Professional Documents
Culture Documents
Approval Sheet
Name Tittle Date Signature
Eka Yudha El Nur Asst. Manager Engineering & Planning SF
Ari Antono Project Lead / Rotating Engineer
Revision : B
W2021C-PHEWMO-PHE32-M-DSH-0001 Page 2 of 12
CONTRACT NO. : 4710002866
INSTALLATION ON PHE-32
INSTALLATION ON PHE-32
3 COMPONENT MOL %
4 Nitrogen 0,83
5 CO2 0,530
6 H2S 0,000
7 Methane 83,430
8 Ethane 6,580
9 Propane 4,450
10 i-Butane 1,110
11 n-Butane 1,290
12 i-Pentane 0,470
13 n-Pentane 0,330
14 n-Hexane 0,240
15 n-Heptane 0,160
16 n-Octane 0,060
17 n-Nonane 0,010
18 n-Decane 0,000
19 n-C11 0,000
20 H2O 0,520
21
22
23
24
25 TOTAL
26 AVG. MOL. WT.
27 SITE DATA: NOISE SPECIFICATIONS:
28 LOCATION: APPLICABLE TO MACHINE:
29 INDOOR HEATED UNDER SHELTER SEE SPECIFICATION PHEWMO-PHE32-M-SPE-0003 Spec. for
30 OUTDOOR UNHEATED PARTIAL SIDES Wellhead Compressor Package
31 GRADE MAIN DECK OFFSHORE APPLICABLE TO NEIGHBORHOOD:
32 WINTERIZATION REQ'D. TROPICALIZATION REQ'D. SEE SPECIFICATION
33 ELEVATION TBA ft BAROMETER - (bar abs.) ACOUSTIC HOUSING: YES NO
34 RANGE OF AMBIENT TEMPS: DRY BULB WET BULB SOUND LEVEL 85 dB @ 1 m
35 SITE RATED OF dB RE: 20 MICRO PASCAL
O
36 NORMAL F APPLICABLE SPECIFICATIONS:
O 95
37 MAXIMUM F API 618, RECIPROCATING COMPRESSOR FOR GENERAL REFINERY
O 90
38 MINIMUM F SERVICES.
39 ELECTRICAL AREA CLASSIFICATION:
40 AREA: ZONE 2 GR. IIA TEMP. CLASS T3
41 UNUSUAL CONDITIONS: DUST FUMES
42 OTHER MARINE ENVIRONMENT
43 PAINTING:
44 OTHERS PHEWMO-PROJ-H-PRC-0007 Specification for
45 VENDOR HAVING UNIT RESPONSIBILITY: Protective Coating
46 SHIPMENT:
47 DOMESTIC EXPORT EXPORT BOXING REQ'D.
48 LONG TERM STORAGE FOR 6 MONTHS
49
50 REMARKS:
51
CONTRACT NO. : 4710002866
INSTALLATION ON PHE-32
1 CONSTRUCTION FEATURES
2 SPEEDS: SHAFT:
3 MAX. CONT. RPM TRIP RPM MATERIAL AS PER API 618
4 MAX. TIP SPEEDS: ft/s @ MAX. OPER. SPEED DIA @ ROTOR (inch) DIA @ COUPLING (inch)
5 MIN. ALLOW RPM SHAFT END: TAPERED CYLINDRICAL
6 LATERAL CRITICAL SPEEDS: SHAFT SLEEVES :
7 FIRST CRITICAL AS PER API 618 RPM AT SHAFT SEALS MAT'L AS PER API 618
8 DAMPED UNDAMPED TIMING GEARS:
9 MODE SHAPE PITCH LINE DIAMETER (inch) MALE: FEMALE:
10 LATERAL CRITICAL SPEED - BASIS: MATERIAL
11 DAMPED UNBALANCE RESPONSE ANALYSIS SHAFT SEALS:
12 OTHER TYPE ANALYSIS: (Specify) SEAL SYSTEM TYPE
13 POCKET PASSING FREQUENCY: Hz OIL LEAKAGE (CC/MIN/SEAL)
14 TORSIONAL CRITICAL SPEEDS: TYPE BUFFER GAS
15 FIRST CRITICAL RPM BUFFER GAS FLOW (PER SEAL)
16 SECOND CRITICAL RPM NORMAL: lb/hr. @ (psig)
17 VIBRATION: MAX.: lb/hr. @ (psig)
18 HOUSING mm/s RMS BEARING HOUSING:
19 SHAFT TYPE (SEPARATE, INTEGRAL) SPLIT
20 ROTATION, LOOK AT COMPRESSOR DRIVEN END: CW CCW MATERIAL AS PER API 618
21 CASING: HYDRODYNAMIC RADIAL BEARINGS: (IDENTIFY HIGHEST LOADED BEARING)
22 MODEL TYPE SPAN (inch)
23 CASING SPLIT AREA (ft2) LOADING (lb/inch2): ACT. ALLOW.
24 MATERIAL AS PER API 618 CLADDING NO.PADS ROTOR ON OR BETWEEN PADS
25 OPERATION: DRY FLOODED, w/ LIQUID PAD MATERIAL
26 THICKNESS (inch) CORR. ALLOW. (inch) TYPE BABBITT THICKNESS (inch)
27 MAX. ALLOWABLE WORKING PRESS. (psig) TEMP SENSORS
28 RELIEF VALVE SETTING (psig) TC RTD TYPE
29 MARGIN FOR ACCUMULATION (psig) NO PER BRG
30 LEAK TEST GAS: PRESS. (psig) ROLLING ELEMENT RADIAL BEARING
31 TEST PRESS.(bar): HYDRO TYPE: Ndm:
O O
32 MAX. ALLOW. TEMP. F MIN. OPER. TEMP. F ENERGY DENSITY (kW-RPM):
33 COOLING JACKET YES NO HYDRODYNAMIC THRUST BEARING: (IDENTIFY HIGHEST LOADED BEARING)
34 ROTORS: TYPE
35 DIAMETER (inch): MALE: FEMALE: MFR. AREA (ft2)
36 NO. LOBES: MALE: FEMALE LOADING (lb/inch2) ACT. ALLOW.
37 TYPE: NUMBER OF PADS
38 TYPE FABRICATION PAD MATERIAL
39 MATERIAL TYPE BABBITT THICKNESS (inch)
40 MAX. YIELD STRENGTH (psig) TEMP SENSORS
41 BRINELL HARDNESS. MAX. MIN. TC RTD TYPE
42 ROTOR LENGTH TO DIAMETER RATIO (L/D) M: NO PER BRG ACTIVE INACTIVE
43 ROTOR CLEARANCE (inch)
44
45 INTERNALLY COOLED YES NO
46
47 REMARKS:
48 1. * VENDOR TO CONFIRM / ADVISE ; VENDOR TO ADVISED ON BLANK ITEM.
49 2. VENDOR TO ADVISE TYPE OF BEARING WHICH WILL BE USED BASED ON API 618.
50
51
52
53
CONTRACT NO. : 4710002866
INSTALLATION ON PHE-32
INSTALLATION ON PHE-32
INSTALLATION ON PHE-32
INSTALLATION ON PHE-32
11 MISCELLANEOUS INSTRUMENTATION:
12 DRIVER START/ STOP LOCAL PANEL SEPARATE PANEL MAIN BOARD
13 SIGHT FLOW INDICATORS, EACH JOURNAL & THRUST BEARING & EACH COUPLING OIL RETURN LINE
14 SIGHT FLOW INDICATORS, EACH SEAL OIL RETURN LINE
15 LEVEL GAGES, LUBE AND/OR SEAL OIL RESERVOIR, S.O. DRAIN TRAPS & S.O. OVERHEAD TANK
16 VIBRATION AND SHAFT POSITION PROBES & PROXIMITORS
17 VIBRATION AND SHAFT POSITION READOUT EQUIPMENT
18 VIBRATION READOUT LOCATION ON: LOCAL PANEL SEPARATE PANEL MAIN BOARD
19 TURBINE SPEED PICKUP DEVICES
20 GEAR SPEED INDICATORS
21 GEAR SPEED INDICATORS LOCATION ON: LOCAL PANEL MAIN BOARD
22 REMOTE HAND SPEED CHANGER - MOUNTED ON LOCAL PANEL
23 ALARM HORN & ACKNOWLEDGEMENT SWITCH
24
25 ALARM & SHUTDOWN SWITCHS: PRE-
26 FUNCTION ALARM TRIP FUNCTION ALARM TRIP
27 LOW LUBE OIL PRESSURE Y Y TURBINE VIBRATION
28 HI LUBE OIL FILTER ΔP Y TURBINE AXIAL POSITION
29 HI SEAL OIL FILTER ΔP Y GEAR VIBRATION
30 LOW LUBE OIL RESERVOIR LEV. Y GEAR AXIAL POSITION
31 LOW SEAL OIL RESERVOIR LEV. COMPRESSOR MOTOR SHUTDOWN
32 HI SEAL OIL LEVEL Y TRIP & THROTTLE VALVE SHUT
33 LOW SEAL OIL LEVEL Y HI TURB. STEAM SEAL LEAKAGE
34 HI SEAL OIL PRESSURE HI COMP. THRUST BRG. TEMP. Y Y
35 LOW SEAL OIL PRESSURE HI COMP. JOURNAL BRG. TEMP.
36 AUX. SEAL OIL PUMP START HI DRIVER THRUST BRG TEMP. Y Y
37 AUX. LUBE OIL PUMP START HI DRIVER JOURNAL BRG TEMP.
38 HI SEAL OIL OUTLET TEMP. (COOLER) HI GEAR THRUST BRG. TEMP.
39 HI LIQUID LEV. SUCT. SEPARATOR HI GEAR JOURNAL BRG. TEMP.
40 COMPRESSOR VIBRATION Y Y COMPRESSOR ΔP Y Y
41 COMPRESSOR HI DISCH. TEMP. Y Y LOW SEAL GAS PRESSURE ΔP Y Y
42 COMPRESSOR AXIAL POSITION Y HI COALESCING GAS/OIL FILTER ΔP Y
43 HI LUBE OIL SUPPLY TEMPERATURE Y
44 REMARK: VENDOR TO CONFIRM/ ADVISE THE FUNCTIONS STATUS REQUIRED CONSIDERING AVAILABILITY AND APPLICABILITY OF
45 ALARM SIGNALS IN ACCORDANCE WITH THE NEEDS OF THE PACKAGE.
46 CONTACS:
47 ALARM CONTACTS SHALL: OPEN CLOSE TO SOUND ALARM AND BE NORMALLY ENERGIZED DE-ENERGIZED
48 SHUTDOWN CONTACTS SHALL: OPEN CLOSE TO TRIP AND BE NORMALLY ENERGIZED DE-ENERGIZED
50 MISCELLANEOUS:
51 INSTRUMENT TAGGING REQUIRED.
52 ALARM AND SHUTDOWN SWITCHES SHALL BE SEPARATE.
53 PURCHASERS ELECTRICAL & INSTRUMENT CONNECTIONS WITHIN THE CONFINES OF THE BASEPLATE AND CONSOLE
54 SHALL BE: BROUGHT OUT TO TERMINAL BOXES. MADE DIRECTLY BY THE PURCHASER.
55 COMMENTS REGARDING INSTRUMENTATION: ALL SKID FIELD INSTRUMENTS SHALL BE WIRED AND TERMINATED INSIDE
56 TERMINAL BOX PART OF LOCAL CONTROL PANEL.
CONTRACT NO. : 4710002866
PROJECT NAME : ENGINEERING STUDY OF WELLHEAD COMPRESSOR
INSTALLATION ON PHE-32
EQUIPMENT NAME : WELLHEAD COMPRESSOR PACKAGE
DATA SHEET NO. : W2021C-PHEWMO-PHE32-M-DSH-0001 REV. : B
TAG NO. : PHE-32-WHC-321 QTY. : ONE (1)
DATA SHEET FOR GAS ENGINE DRIVER
SPECIFICATION NO. : PHEWMO-PHE32-M-SPE-0003 PAGE : 11 OF 12
ENGINE OPERATING DATA
1 DRIVEN EQUIPMENT : RECIPROCATING COMPRESSOR 6 DUTY : 8 CONTINUOUS
6 INTERMITTENT
2 MAKE OR TYPE : * 7 POWER REQUIREMENTS : 120 VAC, 60 Hz ; 24 VDC
3 ABSORBED POWER : * 8 STARTING REQUIREMENTS : ELECTRICAL (BATTERY)
4 SPEED RPM : * 9 TYPE OF ENGINE : 4 CYCLE
5 ROTATION FROM DRIVEN END : CW CCW * 10
SITE CONDITIONS UTILITIES AVAILABLE
11 o
LOCATION OFFSHORE, MAIN DECK 18 COOLING WATER TEMP.MIN. F NOT REQUIRED
12 o
ALTITUDE ft TBA 19 COOLING WATER TEMP.MAX. F NOT REQUIRED
13 BAROMETRIC PRESSURE psia TBA 20 COOLING WATER PRESS.MIN. psig NOT REQUIRED
14 o
AMBIENT TEMPERATURE MAX/MIN F 95 / 60 21 COOLING WATER PRESS.MAX. psig NOT REQUIRED
15 RELATIVE HUMIDITY % 100 22 NATURE OF WATER NOT REQUIRED
16 ATMOSPHERIC CONDITIONS CORROSIVE,SALT LADEN 23 ELECTRIC SUPPLY 480 VAC, 60 Hz
17 AREA CLASSIFICATION UNCLASSIFIED 24 AIR AVAILABLE 130 psig UTILITY AIR
ENGINE DATA
25 MANUFACTURER : * 39 COMPONENTS MATERIAL
26 MODEL NO: * TYPE: * CYCLE: * 40 CYLINDER LINERS 8 YES
6 NO
*
27 DEVELOPED POWER AT SITE CONDITIONS : * 41 WET DRY
28 MAXIMUM : * AT * RPM 42 MAIN BEARINGS NO : * DIA (in) *
*
29 CONDITIONS : * *AT RPM 43 TYPE: *
30 ASPIRATION : NATURALLY OR TURBOCHARGED 44 CONN. ROD BEARINGS DIA (in) : *
*
31 NO.OF CYLINDERS : * ARRANGEMENT : * 45 TYPE: *
32 BORE/STROKE : * DISPLACEMENT * 46 WRIST PIN DIA (in) * *
33 VALVES PER CYLINDER INLET : * EXHAUST : * 47 PISTON RINGS NO. * COMP. * OIL * *
34 PISTON SPEED AT RATED (RPM) : * 48 PISTONS ALLOY CI COMPOSITE *
35 COMPRESSION RATIO : * 49 CRANKCASE : *
36 THERMAL EFFICIENCY : * 50 VALVES AND SEATS : *
37 FUEL RATES : * 51 CYLINDER HEAD : *
38 LUBE OIL CONSUMPTION : * 52
ENCLOSURE (Note 2)
53 ENCLOSURE CLASS : NEMA-4X, T3 & CLASS 1 DIV 2 GR. D 59 FIRE PROTECTION : GAS DETECTOR ON ENCLOSURE OUTLET
54 SOUND PROOF WATER PROOF 60 ADJUSTABLE DAMPER YES NO
55 PRESSURIZED BY : INLET FANS 61 LIGHTING YES NO
56 MAX DIFFERENTIAL PRESSURE : 0.5 inch H2O 62 MAX ENCLOSURE TEMPERATURE : 105 oF
57 NUMBER OF INLET FANS : 2 63 INSTRUMENTATION : OUTLET TEMPERATURE TRANSMITTER
58 RUNNING UNIT STAND BY UNIT 64 DIFFERENTIAL PRESSURE GAUGE
STARTING SYSTEM
65 HAND STARTER/INERTIA STARTER YES NO 71 PNEUMATIC STARTER YES NO
66 ELECTRIC MOTOR WITH BATTERIES YES NO 72 DRIVEN BY :
67 BATTERY TYPE : * 73 MAKE TYPE :
68 RATING : * 74 AIR RECEIVER: YES NO
69 CHARGING EQUIPMENT : YES 75 TAG NO : CAPACITY *
70 BLACK START SYSTEM : YES NO 76 WORKING PRESSURE / TEMPERATURE (psig / oF) :
IGNITION SYSTEM LUBE SYSTEM
77 LOW TENSION : * 89 RESERVOIR : *
78 HIGH TENSION : * 90 CAPACITY : * RETENTION TIME : *
79 MAGNETO : * 91 MAIN OIL PUMP :
80 SOLID STATE : * 92 MAKER : * DRIVER : ENGINE SHAFT
81 SINGLE IGNITION SYSTEM * 93 CAPACITY * PRESSURE : *
82 DOUBLE IGNITION SYSTEM * 94 AUXILIARY/PRE-LUBE PUMP YES NO
83 BREAKERLESS : * 95 MAKER : * DRIVE : *
84 SHIELDED : * 96 CAPACITY : * PRESSURE : *
85 HAZARD CERTIFICATION * 97 FILTERS No. : 2 (DUAL) TYPE : REPLACEABLE PAPER
86 98 MAKER : *
87 99 FILTRATION SIZE : 10 MICRON
88 100 HEATER TYPE : * kW * Volts
NOTES :1. * Vendor to confirm or advise
2. Gas Engine and Compressor are installed in this enclosure.
CONTRACT NO. : 4710002866
PROJECT NAME : ENGINEERING STUDY OF WELLHEAD COMPRESSOR
INSTALLATION ON PHE-32
EQUIPMENT NAME : WELLHEAD COMPRESSOR PACKAGE
DATA SHEET NO. : W2021C-PHEWMO-PHE32-M-DSH-0001 REV. : B
TAG NO. : PHE-32-WHC-321 QTY. : ONE (1)
DATA SHEET FOR GAS ENGINE DRIVER
SPECIFICATION NO. : PHEWMO-PHE32-M-SPE-0003 PAGE : 12 OF 12
COOLING SYSTEM ACCESSORIES
1 ENGINE COOLING AIR WATER 19 EXHAUST SILENCER YES NO TYPE : *
2 COOLING TYPE RADIATOR SHELL & TUBE 20 EXHAUST MANIFOLD YES NO
3 PLATE 21 INLET SILENCER YES NO
4 COOLING WATER REQ'D : * 22 INLET AIR FILTER YES NO
5 FAN DRIVE VEE BELT ELECTRIC 23 MAKER : *
6 HYDRAULIC SHAFT 24 PRESS.CHARGER TYPE IF FITTED : (*) TURBO LOBE OTHER
7 MAKE UP TANK CAPACITY : * 25 MAKER : *
8 MAKER : * LOCATION : * 26 GEARBOX RATIO IF FITTED * AGMA RATIO : *
9 COOLING WATER PUMP TYPE : * 27 COUPLING TYPE : DRY-FLEXIBLE
10 MAKER : * DRIVER : 28 MAKER : *
11 CAPACITY : * PRESSURE (psig) : 29 BARRING GEAR : : YES NO
12 OIL COOLERS YES NO NUMBER : * 30 SPARK ARRESTER : YES NO
13 LOCATION : * 31 ENGINE MOUNTING :
14 INTERCOOLER : (*) YES NO LOCATION : * 32 FONDATION BOLT : YES NO
15 THERMOSTAT No. : * MAKER : * 33 FLAME ARRESTER : INLET EXHAUST
16 JACKET WATER HEATER YES NO 34 INLET DRY AIR CLEANER : YES NO
17 PISTON COOLING OIL JET DRILLED ROD 35
18 UNCOOLED * 36
CONTROL & SAFETY DEVICES INSTRUMENTATION
37 GOVERNOR SPEED CONTROL CONSTANT VARIABLE 52 INSTRUMENT PANEL YES NO
38 SPEED RANGE RPM : * GOVERNING CLASS : * 53 LOCATION : LOCAL PANEL
39 SPEED GOVERNOR TYPE MECHANICAL HYDRAULIC 54 OIL TEMPERATURE GAUGE YES NO
40 ELECTRONIC 55 OIL PRESSURE GAUGE YES NO
41 MAKER : * 56 WATER TEMPERATURE GAUGE YES NO
42 ENGINE PROTECTION : SETTING 57 AMMETER YES NO
43 LOW LUBE OIL PRESS ALARM TRIP */* 58 TACHOMETER YES NO
44 HIGH WATER TEMP. ALARM TRIP */* 59 HOURS RUN METER YES NO
45 HIGH OIL TEMP. ALARM TRIP */* 60 MANIFOLD PRESSURE GAUGE YES NO
46 EXCESSIVE VIBRATION ALARM TRIP */* 61 MANIFOLD AIR TEMPERATURE YES NO
47 OVERSPEED ALARM TRIP */* 62 EXHAUST TEMPERATURE YES NO
48 INTAKE SHUT OFF VALVE YES NO 63 STARTING AIR PRESSURE YES NO
49 CRANKCASE RELIEF VALVE : * 64 BATTERY VOLTS METER YES NO
50 ANNUNCIATOR PANEL : YES NO 65 FUEL PRESSURE YES NO
51 LOCATION : LOCAL PANEL & CONTROL ROOM 66
FREQUENCY METER YES NO
FUEL GAS SPECIFICATION
o
67 TEMPERATURE F 120 80 GAS COMPOSITION : (cont'd)
68 PRESSURE psig 60 81 NITROGEN MOL % 0,83
69 STD.GAS FLOW MMSCFD 0,5 82 METHANE MOL % 83,43
70 ACT.GAS FLOW ACFM * 83 ETHANE MOL % 6,58
71 MASS FLOW lb/hr 4.467 84 PROPANE MOL % 4,45
72 MOLECULAR WEIGHT 20.30 85 I-BUTANE MOL % 1,11
73 MASS Cp Btu/lb-oF 0,51 86 n- BUTANE MOL % 1,29
74 THERMAL COND. Btu/hr-ft-oF 0,019 87 I- PENTANE MOL % 0,47
75 VISCOSITY cP 0,014 88 n-PENTANE MOL % 0,33
76 MASS DENSITY lb/ft3 0,417 89 n-HEXANE MOL % 0,24
90 n-HEPTANE MOL % 0,16
91 n-Octane MOL % 0,06
77 GAS COMPOSITION : 91 n-Nonane MOL % 0,01
78 H2S MOL % 0,00 91 n-C11 MOL % 0,00
79 CO2 MOL % 0,53 92 H2O MOL % 0,52
INSPECTION AND TESTING REQUIRED WITNESS WEIGHT
93 SHOP INSPECTION YES * 99 ENGINE lb *
94 MECHANICAL RUN YES * 100 RADIATOR lb *
95 PERFORMANCE RUN YES * 101 EXHAUST SYSTEM/SILENCER lb *
96 COMBINED TEST YES * 102 DRIVEN EQUIPMENT lb *
97 OTHER YES * 103 HEAVIEST MAINTENANCE LIFT lb *
98 104