CHAPTER 6 - ELEVATORS, DUMBWAITERS, ESCALATORS AND MOVING WALKS

I Broken Drive-Chain Device. When the in the passenger carrying line of the trad
driving machine is connected to the main system.
drive shaft by a chain, a device shall be
provided which will cause the application of m. Tandem Operation. Tandem operatim
the brake on the main drive shaft and also escalators snatt Oe electrically interlocked
stop the drive machine if the drive chain where traffic flow is such that bunching uil
parts. occur if the intermediate landing stops'

g. Stop Switch in Machinery Spaces. A stop The interlocks shall stoP the
switch, conforming to the requirements of carrying passengers into the
Sec. 6.4.11.3 (e), shall be provided in each intermediate landing if the escalator
machinery space where means of access to passengers away from the landing
the space is provided. This switch, when These escalators shall also be electri
opened, shall cause the electrrie power to be interlocked to assure that they run in
removed from the escalator driving machine same direction.
rnotor and brake.
8.5.5 Signs. A caution sign shall be located at
Exception [Sec. 6.8.5 4 (g)]: Machinery top and bottom landing of each escalz
spaces in which main line disconnect switch readily visible to the boarding passengets"
is located. The sign shall include the following wording:
I

h. Skirt Obstruction Device. Means shall be a. Caution


provided to cause the opening of the power
circuit to the escalator driving machine b. Hold Handrail
motor and brake should an object become
wedge between the step and the skirt panel c. Attend Children
as the step approaches the upper and lower
combplates. d. Avoid Slides

Rolling Shutter Device. Rolling shutters, if The sign shall be standard for all
used, shall be provided with a device which and shall be identical in format, size,
shall be actuqted as the shutter begin to wording and pictorials as shown in Fig-
close to cause the opening of the power Appendix F.
circuit to the escalator driving machine
motor and brake. The sign shall be durable and have
maximum thickness of 6.5 mm with
Reversal Stop Device. Means shall be or beveled corners and edges.
provided to cduse the opening of the power
circuit to the driving-machine motor and 8.5.6 Access to lnterior. Reasonable access to
brake in case of accidental reversal of travel the interior of the escalator shall be provided
while the escalator is operating in the for inspection and maintenance.
ascending direction.
Section 9.0 Moving Walks
k. Step Demarcation Lights. Green step
demarcation lights located below the step 9.1 DesignRequirements
'shall be located at both landing in an area
not to exceed 406 mm fiom combplate. 9.1.1 Direction of Passage. Passage from a
There shall be a minimum of two fluorescent landing to a treadway or vice versa shall be in
lamp fixtures at each landing. The lamps , the direction of treadway travel at the point of
shall be activated whenever the escalator is passenger entrance or exit.
in operation.
9.1.2 Load Rating
Step Upthrust Device. Means shall be
provided to cause the opening of the power a. Structural. For the purpose of structural
circuit to the escalator driving machine design, the load rating shall be considered
motor and brake should a step be displaced to be not less than 4.78 kPa of exposed
against the upthrust tract at the lower curve treadwaY.