You are on page 1of 1

ALMANSOORI INSPECTION SERVICES

LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT


This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Report Number: 5010046715-BP-001 Date of Report: 03-Nov-2021


Job Allocation No: 5010046715 Type of Inspection: Visual & MPI
Name and Address of Owner Place of Inspection Sub location
ADES ADES-13 Rig Site
Due Date of Next Date of Last Proof Due Date of Date of Last
Date of Inspection
Inspection Load Test Next Proof Load Test Inspection
26-Dec-2019
03-Nov-2021 02-Nov-2022 25-Dec-2022 03-Nov-2020
Cert: 28923-001
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)

BOP Lifting Plates 50 t


N/A
Each Plate
4512017067-10-1 Thickness: 85 mm 1
4512017067-10-2 Upper Hole Dia: 75 mm Pair Manufacture Year of
Lower Hole Dia: 235 mm Name Manufacturing
Bolt Hole Dia: 40 mm Cameron Unknown
Applicable Reference Standards : API RP 7L
Applicable Reference Regulations: SWIM
Colour Code: White till the end of March, then Green
MPI valid until 02-Nov-2022.
NDT Details (if Any):
MPI Acceptable (5010046715-BP/MPI-001)
Test Equipment Details: S/N: 1904036
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☐ No☒
Was the examination carried out Within an interval of 12 months? Yes☒ No☐
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & MPI
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA &NDT Level II

Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018