CHAPTER 4.

MACHINERY DANGER ZONE AND POINTS OF OPERATION

when a visible signal such as a lamp is the charging floor or platform, a standard railing
operated by the motor circuit opening switch or enclosure shall be provided which will prevent
is open, and the safety device has been the operator from falling into the pan.
tripped, then after mill line has been stopped
by actuating one safety trip for the first test Section 13.0 Cofton and Seed Cotton
and before the mills are restarted, the Processing Machines
remaining safety devices may be tripped
and the lamp signals used as an indication 13.1 Saws:
of the proper functioning of the tripping
devices and motor switch. After a particular
,' stopping device has been used to stop the i a. Allgin stands used in processing field cotton
qith a positive
,r motor driv;ing a group of mills for a test, the
,i or seed shall be provided
prevent-
guard which shall be designed'to
same device may not be used for the same contact with the gin saws while in motion.
purpose until all the other devices have The saw blades in the roll box shall be
been similarly used. considered guarded by location if they do
not extend the ginning ribs into the roll box
b. Each stopping device shall be tested for when breast is in the out position.
braking distance once a week by a
competent person, and a record of such test b. Moving saws on lint cleaners having doors
shall be made and kept on file for at least giving access to the saws shall be guarded
one year. Such records shall pe available to by interlock barred barriers, or equivalent.
the division or its employees. ''
13.2 Gin Stand, Main Drive and Miscellaneous
c. The employer shall cause all defects or Drives.
substandard condition revealed by the test
to be corrected. a. Such drives shall be completely enclosed or
guarded by means of standard railings or
Section 12.0 Stone, Clay and Glass equivalent protection provided. When
Working Machines guarded by standard railing, where the
driver approaches the railing by less than
12.1 Pug Mills (Class A). Pug mills shall be guarded 380 mm, shield guards shall be installed on
by: the railing extending at least 380 mm
beyond the impairment on either side.
a. A substantial grating with openings no
greater than 100 mm, said grating to b. V-belt drives within standard railing
completely coverthe opening, or enclosures shall have the pulleys guarded.
The open end of the pulleys shall be no less
b. A cover proj6cting 100 mm on all sides that 100 mm from the periphery of the
which may be raised not more than 200 mm pulleys.
above the machine or floor, so as to permit
loading into machine on all sides without c. Chains and sprockets within 2 130 mm of
screening same through grating, or the floor or working level shall be guarded.
Chains and sprockets more than 2 130mm
c. A hoper completely encircling the opening from the floor or working level need not be
through which the machine is fed and guarded provided the bearings are packed
extending 400 mm or more above the blade. and accessible extension lubrication fittings
ln no case shall the top of the hopper be are used.
less than 900 mm from any floor or working
level used by the pug mill operators or 13.3 Elevated Platforms and Transmission
attendants. Enclosures.

d. Where automatic conveyor feed is used, a. Elevated platforms shall be guarded as


said conveyor shall be completely enclosed. provided in Section 2.3.9 of this Code.

12.2 Wet and Dry Pans, Mullers, Ghasers and b. Where belts, pulleys, chains, sprockets,
Similar Mixing and Grinding Mills (Glass A). gears or shifting are within 380 mm
When the top of pan is less than 914 mm above horizontally or less than 2 130 mm above

50