You are on page 1of 16

SICAM PAS

C
©
Version: HR_Page 1
Software Installation
and
Licensing

Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
Software Overview

TCC
XXX
SCC

C
© PAS
Config

Version: HR_Page 2
IEDs
3rd Party

Siemens Power Academy TD


IEDs
DiGSI

05 Licensing
SICAM PAS - Complete
PAS
Config

Energy Sector
Different kinds of Software on different PCs

SICAM PAS, V7.0 for SAS Station Server and Gateway

C
©
Version: HR_Page 3
WinCC V7 for HMI System

DIGSI 4.84 for Siemens Protection Relays and Bay Controllers


Systemconfigurator is included (Third Party ICD Files -> SCD Files)

Engineering PC:
+ PCM 600 Tool for ABB Relay,
+Software for Hopf 6842 and
+ ALSTOM Devices

Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
C
©
Version: HR_Page 4
SICAM PAS
Software Installation

Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
Setup Dialog Boxes

C
© Everything is already
checked by default
Version: HR_Page 5
Licensed

Siemens Power Academy TD


Full Server or DIP
05 Licensing
SICAM PAS - Complete Energy Sector
C
©
Version: HR_Page 6
SICAM PAS
Licensing

Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
Dongle and Passwords

 To operate SICAM PAS, a dongle and a password list for the optional
applications are necessary.

C
©  The dongle has to be plugged on an USB port of the PAS computer
(or Station Unit). A parallel port version is also available.

 The dongle comes together with a password list, which contains


passwords for all bought applications.

 Later, to add an application, just buy the additional password.

 In Server-DIP-configurations we need several different dongles for


Full Server and DIPs.

Version: HR_Page 7 Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
How to open the Feature Enabler

The Feature Enabler releases those


applications, which we want to run on
the PAS computer

C
©
Version: HR_Page 8 Siemens Power Academy TD
05 Licensing
SICAM PAS - Complete Energy Sector
Feature Enabler

C
©
Version: HR_Page 9 Siemens Power Academy TD
Depending of the usage of the
PAS PCs at least the
configuration license and/or the
runtime license should be
entered.

Almost all other applications are


communication services and
depend on the desired
functionality.

05 Licensing
SICAM PAS - Complete Energy Sector
How to install passwords

To enable a certain
application, a password

C
© The installation just takes a few seconds.

Version: HR_Page 10 Siemens Power Academy TD


has to be entered.
A unique password list comes
along with the Dongle.

05 Licensing
SICAM PAS - Complete Energy Sector
Parameterization without configuration license

Even if you have no configuration license but a runtime license you can do some
(limited)parameterization in the UI-Configuration tool.

C
© You can add new applications, mainly für PQS applications. In this case IEC 103 and
IEC61850 protocols belong to these applications.

With all the other applications you can:

 not connect new devices or interfaces


 not delete devices or interfaces aber alle anderen
 change parameters
 add new information

Version: HR_Page 11 Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
License models

You can run SICAM PAS PQS in two modes:

C
©  Demo version – Without dongle

 License version – With Dongle(s)

Version: HR_Page 12 Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
SICAM PAS PQS V7.0 - Demo

Demo version (without Dongle)


In the demo version SICAM PAS/PQS runs as single system (no DIPs). After 3 hours
all protocoll drivers and the central server stop running, the configuration manger is still

C
© running.
After each restart of your PC the demo version runs the next 3 hours.

The following restrictions are valid:

 Projects which you have created with the demo version can not be used in the full
version
 SICAM PAS/PQS in demo version can not run as a distributed system (no DIP)
 There can be saved only 1 fault record per device in the archive. Furthermore you
can save only PQ data for one day.

Version: HR_Page 13 Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
SICAM PAS PQS - License

License version
With the license version SICAM PAS/PQS can run as a single system or as DIP(s).

C
© The following restrictions are valid:

 You can use only these services which you have activated with the valid license
key and the appropriate dongle.

Version: HR_Page 14 Siemens Power Academy TD


05 Licensing
SICAM PAS - Complete Energy Sector
License key

C
© Licenses for SICAM PAS Basic functions
Licenses for PQS
Licenses for communication from/to IEDs
Licenses for Kommunikation from/to control center
Version: HR_Page 15 Siemens Power Academy TD
05 Licensing
SICAM PAS - Complete Energy Sector
License sizes

Runtime Configuration Remarks

Large Large unlimited

C
©
Version: HR_Page 16
Medium

Small

SmallMedium

MediumLarge

Siemens Power Academy TD


Medium

---------

----------

MediumLarge
Up to 15 devices
(Infos unlimited)
Or up to 2000 Infos
(devices unbegrenzt)

Up to 4 devices
(Infos unlimited)

Upgrade

Upgrade

05 Licensing
SICAM PAS - Complete Energy Sector