This document summarizes guarding requirements for power transmission equipment, prime movers, machines, and machine parts. It outlines that:
Guards must be made of durable materials like metal and edges reinforced if needed. They must fully prevent contact with moving parts. Railing guards and toeboards are also required in some cases. Openings on guards within 100mm of moving parts must prevent objects larger than 12mm from passing through. Slots must be 25mm or less if between 100-380mm from moving parts. Flywheels under 2.1m must be fully guarded. Jackbars and hand stops are required for some flywheels. Screw conveyors under 1m must be fully covered by lids.
This document summarizes guarding requirements for power transmission equipment, prime movers, machines, and machine parts. It outlines that:
Guards must be made of durable materials like metal and edges reinforced if needed. They must fully prevent contact with moving parts. Railing guards and toeboards are also required in some cases. Openings on guards within 100mm of moving parts must prevent objects larger than 12mm from passing through. Slots must be 25mm or less if between 100-380mm from moving parts. Flywheels under 2.1m must be fully guarded. Jackbars and hand stops are required for some flywheels. Screw conveyors under 1m must be fully covered by lids.
This document summarizes guarding requirements for power transmission equipment, prime movers, machines, and machine parts. It outlines that:
Guards must be made of durable materials like metal and edges reinforced if needed. They must fully prevent contact with moving parts. Railing guards and toeboards are also required in some cases. Openings on guards within 100mm of moving parts must prevent objects larger than 12mm from passing through. Slots must be 25mm or less if between 100-380mm from moving parts. Flywheels under 2.1m must be fully guarded. Jackbars and hand stops are required for some flywheels. Screw conveyors under 1m must be fully covered by lids.
rod, 20 mm x 20 mm x 3 mm angle parts are guarded and the lubricating
iron or some other metal devices, are piped outside the guard. construction of at least equivalent strength. c. Transmission equipment, machines and machine parts in inaccessible locations, 3. Trough or "U" guards shall be which are to be lubricated while they are in constructed of material specified in motion, shall be equipped with extension Table 3.1. Edges shall be smooth lubricant fittings or other methods of and, if the size of guard so requires, lubrication which can be serviced from an these edges shall be reinforced. accessible location.
4. An enclosure guard shall be Guarding of Flywheels
constructed of material specified in Table 3.1, except for standard a. Prime Mover Flywheels. Any exposed part railing; and shall be so installed that of a flywheel 2 100 mm or less above it completely guards the power working level shall be guarded. transmission equipment or moving parts so that physical contact is b. When a flywheel extends into a pit or is prevented. within 300 mm of floor and a standard railing guard is used, a standard toe board shall c. Railing guards and toeboards where also be provided. required under any item in this code shall comply with the provisions of Section 2.3.7. c. When it is necessary to move, swing, spin or push flyruheels for starting, guards may be 3.3 Clearances removable or provided with momentary openings which shall immediately closed a. Where the guard or enclosure is within 100 after such starting operation is completed. A mm from the moving parts, openings on the slot opening for jackbar will be permissible, guard shall be of such size as will prevent as provided in Section 3.5 D. passage of any object greater than 12 mm in diameter. d. Every jackbar should be equipped with a hand stop so located that it will safely clear b. Whgre guards are located more than 100 the flyrwheel guard when fully inserted but mm and less than 380 mm from moving will prevent the worker's hand being pinched parts, the maximum opening shall not be between the slot and bar. more than 50 mm and where slotted guards are used, the width of the opening shall be e. Machine Flywheels. Machine flywheels not greater than 25 mm. having spokes (or parts equivalent to spokes), or projections, any part of which is c. Standard railing guards shall be placed no 2 1O0 mm or less above floor or working less than 380 mm no more than S00 mm level shall be guarded. from any moving parts, provided however that where clearances from other moving 3.6 Flywheel Ball Governors: Fty Ball Governors parts of are less than 380 mm, such parts located 2 135 mm or less above the floor, shall be guarded as required elsewhere in platform or working level having rotating, this code. projecting or sectional parts, or hazardous recesses shall be guarded. Opening for Lubrication
a. Where application of lubrication must be
, 3.7 Conveyors: done, openings with hinged or sliding covers a. Screw conveyors 2 100 mm or less above shall be provided. floor or other working level shall be completely covered with substantial lids b. Where machines or machine parts must be except that screw conveyors 600 mm or less lubricated while in motion the lubricating from its top to the floor or working level, devices shall be located at least 300 mm whether its axis be above or below the from dangerous moving parts unless such level which may be guarded by standard