing cable attachment, and ELCB ratings. The form is used to document the inspection results and determine if the generator passes, requires holding, or is rejected for use.
Period of Inspection : Premob Thirds months Others
No Component Condition/Fault to be Checked N/A OK FAIR Remarks
1 Engine Check for oil leaks Check for fuel leaks Check for exposed pinch points Check battery terminals covered Check battery secured from movement Check exhaust is not directed at worker level Check internal of cabinet free of combustibles 2 Generator Check for exposed/unprotected terminals Check condition of wiring for wear /damage Check labelling of terminals Spill containment tray installed 3 General Check decibel output under load. If over 85dBa, is hearing warning sign attached and safe distance clearly marked Check responsible Subcontractor is clearly marked on generator. Spark arestor 4 Earthing Check that suitable size earth cable is securely attached to frame and to earth stake. Check that earth leakage is fitted to all output. What is ampere trip of ELCB ? Ma .............. What is the trip time of ELCB ? Ma .............. Check ELCB 0.3 ma 5 Certification If generator is rated at 5kV or over