HSE Observation Report

Date: 26-12-2022
Potential
Location Action required /
S.no Issues Photograph Risk Rectification Close Out Photo
Recommendations
Level
WAH & safe work
platform training
given to operatives
Contractor need to and warning letter
Operative was found provide a safe & proper Life issued .
working unsafe working platform and Critical
Basement- while performing the One
1 conduct awareness working
1 job, potential risk of training to the workforce day
fall from height regarding safe working
platform

Energized electrical
cables have been
removed and tie
Contractor need to with ceiling non
Observed that ensure that all energized Life conducting
energized electrical electrical cables direct Critical material .
Level-1, cables kept on the contact with metal must One
2
A02-B scaffold, Potential be remove ,advise working
risk of electrocution operatives do not kept day
or electric shock cables on scaffold
material or any metal
HSE Observation Report

Damaged plug
replaced and new
Contractor need to inspected plug
Observed that ensure that, All power provided by site
operative was using tools cables and power Life electric team .
Damaged power sockets must be in a Critical
Basement- plug/ Socket, One
3 good condition, working
1 potential risk of inspected prior to use by day
electrocution and a competent person, all
short circuit damage sockets must
remove from the site

Ladder safety
training given to
operatives and
warning letter
Contractor must take issued .
Observed that Life
appropriate/ disciplinary Critical
Unsafe / without
Basement- support of A Frame action on operative for One
4 working
1 miss use of ladder,
ladders was using by day
conduct training
Meras Operative
regarding ladder safety
HSE Observation Report

Energized electrical
cables have been
Contractor need to removed from the
ensure that all electrical floor and fixed with
Observed that Ceiling .TBT
cable must be removed Life
energized electrical Critical conducted with
from the water, conduct
5 Basement- cables passing from TBT to their operatives
One operatives regarding
1 the water, potential working electric safety and
about electrical cables day
Risk of electrocution cable management .
and provide protection
and short circuit
to prevent any
electrocution

Protruding rebars
has covered with
rebar caps .

Contractor need to Non-Life


Unprotected ensure that all Critical
6 Basement- protruding rebar’s protruding rebar’s are 1>3
1 were observed at well protected/ covered working
Chemical Storage with rebar caps if cannot day
be eliminated.
HSE Observation Report

Scaffold inspection
conducted by
scaffolding
Operative was found inspector and tag
using incomplete Contractor need to Non-Life provided . TBT
scaffolding platform, ensure that all Critical conducted with
7 Basement- without valid scaffolding platform 1>3 operatives regarding
1 inspection tag, No must be inspected by a working scaffolding and
access available , No certified scaffold day
WAH.
Evidence of inspector prior to use
inspection conducted

Power tools
inspection
conducted by site
Several power tool Contractor need to electric team and
were found without ensure that, All power Non-Life colour code
monthly inspection tools must be inspected Critical updated .
Basement- color code. Evidence 1>3
8 prior to use by a working
1 that monthly competent person and day
inspection not being color code must be in
conducted place
HSE Observation Report

Refresh Ladder
safety training given
to operatives and
verbally worn
Contractor must take Non-Life
Un safe (Two were appropriate/ disciplinary Critical
9 Basement- found using same action on operative for 1>3
1 time) A frame miss use of ladder, working
ladder conduct training day
regarding ladder safety

Handing cables
have removed and
routed separately
from the access .

Poorly routed
Contractor need to Non-Life
electrical cable was Critical
ensure that all Energized
Basement- observed, energized 1>3
10 cables must be routed
1 cable was found working
separately from the day
hanging at drive
access
access,
HSE Observation Report

Power tools
inspection
conducted by sire
electric
Contractor need to team .Damaged
ensure that all power Non-Life cables have
Damaged cables tools must be inspected Critical replaced.
1>3
11 Basement- using on the site for prior to use. All working
2 power tools damaged electrical cable day
must be repaired and
fixed properly

WAH and full body


safety harness
training given to
Contractor need Ensure operatives.
that all operatives are
Observed that Non-Life
trained and competent Critical
operative from
Basement- (Meras) was found when working at 1>3
12
1 heights, Conduct working
wear full body day
awareness training
harness incorrectly
regarding the use of full
body harness
HSE Observation Report

Damaged
homemade hand
tools have replaced .

Observed altered
Contractor to ensure that
tools were using by Non-Life
homemade/ altered tools Critical
al Bawani
are prohibited on site. 1>3
13 A02, A05 subcontractor
All homemade tools working
operatives, evidence day
must be removed from
of homemade tools
the site
used on site

Housekeeping has
conducted and
waste material
Contractor need to disposed .
advise their sub
Poor housekeeping contractor remove the Non-Life
Critical
Basement- was observed at waste from site on
1>3
14 1 several places, regular basis, and working
evidence of Poor maintain a good day
Housekeeping housekeeping at all
over the building
premises

Prepared by:
Mohammed Vajid Ali
HSE Observation Report

Life Critical Major failure e.g. fatality, LTI, major injury, or Immediate> 1 Working day (if not temporary suspended)
dangerous occurrence
Non-Life Critical Potential Minor injury Incident, Environmental or 1 > 3 working day
Welfare Issue.
Good Practice N/A None however look to share good practice