Service Report

To: Mr.Surendran (Approved Forensics Sdn Bhd)


Date: 28/09/2021 Item Type: PCB Complete Item Half enclosed Item
Status: Problem Found
Item Brand: Printing body contouring machine
Info: Model: AS70004 RF Board, AS30150-S10 Main Board, AS30000-S10 Gui Board
S/N: Nil
Faulty: AS30000-S10 Gui Board Main IC damage

Applied Tests:

 Check all Passive components


 To check the power circuit
 Check main microcontroller IC.
 Check capacitor ESR value and micro farad value.
 Use Dc power supply and check all the power circuit supplies.
 Use DMM check all basic components.

Equipment Used:

 Agilent 16903A Logic Analyzer


 ABI Op-AMP Tester
 ABI Digital IC Tester
 Multi meter digital.
 DC Power supply.

1
SMT ELECTRONIC
INVESTIGATION:

1. To check the incoming power circuit with external Dc power supply.


2. To check the capacitor ESR value ok for AS70004 RF Board, AS30150-S10 Main Board are ok.
3. Take out the AS30000-S10 Gui Board main module PCB card and inject supply, the Main board
IC get over heat.
4. Externally inject 5VDC and test the main control IC temperature level was high and fault
led was occur.
5. AS70004 RF Board, AS30150-S10 Main Board both PCB board condition are good, no any
damages.
6. The problem we found is AS30000-S10 Gui Board main control module IC damage.

2
SMT ELECTRONIC
Attached photo show the unit status:

AS70004 RF Board

All components are tested good.


3
SMT ELECTRONIC
AS30150-S10 Main Board

4
SMT ELECTRONIC
5
SMT ELECTRONIC
All components and supply are in good conditions.

6
SMT ELECTRONIC
AS30000-S10 Gui Board

7
SMT ELECTRONIC
When inject supply from enterally fault LED triggered.

8
SMT ELECTRONIC
9
SMT ELECTRONIC
Assessment and diagnose:

1). AS30000-S10 Gui Board Main Microcontroller IC output pin shorted.

10
SMT ELECTRONIC
11
SMT ELECTRONIC