You are on page 1of 3

Intermediate Well Control Equipment Inspection Criteria

Equipment Group: SIDE OUTLET VALVES


Drilling Contractor :
Rig Unit Number – Contractor :
Rig Unit Number – PDO :
Present Well Location :
Date

SIDE OUTLET VALVES (YEARLY)


Note :
1. Check validity of last “Major Inspection Certificate
2. No heating, welding, cutting and grit blasting is allowed on any part of this equipment.
3. 3rd party is required for NDT, US and pressure testing.
4. PTW is required for pressure tests in the field.
5. Scour marks must be polished
NRV VALVE
Make/Brand:
Type :
Serial Number :
Year of Manufacturing
When : Conducted by :
Last Major Maintenance
Last Intermediate Maintenance
Notes: Information from: IADC/SPE 23900 and Visual Correct / Comments
Cameron Cooper. Inspection Done ?
YES NO

1 Degrease and pressure clean complete unit.


2 Disassemble & Inspect all valves, grease with
OEM recommended grease and ensure that all
valves are moving freely.
3 Check bolts for wear (corrosion) and mech.
damages replace if required
4 Check ring grooves for wear (corrosion) and
mech. damages
5 Reassemble
6 Perform low/high pressure test to full working
pressure.

Well Control Equipment Intermediate Inspection: Side Outlet Valves Generated by : WCF
Page 1 of 3
MANUAL VALVES
Make/Brand:
Type :
Serial Number :
Year of Manufacturing
When : Conducted by :
Last Major Maintenance
Last Intermediate Maintenance
Visual Correct / Comments
Inspection Done ?
YES NO
1 Degrease and pressure clean complete unit.
2 Disassemble & Inspect all valves, grease with
OEM recommended grease and ensure that all
valves are moving freely.
3 Check bolts for wear (corrosion) and mech.
Damages replace if required
4 Check ring grooves for wear (corrosion) and
mech. damages
5 Reassemble and Function test the valve by
opening and closing the valve.
6 Ensure correct hand-wheel is assembled
7 Perform low/high pressure test to full working
pressure.
HCR- VALVES
Make/Brand:
Type :
Serial Number :
Year of Manufacturing
When : Conducted by :
Last Major Maintenance
Last Intermediate Maintenance
1 Degrease and pressure clean complete unit.
2 Disassemble & Inspect valve, grease with
OEM recommended grease and ensure that all
valves are moving freely.
3 Function test the valve by opening and closing
the valve.
4 Check bolts for wear (corrosion) and mech.
Damages replace if required
5 Check ring grooves for wear (corrosion) and
mech. damages
4 Reassemble and perform low/high pressure
test to full working pressure.

Well Control Equipment Intermediate Inspection: Side Outlet Valves Generated by : WCF
Page 2 of 3
Function Test of HCR-Valves
Note :
1. Function test of HCR-Valve to be performed in “non installed” mode using rig test pump
2. Ensure all temporary installed test lines are in good condition and properly routed.
3. Ensure PTW is in place prior to start function Test
1 Close valve with hand wheel and ensure that
valve is moving freely.
2 Open valve with hand wheel and ensure that
valve is moving freely
3 Inspect the valve bore to unsure that the gate
bore is properly aligned.
4 Connected hose to closing port and close gate
and apply 150psi. check tell tale
5 Connected hose to opening port and open gate
and apply 150psi. check tell tale
6 Repeat step 4 & 5 applying 1500psi./ 5 min

All above Name : Company : Date : Signature :


Inspections &
Tests conducted
by :
(Authorized Third
Party Inspection
Company)
Agreed by :
(Contractor Rig
Manager)
Verified by :
(PDO Site
Representative)
Authorized by :
(Contractor DS)
Seen by :
(PDO SWE)

Well Control Equipment Intermediate Inspection: Side Outlet Valves Generated by : WCF
Page 3 of 3