You are on page 1of 10

FOR EDUCATIONAL PURPOSE ONLY – DO NOT USE THIS METHOD FOR DETAIL DESIGN – ALWAYS CONSULT A REP

Calculation Tool
Heat flux through a single pipe KNOWING skin temperatures

Pipe skin temperatures – Please input


Temperature inside T1 ºc 4
Temperature outside T2 ºc 4.5
Material conductivity λm W/m/K 30
Tube inlet diameter Di mm 81
Tube thickness e mm 2.3
Tube oulet diameter Do mm 85.6
Heat flux calculation
Resistance R 0.0000788
Heat flux Φ W/m2 -6344.9
Heat transfer through the wall – Please input the wall size
Pipe length L m 3.5
External surface A m2 0.9
Heat transfer Q W -5971.9
kW -6.0

If you spot a mistake or wish to suggest an improvement, please contact : contact@myengineeringtools.com

Copyright www.MyEngineeringTools.com

important information and calculation must always be double checked by the user through the quality procedure of his organiz
another source. The user must always respect all applicable regulation. The use of the information is at the user and its organ
AYS CONSULT A REPUTABLE SUPPLIER FOR DETAIL DESIGN

n temperatures

eeringtools.com

y procedure of his organization or by checking


s at the user and its organization own risk and
Pipe with insulation
FOR EDUCATIONAL PURPOSE ONLY – DO NOT USE THIS METHOD FOR DETAIL DESIGN – ALWAYS CONSULT A RE

Calculation Tool
Heat flux through a pipe with insulation KNOWING skin te

Pipe skin temperatures – Please input


Temperature inside T1 ºC 90
Temperature outside T2 ºC 5

Tube inlet diameter Di mm 160.3


Tube oulet diameter Do mm 250

Heat flux calculation


Isıl iletkenlik katsayısı U 0.442
Heat flux Φ W/m 37.6
Heat transfer through the wall – Please input the wall size
Pipe length L m 1
External surface A m2 0.8
Heat transfer Q W 29.5
kW 0.03

t ºC 89.999
q kg/m3 965.25
Cp kj/kgC 4.208
m m3/s 0.0125

FOR EDUCATIONAL PURPOSE ONLY – DO NOT USE THIS METHOD FOR DETAIL DESIGN – ALWAYS CONSULT A RE

Page 3
Pipe with insulation

If you spot a mistake or wish to suggest an improvement, please contact : contact@myengineeringtools.com

Copyright www.MyEngineeringTools.com
The content of MyEngineeringTools.com is copyrighted but no warranty nor liability is ensured. The content of this site is
and calculation must always be double checked by the user through the quality procedure of his organization or by che
respect all applicable regulation. The use of the information is at the user and its organization o

Page 4
Pipe with insulation
ALWAYS CONSULT A REPUTABLE SUPPLIER FOR DETAIL DESIGN

Tool
n KNOWING skin temperatures

You can input up to 5 layers on the p


Please input the conductivity and wid
Thickness
D1
D2 4
D3 36.95
D4 3.9
D5
D6

Rg [mC/W]
do [mm]
L [mm]
Z [mm]
λg [W/mC]

89.25963348

ALWAYS CONSULT A REPUTABLE SUPPLIER FOR DETAIL DESIGN

Page 5
Pipe with insulation

@myengineeringtools.com

ured. The content of this site is to be seen as a help and important information
e of his organization or by checking another source. The user must always
the user and its organization own risk and own cost.

Page 6
Pipe with insulation

0.211747516

You can input up to 5 layers on the pipe


Please input the conductivity and width
D λm R Resistance
160.3 312.7
168.3 76 0.00010 5.6 323.9 51
242.2 0.028 2.06910 19.85 363.6 0.045
250.0 0.43 0.01173 40.5 444.6 0.027
0.00000 5.2 455 0.43
0.21175
Sum 2.293

0.21175 Toparağın ısıl iletkenlik direnci


250.0 Kılıf boru dış çapı
500.0 Toprak dolğu yüksekliği (Boru merkezi ile toprak yüzeyi arası + 100mm olarak hesap edilir)
600 Toprağın ısıl iletkenlik katsayısı (toprak özellikleri bilinmiyorsa 2 W/mC alınabilir)
1.7

Page 7
Pipe with insulation

Page 8
Pipe with insulation

Di mm 168.3
Do mm 160.3
λ W/mC 76
L m 1
R mC/W 0.00010

arak hesap edilir)

Page 9
Pipe with insulation

Page 10

You might also like