You are on page 1of 8

COLUMN DESIGN SOFTWARE

RECTANGULAR COLUMNS WITH UNEVEN BARS


Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 600 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 600 mm Tension side = 22 36
Concrete cover = 40 mm Compression side = 22 36
y - direction = 8 28 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 15.177% x
Steel rebar, fy = 414 MPa Tie diameter = 10 mm

Number of Load Cases (maximum = 5) = 2

18000

16000

14000
Pu Mux fMn D/C Ratio Remarks
12000 Case 1 3000 4000 3290.4 1.216 Fail!!!
10000 Case 2 2000 2000 3405.4 0.587 Safe!
Case 3 1 1 4104.6 0.000 Safe!
8000 Case 4 1 1 4104.6 0.000 Safe!
6000 Case 5 1 1 4104.6 0.000 Safe!
4000

2000 Note: Press <Ctrl+P> to print.


0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
COLUMN DESIGN SOFTWARE
RECTANGULAR COLUMNS WITH UNEVEN BARS
Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 600 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 600 mm Tension side = 10 25
Concrete cover = 40 mm Compression side = 8 25
y - direction: 4 25 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 3.545% x
Steel rebar, fy = 414 MPa Tie diameter = 16 mm

Number of Load Cases (maximum = 5) = 2

8000

7000

6000 Pu Mux fMn D/C Ratio Remarks


Case 1 3000 4000 1011.4 2.966 Fail!!!
5000 Case 2 2000 2000 1070.6 1.868 Fail!!!
4000 Case 3 1 1 1142.7 0.001 Safe!
Case 4 1 1 1142.7 0.001 Safe!
3000 Case 5 1 1 1142.7 0.001 Safe!
2000

1000 Note: Press <Ctrl+P> to print.


0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
COLUMN DESIGN SOFTWARE
RECTANGULAR COLUMNS WITH UNEVEN BARS
Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 600 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 600 mm Tension side = 8 32
Concrete cover = 40 mm Compression side = 8 32
y - direction: 5 28 bx
Materials: y
Concrete, fc' = 27.6 MPa Steel ratio rg = 5.285% x
Steel rebar, fy = 414 MPa Tie diameter = 10 mm

Number of Load Cases (maximum = 5) = 4

10000
9000
Pu Mux fMn D/C Ratio Remarks
8000
Case 1 2550 4000 1370.7 2.918 Fail!!!
7000 Case 2 2000 1000 1346.0 0.743 Safe!
6000 Case 3 1 1 1559.9 0.001 Safe!
5000 Case 4 1 1 1559.9 0.001 Safe!
Case 5 1 1 1559.9 0.001 Safe!
4000
3000
2000 Note: Press <Ctrl+P> to print.
1000
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
COLUMN DESIGN SOFTWARE
RECTANGULAR COLUMNS WITH UNEVEN BARS
Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 600 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 1200 mm Tension side = 7 28
Concrete cover = 75 mm Compression side = 5 28
y - direction: 6 28 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 2.053% x
Steel rebar, fy = 390 MPa Tie diameter = 16 mm

Number of Load Cases (maximum = 5) = 2

14000

12000

Pu Mux fMnx D/C Ratio Remarks


10000
Case 1 990.16 1292.6 2792.8 0.463 Safe!
8000 Case 2 522.04 2595.06 2760.6 0.940 Safe!
Case 3 1 1 2701.5 0.000 Safe!
6000 Case 4 1 1 2701.5 0.000 Safe!
Case 5 1 1 2701.5 0.000 Safe!
4000

2000
Note: Press <Ctrl+P> to print.
0
0 500 1000 1500 2000 2500 3000 3500
COLUMN DESIGN SOFTWARE
LAR COLUMNS WITH UNEVEN BARS
eveloped by Ryan Darwin, March 2012

Compression side