Professional Documents
Culture Documents
CONTRACTOR
NO COMMENT
COMPANY
1 Page 10 / Section - 15 007 NO COMMENT ITR Revised to Revision 2 Agreed Agreed Closed
Code 1 Accepted – Up-rev and Resubmit with applicable document lifecycle status code
Revise and Resubmit –Incorporate Comments, Up-Rev & Resubmit at the next document lifecycle
Code 2 status code – Work May Proceed
Rejected– Address highlighted deficiencies, Up-Rev and Resubmit at the next document lifecycle
Code 3 status code – Work May not proceed
Code 6 Information
Note: This sheet shall be the 1st cover page of all A3 & A4 documents. This block will also form part of the A3 drawing
template.
MAJNOON CPF 2 PROJECT
HOLD LIST
Hold
Para. Description of Hold
No.
DOCUMENT TITLE: Rev. 007
SITE POSITIVE MATERIAL
IDENTIFICATION TESTING Date:
PROCEDURE 26-Jul-2022
DOCUMENT NO.:
Page 3 of 14
MGP1-CP2-KMS-QA-6050-0003
TABLE OF CONTENTS
1 INTRODUCTION ................................................................................................................ 4
2 SCOPE .................................................................................................................................... 4
3 PURPOSE .............................................................................................................................. 4
4 REFERENCES ...................................................................................................................... 4
6 PERSONAL............................................................................................................................ 5
7 EQUIPMENT ........................................................................................................................ 5
8 PROCEDURE ........................................................................................................................ 6
1 INTRODUCTION
This procedure specifies the requirements of Positive Material Identification (PMI) for the
components/welds/weld consumables in material other than CS & LTCS by Khaerat MSK Al-Iraq
for MAJNOON CPF 2 PROJECT.
2 SCOPE
The Scope of this Procedure to check chemical composition for materials such as austenic stainless
steel/ duplex stainless steel / Inconel / other low alloy steels specified in Project.
This procedure covers the extent of parts to be tested, requirements, acceptance/rejection criteria and
documentation of PMI.
3 PURPOSE
The purpose of this procedure is to describe how Positive Material Identification (PMI) will be carried
out by Sub Contractor for the above addressed Project. PMI is to ensure that correct material is
supplied & installed at correct places as required by requisition, drawing and data sheet.
4 REFERENCES
ASME Sec II Part C, Ed. 2019: Welding Rods, Electrodes and Filler Metals
ASME Sec IX, Ed. 2019: Welding and Brazing Qualification
ASME Sec V, Ed. 2019: Non-Destructive Examination
ASME B 31.3, Ed. 2018: Processing Piping
ASTM E 353, Edition 2017: Chemical Analysis of Stainless, Heat Resisting, Managing and
Other Similar Chromium, Nickel – Iron Alloys
ASTM E 354, Edition 2017: Chemical Analysis of High-Temperature, Electrical, Magnetic and
Other Similar, Nickel and Cobalt Alloys
ASTM E327: Test Method for Optical Emission Spectrometric Analysis of
Stainless-Steel Type 18-8 Steels by the Point – to –Plane Technique
ASTM E352: Methods for Chemical Analysis of Tools Steels and other similar
Medium and high Alloy steels
ASTM E572: Test Method for X-ray Emission Spectrometric Analysis of
Stainless Steel
ASTM A-751, Edition 2017: Method Practices and Terminology for Chemical Analysis of Steel
Products.
ASTM E478 Edition 2017: Chemical analysis of Copper alloys
ASTM E62 Edition 2007: Chemical analysis of Copper & Copper alloys
DOCUMENT TITLE: Rev. 007
SITE POSITIVE MATERIAL
IDENTIFICATION TESTING Date:
PROCEDURE 26-Jul-2022
DOCUMENT NO.:
Page 5 of 14
MGP1-CP2-KMS-QA-6050-0003
API 578, Ed. 2018: Material Verification Program for New and Existing Alloy Piping
Systems
MGP1-CP2-PIL-QA-5733-1032: Inspection & Test Plan Site Fabrication, Erection & Testing of
Above Ground and Underground Piping
MGP1-CP2-PIL-QA-7739-0003: Specification for Welding
MGP1-CP2-PIL-MP-7739-0001: Purchase Specification for Piping Bulk Items
MGP1-CP2-PIL-QA-7739-0001: Specification for Positive Material Identification
6 PERSONAL
Personnel performing PMI testing shall have previous proven ability in PMI inspection. The
technicians shall have the following qualifications.
o Proof of successful completion of an acceptable PMI training course, this course could be
presented in- house the manufacturer or the other institution.
o Three months of documented experience performing PMI activity. PMI operator shall ensure
safe operation of the equipment.
PMI Operator shall ensure PMI equipment is operated, calibrated and maintained in accordance
with manufacturer’s specifications and the submitted and approved PMI procedure.
Records of PMI operator qualifications shall be maintained.
7 EQUIPMENT
Analyzed samples having relevance to the job shall be made available for Cross-reference and
calibration purposes.
The equipment shall require re-calibration at the job site, if there is a difference in the readings.
8 PROCEDURE
9 EXTENT OF EXAMINATION
PMI test location shall be marked with a semi- permanent paint marker. The marker shall not
contain additives such as aluminum, Sulphur, chloride, lead or zinc. For smaller items color coding
may be accepted.
Materials, welds that are found to be unacceptable during verification testing shall be marked
immediately with a circled red cross (X).
All verified material with an acceptable analysis shall be marked with the letter “AV”. The marking
shall be placed as follows:
o Welds: Adjacent to the welder’s mark on the weld
o Cut lengths of pipe from PMI-tested material are to have PMI markings transferred to all pieces
by Sub-Contractor.
All material shall comply with the requirements of the relevant material specification. Material
shall be verified to ensure the correct major alloying elements and correct percentage of each
element where applicable.
For Weld deposits, all recorded elements shall meet the weight percentage of alloy elements
specified in the relevant ASME II C specifications for deposited weld metal. Deposited weld metal
DOCUMENT TITLE: Rev. 007
SITE POSITIVE MATERIAL
IDENTIFICATION TESTING Date:
PROCEDURE 26-Jul-2022
DOCUMENT NO.:
Page 8 of 14
MGP1-CP2-KMS-QA-6050-0003
or undiluted weld metal deposit with consumables that match or nearly match the base metal
composition shall be the range allowed in ASME Sec IIC for each element.
Welds, material that are found to be unacceptable, shall be marked and separated pending
resolution by Sub- Contractor Quality Manager. Procedure shall be in place for handling of
Non- Conformance products.
If any of the major alloying elements are below the range specified by the applicable material
standard or a portable analyser indicates an incorrect match or “no match”, the component shall
be rejected.
Any deviation of alloying elements or absence of alloying elements with respect to the required
material specification more that 10% shall be considered as Rejected.
If any of the major alloying elements are greater than the range specified by the applicable
material standard, the alloy content must be reported to contractor for acceptance or rejection.
The Subcontractor shall identify, mark and remove all unacceptable materials.
Not conforming materials shall be immediately marked with water insoluble paint/ink, circled
red cross (x) as non-conforming materials and segregated from acceptable materials, to prevent
their unauthorized use.
Obtain a quantitative check analysis performed by an independent test laboratory using the
"referee" method referenced by the material specification. If no referee method is referenced, an
appropriate chemical analysis method specified in this procedure shall be used. Results of this
analysis shall govern.
If an item from a representative sample is rejected:
o 100% of the remaining components from which the sample was taken shall be examined;
o If no further components are rejected in above, the extent of examination shall return to the
originally specified.
If the test results of the independent laboratory tests are not within the acceptable range of the
ASME II C, ASTM or other applicable material specification, the material shall be rejected.
13 REPORTING
PMI Report having following information as minimum with attached PMI machine outputs.
Client Name
Company project No, Contract No, PO No
PMI Report No
Inspection date
Procedure No / Revision No
Item description
Technician Name / Signature
DOCUMENT TITLE: Rev. 007
SITE POSITIVE MATERIAL
IDENTIFICATION TESTING Date:
PROCEDURE 26-Jul-2022
DOCUMENT NO.:
Page 9 of 14
MGP1-CP2-KMS-QA-6050-0003
Calibration Details
Site / Location
Project.
PMI Instrument model
Line / Heat Number, Joint/ weld number
Element Percentage
Material specification and traceability
Name and signature of Operator
Name and signature of inspector to verify review and acceptance of result.
Acceptance / Rejection
15 ATTACHMENTS