CHAPTER 3 - POWER TRANSMISSION EQUIPT.

, PRTME MOVERS, MACHINES AND MACHINE PARTS

rod, 20 mm x 20 mm x 3 mm angle parts are guarded and the lubricating


iron or some other metal devices, are piped outside the guard.
construction of at least equivalent
strength. c. Transmission equipment, machines and
machine parts in inaccessible locations,
3. Trough or "U" guards shall be which are to be lubricated while they are in
constructed of material specified in motion, shall be equipped with extension
Table 3.1. Edges shall be smooth lubricant fittings or other methods of
and, if the size of guard so requires, lubrication which can be serviced from an
these edges shall be reinforced. accessible location.

4. An enclosure guard shall be Guarding of Flywheels


constructed of material specified in
Table 3.1, except for standard a. Prime Mover Flywheels. Any exposed part
railing; and shall be so installed that of a flywheel 2 100 mm or less above
it completely guards the power working level shall be guarded.
transmission equipment or moving
parts so that physical contact is b. When a flywheel extends into a pit or is
prevented. within 300 mm of floor and a standard railing
guard is used, a standard toe board shall
c. Railing guards and toeboards where also be provided.
required under any item in this code shall
comply with the provisions of Section 2.3.7. c. When it is necessary to move, swing, spin or
push flyruheels for starting, guards may be
3.3 Clearances removable or provided with momentary
openings which shall immediately closed
a. Where the guard or enclosure is within 100 after such starting operation is completed. A
mm from the moving parts, openings on the slot opening for jackbar will be permissible,
guard shall be of such size as will prevent as provided in Section 3.5 D.
passage of any object greater than 12 mm
in diameter. d. Every jackbar should be equipped with a
hand stop so located that it will safely clear
b. Whgre guards are located more than 100 the flyrwheel guard when fully inserted but
mm and less than 380 mm from moving will prevent the worker's hand being pinched
parts, the maximum opening shall not be between the slot and bar.
more than 50 mm and where slotted guards
are used, the width of the opening shall be e. Machine Flywheels. Machine flywheels
not greater than 25 mm. having spokes (or parts equivalent to
spokes), or projections, any part of which is
c. Standard railing guards shall be placed no 2 1O0 mm or less above floor or working
less than 380 mm no more than S00 mm level shall be guarded.
from any moving parts, provided however
that where clearances from other moving 3.6 Flywheel Ball Governors: Fty Ball Governors
parts of are less than 380 mm, such parts located 2 135 mm or less above the floor,
shall be guarded as required elsewhere in platform or working level having rotating,
this code. projecting or sectional parts, or hazardous
recesses shall be guarded.
Opening for Lubrication

a. Where application of lubrication must be


, 3.7 Conveyors:
done, openings with hinged or sliding covers a. Screw conveyors 2 100 mm or less above
shall be provided. floor or other working level shall be
completely covered with substantial lids
b. Where machines or machine parts must be except that screw conveyors 600 mm or less
lubricated while in motion the lubricating from its top to the floor or working level,
devices shall be located at least 300 mm whether its axis be above or below the
from dangerous moving parts unless such level which may be guarded by standard