TECHNICAL SPECIFICATION:-

18.25 1. DO NOT SCALE THE DRAWING. FOLLOW ONLY WRITTEN


DIMENSIONS.

W/V1 W/V1 W/V1 2. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE


MENTIONED.
D3 V GW
3.THE STRUCTURAL DRAWING TO BE READ WITH RELEVENT

1.00
W.C ARCHITECTURAL DRAWING.
3000x1200
1.00 4.TYPE OF STRUCTURE :- R.C.C FRAMED STRUCTURE &
DESIGNED FOR (G+1).
FUEL
STORAGE DISH WASH 5. METHOD OF ANALYSIS :- FINITE ELEMENT METHOD
D3 METHOD OF DESIGN :-LIMIT STATE METHOD OF

2.96
3000x1250 3000x3650 DESIGN AS PER IS : 456-2000
V1 KITCHEN
D D 6. LOADS ON STRUCTURE :-
D PASSAGE 9000x5000
DEAD LOADS IS:875(PART-1)

7.96
3.23
LIVE LOADS IS:875(PART-2)

1.03
UP
V1 w w UP
EARTHQUAKE LOADS IS:1893-2002,IS:13920-1993
D D
V1 4.27

SERVICE COUNTER STORE 7. SPECIFICATION OF P.C.C / R.C.C WORK SHALL BE AS PER IS :


STORE 456-2000
2500 X 3650
3000 X 3650
2.73

PANTRY HAND WASH 8. CONCRETE GRADE :-


V V V V V V
HAND WASH 9000 X2500 4000 X 2500 R.C.C : M20, P.C.C :M10 UNLESS SPECIFICALLY STATED
4000 X2500
RO Unit RO Unit 1.27 9. (6.1) CEMENT FOR R.C.C WORK :- ORDINARY PORTLAND CEMENT
SERVICE COUNTER (6.2) REINFORCEMENT :- HYSD/fe 500 (#) : IS : 1786-2008.
(6.3) # INDICATES T.M.T, REINFORCEMENT.

10. NOMINAL COVER TO REINFORCEMENT :


FOOTING : 50mm BEAMS : 25mm
W W COLUMN : 40mm SLABS : 20mm
3.89 3.89
11. AGGREGATE TO COMPLY WITH REQUIREMENT OF I.S.383-1970

12. WATER USED FOR CONCRETING AND CURING SHALL BE IN


27.46 ACCORDANCE WITH ARTICLE 4.3,I.S.456-2000

13. LAPS TO BE STAGGERED AND NOT MORE THAN 50% OF BARS


SHALL BE SPLICED AT ONE SECTION.
9.46

W W 14. ADEQUATE CHAIRS, COVER BLOCKS TO BE PROVIDED FOR


REINFORCEMENT.

15. DEVELOPMENT LENGTH OF 50 TIMES THE DIAMETER TO BE


ADOPTED FOR ALL LAPINGS.

16. PROVIDE 25MM Ø PIN BARS BETWEEN TWO LAYERS OF BARS IN


DINING BEAM.
27000 X9000 DOCONSTRUCTION
17. NOT SCALE JOINTS SHALL BE AS PER I.S 11817.
W W
18. THE CANTILEVERED BARS AT TOP SHALL BE ANCHORED 1.50
TIMES THE CANTILEVER LENGTH AT THE BACK.

19. THE MAXIMUM OF THE TOP EXTRA BARS AT COLUMN SHALL BE


MD ADOPTED FOR TWO ADJACENT BEAMS.
1.80 W 20.ANY DISCREPANCY , IF FOUND, SHALL BE BROUGHT TO THE
W W W W W
R A M P 2.07 NOTICE OF STRUCTURAL ENGINEER WELL BEFORE EXECUTION.
27.46 UP

1.80
21. FOUNDATION DETAILS ARE BASED ON SBC OF SOIL AS 165kN/m²
AT A DEPTH OF D=2.20M

DO NOT SCALE
UP
3.02 OFFICE OF ORIGIN
27.46

DATE

DRAWN

CLIENT:- PRE-CHECKED

3.89 KARNATAKA RESIDENTIAL EDUCATIONAL


INSTITUTIONS SOCIETY
FINAL-CHECKED
PROJECT:-
KITCHEN & DINING BLOCK
APPROVED

TITLE:-
GROUND FLOOR PLAN
THIS DRAWING IS THE PROPERTY OF M/S PREMIER TECHNICAL CONSULTANTS. SCALE
IT SHOULD NOT BE USED COPIED OR REPORDUCED WITHOUT THEIR WRITTEN
PERMISSION