You are on page 1of 3

VIRLAB, S.A.

Division of URBAR INGENIEROS, S.A.


Vibration Test Laboratory

VIBRATION
Qualification Certificate

Nº 54/LE131

Delivered on: Friday, 06 March 2020

References:
 VIRLAB test procedure number 200107E1, issue 0, dated 08/01/2020: Test
procedure for seismic qualification of “ELECTRICAL EQUIPMENT” according
to IEC60068-3-3 (zone 4), IEC 60068-2-57 and IEC60980 International
Standards”
 International Standard IEC60068-3-3/1991: Environmental testing – Part 3:
Guidance. Seismic tests methods for equipments. Last edition of this standard,
edition 2.0, dated august 2019, which does not include relevant changes
relating to “General Seismic Class tests”, has also been considered in the
elaboration of this test procedure.
 International Standard IEC60068-2-57/2013: “Environmental testing - Part 2-57:
Test Ff: Vibration - Time-history method”.
 International Standard IEC60980/1989: "Recommended Practice for Seismic
Qualification of Class 1E Equipment for Nuclear Power Generating Stations".
 International Standard IEC60068-2-6/2007: Environmental testing – Part 2-6:
Tests – Fc: Vibration (sinusoidal).
 International Standard IEC60068-2-47/2005: “Environmental testing - Part 2-47:
Tests. Mounting of specimens for vibration, impact and similar dynamic tests”.

Laboratory Name: VIRLAB, S.A. (accredited by ENAC, Spanish National Accreditation Entity).
ENAC certificate number 54/LE131.

Laboratory Address: Polígono Industrial de Asteasu, Zona B - 44


Apartado 247 20159 ASTEAU (SPAIN)

Client: EAE ELEKTROTEKNIK SANAYI VE TICARET A.S.

Equipment tested: One (1) Cabinet Prototype manufactured by EAE ELEKTROTEKNIK


SANAYI VE TICARET A.S., described here below:

 E Kabin S series floor standing type electrical panel according to drawing


numbers 05 and 06 “E-Kabin S Series, dated 17/01/2020.

Certificate number “203009C1” Page 1 / 3


NOTE: According to Section 7.8.2.1 of Standard ISO-IEC 17025:2017, it is stated that the results of the present certificate apply only and exclusively to the
samples subjected to test.
VIRLAB, S.A.
Division of URBAR INGENIEROS, S.A.
Vibration Test Laboratory

Pictures included here below show the Cabinet on the test platform, in front-to-back, “X”, and side-to-
side, “Y”, directions, in both cases, simultaneously with the vertical, “Z”, direction.

“XZ Direction” “YZ Direction”

VIRLAB, S.A. certifies that the Cabinet described here above has been tested in its laboratory of
ASTEASU (Spain) on January 8th 2020, as described in VIRLAB test procedure number 200107E1,
issue 0, dated 08/01/2020, elaborated according to International Standard IEC60068-3-3, Zone 4 (AG5),
and IEC60068-2-57, also following IEC60980.

The level applied, according to IEC60068-2-57 (ZPA=0.5 g), AG5 (also Zone 4, according to last edition of
IEC60068-3-3, dated august 2019), considers a Zero Period Acceleration of 0.5 g in horizontal direction,
reaching maximum spectral accelerations of 1.5 g for 5% damping (Figure A.1 of IEC60068-2-57 & Figure 1 of
IEC60068-3-3, issue 2.0) and 0.25 g in vertical direction (50% of the horizontal component, “direction factor of 0.5”).

The Cabinet has been submitted to the tests described here below:

 Resonance search tests, between 1 and 35 Hz, with an acceleration level of 0.1 g, at a rate of 1
octave per minute, independently performed in each one of the three main directions of the
Cabinets, front-to-back, “X”, side-to-side, “Y”, and vertical, “Z”.

 Qualification seismic tests, consisting of five (5) S1 (50% S2) level tests and one (1) S2 level
test corresponding to AG5 level, 30 seconds duration, applied in both “XZ” (front-to-back and
vertical) and “YZ” (side-to-side and vertical) directions.

Certificate number “203009C1” Page 2 / 3


NOTE: According to Section 7.8.2.1 of Standard ISO-IEC 17025:2017, it is stated that the results of the present certificate apply only and exclusively to the
samples subjected to test.
VIRLAB, S.A.
Division of URBAR INGENIEROS, S.A.
Vibration Test Laboratory

The applicable Required Response Spectra, RRS (5% damping), for both the horizontal (front-to-back, X
and side-to-side, Y) and vertical directions, are the described in figures included here below:

EN60068-2-57_H-AG5 EN60068-2-57_V-AG5
100 100

Requested Response Spectrum (Damping: 5%) Requested Response Spectrum (Damping: 5%)
Level AG5 (ZPA=0.5 g) Level AG5 (ZPA=0.25g)
Horizontal "X&Y" Directions Vertical "Z" Directions
IEC 60068-2-57 IEC 60068-2-57

10 10
Acceleration (g)

Acceleration (g)
1 1

0,1 0,1
1 10 100 1 10 100
Frequency (Hz) Frequency (Hz)

EN60068-2-57_H-AG5 EN60068-2-57_V-AG5

The Cabinet has successfully passed the Seismic Tests to which they have been subjected, no structural
anomaly being detected in the final visual inspection performed at the Laboratory.

Test report number 203009 of VIRLAB, S.A., includes all the information obtained, with tables,
photographs, used measuring devices calibration certificates, and other relevant information.

VIRLAB, S.A.
Division of URBAR INGENIEROS, S.A.
Revised and authorized by: Carried out by:
Firmado Firmado
digitalmente por digitalmente
por Iñaki
Juan Antonio
Labaien
Pérez Ruiz Fecha:
Fecha: 2020.03.09 2020.03.06
12:21:22 +01'00' 11:00:07 +01'00'

Juan Antonio PÉREZ Iñaki LABAIEN


Laboratory Manager Laboratory Engineer

Certificate number “203009C1” Page 3 / 3