You are on page 1of 10

ENGINEER’S STAMP: CONTRACTOR’S STAMP:

C Issued for Tender Gasic Nyoundou Wilken 06.11.2020


B Issued for Tender Shahab Nyoundou Wilken
0 Issued for Tender Shahab Nyoundou Wilken 19.11.2019
REV DESCRIPTION PREPARED CHECKED APPROVED DATE

KINGDOM OF SAUDI ARABIA ‫اﻟـﻤﻤـﻠـﻜــﺔ اﻟﻌــﺮﺑـﯿــﺔ اﻟﺴــﻌـﻮدﯾـــﺔ‬


‫اﻟﻤـﺆﺳــﺴــــﺔ اﻟﻌــﺎﻣــﺔ ﻟﺘﺤــﻠـﯿﺔ اﻟـﻤــﯿــﺎه اﻟـﻤــﺎﻟــﺤــﺔ‬
SALINE WATER CONVERSION CORPORATION
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

FICHTNER GMBH & CO. KG

TENDER DOCUMENTS

LOCATION: TITLE:
Western Coast VOLUME IX PART PG-B218
PACKAGE: TECHNICAL SPECIFICATION
DATA NETWORK
SCALE: REV:
None Q A 1 0 - H - 0 4 1 8 C
SUBCONTRACTOR:
Sheet 1 of 10
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 2 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

Disclaimer
The content of this document is intended for the exclusive use of Fichtner’s client and
other contractually agreed recipients. It may only be made available in whole or in part to
third parties with the client’s consent and on a non-reliance basis. Fichtner is not liable to
third parties for the completeness and accuracy of the information provided therein.

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 3 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

Table of Contents

1. Introduction 4
1.1 Terms and Conditions 4

2. Wired Network Design 5


2.1 Discerption 5
2.2 Hierarchical Network Design 5
2.3 Equipment and Material 6

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 4 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

1. Introduction
This document provides an overview to Saline Water Conversion
Corporation (SWWC) network technical specification and standard, it
should be a reference to all contractor working on SWCC data
infrastructure.

1.1 Terms and Conditions

· The data network should be fully isolated than another core business
network like DCS.
· The network should be easy to modify to adapt to network growth and
general business changes.
· The network should reliably deliver applications and provide reasonable
response times from any host to any host.
· The network should be secure. It should protect the data that is
transmitted over it and data stored on the devices that connect to it.
· Requirements of the cyber security concept as outlined in part B10 I&C
works shall be considered.
· All materials should be new, unused, branded, not End-of-Life (EoL),
and not End-of-Sale (EoS).
· The documents, layout, diagram and test is part of contracted.
· Provide Scalable Network designs.
· Manageability Network design must be able to manage and support the
network.
· All specifications, settings, adjustable at the discretion of the Department
of IT. The site surveys are required for all SWCC.

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 5 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

2. Wired Network Design

2.1 Discerption
Network design should follow hierarchical topology to enable designing
network in layers. The benefits are Cost savings, Ease of understanding,
Easy network growth and Improved fault isolation.

2.2 Hierarchical Network Design


The hierarchical design model has three basic layers:
· Core layer: Connects distribution layer devices.
· Distribution layer: Interconnects the smaller local networks.
· Access layer: Provides connectivity for network hosts and end devices.

Core Layer
The Core-layer (network backbone) provides high-speed, scalable, reliable,
fault tolerance and low-latency connectivity, this layer is only available in
one place (Main building). To serve several distribution switches that
connect different buildings.

The core layer should have the following characteristics:


· Offer high reliability,
· Provide redundancy and load balancing,
· High-speed and aggregate links,
· Provide fault tolerance,
· Flexibility,
· Full mesh topology,
· Modular chassis-based design,
· Devices at the core layer should contain redundant power supplies and
hot swappable components,
· Layer 3 devices, including multilayer switches,
· Facilitate network growth,
· The network design must permit the occasional, but necessary, hardware
and software upgrade/change to be made without disrupting any network
applications,
· The core should also have the minimal control plane configuration
combined with highly available devices configured with the correct
amount of physical redundancy to provide for this non-stop service
capability,
· Intelligent network services such as QoS, Security, load balancing,
Network virtualization, etc.,
· Routers or multilayer switches that combine routing and switching in the
same device, and

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 6 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

· Routing protocols that scale well and converge quickly.

Distribution Layer
The distribution layer is the isolation point between the network’s access
layers and core layers. The distribution layer is associated with routing,
filtering, and is the communication point between the core layer and the
access layer.

Some of key characteristics of distribution-layer are as following:


· Provide redundancy and load balancing,
· Isolating the core from access layer failures or disruptions,
· Filtering and managing traffic flows,
· Routing between access layer VLANs,
· Layer 3 devices, including multilayer switches,
· Enforcing access control policies,
· Summarizing routes before advertising the routes to the core,
· QoS mechanisms, such as priority-based queuing,
· Demarcation between static and dynamic routing protocols,
· Departmental or workgroup access, and
· Broadcast or multicast domain definition.

Access Layer
The access layer is used to control user access to the internetwork resources
such as PCs, printers, Wireless client, and IP phones. Access layer services
and devices reside inside each building of a campus, each remote site and
server farm, and at the enterprise edge.

Some of key characteristics of access-layer are as following:


· Using VLANs and IP subnets for segregating user groups and traffic,
· Ensuring that the network does not become too complex,
· Easy troubleshooting when a problem occurs,
· Layer 2 support,
· Providing Quality of Service (QoS), and
· Providing Port Security.

2.3 Equipment and Material

· Switches: with high availability services

· Core Layer Switch must support the following:


· High-speed backbone handles very high forwarding rates,
· Support link aggregation (10GbE connections which is currently the
fastest available Ethernet connectivity,
· Support additional hardware redundancy features,
· Intelligent network services such as QoS, Security and load balancing,

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 7 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

· Supported SNMP1, SNMP2 and SNMPv3,


· Rich layer 2 to layer 4 QoS to support a large number of applications,
· Two modular chassis,
· Two supervisor for each chassis,
· Bandwidth capacity not less than 800 Gbps per chassis,
· Support Virtual Switching System,
· Support 1,10 Gigabit Ethernet fiber line cards module,
· Port Aggregation Protocol (PagP),
· IEEE 802.2.3ad (Link Aggregation Control Protocol),
· Supports standard Small Form-Factor Pluggable Plus (SFP+) optics,
· SFP+ and SFP can be used simultaneously on the same line card
without any restrictions,
· Support standard IEEE 802.1AE encryption,
· Support for IPv4 and IPv6 routing, multicast routing, modular quality
of service (QoS), Flexible Net Flow (FNF), and enhanced security
features,
· Redundant power supplies,
· High reliability and availability,
· Low latency and good manageability, and
· Support important routing protocol RIP, OSPF and EIGRP.

· Distribution Layer Switch must support the following:


· One supervisor for each chassis,
· Bandwidth capacity not less than 800 Gbps,
· Routing between virtual LANs (VLAN),
· Media translations (for example, between Ethernet and Token Ring),
· Routing services between LANs and VLANs and between routing
domains (e.g., EIGRP to OSPF),
· Security filtering,
· Support 1,10 Gigabit Ethernet interfaces,
· Support Virtual Switching System,
· Port Aggregation Protocol (PagP),
· IEEE 802.2.3ad (Link Aggregation Control Protocol),
· Supports standard Small Form-Factor Pluggable Plus (SFP+) optics,
· SFP+ and SFP can be used simultaneously on the same line card
without any restrictions,
· Support standard IEEE 802.1AE encryption,
· Support for IPv4 and IPv6 routing, multicast routing, modular quality
of service (QoS), Flexible Net Flow (FNF), and enhanced security
features,
· Redundant power supplies,
· Control Broadcast and Multicast: The layer serves as the boundary for
broadcast and multicast domains,
· Layer 2,3 switching,
· Policy-based connectivity,

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 8 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

· Static routing, dynamic routing,


· Provides the inter-VLAN routing functions,
· Supported SNMP1, SNMP2 and SNMPv3, and
· Provides advanced security policies that can be applied to network
traffic using Access Control Lists (ACL).

· Access Layer Switch must support the following:


· Port Security,
· VLAN,
· Fast Ethernet/Gigabit Ethernet,
· Supported SNMP1, SNMP2 and SNMPv3,
· Power over Ethernet (PoE) Link Aggregation,
· Supply Switch with 24 Port,
· Stackable Switch,
· Bandwidth capacity not less than 92 Gbps,
· High availability,
· Layer 2 switching,
· EtherChanne Group,
· Dynamic Trunking Protocol,
· Port Aggregation Protocol (PagP),
· IEEE 802.1Q VLAN encapsulation ACLs,
· Link Aggregation Control Protocol (LACP),
· Support for IPv4 and IPv6 routing, multicast routing, modular quality
of service (QoS), Flexible Net Flow (FNF), and enhanced security
features,
· Port security,
· Broadcast suppression,
· QoS classification and marking and trust boundaries,
· Rate limiting/policing,
· Address Resolution Protocol (ARP) inspection,
· Virtual access control lists (VACL),
· Spanning tree protocol (STP),
· Trust Classification, and
· Power over Ethernet (PoE) and auxiliary VLANs for VoIP.

· UPS
· Pack mounted,
· Management port,
· kVA size depends of number switch +30%,
· Minimum kVA 3000, and
· Cable.

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 9 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

· UTP:
· Should be based on a four pair Unshielded Twisted Pair (UTP) that
meets or exceed the transmission performance requirements for
Category 6 (Cat 6) and Cat6a inside Datacenter room that holds
Backbone switch.
· Support 1G at minimum speed
· Color code:
· Pair 1: Blue & White/Blue
· Pair 2: Orange & White/Orange
· Pair 3: Green & White/Green
· Pair 4: Brown & White/Brown

· Fiber:
· Fiber Core indoor/outdoor optic cable, RODENT PROJECTED
STEEL ARMOURED, LSF/OH sheath Singe Mode OS2
· Speed support at least 1/10 Gbps
· 24 core fiber between Core layer and Distribution layer
· 12 core fiber between Distribution layer and access layer

· Network Cabinet
· Access cabinet
· Wall-mount rack (9u – 21u) or Rack Mount
· 600mm X 800mm
· Core & Distribution cabinets
· Rack Mount
· 42U 800mm X 1000mm
· General specifications
· Have removable front and rear doors to encourage airflow from
front to back
· Removable side panels
· Have front Door, Split Rear Door
· Cable Management
· Side to side airflow for network switch equipment
· Removable doors, rack-mount units are marked and numbered

· Patch Panel
· UTP:
· 1U (24 port) or 2U (48 port)
· Shall meet or exceed the requirements for Category 6
· The panels shall feature both T568A and T568B wiring
configurations
· Model connector
· Flexible installation- Install from either front or rear of
faceplate
· Quick identification- Colored Icons provided for port
identification

4871A95/S133Doc-801060045-7070
CONSTRUCTION OF SALES GAS SUPPLY PIPELINE TO YANBU
PLANT PHASE-3 PROJECT

Subject: VOLUME IX PART PG-B218 Page 10 of 10


TECHNICAL SPECIFICATION
DATA NETWORK
Doc No.: Q A 1 0 - H - 0 4 1 8 Rev. C

· Easy Termination- Punch down with standard 110 termination


tools
· Universal Wiring- T568A and T568B wiring compatible
· Combines modular design with high density
· Have rear cable management bars
· Color-coded front labelling for easy port identification
· Capable of multiple re-terminations
· Panel available with patented magnifying lens label holder for easy
reading
· Icon label holders and designations labels included
· The panel can be configured for a variety of multimedia applications
and 10GBASE-T performance
· Panels can be mounted directly to fit a standard 19-inch relay rack or
cabinet

· FIBER:
· 1U or 2U Rack Mount Fiber Tray with 3 holes
· 24 ports LC Fiber Adapter Panels for each holes (connector)
· Support single mode fiber type os2
· Meet or exceed TIA/EIA-568-C.3 requirements
· Support speed 1,10,40 G
· Provides versatility and flexibility with a fully modular solution
· Mount to standard EIA 19” rack rails
· Horizontal and vertical MPO adapters

· Patch cards
· UTP
· Modular cards feature high performance category 6 cable for
optimal flexibility and transmission performance, exceeding
category 6 performance specifications
· Optional color clips can easily be snapped on for additional color
coding
· Integral latch guard protects plug from snagging when pulling
through pathways or cable managers
· 1Meeter, 3Meeter, with different colors

4871A95/S133Doc-801060045-7070