You are on page 1of 2

Compone Name Fuel (F) Product(s) (P)

nt
1. PhotoVoltai F1=B˙0 P1=B˙20
c Plant
2. Electricity F2=B˙19+B˙20+B˙23 P2=B˙24
Distribution
3. Internal F3=B˙1 ICE electricity
Combustio P3,el=B˙19
n Engine
ICE heat
P3,Q=B˙3−B˙4
4. Gas Boiler F4=B˙25 P4=B˙26−B˙27
5. Heat Tank F5=B˙7−B˙8 P5=B˙9−B˙10
6. Heat F6=B˙9−B˙10 Heat for
Distribution Consumers
Unit P6,HC=B˙11−B˙
12
Heat for AD
P6,AD=B˙13−B˙
14
7. Adsorption F7=B˙13−B˙14 P7=B˙15−B˙16
Chiller
8. Useful Heat F8=F8,4+F8,6=(B˙11−B˙12)+ P8=B˙28−B˙29
Distribution (B˙26−B˙27)
Some fuels and products of the system are heat flows. For the assumed temperature of water
(Table 3.35) exergy can be calculated by means of quality coefficients. The quality
coefficients ψi (Carnot efficiencies) for heat flows within the system are summarized
in Table 3.37.
Table 3.37. Quality of heat flows.

Component Name Fuel (F) Product(s) (P)


3. Internal Combustion Engine N/A ψP3= 0.1839
4. Gas Boiler N/A ψP4= 0.1570
5. Heat Tank ψF5= 0.1838 x  → ψP5= 0.1765
0

x  → ψP5= 0.1801
1

6. Heat Distribution Unit x  → ψF6= 0.1765 Heat for Consumers


0

x  → ψF6= 0.1801 ψP6,HC= 0.1570
1

Heat for AD
ψP6,AD= 0.1955
7. Adsorption Chiller ψF7= 0.1955 ψP7= 0.0190
Component Name Fuel (F) Product(s) (P)
8. Useful Heat Distribution ψF8= 0.1570 ψP8= 0.1570
Results of TEA and TEC analysis for momentary parameters in the reference
state x0 (100% ICE load and solar exergy flux Bß = 1000 W/m2) and in the operational
state x1 (load of ICE = 70% and solar exergy flux Bß = 200 W/m2) are presented
in Tables 3.38 and 3.39, respectively.
Table 3.38. Results of exergy, exergy cost and thermo-ecological cost (TEC) analysis for the reference state (x ;
0

ICE = 100%; Bß =