You are on page 1of 22

TECHNICAL STACKABLE VALVES

OFF-HIGHWAY
CATALOGUE MACHINERY
DIRECTIONAL CONTROL
ARON 2005
STACKABLE VALVES
ABBREVIATIONS
AP HIGH PRESSURE CONNECTION
AS PHASE LAG (DEGREES)
BP LOW PRESSURE CONNECTION
C STROKE (MM)
CH ACROSS FLATS
CH INTERNAL ACROSS FLATS
DA AMPLITUDE DECAY (DB)
DP DIFFERENTIAL PRESSURE (BAR)
F FORCE (N) PROPORTIONAL CONTROL
I% INPUT CURRENT (A) STACKABLE VALVE
M MANOMETER CONNECTION
CDC.3.*.E...
NG KNOB TURNS
CH. XI PAGE 3
OR SEAL RING
CD.3.*.E...
P LOAD PRESSURE (BAR)
CH. XI PAGE 5
PARBAK PARBAK RING
A09 DC COIL
PL PARALLEL CONNECTION
CH. XI PAGE 8
PR REDUCED PRESSURE (BAR)
D15 DC COIL
Q FLOW (L/MIN)
CH. XI PAGE 8
QP PUMP FLOW (L/MIN)
"LE" VARIANT FOR CDC... / CD...
SE ELASTIC PIN
CH. XI PAGE 9
SF BALL
STUDS AND FIXING FEET
SR SERIES CONNECTION CX.3...
CAP. XI PAGE 10
X PILOTING CH. XI PAGE 11
Y DRAINAGE PROPORTIONAL SOLENOID D15P
Incorrect use of the products described in CH. XI PAGE 13
this catalogue may cause harm to personnel CXQ.3...
and equipment. The technical information MODULAR CH. XI PAGE 14
given for each product in this catalogue may
STACKABLE VALVE D15P PROPORTIONAL SOLENOID
be subject to variation, and the manufacturer
reserves the right to make constructional CH. XI PAGE 15
modifications without giving prior notice. STUDS AND FIXING FEET
Each product presented, its data, features
CAP. XI PAGE. 10
and technical specifications must therefore
be examined and checked by members of
the user's staff (possessing suitable technical
knowledge) taking into consideration the
intended use of product. INLET AND OUTLET MODULE UNITS
The user must, in particular, assess the FOR STACKABLE VALVES
operating conditions of each product in
relation to the application that he intends to
use it for, analysing the data, features and
technical specifications in view of the
proposed applications, and ensuring that, in
use in the product, all of the conditions
CM02.3.P...
relating to the safety of personnel and
equipment, also in the event of breakdown, CH. XI PAGE 16
are respected. CM.3.M...
CH. XI PAGE 17

FI.3...
CAP. XI PAGE. 10
FE02.3...
CH. XI PAGE 19
PLANT AND HEAD OFFICE FE10.3...
CH. XI PAGE 20
42100 Reggio Emilia (Italy)
FE10.P.3...
1, Via Natta (Z.I. Mancasale)
CH. XI PAGE 21
Tel. (+39) 0522.50.58
FE.3...
Fax. (+39) 0522.50.58.56
CH. XI PAGE 22
Web pages www.aron.it
FU...
E-mail: uff.comm@aron.it
CH. XI PAGE 22

File: E11ETA
uff.tecnico@aron.it

07/2000/e 11
CDC.3.*.E...
DIRECTIONAL CONTROL STACKABLE VALVE OFF-HIGHWAY
Directional control stackable valve body is available in two different sizes:
MACHINERY
G3/8" or 9/16-18UNF (SAE 6).
The operation of the directional valve is electrical. The centring is achieved by means of
calibrated length springs which immediately reposition the spool in the neutral position when
the electrical signal is shut off. To improve the valve performance, different springs are used
for each spool.
The solenoids, constructed with a protection class of IP65 in accordance with BS 5490
standards, are available in direct current form and different voltage. The electrical controls are
CDC.3.*.E... equipped with an emergency manual control inserted in the tube.
INDIVIDUAL VALVE CH. XI PAGE 3 The electrical supply connectors meet DIN 43650 ISO 4400 standards. On request, could be
STACKABLE VALVES CH. XI PAGE 4 available the following coil connec-
tion variants: AMP Junior connec- Max. pressure ports P/A/B/T 250 bar
A09 DC COIL CH. XI PAGE 8
tions; flying leads connections, with Max flow 30 l/min
"LE" VARIANT CH. XI PAGE 9 or without integrated diode; Deutsch Max excitation frequency 3 Hz
SCREWS AND STUDS CH. XI PAGE 10 connections with bidirectional inte- Duty cycle 100% ED
STANDARD CONNECTORS CH. I PAGE 19 grated diode. Fluid viscosity 10 ÷ 500 mm2/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight with one DC solenoid 1,25 Kg
ORDERING CODE TAB.1 - BODY TYPE Weight with two DC solenoids 1,5 Kg
A Ports G3/8" parallel
CDC Directional control
stackable valve B Ports 9/16 - 18UNF parallel
D* Ports G3/8" series TAB.2 - STANDARD SPOOLS
3 Size E* Ports 9/16 - 18UNF series TWO SOLENOIDS,SPRING CENTRED "C" MOUNTING
G Attachment style, parallel Spool Covering Transient position
* Body type (tab. 1) presetting for modular valves type

H* Attachment style, series 01 +


E Electrical operator presetting for modular valves
(*) For series connection configuration 02 -
** Spool (tab.2) see note below ordering code
For series connection 03 +
use spool 04 only
TAB.4 - A09 - DC VOLTAGE 04* -
* Mounting (tab.3) L 12V 115Vac/50Hz
M 24V 120Vac/60Hz
ONE SOLENOID, SIDE A "E" MOUNTING
* Voltage (tab.4) N 48V* with rectifier
P 110V* 230Vac/50Hz
Spool Covering Transient position

** Variants (tab.5) Z 102V* 240Vac/60Hz type


X 205V* with rectifier
01 +
W Without DC coils
1 Serial No.
* Special voltage 02 -

• The AMP Junior coil and with the flying 03 +


For series connection leads (with or without diode) coils are avail-
configuration, a special able in 12V or 24V DC voltage only. 04* -
individual stackable valve • The Deutsch coil with bidirectional diode
CDC.3.*.E.04.**.PT.1 (A B or G is available in 12V DC voltage only. 15 -
parallel body type only, with
spool 04 type, PT variant) must 16 +
always be used as first element. TAB.5 - VARIANTS TABLE
For other individual stackable valve VARIANT CODE
must use body D E or H connector ONE SOLENOID, SIDE B "F" MOUNTING
series type with spool 04 only. No variant 00
Spool Covering Transient position
Viton V1
type
Emergency button E1
TAB.3 MOUNTING Rotary emergency button P1 01 +
STANDARD Solenoid valve without connectors S1
First element for series connection PT 02 -
C Pilot light X1
Rectifier R1 03 +
E Viton + Pilot light VX
Viton + Rectifier VR 04* -
F Pilot light + Rectifier XR
coils with flying leads (length 250 mm) FL 15 -
SPECIALS (WITH PRICE INCREASING) coils with flying leads (length 130 mm)
and integrated diode LD 16 +
G AMP Junior connection AJ
Deutsch connection and bidr. diode CX
* SPOOL WITH PRICE INCREASING
H Other variants relate to a special design

11 File: ECDC3001 XI • 2 05/2001/e


CDC.3.*.E... DIRECTIONAL CONTROL STACKABLE VALVE
OFF-HIGHWAY
MACHINERY
OVERALL DIMENSIONS
E = Manual override

PRESSURE DROPS
DIRECTIONAL CONTROL STACKABLE VALVE
10
1
Connections The diagram at the side shows
2 Spool the pressure drop curves for
type P→A P→B A→T B→T P→T P/ T passing spools during normal usage.
3 The fluid used is a mineral oil with
4 01 4 4 4 4 / 9
02 (p*) 7 7 6 6 7 9 a viscosity of 46 mm2/s at 40 C°;
∆p (bar)

5
02 (s*) 7 7 6 6 8 / the tests have been carried out at
6 a fluid temperature of 40 C°.
7 03 4 4 6 6 / 9
04 (p*) 2 2 1 1 5 9
8
04 (s*) 2 2 1 1 3 /
9 15-16 F 6 6 5 10 / 9
15-16 E 6 6 10 5 / 9
(p*) Parallel connections
Q (l/min) Curve No. (s*) Series connections

LIMITS
The tests have been carried out with solenoids at operating temperature
1 and a voltage 10% less than rated voltage with a fluid temperature of 50
Spool n° C°. The fluid used was a mineral oil with a viscosity of 46 mm2/s at 40
2
type curve degrees C. The values in the diagram refer to tests carried out with the
3 oil flow in two directions simultaneously (e.g. from P to A and at the same
01 1
02 1 time B to T).
P (bar)

03 3 In the cases where valves 4/2 and 4/3 are used with the flow in one
04 2 direction only, the limits of use could have variations which may
4 15-16 1(4*) even be negative (See curve No 4 and Spool No 16 used as 2 or 3
ways). The tests were carried out with a counter-pressure of 2 bar
at T port.

Q (l/min)
(4*) = 15 and 16 spools used as 2 or 3 way, follow the curve n°4

File: ECDC3001 XI • 3 05 /2001/e 11


STACKABLE DIRECTIONAL CONTROL VALVES
OFF-HIGHWAY
MACHINERY
HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION
PARALLEL CONNECTION

SERIES CONNECTION Special element


CDC.3.*.E.04.**.PT.1

Special closing plug

For series connection configuration, a special individual valve


bank section (CDC.3.*.E.04.**.PT.1) must always be used as first
element (see ordering code)

OVERALL DIMENSIONS
Tighten the screws to a torque of 5 Nm

FE02-FE INLET MODULE FE 10 INLET MODULE


LENGTH LENGTH
NO. ELEMENTS C (mm) D C (mm) D
2 192 180 202 190
3 238 226 248 236
4 284 272 294 282
5 330 318 340 328
6 376 364 386 374

11 File: ECDC3001 XI • 4 05/2001/e


CD.3.*.E... DIRECTIONAL CONTROL
STACKABLE VALVE WITH D15 COILS OFF-HIGHWAY
Directional control stackable valve body is available in two different sizes: MACHINERY
G3/8" or 9/16-18UNF (SAE 6).
The operation of the directional valve is electrical. The centring is achieved by means of
calibrated length springs which immediately reposition the spool in the neutral position when
the electrical signal is shut off. To improve the valve performance, different springs are used
for each spool. The solenoids, constructed with a protection class of IP66 in accordance with
DIN 40050 standards, are available in direct current form and different voltage. The electrical
supply connectors meet DIN 43650 ISO 4400 standards; AMP Junior, AMP Junior and
integrated diode, flying leads, Deutsch DT 04 - 2P coil type, connectors are also available with
CD.3.*.E... built in rectifiers or pilot lights.
Max. pressure ports P/A/B/T 250 bar
INDIVIDUAL VALVE CH. XI PAGE 6 Max flow 40 l/min
STACKABLE VALVES CH. XI PAGE 7 Max excitation frequency 3 Hz
D15 DC COIL CH. XI PAGE 8 Duty cycle 100% ED
Fluid viscosity 10 ÷ 500 mm2/s
"LE" VARIANT CH. XI PAGE 9
Fluid temperature -25°C ÷ 75°C
SCREWS AND STUDS CH. XI PAGE 10 Ambient temperature -25°C ÷ 60°C
STANDARD CONNECTORS CH. I PAGE 19 Max contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight with one DC solenoid 1,389 Kg
Weight with two DC solenoids 1,778 Kg
ORDERING CODE TAB.1 - BODY TYPE
A Ports G3/8" parallel TAB.2 - STANDARD SPOOLS
CD Directional control
stackable valve B Ports 9/16 - 18UNF parallel TWO SOLENOIDS,SPRING CENTRED "C" MOUNTING
(with D15 coil) D* Ports G3/8" series Spool Covering Transient position
type
E* Ports 9/16 - 18UNF series
3 Size G Attachment style, parallel 01 +
presetting for modular valves
* Body type (tab. 1) 02 -
H* Attachment style, series
presetting for modular valves
E Electrical operator (*) For series connection configuration see note below
03 +
ordering code
04* -
** Spool (tab.2)
For series connection TAB.4 - D15 COIL (DC - 30W)
use spool 04 only ONE SOLENOID, SIDE A "E" MOUNTING
L 12V 115Vac/50Hz
M 24V 120Vac/60Hz Spool Covering Transient position
* Mounting (tab.3) type
V 28V* with rectifier
N 48V* 01 +
* Voltage (tab.4) Z 102V* 230Vac/50Hz
P 110V* 240Vac/60Hz
02 -
** Variants (tab.5) X 205V* with rectifier

W Without DC coils or connectors 03 +


Voltage codes are not stamped on the plate, their are
1 Serial No. readable on the coils.
* Special voltage 04* -

For series connection • AMP Junior (with or without diode) and 15 -


configuration, a special Deutsch and with flying leads coils, are
individual stackable valve available in 12V or 24V DC voltage only. 16 +
CD.3.*.E.04.**.PT.1 (A B or G • Plastic type coils are available in 12V,
parallel body type only, with 24V, 28V or 110V DC voltage only.
spool 04 type, PT variant) must ONE SOLENOID, SIDE B "F" MOUNTING
always be used as first element.
For other individual stackable valve
TAB.5 - VARIANTS TABLE Spool Covering Transient position
type
must use body D E or H connector VARIANT CODE
series type with spool 04 only. 01 +
No variant 00
Viton V1
02 -
TAB.3 MOUNTING Pilot light X1
Rectifier R1
STANDARD 03 +
Emergency button E1
C Rotary emergency button P1
Solenoid valve without connectors S1 04* -

E First element for series connection PT


AMP Junior connection AJ 15 -
AMP Junior and integrated diode AD
F Coil with flying leads (length 175 mm) SL 16 +
Coil with Deutsch DT04-2P conn. CZ
SPECIALS (WITH PRICE INCREASING) * SPOOL WITH
Palstic type coil BR PRICE INCREASING

G Viton + Pilot light VX


Viton + Rectifier VR
Pilot light + Rectifier XR
H
Other variants relate to a special design

File: ECD3001 XI • 5 04/2002/e 11


CD.3... DIRECTIONAL CONTROL STACKABLE VALVE WITH D15 COILS
OFF-HIGHWAY
MACHINERY

E = Manual override

PRESSURE DROPS
DIRECTIONAL CONTROL STACKABLE VALVE
1 2

3 Connections The diagram at the side shows


4
Spool the pressure drop curves for
type P→A P→B A→T B→T P→T P/ T passing
5 spools during normal usage.
01 4 4 4 4 / 9 The fluid used is a mineral oil with
02 (p*) 5 5 5 5 7 9 a viscosity of 46 mm2/s at 40 C°;
6
∆p (bar)

02 (s*) 5 5 6 6 8 / the tests have been carried out at


7 03 4 4 5 5 / 9 a fluid temperature of 40 C°..
8 04 (p*) 1 1 2 2 5 9
04 (s*) 5 5 4 4 6 /
9 15-16 F 5 3 5 2 / 9
15-16 E 3 5 2 5 / 9
(p*) Parallel connections
Q (l/min) Curve No. (s*) Series connections

LIMITS
1 The tests have been carried out with solenoids at operating temperature
and a voltage 10% less than rated voltage with a fluid temperature of 50
2 Spool n° C°. The fluid used was a mineral oil with a viscosity of 46 mm2/s at 40
type curve degrees C. The values in the diagram refer to tests carried out with the
01 1 oil flow in two directions simultaneously (e.g. from P to A and at the same
02 1 time B to T).
P (bar)

03 1 In the cases where valves 4/2 and 4/3 are used with the flow in one
3 04 2 direction only, the limits of use could have variations which may
15 3 even be negative (See curve No 4 and Spool No 16 used as 2 or 3
16 1(3*) ways). The tests were carried out with a counter-pressure of 2 bar
at T port.

Q (l/min) (3*) = 16 spools used as 2 or 3 way, follow the curve n°3

11 File: ECD3001 XI • 6 04/2002/e


CD.3... DIRECTIONAL CONTROL STACKABLE VALVE WITH D15 COILS
OFF-HIGHWAY
MACHINERY
HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION
PARALLEL CONNECTION

SERIES CONNECTION Special element


CD.3.*.E.04.**.PT.1

Special closing plug

For series connection configuration, a special individual valve


bank section (CD.3.*.E.04.**.PT.1) must always be used as first
element (see ordering code)

OVERALL DIMENSIONS
Tighten the screws to a torque of 5 Nm

FE02-FE INLET MODULE FE 10 INLET MODULE


LENGTH LENGTH
NO. ELEMENTS C (mm) D C (mm) D
2 192 180 202 190
3 238 226 248 236
4 284 272 294 282
5 330 318 340 328
6 376 364 386 374

File: ECD3001 XI • 7 04/2002/e 11


DC COILS A09 FOR CDC.3...
Type of protection • The AMP Junior coil and with the
(in relation to connector used) IP 65 flying leads (with or without diode)
Number of cycle 18.000/h coils are available in 12V or 24V
Supply tolerance ±10% DC voltage only.
Ambient temperature -30°C ÷ 60°C
Duty cycle 100% ED • The Deutsch coil with
Insulation class H bidirectional diode is available in
Weight 0,215 Kg 12V DC voltage only.

VOLTAGE MAX WINDING TEMPERATURE RATED POWER RESISTANCE AT 20°C


OTHER COILS (VARIANTS) (V) (AMBIENT TEMPERATURE 25°C) (W) (OHM) ±7%
AMP JUNIOR (AJ) 12V 123°C 27 5.3
24V 123°C 27 21.3
48V* 123°C 27 85.3
102V* 123°C 27 392
110V* 123°C 27 448
205V* 123°C 27 1577
* Special voltages ETA09 - 02/2001/e

MANUAL EMERGENCY (E1) ROTARY EMERGENCY (P1)


DEUTSCH COIL WITH FLYING LEADS (FL)
BIDIR. DIODE (CX) LEADS WITH DIODO (LD)

DC COILS D15 FOR CD.3...


Type of protection • AMP Junior coils (with or without
(in relation to the connector used) IP 66 diode) and coils with flying leads
Number of cycles 18.000/h and coils type Deutsch, are
Supply tolerance ±10% available in 12V or 24V DC voltage
Ambient temperature -54°C ÷ 60°C only.
Duty cycle 100% ED • The pastic type coil (BR variant)
Insulation class H is available in 12V, 24V, 28V or
Weight 0,354 Kg 110V DC voltage only.
OTHER COILS (VARIANTI)
AMP JUNIOR (AJ) FLYING WITH LEADS VOLTAGE MAX. WINDING TEMPERATURE RATED POWER RESISTANCE AT 20°C
AMP J. WITH DIODE (AD) (V) (AMBIENT TEMPERATURE 25°C) (W) (OHM) ±10%
COIL (SL)

12V 110°C 30 4.8


24V 110°C 30 18.8
28V* 110°C 30 25.6
48V* 110°C 30 75.2
102V* 110°C 30 340
110V* 110°C 30 387
205V* 110°C 30 1375

(*) Special voltages ETD15 - 03/2001/e

DEUTSCH COIL (CZ) PLASTIC COIL (BR) MANUAL EMERGENCY (E1) ROTARY EMERGENCY (P1)
68,65
56,6

57,9

11 File: ETCA09D15 XI • 8 05/2001/e


"LE" VARIANT - EMERGENCY CONTROL LEVER FOR
STACKABLE VALVES (CDC/CD3)
OFF-HIGHWAY
The emergency control lever for solenoid valves by Aron, represents a MACHINERY
develop in terms of safety and flexibility among applied hydraulic components.
Thanks to his flexibility, the component was designed to be inserted between the valve
body and the spool, providing total interchangeability between the different types of solenoid
body valves manufactured by Aron. It is compatible with the standard CETOP 3 and stackable
valves with threaded connections –G3/8" or 9/16-18UNF (SAE 6). The component is available
for both directional control and proportional valves (for the last type of control please consult
our Technical Department)
As an emergency lever applied to solenoid valves, the control can be used as a safety
device in conformity with the industry standards , also playing an useful role in the event of
power cuts. The control can be used in agricultural and mobile fields; the manual action can
be used to carry out periodic maintenance work on mobile components of the vehicle , in
perfectly safe working conditions.

Max operating pressure port T: HYDRAULIC SIMBOL


dynamic 160 bar
static 210 bar
Max operating pressure port P
for series connection configuration 160 bar

• MOUNTING TYPE: C / F / H
• SPOOLS TYPE: 01/02/03/04/16/17/66/132

MOUNTING COMPATIBILITY
CODE VALVE DESCRIPTION COIL VOLTAGE
CDC.3... Stackable valve A09 27 W
CD.3... Stackable valve D15 30 W

OVERALL DIMENSION

CDC.3...
VERSION

CD.3...
VERSION

Support plane
specifications

File: ETLECDC3 XI • 9 01/2004/e 11


STUDS AND FIXING FEET FOR MOUNTING
OFF-HIGHWAY
MACHINERY

CDC3... CD3... WITH D15 COIL


A09 COIL
WITH CX3... CXQ3... WITH D15P COIL

Tighten the screws to a torque of 5 Nm

COMPLETE KIT OF MOUNTING


CONSISTING OF N° 4 RODS AND N° 8 STUD NUTS
CODE LENGHT (mm) COMPOSITION
V89540003 165 2 ELEMENTS WITH FE.02 or FE
V89540005 210 3 ELEMENTS WITH FE.02 or FE
V89540007 255 4 ELEMENTS WITH FE.02 or FE
V89540009 300 5 ELEMENTS WITH FE.02 or FE
V89540011 350 6 ELEMENTS WITH FE.02 or FE
V89540004 175 2 ELEMENTS WITH FE.10
V89540006 220 3 ELEMENTS WITH FE.10
V89540008 265 4 ELEMENTS WITH FE.10
V89540010 310 5 ELEMENTS WITH FE.10
V89540012 360 6 ELEMENTS WITH FE.10
FIXING FEET
CODE COMPOSITION No. PZ.
M76.15.0014 EVERYONE 2

FI.3... INTERMEDIATE MODULE UNIT


The employment of the intermediate module
unit concurs to realize stackable directional
control valves with a greater number of six
elements, being used the same ones rods
supplied in our standard kit of assembly.

ORDERING CODE
FI Intermediate module unit

3 Size

A P and T passing

** 00 = No variants
V1 = Viton Weight: 0,9 Kg

1 Serial No.

11 File: EFI3001 XI • 10 00/2002/e


CX.3.A... / CX.3.C... SOLENOID OPERATING
PROPORTIONAL CONTROL STACKABLE VALVES OFF-HIGHWAY
CX.3.A../CX.3.C.. series valves are MACHINERY
used for controlling fluid direction and
flow rate as a function of the supply
current to the proportional control so-
lenoid.
The individual valve is available in CX.3.A.01.N... CX.3.A.03.N...
two different sizes: G3/8" or 9/16-
18UNF.

CX.3.C.01.N... CX.3.C.03.N...

CX.3...
INDIVIDUAL VALVE CH. XI PAGE 12 OPERATING SPECIFICATIONS
STACKABLE VALVES CH. XI PAGE 13 Max. operating pressure ports P/A/B 250 bar
D15 DC COIL CH. XI PAGE 13 Max. operating pressure ports T - for dynamic pressure see note (*) 250 bar
Regulated flow rate 3 / 10 / 15 / 20 l/min
SCREWS AND STUDS CH. XI PAGE 10
Relative duty cycle Continuous 100% ED
REM.S.RA... CH. IX PAGE 2 Type of protection IP 65
REM.D.RA... CH. IX PAGE 5 Fluid viscosity 10 ÷ 500 mm2/s
SE.3.AN21.00... CH. IX PAGE 9 Fluid temperature -20°C ÷ 75°C
Max. contamination level class 8 in accordance with
NAS 1638 with filter ß10≥75
Weight CX.3.A... (single solenoid) 1,389 Kg
Weight CX.3.C... (double solenoid) 1,778 Kg
Max. current 2.35A 1.76 A 0.88 A
ORDERING CODE Solenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 Ohm
(*) Pressure dynamic allowed for 2 millions of cycles.
CX Proportional
control stackable valve • Operating specifications are valid for fluid with 46 mm2/s viscosity at 40°C, using the
specified ARON electronic control units.
3 Size
ELECTRONIC CONTROL UNIT
* A = Single solenoid REM.S.RA.*.*. and REM.D.RA.*.*.
C = Double solenoid Card type control for single and double solenoid
SE.3.AN.21.00...
* Body type: EUROCARD type control for single and double
A = Ports G3/8" parallel solenoid
B = Ports 9/16 - 18UNF parallel DIAGRAMS
G = Presetting for modular valves (parallel)
INPUT SIGNAL
** Type of spool CX.3.*.01.N4

01 = 03 =
Q (l/min)

N Symmetrical flow path control


(see symbols table)

* Flow rating l/min (∆p 5 bar)


1 = 3 l/min
2 = 10 l/min I (%)
3 = 15 l/min
4 = 20 l/min
POWER LIMITS TRANSMITTED
* Max. current at solenoid: CX.3.*.01.N4
E = 2.35 A
F = 1.76 A
G = 0.88 A
** 00 = No variant
P (bar)

V1 = Viton
E1 = Emergency button
P1 = Rotary emergency
The fluid used is a mineral based oil
1 Serial No. with a viscosity of 46 mm2/s at 40°C.
The tests have been carried out at with
a fluid of a 40°C. Q (l/min)

File: ECX3001 XI • 11 04/2002/e 11


CX.3... SOLENOID OPERATING PROPORTIONAL CONTROL STACKABLE VALVES
OFF-HIGHWAY
MACHINERY
OVERALL DIMENSIONS

"E1" EMERGENCY BUTTON VARIANT "P1" ROTARY EMERGENCY VARIANT

11 File: ECX3002 XI • 12 04/2002/e


CX.3... SOLENOID OPERATING PROPORTIONAL CONTROL STACKABLE VALVES
OFF-HIGHWAY
MACHINERY
HYDRAULIC SYMBOLS AND INSTRUCTION OF CONNECTION
PARALLEL CONNECTION

OVERALL DIMENSIONS
Tighten the screws to a torque of 5 Nm

FE02-FE INLET MODULE FE 10 INLET MODULE


LENGTH LENGTH
NO. ELEMENTS C (mm) D C (mm) D
2 192 180 202 190
3 238 226 248 236
4 284 272 294 282
5 330 318 340 328
6 376 364 386 374

PROPORTIONAL SOLENOID D15P


Type of protection (in relation to connector used) IP 66
Duty cycle 100% ED
Insulation class H
Weight (coil) 0,354 Kg
Weight (solenoid) 0,608 Kg
ETD15P - 00/2002/e

File: ECX3001 XI • 13 04/2002/e 11


CXQ.3... OPEN LOOP PROPORTIONAL PRESSURE
COMPENSATED STACKABLE FLOW REGULATORS OFF-HIGHWAY
The open loop proportional flow regulator 3 way compensated with priority MACHINERY
function is designed to regulate flow in proportion to an applied electrical current
(REM or SE3AN power amplifier).
Flow regulation is independent both from load – POUT port – and pump flow
variations. Load compensation is achieved by a spool compensator, which holds
the pressure drop constant across the proportional spool.
Operating specifications and overall size make
this valve suitable to interlock to module units
and stackable valves in order to combine a
DIAGRAMS
proportional control with directional control typi- INPUT SIGNAL
cal of stackable systems.
FLOW

HYDRAULIC SYMBOLS
SIMPLIFIED

Q (l/min)
CXQ.3...
D15P SOLENOID PROPORTIONAL CH. XI PAGE 15 I (%)
3 WAY WITH SECONDARY LINE
STUDS FOR MOUNTING CH. XI PAGE 10 FLOW RATE BACK PRESSURE
CXQ.3.C.T...
ON PRIORITY LINE

Q (l/min)
ORDERING CODE
CXQ Open loop 3 way
proportional compensated
flow regulator for module units
and stackable valves

3 Size 3 WAY WITH PRIORITY FUNCTION P (bar)


CXQ.3.C.P...
C 3 way compensation FLOW RATE BACK PRESSURE
ON SECONDARY LINE

* P = 3 way priority function version


T = 3 way version
(with secondary line)
Q (l/min)

* Nominal flow rates


H = 15 l/min
I = 25 l/min

D with decompression = Blind


P (bar)
* Max. current at solenoid ∆ P - PUMP FLOW
E = 2.35 A
PIN → T
F = 11.76 A
G = 0.88 A CXQ.3.C.T... CXQ.3.C.P...

** 00 = No variant
P1 = Rotary emergency
∆p (bar)

∆p (bar)

1 Serial No.

The fluid used is a mineral based oil with a


viscosity of 46 mm2/s at 40°C. The tests have
been carried out at with a fluid of a 40°C. Q (l/min) Q (l/min)

11 File: ECXQ3001 XI • 14 02/2002/e


CXQ.3... OPEN LOOP PROPORTIONAL PRESSURE
COMPENSATED STACKABLE FLOW REGULATORS OFF-HIGHWAY
MACHINERY
OPERATING SPECIFICATIONS AMPLIFIER UNIT AND CONTROL
Max. operating pressure ports Pin / Pout / E / T 250 bar REM.S.RA.*.*...
Regulated flow rate 15 / 25 l/min electronic card for control single proportional
Decompression drain flow max 0,7 l/min solenoid valve
Relative duty cycle Continuous 100% ED
Type of protection (in relation to the connector used) IP 66 SE.3.AN.21.00...
Flow rate gain See diagram "Input signal flow" EUROCARD type control for single solenoid
Fluid viscosity 10 ÷ 500 mm2/s • Operating specifications are valid for
Fluid temperature -20°C ÷ 75°C fluid with 46 mm2/s viscosity at 40°C, using
Ambient temperature -20°C ÷ 70°C the specified ARON electronic control units.
Max. contamination level from class 7 to 9 in accordance
with NAS 1638 with filter ß10≥75
Weight CXQ.3.C.P... version Kg 2,25
Weight CXQ.3.C.T... version Kg 1,75
Max. current at solenoid 2.35A 1.76 A 0.88 A
Solenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 Ohm
(*) Pressure dynamic allowed for 2 millions of cycles.

OVERALL DIMENSIONS CXQ.3.C.T... OVERALL DIMENSIONS CXQ.3.C.P...

P1 Rotary emergency button P1 Rotary emergency button

PROPORTIONAL SOLENOID D15P


Type of protection (in relation to connector used) IP 66
Duty cycle 100% ED
Insulation class H
Weight (coil) 0,354 Kg
Weight (solenoid) 0,608 Kg
ETD15P - 00/2002/e

File: ECXQ3001 XI • 15 02/2002/e 11


CM02.3.P... MODULAR PILOT OPERATED
CHECK STACKABLE VALVES OFF-HIGHWAY
CM02.3.P type modular check MACHINERY
stackable valves allow one way free
flow by raising a conical shutter, while Max. operating pressure 250 bar
in the opposite direction the fluid can Minimum opening pressure spring 1 1 bar
return by means of a small piston Minimum opening pressure spring 5 5 bar
piloted by the pressure in the other Piloting ratio: 1:4
line. Max. flow 15 l/min
Hydraulic fluids Mineral oils DIN 51524
They are available on single A or B Fluid viscosity 10 ÷ 500 mm2/s a 50°C
lines, and on double A and B lines Fluid temperature -20°C ÷ 75°C
CM02.3.P... (see hydraulic symbols ). Max. contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight 0,692 Kg

ORDERING CODE

CM02 Modular stackable valve PRESSURE DROPS HYDRAULIC SYMBOLS


(Q max 15 l/min)

3 Size
CM02.3.P.A
P Piloted check valve
∆p (bar)

r
* Port sizes: ar ba
5b 1
1 = G3/8"
3
2 = 9/16-18UNF
CM02.3.P.B
** Control on lines A / B / AB
Q (l/min)
* Minimum opening pressure
3 = Piloted side flow
1 = 1 bar
5 = 5 bar

** 00 = No variant CM02.3.P.AB
V1 = Viton

1 Serial No.

OVERALL DIMENSIONS AND MOUNTING

Fixing screws UNI 5931 M5x45


with material specification min. 8.8
Tightening torque 5 Nm / 0.5 Kgm

11 File: ECM023P001 XI • 16 02/2002/e


CM.3.M... MODULAR MAX. PRESSURE
STACKABLE VALVES OFF-HIGHWAY
CM.3.M type pressure regulating MACHINERY
valves are available with a pressure
range of 1 ÷ 290 bar. Max. operating pressure 290 bar
Adjustment is by means of a grub Setting ranges: spring 1 max. 30 bar
screw. spring 2 max. 90 bar
spring 3 max. 290 bar
Single on A or B lines, and double on Max. flow 30 l/min
AB lines versions are available, with Hydraulic fluids Mineral oils DIN 51524
drainage to T. Fluid viscosity 10 ÷ 500 mm2/s
All versions can accept three types of Fluid temperature -25°C ÷ 75°C
springs with calibrated ranges as Ambient temperature -25°C ÷ 60°C
shown in the specifications. Max. contamination level class 10 in accordance
CM.3.M... with NAS 1638 with filter ß25≥75
The cartridge, which is the same for all Weight CM.3.M.A/B... 0,698 Kg
CMP.06... CH. V PAGE 18
versions, is the direct acting type Weight CM.3.M.AB... 0,926 Kg
CMP06.
For the minimum permissible set-
ORDERING CODE ting pressure depending on the
spring, see minimum pressure set-
CM Modular stackable valve ting curve.

3 Size

M Maximum pressure valve


PRESSURE - FLOW RATE HYDRAULIC SYMBOLS
* Port sizes: 3

1 = G3/8"
2 = 9/16-18UNF

** Adjustment on the lines:


P (bar)

A / B / AB
2

C Type of adjustment 1
Grub screw CM.3.M.A

* Setting ranges at port A Q (l/min)


1 = max. 30 bar (white spring)
2 = max. 90 bar (yellow spring)
3 = max. 290 bar (green spring) MINIMUM SETTING
PRESSURE
* Setting ranges at port B
(Omit if the setting is same
3
as that at port A)
1 = max.30 bar (white spring) 2 CM.3.M.B
1
2 = max. 90 bar (yellow spring)
3 = max. 290 bar (green spring)
P (bar)

** 00 = No variant
V1 = Viton

1 Serial No.
Q (l/min)

Curves n° 1 - 2 - 3 = setting ranges


CM.3.M.AB

File: ECM3M003 XI • 17 01/2002/e 11


CM.3.M... MODULAR MAX. PRESSURE STACKABLE VALVES
OFF-HIGHWAY
MACHINERY
OVERALL DIMENSIONS

Fixing screws UNI 5931 M5x85


with material specification min. 8.8
Tightening torque 5 Nm / 0.5 Kgm

MOUNTING

11 File: ECM3M001 XI • 18 01/2002/e


FE02.3... INLET MODULE UNITS
WITH PRESSURE RELIEF VALVE (UP TO 15 l/min) OFF-HIGHWAY
Module units FE10.3... provide pres- MACHINERY
sure relief valve with adjustable pres-
sure setting ranges. Max. operating pressure 250 bar
Manual adjustment is available by a Setting ranges: spring 1 30 bar
grub screw. Maximum flow is 15 l/min. spring 2 90 bar
spring 3 180 bar
The threaded ports (P and T) are spring 4 250 bar
available in two different sizes: G3/8" Max. flow 15 l/min
FE02.3... or 9/16-18UNF. Hydraulic fluids Mineral oils DIN 51524
Fluid viscosity 10 ÷ 500 mm2/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight 0,6 Kg

ORDERING CODE
FE02 Inlet module unit (up to 15 l/min)
with pressure relief valve PRESSURE - FLOW RATE MINIMUM SETTING PRESSURE
3 Size 4
4

* Port sizes: 3

1 = G3/8" 1
2
2 = 9/16-18UNF
P (bar)

P (bar)
2

1
C Adjustment:
Grub screw

* Setting ranges Q (l/min) Q (l/min)


1 = max. 30 bar (white spring)
2 = max. 90 bar (yellow spring)
3 = max. 180 bar (green spring)
4 = max. 250 bar (orange spring)

** 00 = No variant
V1 = Viton

1 Serial No.

OVERALL DIMENSIONS AND HYDRAULIC SYMBOL

File: EFE023001 XI • 19 01/2001/e 11


FE10.3... INLET MODULE UNITS
WITH PRESSURE RELIEF VALVE (UP TO 40 l/min) OFF-HIGHWAY
Module units FE10.3... provide pres- MACHINERY
sure relief valve with adjustable pres-
sure setting ranges.
Max. operating pressure 320 bar
Manual adjustment is available by a Setting ranges: spring 1 max. 50 bar
grub screw or plastic knob. Maximum spring 2 max. 150 bar
flow is 30 l/min. spring 3 max. 320 bar
Max. flow 40 l/min
The threaded ports (P and T) are
Hydraulic fluids Mineral oils DIN 51524
FE10.3... available in two different sizes: G3/8"
Fluid viscosity 10 ÷ 500 mm2/s
or 9/16-18UNF.
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight 0,4 Kg

ORDERING CODE
FE10 Inlet module unit (up to 40 l/min)
with pressure relief valve PRESSURE - FLOW RATE MINIMUM SETTING PRESSURE
3 Size 3
3

* Port sizes:
1 = G3/8"
P (bar)

2 = 9/16-18UNF

P (bar)
2
2

1
* Adjustment: 1
M = Plastic knob
C = Grub screw
Q (l/min) Q (l/min)
* Setting ranges
1 = max. 50 bar (white spring)
2 = max. 150 bar (yellow spring)
3 = max. 320 bar (orange spring)

** 00 = No variant
V1 = Viton

1 Serial No.

OVERALL DIMENSIONS AND HYDRAULIC SYMBOL

M
Type of adjustment

M = Plastic knob
C = Grub screw

11 File: EFE103001 XI • 20 02/2001/e


FE10.P... INLET MODULE UNITS WITH PRESSURE RELIEF
VALVE AND ELECTRICAL VENTING VALVE (UP TO 30 l/min) OFF-HIGHWAY
Module units FE10.3... provide a MACHINERY
pressure relief valve with adjustable
pressure setting ranges and an Max. operating pressure 300 bar
electrical venting valve. Max. flow 30 l/min
The pressure relief valve's manual Hydraulic fluids Mineral oils DIN 51524
adjustment is available by a grub screw Fluid viscosity 10 ÷ 500 mm2/s
or plastic knob. Maximum flow is Fluid temperature -25°C ÷ 75°C
30l/min. Ambient temperature -25°C ÷ 60°C
FE10.P... Max. contamination level class 10 in accordance
The threaded ports (P and T) are with NAS 1638 with filter ß25≥75
available in two different sizes: G3/8" Weight 1,1 Kg
or 9/16-18UNF.
Setting ranges for pressure relief valve:
spring 1 max. 50 bar
spring 2 max. 150 bar
spring 3 max. 320 bar
ORDERING CODE
Features for electrical venting valve:
FE10 Inlet module unit (up to 30 l/min) Max. excitation frequency 2 Hz
Duty cycle 100% ED
with pressure relief valve
Type of protection (connector used depending) IP65

P Electric venting valve


DIAGRAMS FOR PRESSURE RELIEF VALVE
3 Size
PRESSURE - FLOW RATE MINIMUM SETTING PRESS.
* Port sizes: 3
1 = G3/8" 3

2 = 9/16-18UNF

* Adjustment:
P (bar)

P (bar)
M = Plastic knob 2
2
C = Grub screw
1
1
* Setting ranges
1 = max. 50 bar (white spring)
2 = max. 150 bar (yellow spring)
Q (l/min) Q (l/min)
3 = max. 320 bar (green spring)

* Voltage for the electric DIAGRAMS FOR


TAB.1 - DC VOLTAGE
venting valve (Tab. 1) ELECTRICAL VENTING VALVE
115Vac/50Hz
L 12V 120Vac/60Hz
** 00 = No variant M 24V with rectifier PRESSURE DROPS
V1 = Viton N 48V* 115Vac/50Hz
Z 102V* 120Vac/60Hz
1 Serial No. X 205V* with rectifier
W Without DC coils
* Special voltage
∆p (bar)

C
Q (l/min)

LIMITS OF USE
P (bar)

M The tests were carried out with


the solenoids at operating
temperature, with a supply
voltage 10% below nominal
Type of adjustment value and with a 40°C fluid
temperature. The fluid used is
M = Plastic knob a mineral oil with a viscosity of Q (l/min)
C = Grub screw
46 mm2/s at 40°C.

File: EFE10P3001 XI • 21 00/2004/e 11


FE.3... INLET MODULE UNITS
NO PRESSURE RELIEF VALVE OFF-HIGHWAY
Module units FE.3... no pressure MACHINERY
relief valve.
The threaded ports (P and T) are Max. operating pressure 250 bar
available in two different sizes: G3/8“ Max. flow 40 l/min
or 9/16-18UNF. Hydraulic fluids Mineral oils DIN 51524
Fluid viscosity 10 ÷ 500 mm2/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
FE.3... Max. contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight 0,3 Kg

ORDERING CODE
FE Inlet module unit
no pressure relief valve

3 Size

* Port sizes:
1 = G3/8"
2 = 9/16-18UNF

** 00 = No variant
V1 = Viton

1 Serial No.
EFE3 - 02/2001/e

OFF-HIGHWAY
FU.3... OUTLET MODULE UNITS
MACHINERY
The threaded port (T) is available in
two different sizes: G3/8" or 9/16- Max. operating pressure 250 bar
18UNF. Max. flow 40 l/min
Outlet modules without ports and for Hydraulic fluids Mineral oils DIN 51524
parallel style only are availble. Fluid viscosity 10 ÷ 500 mm2/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamination level class 10 in accordance
with NAS 1638 with filter ß25≥75
Weight 0,2 Kg
FU.3.*... FU.3...
OVERALL DIMENSIONS

FU.3.*...VERSION FU.3... VERSION


OREDERING CODE
FU Otulet module unit

3 Size

* Port size:
1 = G3/8"
2 = 9/16-18UNF
For outlet module without
ports is not required
(only for parallel style)

00 No variant

1 Serial No.
IFU3 - 03/2001/e

11 File: EF$3001 XI • 22 05/2001/e