2015/09/28 Pump Control (Negative Flow) - Adjust (RENR3201-04)

SMCS - 3222 i00992148

PSP
202 -0005
07: 3/01/0 C6FA
2
RE 9:57+ 7
N
© 2 R32 03:00
Illustration 1
Pump compartment
(27) Setscrew
0
Cat 3 C 1
2 0
g00363732

(28) Locknut
(29) Setscrew
(30) Locknut
e
Con rpilla aterpi
fide r: llar
Note: Use the same procedure for both pumps. Use locknut (28) and setscrew (27) for the upper pump
adjustment. Use locknut (30) and setscrew (29) for the lower pump adjustment.

ntia Inc
.
1. In order to adjust the upper pump, loosen locknut (28).
lG
ree
2. Turn setscrew (27) until the negative flow rate is adjusted to the correct specification.

n
Note: A clockwise adjustment of setscrew (27) and setscrew (29) decreases the flow rate. A
counterclockwise adjustment increases the flow rate. A quarter turn of setscrew (27) and setscrew
(29) will change the flow rate approximately 2.5 L/min (0.7 US gpm) at a system pressure of
2650 kPa (385 psi).

3. Tighten locknut (28) to a torque of 12 ± 3 N·m (9 ± 2 lb ft).

4. Adjust the lower pump. Use locknut (30) and setscrew (29) instead of locknut (28) and setscrew
(27) to adjust the lower pump.