3.6 Hoistway
3.6.1 Landing door state ----------------------------------- 87
3.6.2 Limit switch ----------------------------------- 94
3.6.3 Hoistway electric wire/ Tail Cord- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 95
3.6.4 Hoistway Main Rail ----------------------------------- 96
3.6.5 PRS (used for guide plate)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 97
3.6.6 Top seam ----------------------------------- 98
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 87/N
3.6 Hoistway
The manual mainly introduces content about IRIS NV elevator maintenance wo
rk only. Therefore, the manual does not include detailed technology details, ple
ase refer to IRIS NV elevator assembly manual or test-running adjustment man
ual and other relative data.
Notice
When enter into the hoistway, “Access procedures for upper part
of car (WWJSSS)” must be followed.
Please take falling-proof measures for area with falling danger.
Please do not stride across upper parts of near elevators.
Please do not bend upper body near hoistway.
Please prevent from colliding with counterweight device, it may
bring about serious damage accident.
If cracks occur on hoistway wall or concrete block falls, report to
building administrator and take corresponding measures.
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 88/N
Ruler,
Seam between door and door when
naked 2.5~4mm 1 month
door is closed completely
eyes
Naked
Cushion state eyes,
Normal assembly 1 month
(assemble, anti-noise function) acoustic
sensation
Assembly state of safety window Naked
3 months
(damage, fixing part relaxes, cleans) eyes
More than 215kgfcm
Determine fastening state of bolts
(about 200mm deep,
used for connecting of hanger and Wrench 3 months
degree of fastening
door
by wrench)
Fixing part on hanger roller side Wrench 3 months
Flatness (bending) of hanger (plate) Wire, iron
3 months
Door hanger roller ruler
Clearance between slide way roller
Gap gauge 0.2~0.5mm 3 months
and guide rail lower end face
Naked
Polyurethane abrasion Whether it falls 3 months
eyes
Acoustic
Rotary noise of roller 3 months
sensation
Remove foreign matters and rust on Personal
Door rail 3 months
door guide rail tool
Ruler,
Determine tension adjusting value of
naked Spring size 20±1mm 3 months
connecting wire of hanger
eyes
Keep the state that
Through determining holes, determine
Naked rope state could be
Connecting whether there is abnormal condition 3 months
eyes observed through
rope on coating part of lower end of rope.
determining hole
Naked
Check whether rope is abnormal Enwind, Strand break 3 months
eyes
Naked
Determine rope roller damages (resin) 3 months
eyes
Naked
Fixing part is relax 3 months
eyes
ⓐmore than 5mm
Spring state:
ⓑexisting is not
Closer Spring ⓐanti-conflict clearance Naked
allowed
ⓑCracks eyes, 3 months
ⓒkeep conformance
ⓒPitch collision
ⓓRusting ⓓexisting is not
allowed
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 89/N
Transfer
Verticality of door & window jamb Awl, ruler
inspection
Door &
When door is opened completely, Ruler, Opening degree is
window jamb ±2
taking door & window jamb as naked 6 mm larger than 3 months
standard one, open section size eyes door & window jamb
Personal Relaxation is not
Set fixing state of sill 12 months
tool allowed
Brush,
Sill surface ⓐcleaning, ⓑimprint naked 6 months
eyes
Naked
Clearance between door lower end
eyes Within 5±1 mm 3 months
and sill
(ruler)
Relaxation is not
Sill Fixing state of door guide shoe Driver 1 month
allowed
Naked Replace it if more
Abrasion state of door guide shoe 1 month
eyes than 1mm
Keep distance for
Distance fore door guide shoe enters Naked
entering groove be 1 month
into sill groove eyes
longer than 12mm
If width of groove
Determine abrasion degree of sill (sill Naked
increases 1mm, 6 months
groove width) eyes
replace it.
Determine opening with manual
Determine opening 1 month
switch (adjusting state of control lever)
Determine that forceful opening is
conducted under that state that the Hands 1 month
Manual locking device is not opened.
open/close Wiring state, limit value and fixing Naked Conflict with car is not
1 month
state of switch rope eyes allowed
Whether ruler crossing is conducted in Hands,
It is different according
overall field of door ruler force naked 1 month
to entrance width
Close(20mm before completing) eyes
Seam between hook and locking
device
Left-right direction:
±0.5
Naked 3 mm
Door interlock 1 month
eyes Up-down direction:
and door
3 mm
switch
S/W Tip
Dead-lock size under that state that
Stroke : 3.5±1.5 11.5 mm 3 months
door interlock is closed
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 90/N
Naked ±0.5
Determine travel of locking action 13.5 mm 1 month
eyes
Over travel at contact
Over travel in state of that door switch Naked
point center: 1 month
is On eyes
3.5±1.5mm
Before determining that switch is in
Naked
opening state, whether door interlock Determine action 1 month
eyes
is hanged on door interlock firstly.
In low-speed
operating, under the
state of the door
Naked interlock is not
Adjusting state of door interlock and eyes, released, pull door
1 month
door switch (figure) personal toward opening
tool direction forcefully,
the influence on
operating is not
allowed.
Whether fixing state of door switch Naked Relaxation is not
1 month
and earthing wire conflict mutually eyes allowed
Clearance between
centers of two sides
Determine adjusting state of coupler Naked
is 14(-2,+0)mm 1 month
rail and roller eyes
wall face is 10(-0,
+2)
mm
Ruler,
Determine gap between door interlock +2, -1
Door interlock naked 8 mm. 1 month
roller and car sill
roller eyes
Determine overlapped size of guide Naked
14±2 mm 1 month
rail and roller. eyes
Determine clearance of rotary shaft of Naked End of door interlock
1 month
Interlock Asy eyes is within 5mm
Whether noise occurs when door Acoustic
1 month
interlock acts sensation
Distance from car sill
Determine state of assembly, fixing Naked
Fascia Plate end to wall face is 12 months
and rusting eyes
less than 125mm
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 91/N
Notice
When carry out shorting stud on door switch, the work should be co
nducted by professional worker under conditions approved by admin
istration supervisors.
Please prevent that door non-vision part is damaged.
Entrance center
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 92/N
part is fixed completely in eyes, however, when adopt forcefully push or pull one side
door toward left or right, deformation (movement) may occur sometimes. At this point,
please inspect bolts of door and hanger and bolts fixed in horizontal direction on its
hanger, and fasten those bolts.
(3) When check fixing part of door interlock, please adopt tools to fasten it (determine
whether it is relaxed).
(4) Please determine gap (73mm) between landing guide rail and car door sill.
(5) Determine whether deviation of car sill center and car door rail center is within±1mm.
1) Center marking point of car door frame → mark it on frame by marking line
2) Center marking point of landing door frame → in 3 fix screws with caps, the middle
one is center point.
(6) Please determine vertical deviation between position which is 43mm away from landing
door sill end to landing door guide rail face is within±1mm to determine verticality of the
frame.
(7) Please determine whether gap between slide-way roller and lower end of guide rail is wit
hin 0.2~0.5mm.
3.6.1.2 Hanger
(1) Under the condition that door clamp (connecting bolt) assembled on hanger and door
connecting part flap-door is not fastened completely (more than 215kgfcm, about
200mm long wrench’s fastening), if door acts normally, no problem occurs; however, it
may crack in forceful condition (if the door can not be closed or forcefully baffled to be
closed because there is foreign matter in sill groove).
(2) Considering maintenance, adopt bolts to fix hanger roller; therefore, please determine
whether bolts are relaxed.
(3) When adjust roller (slide-way roller) at bottom of hanger assembled at bottom of door gui
de rail, please keep clearance between roller and guide rail is 0.2~0.5mm.
3.6.1.3 Door rail
(1) Please determine fastening state of fixing bolt of guide rail.
(2) Adopt proper tool to remove dust or contaminant on guide rail surface.
(3) If the rail surface rusts or is damaged, please apply fine sand paper (more than #
800), remove rust and dust on the surface.
3.6.1.4 Connecting rope of hanger
(1) When adjust connecting rope of hanger, under the condition that door is closed, keep ten
sion spring size is 20mm (if tension force is great, action of door may be out of line).
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 93/N
(2) If there are 20 damaged parts on each 10cm connecting rope, please replace it. Howeve
r, when inspect the rope, if there is 5 damaged parts found on the rope, it could be replac
ed as well.
(3) Please determine whether D-Nut used for adjusting tension is relaxed, whether handling
state of rope end (gap-filling falling) deforms. (If use in long term, cracks may occurs for r
epeat fatigue.)
(4) Please determine whether fixing bracket of rope is relaxed. (At this point, it is possible th
at the door can not be started at the same time.)
3.6.1.5 Door closer spring
(1) Determine whether fixing part of spring cracks by observing with naked eyes or knocking
sound.
(2) Please determine whether landing door closes relying on its own force.
3.6.1.6 Door & window jamb
(1) Please determine whether it is made to be swaying caused by that fixing part of
door & window jamb relaxes.
3.6.1.7 Sill
(1) Please clean foreign matters in sill groove.
(2) After inspecting abrasion degree of sill groove, if abrasion degree of initial groove width is
more than 12mm--3mm, please replace it.
(3) When use is for a long term, for reasons that adopt water to conduct cleaning, it is
possible that seam occurs between ground and sill, thus, conflict with guide shoe may
occur.
(4) Please determine sill horizontality (front-back: 0±1mm, left-right: ±1.5mm in EW).
(5) If the distance for that door guide shoe enters into sill groove is not up to 10~12mm,
please adjust joint part between door and hanger, and adjust the door downward.
3.6.1.8 Manual opening rope
(1) Please determine whether it could be started with manual opening key from outside and
whether fixing part is loosened.
(2) Please determine fixing state of opening rope. Please determine whether conflict caused
by that it is loosened too greatly in elevator running process; and whether opening-closing
action is baffled by that it is too tight.
3.6.1.9 Door interlock (Interlock Asy.)
(1) Under the state that the door is closed completely, left-right and up-down clearance
between door interlock hook and latch is 3±0.5mm.
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 94/N
(2) Please determine whether door interlock and hook have conflict caused by shifting of
fixing shaft of interlock roller.
(3) Please adjust door interlock and hook according to following figure.
(4) When adjust door switch contact point, if over travel is not ensured, running travel door of
elevator vibrates or external force occurs at door surface. At this point, sudden stop
occurs accidentally, and the condition brings about that it is difficult to maintain.
(5) Under the state of low-speed running and not unblocking, when manually and forcefully
pull aside door interlock to determine opening state of door, elevator should not stop.
Entrance center
Door rope
Door rail
Up-force roller
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 95/N
Fascia
Plate
125mm 이하
Less than과125mm
(Car Sill Fascia Plate
간격)between Car Sill and Fascia Plate)
(gap
(1) Please make switch roller act with hand to determine whether reset is smooth and
whether noise occurs.
(2) Please supply oil to roller shaft holes to prevent noise occurring in rotating of roller.
(3) Please determine whether contact point of switch rusts or discolors.
(4) After wiping contact point of switch with oil, adopt dry cleaning cloth to clean it up. It
should be prevented that oil contacts with rubber. Rubber will deforms easily.
(5) Action position of contact point is at the midpoint of contact point. Please determine
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 96/N
whether over travel of contact point is enough. If over travel of contact point is not
enough, when elevator operates, no-good contact will occur for vibration, therefore, the
car may stop suddenly.
(6) Please determine whether terminal in switch box is loosened or whether there is foreign
matter or dead bug in the switch box.
(7) Please determine whether roller rubber deforms or cracks.
(8) Please determine whether switch cam is bent. Bending of middle part could bring about
faults by accident.
(9) For action time point of contact point of limit switch, please refer to “Elevator assembly
manual”
(10) Please inspect lower limit switch in pit (please refer to item 3.9).
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 97/N
Inspection
Part Inspection item Tool State/standard
circle
Naked
Determine fixing state of bolts of fixing eyes, Relaxation is not
6 months
part of EVV electric wire and clamp personal allowed
tool
Fix it at the
Determine junction box, wiring, fixing
Naked immovable position
state and fixing position (used for the 6 months
eyes which is convenient
Hoistway lowest floor)
for maintenance
electric wire
Whether electric wire armor is Naked
6 months
damaged eyes
Personal Loosening is not
State of fixing cap of junction box 6 months
tool allowed.
Brush,
Determine inside cleaning and socket
Naked 6 months
connecting state of junction box
eyes
Determine middle junction box and tail Naked
Fixing must be firm. 6 months
cord etc. fixing state. eyes
Determine connecting state of inside
Naked
socket and earthing wire of H-junction 6 months
eyes
box(middle junction box)
Whether car conflicts with electric wire Naked
Conflict is not allowed 6 months
in operating eyes
When care about that
Tail cord conflict will occur and
If it conflicts (protruded part, plug) with the conflict will make
Naked
hoistway wall face of tail cord moving electric wire 6 months
eyes
area, please take measures abnormal, please
mount safety net or
steel wire.
Clearance between lower end of tail
cord and hoistway ground when car is Ruler 350±50 mm 6 months
at the lowest floor.
(1) When car stops at the lowest floor, please determine whether clearance between tail
cord and car side face is kept to be more than 80mm; and determine clearance between
it and building. If the clearance is not kept within this range and it used for a long term,
friction will be broken because friction between tail cord and car.
(2) Please determine whether there is protruded matter in hoistway. If there is, please
remove it; and inspection should be conducted in pit under the car bottom.
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 98/N
(3) In car operating, it is not allowed that tail cord contacts with buffer.
(4) Please determine whether connecting socket part of electric wire is affected with damp,
and solve the problem. Take measures to prevent water drop penetrating, keeping it
flows smoothly (socket direction).
(5) When displace CCTV electric wire, its electric wire specification is very important. If
single wire is adopted, the line can not be used for a long term even though wiring is
conducted in any mode. Electric wire with core should be 19 strands/0.18mm stranded
cable, but not single wire.
(6) Please determine wiring state of CCTV electric wire, if there is abnormal condition,
please correct it.
(1) When replace guide shoe metal (friction material), please clean the guide rail.
(2) Please determine lubrication, cleaning and surface state of guide rail.
(3) Guide rail is assembled in 2.5m clearance generally. Guide rail’s correctness (flatness)
depends on assembly technology of elevator, and comfortable sensation is in proportion
with the correctness.
(4) Inspect clearance between upper end (ceiling) of hoistway and guide rail end, and keep
the clearance to be within 125mm; and keep 40mm clearance with hoistway floor.
(5) Under the condition that elevator stops at the top floor, guide rail at position (non-running
area of elevator) which is 100mm away from oil feeder top end should be treated with
anti-rust work.
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 99/N
(6) Determine relaxation degree of fixing part nuts of rail fixing bracket for each 1 year, and
fasten nuts again.
(7) Electric welding drawing used for flat washer of bracket fixing nuts is shown as follows.
Please determine whether welding part falls off.
5mm이상
More than 5mm t
슬롯 구멍보다
If washer is 슬롯 구멍보다
If washer is
와샤의
Washer size 크기 와샤가 클때
larger than slot 와샤가 작을때
smaller than slot
opening opening
(8) Adopt 1m ruler to inspect short difference of rail connecting part, short different at
both sides should be kept to be less than 0.2mm.
3.6.5 PRS (used for guide plate)
Notice
Inspection
Part Inspection item Tool State/standard
circle
Determine whether it conflicts with Naked
No conflict is allowed 6 months
elevator structure eyes
PRS
Naked Fixing state should be
Determine PRS fixing state 6 months
eyes firm
(1) When inspect adjusting state of PRS, please conduct inspection in order of that from
upper level to lower level.
(2) If implantation device passes through PRS, there will be noise; please determine fixing st
2005.12.27. Approval
Name IRIS NV Elevator Maintenance Rev. Date 2011.02.25
SIGMA Code OEMS-P1-111-000 Rev. No. 0
Standard Application Service Business Dept. Page 100/N
ate of PRS. If PRS is in the state of that it is fastened incompletely, there may be noise o
ccurs for magnetic force.
(3) Assembly state of PRS is shown as following figure.
2005.12.27. Approval