1. Type of cable that more often used in residential wiring installation.


a. NMSC b. PVC c. LBC d.USB
2. NM cable is used normally in _____ locations.
a. dry b. moist c. damp d. corrosive
3. NMC can’t be used in _____ locations.
a. dry b. moist c. submerges d. corrosive
4. NMC shall be protected by _______inches steel plate in a shallow chase concrete.
a.1/4 b. 1/16 c.1/2 d. 2
5. Among the type of NMSC, NMC is best use in what type of location?
a. dry b. moist c. submerges d. wet
6. Which of the following is best used in farm buildings or similar structures?
a. NM b. NMC c. NMS d. NMD
7. NMSC is also known as ___________?
a. WAWA b. CALTEX c. ROMEX d. POT
8. Romex is first introduced by what company?
a. Rome Wire and Cable Company
b. Robin Wire and Cable Company
c. Roldan Wire and Cable Company
d. Ryan Wire and Cable Company
9. NMSC is sold in lengths of 25, _____ and 100 feet.
a. 30 b. 50 c. 75 d. 60
10. Steel plate is required if the NSMC is ______ inches or less from the edge of the frame.
a.1-1/4 b. 1-1/16 c. 2-1/2 d. 2
11. Which of the following is the best tool to slit NSMC?
a. Hack saw b. Sheathing stripper c. Blade d. Knife
12. When cutting NSMC you have to leave at least how many feet?
a. 3 b. 5 c. 2 d. 6
13. How long should be the length of exposing NSMC wire inside the box?
a. 6–7” b. 6–8” c. 5–7” d. 8-10”
14. Check that about ____inch of sheathing is visible inside the utility/junction box
a.1/4 b. 1/16 c.1/2 d. 2
15. What is the maximum distance of staple wire from the box? (NEC)
a. 8” b. 5” c. 7” d. 6”
16. What is the maximum distance of staple wire from the box? (PEC)
a. 30cm b. 25cm c. 40cm d.36cm
17. It is the support used to hold the non-metallic sheathed cable in place.
a. Cement b. glue c. rugby d. Steel staple
18. FMT is commonly used for what terminal connection?
a. plastic b. motor c. roof d. Steel
19. FMT is usually sold in what length?
a. 50-200’ a. 32-200’ a. 65-200’ a. 11-200’
20. The minimum size of this type of conduit ranges from ___ to 1 ½ inches electrical trade size.
a.1/4 b. 1/16 c.1/2 d. 2
21. It is the support used to hold the flexible metallic tubing.
a. clamp b. staple c. glue d. Tape
22. It is the minimum length of conduit in a single roll.
a. 21’ b. 50’ c. 2’ d. 61’
23. FMT means ______________________________.
a. Fast Metallic Tubing
b. Flagstick Metallic Tubing
c. Foam Metallic Tubing
d. Flexible Metallic Tubing
24. It is the fitting used for joining flexible to metal conduit.
a. Connector b. glue c. rugby d. Steel staple
25. Which of the following that metallic conduits are allowed to be use?
a. dry b. wet c. hoist d. storage room
26. RSC means ______________________________.
a. Right Steel Conduit
b. Rigid Steel Conduit
c. Rigid Style Conduit
d. Rigid Steal Conduit
27. Rigid metal conduit has ______ inside diameter.
a. dry b. wet c. rough d. smooth
28. What is the standard length of RSC?
a. 40’ b. 10’ c. 2’ d. 60’
29. Standard diameter of RCS is ranging from ½”, ¾” up to ___ inches.
a. 41 b. 16 c. 11 d. 6
30. RCS should be protected by what chemical when it is subjected to severe corrosive influences?
a. Enamel b. wood c. soy d. Tape
31. It is the process of removing sharp edges left after cutting the pipe.
a. painting b. wooding c. reaming d. bending
32. What is another term used in sharp edges of pipe after cutting?
a. silk b. wool c. burr d. tip
33. What tool is used in threading RSC?
a. reamer b. cutter c. ruler d. dies and dies stock
34. What tool is used in cutting RSC?
a. reamer b. hacksaw c. ruler d. dies and dies stock
35. The sizes of dies stock ranges from ½ to ____ inches.
a. 41’ b. 16’ c. 11’ d. 6’
36. What tool is used in bending RSC?
a. hickey b. cutter c. ruler d. dies and dies stock
37. A _________ is recommended so that the pipe can be held firmly while it is being cut.
a. hickey b. cutter c. ruler d. bench vise
38. What tool is used in reaming RSC?
a. reamer b. cutter c. ruler d. dies and dies stock
39. Neutral conductor shall be placed ________.
a. anywhere b. separate circuit c. outside d. Within the same conduit
40. IMT means ______________________________.
a. Intermediate Metallic Conduit
b. In Meal Conduit
c. Instant Metal Conduit
d. In Man Conduit
41. It is the minimum size of conduit which can be installed in an industrial occupancy.
a. 8” b. 3/4” c. 7” d. 6”
42. It is a type of fitting which is used to change direction
a. connector b. coupling c. adaptor d. elbow
43. _______ are used for the installation of electrical wiring fixtures such as switches, etc.
a. electrical boxes b. coupling c. adaptor d. elbow
44. Intermediate metallic conduits are available in trade sizes ½” through _____ inches.
a. 14” b. 4” c. 12” d. 11”
45.It is used between conduit or tubing and items such as boxes or enclosures between two boxes.
a. electrical boxes b. nipple c. adaptor d. elbow
46. _______ is a device connecting two pieces of pipes in order to extend their length.
a. connector b. coupling c. adaptor d. elbow
47. Splices and taps must not be made inside the ________.
a. connector b. coupling c. raceway d. elbow
48. Do not use a raceway to support the enclosure except as permitted by the _______.
a. NEC b. PVC c. LBC d.USB
49. Overhead service conductor shall be run in what conduit?
a. metallic b. PVC c. wood d.soil
50. What is the maximum size of the home run conduit tubing?
a. 8” b. 3/4” c. 7” d. 6”
Address: RC-11 Barangay Citrus, City of San Jose del Monte, Bulacan
Email: 307508.sjdmc@deped.gov.ph
School ID: 307508
FB Account: DepEd Tayo Citrus National High School 307508
1 , 1 CITRUS National High School
ANSWER KEY

1 A 26 B
2 S 27 D
3 C 28 B
4 B 29 D
5 D 30 A
6 B 31 C
7 C 32 C
8 A 33 D
9 B 34 B
10 A 35 D
11 B 36 A
12 C 37 D
13 D 38 A
14 C 39 D
15 A 40 A
16 A 41 B
17 D 42 D
18 B 43 A
19 A 44 B
20 C 45 B
21 A 46 B
22 B 47 C
23 D 48 A
24 A 49 A
25 A 50 B

You might also like