Job Safety Analysis Sheet: Erection & Use of Scaffolding
Job Safety Analysis Sheet: Erection & Use of Scaffolding
JOB DESCRIPTION: Erection & Use of Scaffolding JSA Ref. No. JSA / KOC / 07
PERSONAL PROTECTIVE EQUIPMENT: Hard Hat, Safety Shoes, Hand Gloves, Safety Harness.
SEQUENCE OF
Yes /
BASIC JOB POTENTIAL HAZARDS PRECAUTIONS
No
STEPS
Location of Emergency
Ensure the emergency equipment will not be blocked or
Equipment near the proposed
damaged due to scaffolding erection.
Scaffolding
Non-compliance of KOC - Refer Chapter -13 of KOC F & S Regulations, HSEMS
Pre – Work HSEMS Procedures, F & S Procedure Doc. No. SA.KOC.002 ‘Control & Use of
Regulations & Engineering Scaffolding, & Recommended Practice KOC – L – 025
Standards “Scaffolding”
Unauthorized erection of
Obtain the Cold Work Permit.
scaffolding
Damage to onsite detectors / Take extreme care during erection and override it if
switches / transmitters etc needed.
Provide guardrail & toe board to prevent falling of tools /
objects.
Don’t keep the unnecessary materials on the scaffold
Fall of objects / Tools. platform.
Hand tools to be tied with permanent structure or
person.
If required barricade the area during erection work.
The Scaffolder must use Safety Harness to prevent
Accidental Fall of Person
accidental fall .
Erection & Use of The scaffold must be inspected, certified & tagged by
Unstable Scaffold
Scaffolding the competent person confirming its suitability.
The scaffold tag must indicate the maximum load that it
Weak Scaffold
can bear.
The scaffolding is to be inspected at least weekly for
Damaged Scaffold any damage due to weather condition (rain, high wind
etc) or other unsafe conditions.
In case of any modification, addition in the scaffold, it
Modified Scaffold
has to be re-inspected & certified.
Ensure Scaffold is securely supported on a rigid ground
Improperly Supported Scaffold
and not on process piping / vessel or equipment.
Do not use if green Tag is missing.
Incomplete Scaffold
Do not use if red tag is available.
Do not use if it does not have valid inspection tag
Old Scaffolding Doubtful Integrity
attached.
Additional
Hazards
(Other than
indicated above)