D.

LIFTING LUG TO COLUMN CONNECTION

1. Weld Check for Lifting Lug to Column


Using Full Penetration Groove Weld:

Complete Penetration Groove Weld Tension Capacity,

 
Rwcpt  Λ ty Fy min tpl tmin  Lwcp

Rwcpt  78.03  kN

Complete Penetration Groove Weld Shear Capacity,

 
Rwcpv  Λ vy 0.6 Fy min tpl tmin  Lwcp

Rwcpv  52.124 kN

Interaction of Equation for Full Penetration Weld Capacity,

2
 Nw    FwV   1.0
2
 Rw   Rw 
 cpt   cpv 
2  Fw 2
 Nw  V 
Icp     
 Rwcpt   Rwcpv 
Icp  0.593

RESULT = CJP Weld Capacity > Applied Force, OK

Lifting Lug Analysis 9 of 10