You are on page 1of 1

NOTES

STAIRS DETAILLING
GENERAL NOTES
This drawing is protected under the
DETAIL 01 - OPEN TREAD copyright Act and cannot be reproduced
in part or in whole whole without authors
consent.
STAIR
1
GLASS PANEL RAILING
All dimensions are to be checked on site,
150MM REINFORCED CONCRETE SLAB
2
written dimensions rules over scaled
dimensions. Any discrepancy in the
dimensions is to be reported to the
3

Architect before work commences.


CONCRETE TREADS WITH 25MM NON-SLIP CARBORANDUM EVAPORATOR UNIT INSTALLED TO
100MM POLYURETHENE INSULATING FORM SUPPORTED BY STEEL RODS 450MM C/C
4

5 MANUFACTURERS SPECIFICATIONS All dimensions are in MM unless


specified.

IN SITU R.C LANDING 5MM THICK FLAT ALUMINIUM SHEETS All construction Work is to comply with
the latest K.B.S standard codes of
THERMOSTAT SCENSOR practice, local authority by-laws and fire
150mm thick masonry wall bedded in cement sand motor regulations.

10

12

13

14

15

16

17

18

19

20

21

22

23
11
6

9
this darwing is to be read in conjuction
RECESSED LIGHT FIXTURES TO with specifications and all other relevant
75MM THICK POLYURETHENE INSULATION ON MASONRY WALL ARCHS APPROVAL drawings.

P.V denotes permanent ventilation and


5MM THICK FLAT ALUMINIUM SHEETS must be provided above all windows and
doors where indicated or shown.

25MM THICK NON-POLISHED TERAZZO FLOOR FINISH Water meter to be 300mm above ground
VAPOUR BARRIER level.

50MM THICK INSULATION ON FLOOR All walls under 200mm thick to reinforced
with hoop iron after every alternating
GLASS PANEL RAILING
COLD ROOM DETAIL 1:20 course.

Damper proof course to be provided


REINFORCED CONCRETE SUBFLOOR under all external walls at grade. D.P.C
to be a minimum of 150mm obove
ground level.

Depth of foundation is to be determined


on site to S.E approval.

All vegetable soil to be removed from


under slab and all paved surfaces.

50MM CANTILEVER CONCRETE All soils under slab and around external
TREADS WITH 25MM OVERLAP EXTRUDED ALLUMINIUM ALLOY BOX MULLION
foundation to be treated for termite
control.
ON TREAD BELOW EXTRUDED PLASTIC
Provide 1 row of 600*600*50mm precast
COVER PLATES AND EXTRUDED ALLUMINUIM ALLOY FOR BOX conc. paving slabs around the building
SCREWS TRANSOM
unless otherwise shown.

All reinforcement work to Structural


120*200MM R.C SPINE BEAM Engineers details.
BEAM HOUSED IN POCKET CAST TRANSOM LOCATED ON SPIGOT TO FIXED TO Drain pipes passing under tarmac,
IN LANDING AND FLOOR BOX MULLION - CONNECTION TO BE MASTIC driveways and buildings to be encased in
150mm thick concrete surround.
SEALED
All sanitary works to the satisfaction of
MULLION BOLTED TO ANGLE BRACKETS THROUGH the mechanical engineer.

UNDERSILL PANEL SLOTTED HOLES-ANGLE BRACKETS SECURED TO FLOOR All roads, storm water drainage and foul
EDGE THROUGH BOLTS LOCATED IN DOVETAIL ANCHOR sewerage to civil engineers drawings.

TO PROVIDE FOR THERMAL MOVEMENT All electrical works to the entire


satisfaction of the Electrical engineer.

DETAIL 05 - CURTAIN WAll 1:50


DETAIL 02 - FIRE ESCAPE 1:50
REVISIONS
STAIR 5MM THICK PORCELAIN TILES GLUED TO
CEMENT SAND SCREED DATE DESCRIPTION

MOULDED AND POLISHED HARDWOOD


TIMBER HANDRAIL

25MM THICK CEMENT SAND FLOOR SCREED

30*30MM STEEL INNER POSTS 150MM R.C LANDING

400*250MM R.C BEAM 150MM THICK R.C SLAB


15*15MM STEEL BALUSTERS
150MM RISER 150MM R.C WAIST WITH SOFFIT
DETAIL 06 1:10
POLISHED CONCRETE FINISH PLASTERED AND PAINTED TO ARCH
APPROVAL

12.5MM THICK PARQUET FLOOR


300MM WIDE CONCRETE TREAD WITH
NON-SLIP CABORANDUM STRIPS 0N 30MM E.X 50*50MM HARDWOOD TIMBER
NOSING BATTERNS
POLISHED CONCRETE FINISH ON TREAD
CLIENT NAME
25MM THICK CEMENT SAND SCREED
MOWASCO

DETAIL 03 150MM THICK R.C SLAB


PROJECT DESCRIPTION

MIXED URBAN
DEVELOPMENT

FLOOR FINISH DETAIL


MOULDED AND POLISHED (MOWASCO)
METAL TOP RAIL HARDWOOD HANDRAIL NUT AND
SCREWED FROM WASHER
8MM DIA UNDERSIDE OF METAL METAL BALUSTER
STEEL SCREW RAIL BOLTED THROUGH
TREAD OF STAIR
PRECAST
M14 EXPANDING STEEL STEEL CONCRETE
BOLTS WITH NUTS STANDARDS TREAD existing slab soffit
AND WASHERS CAST soffit clamp
INTO CONCRETE SPINE alluminium ceiling suspenders at 600mm c/c
BEAM
DOUBLE CANTILEVER anodized alluminium angle plates at SCALE:
TREAD BOLTED TO 600mm c/c AS SHOWN
PRECAST CONCRETE
R.C 120*200MM SPINE BEAM SPINE BEAM

TREAD AND RAILING DETAILS


1:50 CEILING DETAIL 1:20

N
GSPublisherVersion 0.1.100.100
MAINA LEWIS WAMAE // BARC /O42J/2017 // TECHNICAL UNIVERSITY OF MOMBASA