You are on page 1of 40

new build

standard
construction
drawings
2013 BUIL
REGULATI DING
COMPLIAONNS
T

d1B
aerated PART fill
Version 1.2
March 2014
All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

1 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

Welcome to

Sustainable Building Solutions (SBS) is a specialist division of the Travis Perkins Group established in
2010 to provide help, support and expert technical assistance to the construction industry.

SBS offers an integrated approach to providing solutions for your energy efficient building and renewable
energy projects. we provide the products, technical advice, specifications, services and training to enable
you to complete any sustainability project.

• Solutions – we offer New-build and Retrofit energy efficient and compliant solutions, with a fabric
first approach, supported through client and industry research.
• Services & Training – we provide many services to help you deliver your project. For details
please see pages 35 - 37.
• Products – we provide a broad range of products, from Building Fabric to Water Management,
and from Eco Materials to Renewable Energy Technologies.
• Technical Expertise – the SBS team has the support of an Advisory Board which includes BRE
and LABC.

For assistance on Sustainable Building Solutions and the products we offer, please contact :

Sustainable Helpline: 0800 688 8388

Email: helpline@tpsbs.co.uk

www.tpsbs.co.uk

Travis Perkins plc is a leading company in the builders merchant and home improvement markets and is
a main supplier to the building and construction market, one of the largest industries in the UK.

The group operates 17 businesses from more than 1,900 sites across the UK, which offer a wide range
of products and services.

© Travis Perkins plc 2011

2 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

contents
2. Welcome to SBS

4. Welcome to Standard Construction Drawings

5. Our Approach

6. How to use our Standard Construction Drawings (New Build)

9. Improvements against SAP

12. New Build Standard Construction Drawings List

33. Notes for New Build detail

34. Air Tightness Range

35. Installer training

36. Build Services

© Travis Perkins plc 2011

3
standard construction drawings D1B - aerated PART fill

OUR Standard Construction


Drawings (New Build)
With building regulations changing regularly and the efficiency of buildings becoming a higher priority
within these changes, achieving the right new-build or retrofit solution at an acceptable cost can be a
challenge.

To help the construction industry reduce these costs we have produced a series of future proof standard
construction details to help housebuilders maximise the contribution of the fabric of a building in SAP.

D1A New Build Aerated Full Fill


D1B New Build Aerated Part Fill
D1C New Build Aggregate Full Fill
D1D New Build Aggregate Part Fill

Each of the construction details uses standard construction techniques and materials, which are
assembled in carefully planned detail to minimise the thermal conductivity.

Why use these Details?


• Independently verified by BRE and LABC standard construction drawings D1B - aerated PART fill

SBS 33.2
Aerated Block

• Accepted by your local building control officer


Partial Fill Cavity
Suspended Ground Floor
I Beam Intermediate Floor
Timber Eaves Detail
Cold Roof
External Wall

• Significantly reduced Thermal Bridging


• Requires very simple changes to standard building methods
• No significant increase in build cost for contractors
• Removes the need to use default SAP values
• Available as CAD drawings
All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

• Products specified in the plans are uniquely coded and are


4

available from Travis Perkins


• Saves time and cost for the architect

Availability
The entire series of details is available to purchase in DWG format for £50 (Price includes VAT and valid
until 31st December 2014. Check website for current price).

To purchase
Call 0800 688 8388. Email your interest to helpline@tpsbs.co.uk and we will call back within 48 hours.

© Travis Perkins plc 2011

4 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

Our approach
The approach we took to create the Standard Construction Details:

• Standard brick and block construction for the first details with a maximum 100mm cavity
• Carefully analysed commercial case for all components, delivering the optimum balance of cost
versus contribution to SAP
• Developed the details and sections in 80 cross sections from foundation to just above the eaves
• With the help of the BRE selected 88 junctions to detail and model to show the biggest gain
against the Accredited values in Appendix R within SAP 2009/2012
• Reduced our thermal bridging for the property and applied these in two test houses: a two-
RWP RWP

Landing

bedroom mid and end terrace of 80m2, and a three-bedroom detached property of 113m2
Master E.E.L
Bedrm 3
Bedroom E.E.L

SD

A/C

• Tested and passed all details within SAP, across all building orientations around the compass,
from North to South
Bedrm 2
E.E.L

Bath rm.
En-suit

All the following psi-values have been calculated by a suitably competent thermal bridging modeller
RWP RWP

using the conventions as set out in “BR 497 - Conventions for calculating linear thermal transmittance
and temperature factors”, and in accordance with “IP1/06 - Assessing the effects of thermal bridging at
junctions and around openings”, by the BRE.

Bedroom 2 Bedroom 2 Bedroom 2


762 /267

762/ 267

762/ 267

A/C A/C A/C


Bathroom Bathroom Bathroom
762 762/ 762/ 762 762/ 762

Landing Landing Landing

12 21 21

11 11 11
762/ 267

762 /267

762 /267

10 01 01

9 9 9

8 8 8

7 7 7

6 6 6

5 5 5

4 4 4

Bedroom 1 3 3
Bedroom 1 3
Bedroom 1
2 2 2

1 1 1

RWP RWP

Landing

Master E.E.L
Bedrm 3
Bedroom E.E.L

SD

A/C

Bedrm 2
E.E.L

Bath rm.
En-suit

RWP RWP

Mid Terraced Unit 80.3m2


End Terraced Unit 80.3m2
Detached Dwelling 113m2

© Travis Perkins plc 2011


Bedroom 2 Bedroom 2 Bedroom 2

5
762 /267

762/ 267

762/ 267
standard construction drawings D1B - aerated PART fill

HOW TO USE OUR


STANDARD CONSTRUCTION
DRAWINGS (NEW BUILD)
To gain the benefits from our construction drawings an architect has to include our wall construction
details within their own bespoke designs. The SAP Assessor then benefits from our outstanding psi
values within their SAP Assessment.

HOUSE BUILDER SELF-BUILDER:


Share with your
Architect
Why? It should save you money!

ADAPT YOUR EXISTING


HOUSE TYPES TO USE
OUR SOLUTION AND
BUILD SMARTER AT
LOWER COST
Why? Housebuilders have typically saved
around £2,500 in build costs per property by
using the details

Ask SBS for help with maximising the


performance of your designs whilst saving
money.

© Travis Perkins plc 2011

6 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

ARCHITECT SAP ASSESSOR:


Share with your
Architect
Why? It will be easier to pass
SAP 2012
ARCHITECT USES
OUR SPECIFIED WALL Why? It’s fully product specified,
CONSTRUCTION IN with outstanding psi values, and
a menu of flexible options to
THEIR OWN DESIGN achieve Building Regulations

Why? Our psi values are


SAP ASSESSOR USES significantly better than default
OUR PSI VALUES values under SAP2012

Why? The details maximise the


BUILDING PASSES fabric performance meaning low
build costs and running costs.
SAP2012 AT LOWER Ask for more details.
COST WITH A BETTER
BUILD

© Travis Perkins plc 2011

7
standard construction drawings D1B - aerated PART fill

Flexible solutions for hitting


new build 2013 Part L
We have developed a series of options which make it easy for you to pass Building Regulations 2013.

3.0
OPTION 1 + + +
Standard Flue Gas Heat Recovery Air Permeability Mechanical
Construction Details combi boiler 231875 3.0m³(m²/y) @ 50Pa Ventilation 903712

3.0
OPTION 2 + + +
Standard 89% efficient boiler Air Permeability Water Recovery
Construction Details 289741 3.0m³(m²/y) @ 50Pa Heater 418063

5.0
OPTION 3 + + +
Standard 89% efficient boiler Air Permeability Solar Thermal
Construction Details 289741 5.0m³(m²/y) @ 50Pa 118974

5.0
OPTION 4 + + +
Standard 89% efficient boiler Air Permeability Photovoltaic Panel
Construction Details 289741 5.0m³(m²/y) @ 50Pa 889334

5.0
OPTION 5 + +
Standard Air Permeability Air Source Heat
Construction Details 5.0m³(m²/y) @ 50Pa Pump 132218

+ +
6.0
OPTION 6 +
Standard Air Permeability Valliant Ground Door u-value
Construction Details 6.0m³(m²/y) @ 50Pa Source Heat Pump 1.1W/m²K

© Travis Perkins plc 2011

8 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

Improvements against SAP


The Standard Construction Drawings have generated substantial improvements against standard SAP
Accredited values for Linear Thermal Transmittance and they far exceed any other values published.

The Standard Construction Details can only be submitted with the new ψ – values if the build is exactly
as shown as using the products specified.

Any deviation makes the figures void, including using products that have a better U-Value.

Example Improvements: Aerated Block Partial fill


Thermal Junction Accredited ψ (W/mK) Travis Perkins Standard
% Improvement
Appendix K Details ψ (W/mK)
Gable Wall - ψ 0.240 ψ 0.048 80%
Ceiling Junction
Party Wall - External ψ 0.060 ψ 0.037 38%
Wall Junction
Window Head and ψ 0.300 ψ 0.129 57%
Lintel Junction
Intermediate Floor - ψ 0.070 -ψ 0.001 101%
External Wall Junction
Ground Floor - External ψ 0.160 ψ 0.032 80%
Wall Junction
Party Wall - ψ 0.120 ψ 0.037 77%
Ceiling Junction
Party Wall - Ground ψ 0.160 ψ 0.045 72%
Floor Junction

Notes:
ψ (W/mK) = Linear Thermal Transmittance
Programme used = PHYSIBEL TRISCO 12.0 software as used by the BRE and following the conventions in BR497.

© Travis Perkins plc 2011

9
standard construction drawings D1B - aerated PART fill

U-Value Calculations & Standard


Construction Drawings for Aerated
Blocks and Suspended floors
This table shows that by using our drawings for aerated blocks and suspended floors you are
able to achieve an overall pass for the dwelling. All test data is based on our test houses, which
are shown on page 5.

Element House Type


Version Detached Mid Terrace End Terrace
Worst Orientation, SW or SE SW or SE SW/S/SE
front facing
Walls u-value 0.26 0.26 0.26
Party Walls u-value N/A 0.00 0.00
Floors u-value 0.14 (120mm PIR) 0.12 (120mm PIR) 0.13 (120mm PIR)
Roof u-value 0.10 0.10 0.10
Window type, whole window D.G, 1.20 and 0.70 D.G, 1.20 and 0.70 D.G, 1.20 and 0.70
U-Value and glazing g-value
Patio/French doors u-value D.G, 1.20 and 0.70 D.G, 1.20 and 0.70 D.G, 1.20 and 0.70
Doors u-value 1.80 1.80 1.80
Detailing y-value 0.037 0.047 0.039
Airtightness 6.0 5.0 5.0
Ventilation Natural and fans Natural and fans Natural and fans
Boiler – 24i system 89.2% eff. 12i systems 88.8% eff. 18i system 88.8% eff.
Worcester Greenstar (SEDBUK 2009) (SEDBUK 2009) (SEDBUK 2009)
Controls Programmer, thermostat and Programmer, thermostat and Programmer, thermostat and
TRV’s TRV’s TRV’s
HW Store size/losses 180l / 1.40 kWh/day 120l / 1.00 kWh/day 120l / 1.00 kWh/day

TER SAP 2009 20.17 17.35 19.66


DER SAP 2009 19.13 17.08 19.09

SAP rating B82 B83 B82

© Travis Perkins plc 2011

10 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

U-Value Calculations & Standard


Construction Drawings for Aerated
Blocks and Solid floors
This table shows that by using our drawings for aerated blocks and solid floors you are able to
achieve an overall pass for the dwelling. All test data is based on our test houses, which are
shown on page 5.

Element House Type


Version Detached Mid Terrace End Terrace
Worst Orientation, SW or SE SW or SE SW/S/SE
front facing
Walls u-value 0.26 0.26 0.26
Party Walls u-value N/A 0.00 0.00
Floors u-value 0.14 (120mm PIR) 0.11 (120mm PIR) 0.13 (120mm PIR)
Roof u-value 0.10 0.10 0.10
Window type, whole window D.G, 1.20 and 0.70 D.G, 1.20 and 0.70 D.G, 1.20 and 0.70
U-Value and glazing g-value
Patio/French doors u-value D.G, 1.20 and 0.70 D.G, 1.20 and 0.70 D.G, 1.20 and 0.70
Doors u-value 1.80 1.80 1.80
Detailing y-value 0.038 0.047 0.037
Airtightness 6.0 5.0 5.0
Ventilation Natural and fans Natural and fans Natural and fans
Boiler – 24i system 89.2% eff. 12i systems 88.8% eff. 18i system 88.8% eff.
Worcester Greenstar (SEDBUK 2009) (SEDBUK 2009) (SEDBUK 2009)
Controls Programmer, thermostat and Programmer, thermostat and Programmer, thermostat and
TRV’s TRV’s TRV’s
HW Store size/losses 180l / 1.40 kWh/day 120l / 1.00 kWh/day 120l / 1.00 kWh/day

TER SAP 2009 20.17 17.35 19.66


DER SAP 2009 19.13 17.02 19.09

SAP rating B82 B83 B82

© Travis Perkins plc 2011

11
standard construction drawings D1B - aerated PART fill

NEW BUILD STANDARD


CONSTRUCTION DRAWINGS LIST
Page Drawing
Number
13. SBS 33.2 Aerated Part Fill Suspended I Beam Timber Eaves Cold Roof External
14. SBS 34.2 Aerated Part Fill Suspended I Beam Timber Eaves Habitable External
15. SBS 35.2 Aerated Part Fill Suspended I Beam Brick Eaves Cold Roof External
16. SBS 37.2 Aerated Part Fill Suspended I Beam Gable End Cold Roof External
17. SBS 38.2 Aerated Part Fill Suspended I Beam Gable End Cold Roof Party
18. SBS 39.2 Aerated Part Fill Suspended Solid Timber Eaves Cold Roof External
19. SBS 40.2 Aerated Part Fill Suspended Solid Timber Eaves Habitable External
20. SBS 41.2 Aerated Part Fill Suspended Solid Brick Eaves Cold Roof External
21. SBS 43.2 Aerated Part Fill Suspended Solid Gable End Cold Roof External
22. SBS 44.2 Aerated Part Fill Suspended Solid Gable End Cold Roof Party
23. SBS 45.2 Aerated Part Fill Solid I Beam Timber Eaves Cold Roof External
24. SBS 46.2 Aerated Part Fill Solid I Beam Timber Eaves Habitable External
25. SBS 47.2 Aerated Part Fill Solid I Beam Brick Eaves Cold Roof External
26. SBS 49.2 Aerated Part Fill Solid I Beam Gable End Cold Roof External
27. SBS 50.2 Aerated Part Fill Solid I Beam Gable End Cold Roof Party
28. SBS 51.2 Aerated Part Fill Solid Solid Timber Eaves Cold Roof External
29. SBS 52.2 Aerated Part Fill Solid Solid Timber Eaves Habitable External
30. SBS 53.2 Aerated Part Fill Solid Solid Brick Eaves Cold Roof External
31. SBS 55.2 Aerated Part Fill Solid Solid Gable End Cold Roof External
32. SBS 56.2 Aerated Part Fill Solid Solid Gable End Cold Roof Party

© Travis Perkins plc 2011

12 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 33.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
I Beam Intermediate Floor
Timber Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

13
standard construction drawings D1B - aerated PART fill

SBS 34.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
I Beam Intermediate Floor
Timber Eaves Detail
Habitable Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

14 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 35.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
I Beam Intermediate Floor
Brick Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

15
standard construction drawings D1B - aerated PART fill

SBS 37.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
I Beam Intermediate Floor
Gable End
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

16 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 38.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
I Beam Intermediate Floor
Gable Detail
Cold Roof
Party Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

17
standard construction drawings D1B - aerated PART fill

SBS 39.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
Timber Intermediate Floor
Timber Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

18 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 40.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
Timber Intermediate Floor
Timber Eaves Detail
Habitable Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

19
standard construction drawings D1B - aerated PART fill

SBS 41.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
Timber Intermediate Floor
Brick Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

20 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 43.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
Timber Intermediate Floor
Gable End
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

21
standard construction drawings D1B - aerated PART fill

SBS 44.2
Aerated Block
Partial Fill Cavity
Suspended Ground Floor
Timber Intermediate Floor
Gable Detail
Cold Roof
Party Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

22 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 45.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
I Beam Intermediate Floor
Timber Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

23
standard construction drawings D1B - aerated PART fill

SBS 46.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
I Beam Intermediate Floor
Timber Eaves Detail
Habitable Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

24 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 47.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
I Beam Intermediate Floor
Brick Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

25
standard construction drawings D1B - aerated PART fill

SBS 49.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
I Beam Intermediate Floor
Gable End
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

26 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 50.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
I Beam Intermediate Floor
Gable Detail
Cold Roof
Party Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

27
standard construction drawings D1B - aerated PART fill

SBS 51.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
Timber Intermediate Floor
Timber Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

28 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 52.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
Timber Intermediate Floor
Timber Eaves Detail
Habitable Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

29
standard construction drawings D1B - aerated PART fill

SBS 53.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
Timber Intermediate Floor
Brick Eaves Detail
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

30 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SBS 55.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
Timber Intermediate Floor
Gable End
Cold Roof
External Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

31
standard construction drawings D1B - aerated PART fill

SBS 56.2
Aerated Block
Partial Fill Cavity
Solid Concrete Ground Floor
Timber Intermediate Floor
Gable Detail
Cold Roof
Party Wall

All Details must be read in conjunction with notes on page 33 © Travis Perkins plc 2011

32 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

Notes for New Build Detail


Notes to be used in conjunction with cad drawings
• Insulation within the internal gable wall should always be taken up to ridge level to future proof
the property for the possibility of the roof void being used as a habitable space.
• Damp Proof Course should be sealed to the Damp Proof Membrane at ground floor level.
• Additional insulation should be installed around the perimeter of the floor and continued up to
the bottom of the plasterboard at ground floor level.
• Gable wall and Intermediate Floor requires adequate restraint straps.
• All Party Wall psi values apply to both dwellings.

© Travis Perkins plc 2011

33
standard construction drawings D1B - aerated PART fill

Air Tightness
These products help to reduce the air leakage throughout a dwelling.

Tapes
Tescon Profil
Tescon Profil is a single sided adhesive tape for junctions at windows, doors and
for corner bonding.

Contega PV
Contega PV is a high quality tape, used for connections to un-plastered masonry

Sealants
Orcon F
The Orcon F joint adhesive is for joining junctions to building components

Internal Membranes
Intello
The Intello is a high performance vapour membrane which provides a degree
of protection from structural damage, even under extreme weather conditions.

External Membranes
Solitex UD
The Solitex UD is an external membrane cover fleece which acts as a roof lining
membrane and provides insulation.

Solitex Plus
The Solitex Plus improves the overall strength of the membrane and guarantees the resistance from nails
or feet, when used as a roof lining membrane or sarking membrane.

© Travis Perkins plc 2011

34 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

our training courses


PPL Training
• SBS has partnered with PPL Training, one of the
UK’s largest renewable energy training
providers

• Courses recognised for MCS membership

• Training locations throughout the UK or at your


local branch

• Pay on your account

COURSES
Below are some of the training courses we provide:
• Renewables
Solar PV
Heat Pumps
Solar Hot Water
Biomass
Mechanical Ventilation with Heat Recovery
Under-floor Heating
• Build
Electrical & Wiring
Water Regulations
Plumbing
• Water Management
Grey Water Reuse & Rainwater Harvesting

For more information:


Contact PPL Training: 0800 688 8388
Email: helpline@tpsbs.co.uk
www.tpsbs.co.uk

ELC
PROVIDER NO.
2662

© Travis Perkins plc 2011

35
standard construction drawings D1B - aerated PART fill

SBS SERVICES
BUILDING CONTROL
All New Build projects require certification under
Building Regulations by a BCB/Licensed Inspector
• Building Regulations set standards for design
and construction which apply to many
alterations to existing buildings
• SBS works in partnership with licensed
inspectors to provide complete solutions to
your build

For more details visit www.tpsbs.co.uk


or call 0800 688 8388

ASSESSMENT & CERTIFICATION


Obtaining approval for retrofit is now more time consuming with an array of assessments and testing
required. SBS has partnered with Energy Review to offer a one stop shop to help developers and
contractors in meeting the wide range of statutory obligations imposed.

Services detailed below can be ordered individually or expanded to a full consultancy service:

• SAP Energy Assessment & EPC


• Code for Sustainable Homes
• Air Tightness Testing
• Acoustic Testing
• Ecology Assessment
• Flood Risk Assessment

For more details visit


or call

© Travis Perkins plc 2011

36 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

SITE SURVEY & DESIGN


Many new technologies require specific knowledge and experience to design the best
system to meet the needs of the property or properties.
Our team of technical experts will undertake site
assessment and will design and deliver
a bespoke solution to minimise
installation costs and
maximise performance.
Tailoring a solution that properly
takes account of ground conditions
and site constraints will provide long-term
efficiencies.

Services include:
• Sustainable Drainage Design
• Ground Source Heat Pumps Surveying
• Geotechnical & environmental assessment
• Renewable assessment & investigation
• Waste Material management plan

For more details visit www.tpsbs.co.uk or call 0800 688 8388

RENEWABLES HEATING DESIGN


Designing the optimum renewables system for a particular site can be challenging for end users and
installers. The experts at SBS can help
you by providing a detailed system plan,
and product list, to help deliver the most
efficient solution for your building.
Services include:

• Solar Thermal System Design


• Air Source Heat Pumps
• Biomass Heating System
• Central Heating System Design

For more details visit


www.tpsbs.co.uk or call 0800 688 8388

© Travis Perkins plc 2011

37
standard construction drawings D1B - aerated PART fill

estimating service
more building, less number-crunching

your estimates are clear, your quotes


are competitive, WE SAVE YOU MONEY
• Speak to an expert before you start your new building project
• Send in plans by email or hand them in at your local branch
• No surprises - our estimating service tells you what your project will cost
• The more you order the more discount you will be eligible for
• Dedicated estimating team will answer all your queries
• Review and fine-tune your estimate in branch

Contact us:
01604 592507
Email:
estimating@travisperkins.co.uk

© Travis Perkins plc 2011

38 www.tpsbs.co.uk
standard construction drawings D1B - aerated PART fill

© Travis Perkins plc 2011

39
contact information

Sustainable Helpline:
0800 688 8388
Email:
helpline@tpsbs.co.uk
www.tpsbs.co.uk

Scan this QR code with your smartphone to go to our website.


You will need to download any free QR reader app onto your smartphone.

Registered Office: Lodge Way House, Lodge Way, Northampton. NN5 7UG
Registered in England 824821
The information contained in this publication is believed to be correct and complete at the time of printing. Due to
limitations in the printing process images may not be representative of their true colours and colour variations may
occur due to the natural origin of the products. Stock may vary from branch to branch and is subject to availability.
All photographs are as a guide only and do not necessarily represent the products available. Travis Perkins plc
reserves the right to change product details without prior notice. Errors & omissions excluded. All products sold
subject to Travis Perkins Terms & Conditions of Sale. Travis Perkins plc is the owner of the registered trademark
Travis Perkins. JB77341.02 01/14