You are on page 1of 1

DAILY ANALYSIS REPORT

CONDENSATE PRODUCT

Report No : ABC-PEPCLAB-JTB-COND/XII/2022 Sampled On : December 22, 2022


Sample Id : Condensate Bottle 1 Received On : December 22, 2022 15.00
Sample From : CPP Gundih Request By : Pertamina Asset 4 Field Cepu
Sampling Point :- Truck No :-

Parameter Unit Method Name Result Spec. Limit @ JTB


Reid Vapor Pressure (RVP) at
psia ASTM D6377 3.71 < 10.5
37.8oC (V/L Ratio 4:1)

True Vapor Pressure (TVP) at


psia ASTM D6377 4.55 < 10.5
37.8oC (V/L Ratio 4:1)

Hydrogen Sulfide (H2S) wt-ppm UOP 163 248.48 < 10

API Gravity at 60oF degAPI ASTM D1298 NA

Comment : _____________________________________________________________________________
______________________________________________________________________________

Approved by : Zainal Amidi Acknowledge by : Bayu Prawira Riyadi

Badge ID : JTB‐21‐03‐13064 Badge ID : 19030123

Laboratory QA/ QC PT Pertamina EP Cepu Region 4 Zona 12