Professional Documents
Culture Documents
2 End Finish
+30 ˚deg. -0 / +5 deg. with root face 0.8 mm - 2.40 mm
3 Tolerance on ID Accepted OD Tolerance (±0.75%D)
4 Tolerance on WT Accepted WT Tolerance (-12.5% / +15%)
5 Ovality Accepted (1.5% D)
6 Straightness 1:600
7 Surface Condition Black Varnish on outer surface & Inner Surface will be bare
All testing to be done in JSAW Lab (Non NABL Lab) SWC is same terminology for HIC, so JSL will perform HIC & Coupon to be testing UT
10 Special Test
manually but co relation of graph is not feasible.
Only Ultrasonic Testing to be perform as per API5L/ISO 10893 for longitudinal and transverse defect. Lamination detection not feasible. EMI
11 NDT or MT on pipe body surface is not acceptable, however bevel face including 2” shall be MT tested with dry method
12 Hydro Test Pressure Gauge calibration have in house facility (Max 3500 PSI Accepted)
13 Color Code Not Applicable as per API 5L Clause No. 11.2.7
Preservation for Shipping and/or Storage
14 Pipe will be internally bare condition (Without varnish)