Professional Documents
Culture Documents
P.V
Kit'Yard
P.V
I.C I.C I.C
FRONT ELEVATION 01 Scale 1:100 8 Provide 1 row of 600x600x50mm precast conc
paving slabs around the building unless
otherwise shown.
gt P.V P.V P.V
200
200
P.V S/Steel Sink 01 Depth of foundation to be determined on
site to be not less than 1200mm.
empty window
3,600
3,600
Dining
4,292
Room Cook Charcoal grey coloured , American style roofing sheets in charcoal ground floor slab.
I.C W.c 03 Scale 1:100 on 150x50mm timber rafters @ 600mm c/c on timber purlins ans
W.h.b Plinth level to be minimum 300mm from
struts on timber trusses @ 1800c/c on 150x 50mm tie beam 11 proposed parking level or existing ground level.
P.V on 100x50mm wall plate
200
200
FrF 12
4,500
on 300mm R.C beam to Structural Eng detail . compacted and well consolidated filling.
P.V empty door
P.V Roof details
Shower Kit
1,300
1,300
1,300
W.h.b 200 Roof pitch 300
600
150 P.V I.C Depth of foundation trenches to be minimum
200 1,300 1,300 650 200 4,250 200 900 200 2,201 W2.c00 13 600mm below reduced ground level.
02
PASSAGE Charcoal grey coloured , American style roofing sheets in charcoal
10,600
10,600
03
W.h.b
P.V P.V P.V P.V P.V All pipes and services to be minimum 450mm
P.V empty door on 150x50mm timber rafters @ 600mm c/c on timber purlins ans 200mm thick external wall plastered and 14 below reduced ground level.
200
200
200
struts on timber trusses @ 1800c/c on 150x 50mm tie beam cream white painted to approval
on 100x50mm wall plate 15 All inspection chambers within building area,
(Wall masters Recomended) under building, drive-way,parking to be heavy
I.C P.V P.V on 300mm R.C beam to Structural Eng detail .
duty double seal air-tight covers,drains pipes
2,000
02
5,709
200mm thick external wall plastered and 450mm high external base walling in All parking in the Basements is mechanical
Bed room 16
4,900
4,901
cream white painted to approval natural texture and dark coloured surface to Parking
34M
200
P.V
P.V
I.C Scale 1:100
SIDE ELEVATION 03
200
200
P.V
1,500 200
I.C P.V
P.V Entrance
Verandah
Scale 1:100
200
0.150
COVER AND FRAME
150mm THICK ROOF
SLAB CONC. CLASS FGL FGL
20/20 REINFORCED
WITH Y10@100 c/c Ø150 INLET PIPE 150mm THICK MASONRY WALL
0.600
FROM SEPTIC TANK
BOTH WAYS
100mm diameter UPVC rain water gutters
200
1,500 450
0.100
0.200 0.800 0.200 0.600 2.800 0.600 0.200 0.800 0.200
instalations and connected to water
Septic Tank
(3-6m)
To Details
FGL FGL
3,000
harvesting tanks
2,850
2,400
800
150Ø PC PIPE
Entrance 450mm high external base walling in 200x200
900
0.350
OUTLET
Porch natural texture and dark coloured surface to TWL @ 600mm c/c
Dpc 200mm THICK BASE SLAB
0.450
0.200
WITH MESH A142 IN CENTRE
SECTION THROUGH SOAK PIT
SCALE 1:25
1.200
10mm WATER
1.500
Skirting Details
1.380
10mm WATER PROOFED
PARKING PROOFED RENDERING RENDERING
200mm THICK MASONRY WALL
0.200
0.200
Ø150 INLET PIPE
in all areas 0.300 FROM SEPTIC TANK
0.200
0.100
0.300 0.750
R.C Slab Details 50mm THICK BLINDING
NO. DATE REVISION/ISSUE
150mm thick concrete floor reinforced with B.R.C. CONC. CLASS 15/40 12mm BARS AT 150 c/c
BOTH WAYS
0.200
foundation to S.Eng's details.
0.200
NB: Depth of foundation to be 0.800 100mm THICK
SCUM BAFFLE
2.000
0.300
800
determined on site.
0.600
1.800
A 100Ø uPVC PIPE
OUTLET
0.800
CLIENT'S SIGNATURE
TWL
0.200
100mm THICK SCUM
BAFFLE REINFORCED WITH
ENTRANCE
1.200
MESH A142 IN CENTRE
10mm WATER
0.200
200mm THICK MASONRY WALL
Roof details
0.200 0.8000.200 4.000 0.200.08 00 0.200 SOUTH
Roof pitch 300
0.200
0.200
B 0.300 0.300
200mm THICK BASE SLAB COAST P.O.BOX 26783-00100,
Charcoal grey coloured , American style roofing sheets in charcoal
ROAD on 150x50mm timber rafters @ 600mm c/c on timber purlins ans
struts on timber trusses @ 1800c/c on 150x 50mm tie beam
PLAN
SCALE 1:25
SECTION B-B
SCALE 1:25
CONC. CLASS 20/20 REINFORCED
WITH MESH A142 IN CENTRE Architects NAIROBI
SEPTIC TANK (9m³) DETAILS TEL: +254741717947
on 100x50mm wall plate
on 300mm R.C beam to Structural Eng detail .
Roof Level SEPTIC TANK PARAMETERS EMAIL: l e e j 0 1 7 5 8 @gmail.com
CAPACITY No. OF DESLUDGING DIMENSIONS IN MILLIMETRES
450
IN LITRES PERSONS INTERVAL(YRS) A B C D E F1 F2
P.V
100mm diameter UPVC rain water gutters P.V P.V P.V P.V P.V
3000 10 2 800 1000 1000 3000 800 1500 1400 JOB TITLE
450
3,000
instalations and connected to water 6000 20 2 800 1400 1200 3600 1400 1500 1400
2,850
harvesting tanks FOR MRS ANNE GATHONI GITHENYA
2,400
SITE PLAN 9000 30 2 800 1400 1200 3600 1800 1500 1300
1,350
CHECKED