You are on page 1of 28

REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT

In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: Sep 29 2022 4:08PM 128582

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3 Ton x 6 Meter Web Sling
Serial #: 191147861
Category: Web Sling
Manufacturer: Liftking
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 29/09/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: N/A 127888

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3 Ton x 6 Meter Web Sling
Serial #: 191147861
Category: Web Sling
Manufacturer: Liftking
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
29/03/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 29/09/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: N/A 127889

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3 Ton x 6 Meter Web Sling
Serial #: 191147862
Category: Web Sling
Manufacturer: Liftking
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
29/03/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: Sep 29 2022 4:09PM 128583

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3 Ton x 6 Meter Web Sling
Serial #: 191147862
Category: Web Sling
Manufacturer: Liftking
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: Mar 31 2022 4:30PM 128585

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 6.5 Ton Alloy Bow Shackle
Serial #: CL11N
Category: Alloy Bow Shackle
Manufacturer: George Taylor
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.5 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:49AM 116532

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 17 Ton Alloy Bow Shackle
Serial #: CL8N
Category: Alloy Bow Shackle
Manufacturer: George Taylor
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

17 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:06PM 128579

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 17 Ton Alloy Bow Shackle
Serial #: CL8N
Category: Alloy Bow Shackle
Manufacturer: George Taylor
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

17 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:34AM 116525

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 4 Leg Chsin Sling 10mm x 6 Meter c/w Shorteners and Self
Locking Hooks
Serial #: CLP567
Category: Chain Sling
Manufacturer: Chains Limited
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.7 Tonne @ 0-45 degrees 4.75 Tonne @45-60 degrees, None Yes No
Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:03PM 128584

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 4 Leg Chsin Sling 10mm x 6 Meter c/w Shorteners and Self
Locking Hooks
Serial #: CLP567
Category: Chain Sling
Manufacturer: Chains Limited
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.7 Tonne @ 0-45 degrees 4.75 Tonne @45-60 degrees, None Yes No
Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: N/A 116534

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Safety Shackle
Serial #: GOB30
Category: Alloy Safety Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:08PM 128593

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Safety Shackle
Serial #: GOB30
Category: Alloy Safety Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:49AM 116527

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 2 Leg Chain Sling 13mm x 8 Meter c/w Shorteners and Self
Locking Hooks
Serial #: HIS1596
Category: Chain Sling
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

7.5 Tonne @ 0-45 degrees 5.3 Tonne @ 45-60 degrees, None Yes No
Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:04PM 128588

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 2 Leg Chain Sling 13mm x 8 Meter c/w Shorteners and Self
Locking Hooks
Serial #: HIS1596
Category: Chain Sling
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

7.5 Tonne @ 0-45 degrees 5.3 Tonne @ 45-60 degrees, None Yes No
Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:49AM 116526

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 2 Leg Chain Sling 13mm x 8 Meter c/w Shorteners and Self
Locking Hooks
Serial #: HIS1597
Category: Chain Sling
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

7.5 Tonne @ 0-45 degrees 5.3 Tonne @ 45-60 degrees, None Yes No
Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:04PM 128589

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 2 Leg Chain Sling 13mm x 8 Meter c/w Shorteners and Self
Locking Hooks
Serial #: HIS1597
Category: Chain Sling
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

7.5 Tonne @ 0-45 degrees 5.3 Tonne @ 45-60 degrees, None Yes No
Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: N/A 128592

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M1
Category: Alloy Bow Shackle
Manufacturer: George Taylor
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:49AM 116528

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M2
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:05PM 128591

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M2
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:05PM 128590

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M3
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:49AM 116529

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M3
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:48AM 116530

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M4
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:05PM 128587

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 3.25 Ton Alloy Bow Shackle
Serial #: M4
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

3.25 Tonne, None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:09PM 128586

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 6.5 Ton Alloy Bow Shackle
Serial #: M7
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.5 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:47AM 116531

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 6.5 Ton Alloy Bow Shackle
Serial #: M8
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.5 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:05PM 128581

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 6.5 Ton Alloy Bow Shackle
Serial #: M8
Category: Alloy Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.5 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 04/05/2022 Report #: Colour Code: NO COLOUR Job No: 12054
Date of Last Thorough Examination: Nov 5 2021 10:47AM 116533

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 6.5 Ton Alloy Bow Safety Shackle
Serial #: RB2
Category: Alloy Safety Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.5 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
04/11/2022

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland
REPORT OF THOROUGH EXAMINATION OF LIFTING EQUIPMENT
In accordance with the Safety, Health and Welfare at Work (General Applications) Regulations SI 299 of 2007
Date of Thorough Examination: 12/10/2022 Report #: Colour Code: NO COLOUR Job No: 12377
Date of Last Thorough Examination: May 4 2022 5:06PM 128580

Name and Address of employer for whom the thorough examination was Address of premises at which the examination was made:
made:

Gabriel O'Brien Crane Hire limited Crane 105


Unit 6 Red Cow Business Park Unit 6
Naas Road Red Cow Business Park
D22 TR50 D22TR50

Description and identification of the equipment: Date of manufacture if known:

UNKNOWN
Description: 6.5 Ton Alloy Bow Safety Shackle
Serial #: RB2
Category: Alloy Safety Bow Shackle
Manufacturer: Unknown
Asset:

Safe Working Load/WLL/Load Test: Purpose of Examination:

6.5 Tonne , None Yes No


Periodic Examination ü
Examination before putting into use for the first time ü
Examination after installation or after assembly at a
new site or in a new location ü
Examination after repairs or alterations ü

Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect (If none state NONE):

NONE

Is the above a defect which is of immediate danger to persons? YES NO ü


In the case of a defect which is not yet but could become a danger to persons:
The time by which it could become a danger: N/A
Particulars of any repair, renewal or alteration required to remedy the defect identified above:

NONE

Identification of any parts not yet accessible for examination:

NONE

Particulars of any tests carried out as part of the examination: (If none state NONE):

NONE

IS THIS EQUIPMENT SAFE TO OPERATE? YES ü NO

Name of person making this report: Latest date by which next thorough
examination must be carried out:
Sean Haire
12/04/2023

Name and address of employer of persons making and authenticating this report:
251 Richmond Rd, Fairview, Dublin 3, D03 AX66, Ireland