You are on page 1of 8

NO.

 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A
INTERPRETATION
NO INSPECTION IDENTIFICATION REMARKS
ACCEPT REJECT

DPI was carried out on ;

LINEAR AND
Top Sleeve RAMFILL "B+RE"
ROUNDED
Heat No: 2006646 x INDICATIONS
Serial No: B4606301 ARE PRESENT
ON SLEEVE
BEVEL. REFER
PICTURES FOR
DETAILS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

INSPECTION PICTURES

GENERAL VIEW BEFORE & AFTER  INSPECTION

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

Location of indication

Linear Indication 1 :

Type: Surface Crack
Length: 27mm
Accept/Reject : Reject

DETAILED VIEW; LINEAR INDICATIONS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

Location of indication

Linear Indication 2 :

Type: Surface Crack
Length: 8mm
Accept/Reject : Reject

DETAILED VIEW; LINEAR INDICATIONS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

Location of indication

Linear Indication 3 :

Type: Surface Crack
Length: 10mm
Accept/Reject : Reject

DETAILED VIEW; LINEAR INDICATIONS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

Location of indication

Linear Indication 4 :

Type: Surface Crack
Length: 3mm
Accept/Reject : Reject

DETAILED VIEW; LINEAR INDICATIONS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

Location of indication

Rounded Indication 1 :

Type: Porosity
Accept/Reject : Accept

DETAILED VIEW; ROUNDED INDICATIONS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :


NO. 47‐1 LORONG SG. CHANDONG 19,
TM BANDAR ARMADA PUTRA,
42920 PULAU INDAH,
SELANGOR DARUL EHSAN
MALAYSIA
TELEPHONE (Office) : +603 ‐ 3101 2810
TELEPHONE (H/P)     : +6019 ‐ 325 5151
Email : enquiry@forqeems.com

DYE PENETRANT TESTING REPORT REPORT NO.: FQ/AXN/PGB/DPI/001

KP130 NPS 38 PGU III SEC 1 PERMANENT REPAIR JOB DESCRIPTION : DPI ON PIPE SLEEVE WELD BEVEL
PROJECT :
USING TYPE B WELDED SLEEVE (TERATAI) PROJECT INSPECTION DATE : 14/10/2022
CLIENT : AXIAENERGY (M) SDN. BHD WELD TYPE : N/A
INSP. CODE : API 1104 WELD PROCESS : N/A
RESTRICTIONS : 100% MATERIAL : ASTM A572 Gr 65
TECHNIQUE : SOLVENT REMOVABLE EXAMINATION SURFACE : CLEAN & SATISFACTORY
CONSUMABLES : MAGNAFLUX (SKC-S, SKL-SP2, SKD-S2) ACID ETCHING : YES NO
DRAWING NO. : N/A

Location of indication

Rounded Indication 2 :

Type: Porosity
Accept/Reject : Accept

DETAILED VIEW; ROUNDED INDICATIONS

INSPECTED BY : AMIRUL ASYRAF ALIAS QC DEP : TPIA/CLIENT :

DATE : 14/10/2022 DATE : DATE :

You might also like