You are on page 1of 13

GK 10.2 – GK 40.

Technical data Multi-turn gearboxes

Valve Gearbox
Max. valve Valve attachment Gearbox Reduction Factor1) Max. input Input shaft2) Weight3)
torque ratio torques
Modu-
Nominal lating Standard Nominal Modulating
torque torque4) EN ISO Option torque torque Standard Option
[Nm] [Nm] 5210 DIN 3210 [Nm] [Nm] [mm] [mm] [kg]
1:1 0.9 135 66 20 –
120 60 F10 G0 GK 10.2 8.5
2:1 1.8 67 33 20 –
2:1 1.8 139 66 20 30
250 120 F14 G1/2 GK 14.2 15
2.8:1 2.5 100 48 20 30
2.8:1 2.5 198 80 30 –
500 200 F14 G1/2 GK 14.6 15
4:1 3.6 139 55 20 30
450 1:15) 0.9 500 444 30 40 31
800 2.8:15) 2.5 320 160 30 –
1,000 4:1 3.6 278 111 30 –
400 F16 G3 GK 16.2
500 4:15) 3.6 140 111 20 – 25
1,000 5.6:1 5.0 198 80 30 –
700 5.6:15) 5.0 140 80 20 –
5.6:1 5.0 397 160 30 30
2,000 800 F25 G4 GK 25.2 60
8:1 7.2 278 111 30 30
4,000 5.6:15) 5.0 800 320 40 –
2,800 5.6:15) 5.0 560 320 30 –
1,600 F30 G5 GK 30.2 110
8:1 7.2 556 222 30 30
4,000
11:1 9.9 404 162 30 30
8:15) 7.2 1,111 – 40 –
8,000 – F35 G6 GK 35.2 11:1 9.9 808 – 40 – 190
16:1 14.4 556 – 40 30
16:1 14.4 1 111 – 40 –
16,000
– F40 G7 GK 40.2 22:1 19.8 808 – 40 – 250
10,000 22:15) 19.8 505 – 30 –

1) – 5) Refer to notes on page 3.


We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y000.330/003/en Issue 2.14 Page 1/5


GK 10.2 – GK 40.2

Technical data Multi-turn gearboxes

Possible combinations with multi-turn actuators


Gearbox Reduction ratio Suitable AUMA Input mounting flange Permissible actuator
multi-turn actuator6) for mounting multi-turn weight
actuator

Max.
EN ISO 5210 DIN 3210 [kg]
SA 10.2/SAR 10.2 F10 G0 40
1:1
SA 14.2/SAR 14.2 F14 G1/2 80
GK 10.2
SA 07.6/SAR 07.6
2:1 F10 G0 40
SA 10.2/SAR 10.2
SA 10.2/SAR 10.2 F10 G0 40
2:1
GK 14.2 SA 14.2/SAR 14.2 F14 G1/2 80
2.8:1 SA 10.2/SAR 10.2 F10 G0 40
2.8:1 SA 14.2/SAR 14.2 F14 G1/2 80
GK 14.6 SA 10.2/SAR 10.2 F10 G0 40
4:1
SA 14.2/SAR 14.2 F14 G1/2 80
1:15) SA 14.6/SAR 14.6 F14 G1/2 80
2.8:15) SA 14.6/SAR 14.6 F14 G1/2 80
SA 14.2/SAR 14.2
4:1 F14 G1/2 80
GK 16.2 SA 14.6/SAR 14.6
5)
4:1 SA 14.2/SAR 14.2 F14 G1/2 80
5.6:1 SA 14.2/SAR 14.2 F14 G1/2 80
5.6:15) SA 14.2/SAR 14.2 F14 G1/2 80
5.6:1 SA 14.6/SAR 14.6 F14 G1/2 80
GK 25.2 SA 14.2/SAR 14.2
8:1 F14 G1/2 80
SA 14.6/SAR 14.6
5.6:15) SA 16.2/SAR 16.2 F16 G3 160
SA 14.6/SAR 14.6 F14 G1/2 80
5.6:15)
SA 16.2/SAR 16.2 F16 G3 160
GK 30.2
SA 14.6/SAR 14.6 F14 G1/2 80
8:1
SA 16.2/SAR 16.2 F16 G3 160
11:1 SA 14.6/SAR 14.6 F14 G1/2 80
SA 16.2/SAR 16.2 F16 G3 160
8:15)
SA 25.1/SAR 25.1 F25 G4 300
GK 35.2 11:1 SA 16.2/SAR 16.2 F16 G3 160
SA 14.6/SAR 14.6 F14 G1/2 80
16:1
SA 16.2/SAR 16.2 F16 G3 160
SA 16.2/SAR 16.2 F16 G3 160
16:1
SA 25.1/SAR 25.1 F25 G4 300
GK 40.2 22:1 SA 16.2/SAR 16.2 F16 G3 160
SA 14.6/SAR 14.6 F14 G1/2 80
22:15)
SA 16.2/SAR 16.2 F16 G3 160

5) – 6) Refer to notes on page 3.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y000.330/003/en Issue 2.14 Page 2/5


GK 10.2 – GK 40.2

Technical data Multi-turn gearboxes

General information
Bevel gearboxes for motor or manual operation of valves (e.g. gate valves and globe valves).

Notes to table on pages 1 + 2


1) Factor Conversion factor from output torque to input torque to determine the actuator size
For new gearboxes, input torques increased by 15 % are required due to lower efficiency.
2) Input shaft Depending on the required input torque
3) Weight Specified weight includes output drive sleeve (without bore) and grease filling in the gear housing
4) Max. valve torque for modulating Modulating torque = permissible, average torque for modulating duty
torque
5) Special reduction ratio On request
6) Multi-turn actuator flange Standard flange according to EN ISO 5210

Features and functions


Type of duty  Short-time duty S2 - 15 min (open-close duty)
 Intermittent duty S4 - 25 % (modulating duty)
Direction of rotation Standard: Clockwise rotation at input shaft results in clockwise rotation at output drive
Options:  GK 10.2 – GK 25.2: Reversal of direction of rotation by reversing gearbox GW 14.1
 GK 30.2 – GK 40.2: Clockwise rotation possible as an alternative
Stages Single stage: GK 10.2 – GK 25.2
Double stage: GK 30.2 – GK 40.2
Input shaft Input shaft made of stainless steel
Standard: Cylindrical with parallel key according to DIN 6885-1 (refer to table on page 1)
Option: Square:  conical (DIN 3233)
 cylindrical
With respect to size, please contact AUMA

Operation
Motor operation  Directly via electric multi-turn actuator
 Input mounting flanges for multi-turn actuator (refer to table page 2)
Manual operation Available handwheel diameters according to EN 12570, selection according to output torque:
Type GK 10.2 GK 14.2 GK 14.6 GK 16.2
Reduction ratio 1:1 2:1 2:1 2.8:1 2.8:1 2.8:1 4:1 1:1 2.8:1 4:1 4:1 5.6:1 5.6:1
Standard hand-
315 200 315 200 315 400 315 800 630 315 500 315 400
wheel Ø [mm]
Special hand-
wheel 400 400 400 800 400 800 400 800
Ø [mm]
Type GK 25.2 GK 30.2 GK 35.2 GK 40.2
Reduction ratio 5.6:1 8:1 5.6:1 5.6:1 8:1 11:1 8:1 11:1 16:1 16:1 22:1 22:1
Standard hand-
630 500 800 800 800
wheel Ø [mm]
Special hand-
wheel 800 800 800 800
Ø [mm]

Standard:  Handwheel made of aluminium


 Handwheel with ball handle
Options:  Handwheel made of GJL-200
 Handwheel lockable
 WSH for signalling position and end positions

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y000.330/003/en Issue 2.14 Page 3/5


GK 10.2 – GK 40.2

Technical data Multi-turn gearboxes

Valve attachment
Valve attachment A, B1, B2, B3, B4 according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special output drive types: AF, AK, AG, IB1, IB3, IB4

Service conditions
Mounting position Any position
Ambient temperature Standard: –40 °C to +80 °C
Options: –60 °C to +60 °C
0 °C to +120 °C
Enclosure protection according to Standard: IP68-8, dust and water tight up to max. 8 m head of water
EN 60529
Option: IP68-20, dust and water tight up to max. 20 m head of water
Corrosion protection Standard: KN Suitable for installation in industrial units, in water or power plants with a low
pollutant concentration
Options: KS Suitable for use in areas with high salinity, almost permanent condensation, and
high pollution.
KX Suitable for use in areas with extremely high salinity, permanent condensation,
and high pollution.
Paint Two-component iron-mica combination
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime AUMA multi-turn gearboxes meet or exceed the lifetime requirements of EN 15714-2. Detailed information
can be provided on request.

Accessories
Reversing gearbox  GW reversing gearbox for reversal of rotation direction for manual and motor operation

Special features for use in potentially explosive atmospheres


Explosion protection in accordance Standard: II2G c IIC T4
with ATEX 94/9/EC II2D c T130 °C
Options: II2G c IIC T3
II2D c T190 °C
IM2 c
Type of duty Open-close Short-time duty S2 - 15 min with the following average output torques:
duty:

Type GK 10.2 GK 14.2 GK 14.6 GK 16.2


Reduction ratio 1:1 2:1 2:1 2.8:1 2.8:1 4:1 4:1 5.6:1
Average output torque
40 60 125 150 250 300 500
in [Nm]
Type GK 25.2 GK 30.2 GK 35.2 GK 40.2
Reduction ratio 5.6:1 8:1 8:1 11:1 11:1 16:1 16:1 22:1
Average output torque
600 1,000 2,000 4,000 8,000
in [Nm]

Modulating Intermittent duty S4 - 25 % with modulating torque


duty:
Ambient temperature Standard: –40 °C to +40 °C (II2G c IIC T4; II2D c T130 °C)
–40 °C to +60 °C (II2G c IIC T4; II2D c T130 °C)
-60 °C to +60 °C (II2G c IIC T4; II2D c T130 °C)
Options: –40 °C to +80 °C (II2G c IIC T3; II2D c T190 °C)
0 °C to +120 °C (II2G c IIC T3; II2D c T190 °C)
–20 °C to +40 °C (IM2 c)

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y000.330/003/en Issue 2.14 Page 4/5


GK 10.2 – GK 40.2

Technical data Multi-turn gearboxes

Further information
EU Directives ATEX Directive: (94/9/EC)
Machinery Directive: (2006/42/EC)
Reference documents Brochure Electric actuators for industrial valve automation
Brochure Electric actuators for the automation of valves in the oil and gas industry
Dimensions GK 10.2 – GK 40.2
Technical data SA 07.2 – SA 16.2 with 3-phase AC motors
Technical data SAR 07.2 – SAR 16.2 with 3-phase AC motors
Technical data WSH 10.2 – WSH 16.2
Technical data GW 14.1

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y000.330/003/en Issue 2.14 Page 5/5


SA 07.2 – SA 16.2
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 3-phase AC motors

Type Output speed rpm Torque range1) No. of starts Valve attachment2) Handwheel Weight3)
S2-15 min S2-30 min Starts Standard Option Max. Ø
Min. Max. Max. Max. EN ISO DIN rising stem Ø Reduct. approx.
50 Hz 60 Hz [Nm] [Nm] [Nm] [1/h] 5210 3210 [mm] [mm] ratio [kg]
4 4.8 11: 1
5.6 6.7 8: 1
8 9.6 11: 1
F07 – 26 19
11 13 8: 1
16 19 11: 1
22 26 30 8: 1
SA 07.2 10 20 60 160
32 38 11: 1
45 54 8: 1
63 75 11: 1
F10 G0 34 20
90 108 8: 1
125 150 5.5: 1
180 216 25 4: 1
4 4.8 11: 1
5.6 6.7 8: 1
8 9.6 11: 1
F07 – 26 20
11 13 8: 1
16 19 11: 1
22 26 60 40 8: 1
SA 07.6 20 60 160
32 38 11: 1
45 54 8: 1
63 75 11: 1
F10 G0 34 21
90 108 8: 1
125 150 5.5: 1
180 216 50 30 4: 1
4 4.8 11: 1
5.6 6.7 8: 1
8 9.6 11: 1
22
11 13 8: 1
16 19 11: 1
22 26 120 90 8: 1
SA 10.2 40 60 F10 G0 40 200
32 38 11: 1
45 54 8: 1
63 75 11: 1
25
90 108 8: 1
125 150 5.5: 1
180 216 100 70 4 :1
4 4.8 11: 1
5.6 6.7 8: 1
44
8 9.6 11: 1
11 13 8: 1
16 19 11: 1
22 26 250 180 8: 1
SA 14.2 100 60 F14 G1/2 57 315
32 38 11: 1
45 54 8: 1
48
63 75 11: 1
90 108 8: 1
125 150 5.5: 1
180 216 200 140 4: 1
4 4.8 11: 1
5.6 6.7 8: 1
46
8 9.6 11: 1
11 13 8: 1
16 19 11: 1
22 26 500 360 8: 1
SA 14.6 200 60 F14 G1/2 57 400
32 38 11: 1
45 54 8: 1
53
63 75 11: 1
90 108 8: 1
125 150 5.5: 1
180 216 400 290 4: 1
4 4.8 11: 1
5.6 6.7 8: 1
8 9.6 11: 1
67
11 13 8: 1
16 19 11: 1
1,000 710
22 26 8: 1
SA 16.2 400 60 F16 G3 75 500
32 38 11: 1
79
45 54 8: 1
63 75 11: 1
90 108 8: 1
83
125 150 5.5: 1
800 570
180 216 4: 1
1) – 3) Refer to notes on page 2.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y004.785/003/en Issue 1.14 Page 1/4


SA 07.2 – SA 16.2
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 3-phase AC motors

General information
AUMA NORM multi-turn actuators require electric controls.
For sizes SA 07.2 – SA 16.2, AUMA offer AM or AC actuator controls. These can also easily be mounted to the actuator at a later date.

Notes on table on page 1


1) Torque range The tripping torque is adjustable for directions OPEN and CLOSE within the indicated torque range.
2) Valve attachment Indicated flange sizes apply for output drive types A and B1.
Refer to dimension sheets for further output drive types.
3) Weight Indicated weight includes AUMA NORM multi-turn actuator with 3-phase AC motor, electrical connection in
standard version, output drive type B1 and handwheel.

Features and functions


Type of duty Standard: Short-time duty S2 - 15 min, classes A and B according to EN 15714-2
Option: Short-time duty S2 - 30 min, classes A and B according to EN 15714-2
For nominal voltage and 40 °C ambient temperature and at average load with 35 % of the max. torque
Motors 3-ph AC asynchronous motor, type IM B9 according to IEC 60034
Mains voltage, mains frequency Standard voltages:
3-phase AC current
Voltages/frequencies
Volt 220 230 240 380 400 415 440 460 480 500
Hz 50 50 50 50 50 50 60 60 60 50

Special voltages:
3-phase AC current
Voltages/frequencies
Volt 525 575 660 690
Hz 50 50 50 50

Permissible variation of mains voltage: ±10 %


Permissible variation of mains frequency: ±5 %
Overvoltage category Category III according to IEC 60364-4-443
Insulation class Standard: F, tropicalized
Option: H, tropicalized
Motor protection Standard: Thermoswitches (NC)
Option: PTC thermistors (according to DIN 44082)
PTC thermistors additionally require a suitable tripping device in the controls.
Self-locking Self-locking: Output speeds up to 90 rpm (50 Hz) or 108 rpm (60 Hz)
NOT self-locking: Output speeds from 125 rpm (50 Hz) or 150 rpm (60 Hz)
Multi-turn actuators are self-locking, if the valve position cannot be changed from standstill while torque acts
upon the output drive.
Motor heater (option) Voltages: 110 – 120 V AC, 220 – 240 V AC or 380 – 400 V AC (externally supplied)
Power depending on the size 12.5 – 25 W
Manual operation Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation
Options: Handwheel lockable
Handwheel stem extension
Power tool for emergency operation with square 30 mm or 50 mm
Indication for manual operation Indication whether manual operation is active/not active via single switch (1 change-over contact)
(option)
Electrical connection Standard: AUMA plug/socket connector with screw-type connection
Options: Terminals or crimp connection
Gold-plated control plug (sockets and plugs)
Threads for cable entries Standard: Metric threads
Options: Pg-threads, NPT-threads, G-threads
Terminal plan TPA00R1AA-101-000 (basic version)

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y004.785/003/en Issue 1.14 Page 2/4


SA 07.2 – SA 16.2
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 3-phase AC motors

Valve attachment Standard: B1 according to EN ISO 5210


Options: A, B2, B3, B4 according to EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special output drive types: AF, B3D, ED, DD, IB1, IB3
A prepared for permanent lubrication of stem

Electromechanical control unit


Limit switching Counter gear mechanism for end positions OPEN and CLOSED
Turns per stroke: 2 to 500 (standard) or 2 to 5,000 (option)
Standard: Single switches (1 NC and 1 NO) for each end position, not galvanically isolated
Options: Tandem switches (2 NC and 2 NO) for each end position, switches galvanically isolated
Triple switches (3 NC and 3 NO) for each end position, switches galvanically isolated
Intermediate position switch (DUO limit switching), adjustable for any position
Torque switching Torque switching adjustable for directions OPEN and CLOSE
Standard: Single switches (1 NC and 1 NO) for each direction, not galvanically isolated
Options: Tandem switches (2 NC and 2 NO) for each direction, switches galvanically isolated
Position feedback signal, analogue Potentiometer or 0/4 – 20 mA (electronic position transmitter)
(options)
Mechanical position indicator Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
(option)
Running indication Blinker transmitter
Heater in switch compartment Standard: Self-regulating PTC heater, 5 – 20 W, 110 – 250 V AC/DC
Options: 24 – 48 V AC/DC or 380 – 400 V AC
A resistance type heater of 5 W, 24 V AC is installed in the actuator in combination with AM or AC actuator
controls.

Electronic control unit (only in combination with AC actuator controls)


Non-intrusive setting (option) Magnetic limit and torque transmitter MWG
for 1 to 500 turns per stroke or
10 to 5,000 turns per stroke
Position feedback signal Via actuator controls
Torque feedback signal Via actuator controls
Mechanical position indicator Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
(option)
Running indication Blinking signal via controls
Heater in switch compartment Resistance type heater with 5 W, 24 V AC

Service conditions
Use Indoor and outdoor use permissible
Mounting position Any position
Installation altitude ≤ 2 000 m above sea level
> 2,000 m above sea level, on request
Ambient temperature Standard: –40 °C to +80 °C
Options: –60 °C to +60 °C
0 °C to +120 °C
Humidity Up to 100 % relative humidity across the entire permissible temperature range
Enclosure protection according to Standard: IP68 with AUMA 3-phase AC motor
EN 60529 For special motors differing enclosure protection: refer to name plate
Option: DS Terminal compartment additionally sealed against interior (double sealed)
According to AUMA definition, enclosure protection IP68 meets the following requirements:
 Depth of water: maximum 8 m head of water
 Duration of continuous immersion in water: Max. 96 hours
 Up to 10 operations during continuous immersion

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y004.785/003/en Issue 1.14 Page 3/4


SA 07.2 – SA 16.2
AUMA NORM
Technical data Multi-turn actuators for open-close duty with 3-phase AC motors

Pollution degree Pollution degree 4 (when closed)


according to EN 60664-1
Vibration resistance according to 2 g, from 10 Hz to 200 Hz
IEC 60068-2-6 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. Valid for multi-turn actuators in version AUMA NORM (with AUMA plug/socket connector,
without actuator controls). Not valid in combination with gearboxes.
Corrosion protection Standard: KS Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Options: KX Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
KX-G Same as KX, however aluminium-free version (outer parts)
Finish coating Powder paint
Two-component iron-mica combination
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime AUMA multi-turn actuators meet or even exceed the lifetime requirements of EN 15714-2. Detailed informa-
tion can be provided on request.

Further information
EU Directives Electromagnetic Compatibility (EMC): (2004/108/EC)
Low Voltage Directive: (2006/95/EC)
Machinery Directive: (2006/42/EC)
Reference documents Brochure Electric actuators for industrial valve automation
Dimensions SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2
Electrical data SA 07.2 – SA 16.2 with 3-phase AC motors
Technical data for switches
Technical data Electronic position transmitter/potentiometer
Technical data Output speeds, motors, reduction ratios and blinker transmitters

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Y004.785/003/en Issue 1.14 Page 4/4

You might also like