You are on page 1of 4

TRIAL MIX FOR ADHIMIX PRECAST

PURPOSE
Compare Existing Product Kao Mighty 150S vs TAM Cem 53

.
DESIGN MIX
- Grade K600 , No Fly Ash , target slump 1flow, No dust

Grade K600 Mix I Mix II Mix III

Cement Indocement 485 485 0


Fly Ash 0 0 0
Split Intermix 5/26 1086 1086 0
Sand Bangka 676 676 0
Dust 0 0 0
Water 155 155 0
Kao Mighty 150 S ( ltr ) 6.8
TAM Cem 53 ( ltr ) 3.54 0

TRIAL MIX METHODE

-Target slump for all Mix flow ( 550 x 550 ) mm


- Slump loss check after 30 ‘ and 60’
- Cylinder sample per mix 6 pieces , compressive strength test 2 sample 12 hours
and 2 sample 3 days , than 2 sample for 28 days
-2 Sample for compressive strength will be steam curing for +/- 6 hours
TRIAL MIX PICTURE

TAM Cem 53 Split 5/26 Intermix Bangka Sand Indocement OPC

Weighting Mixing Measuring Recording


TRIAL MIX RESULT

SLUMP LOSS

Slump
loss Mix I Mix II
Initial
Slump 55x55 60x60
After 30’ 45x45 60x60
After 60' n/a 50x50

COMPRESSIVE STRENGTH

C. Strength Mix I Mix II

12 hours 252 215

3 days
28 days

WATER CEMENT RATIO

w/c Mix I Mix II W/C Ratio Actual TAM CEM 53 to get


The same performance initial slump , less
0.21 0.20 Than used Existing Product

ADMIXTURE DOSAGE

Dosage Mix I Mix II


TAM Cem 53 more powerfull product,
Dosage around half than Existing product
1.4% 0.7%
SUMMARY TRIAL MIX

1. Tam Cem 53 give good performance for water reducer, slump loss, and
setting time.

2. Tam Cem 53 , with the new technology polymer make concrete easier
to work, and give better performance for surface.

3. Need to re-check for air entrained in concrete , cause TAM CEM 53 give
higher result than Existing Product

4. Fine tune for dosage and w/c, to get the compressive strength specification
for 12 hours.

5. Tam Cem 53 : Recommended for SCC ( Self Compacting Concrete )