You are on page 1of 1

Rev. No.

: 1
Ocean Jade Shipping Date : 1st Jan 14
HSE CHECK LISTS Pre. by : SOT
App. by : DPA

HSE CL 03 SCBA ENTRY LOG Page1 of 1

Vessel Position Date:


: :
Pressur
Set No.: Wearer Name Time in Time Due out Time Out Remarks
e

*Important note:
A 6 liter cylinder fully charged to 200 Bars contains 1200 liters and will last approximately 20 minutes. This will be significantly
reduced in an emergency situation when the wearer is under stress and making a lot of effort. Larger or unfit persons will also
consume more air. The following table gives a guide to the working duration that can be expected under normal conditions and can
be used to assist in calculating the DUE OUT time:

Pressur Duration Pressure Duration


e The table on left is based on a standard 6L at 200 Bars.
200 Bar 20 min
180 Bar 17 min The calculation is based on average air consumption of 40 Liters per minute.
160 Bar 14 min
The working duration allows a safety reserve of 10 minutes.
140 Bar 11 min
120 Bar 8 min
For larger cylinder (e.g. 9L) you should calculate the expected duration
100 Bar 5 min
67 Bar 0 min times and to enter them in the blanks provided.
<67 Bar GET OUT

* The checklist will be used whenever SCBA is used for any purposes onboard the ship.