SHIP YARD : 21ST CENTURY SHIPBUILDING CO., LTD
HULL NO : CSN-216
- TITLE . ANEMOMETER &INDICATOR -

c 1'I;111\T A T 1 c

r---- ,....-

·
"'
I I I I

-
D D

PLAN HISTORY TOTAL 11 SHEET WITH COVER


6
- 6 I--

6
E ~ 2006.12.01 FOR WORKING T.K.JANG Y.H.CHO Y.H.CHO E
~ 2005.06.28 FOR WORKING M.K.KIM Y.H.CHO S.K.SUNG
& 2005.01.03 FOR APPROVAL Y.H.CHO S.H.LEE S.K.SUNG
REV. DATE DESCRIPTION DWG. CHECK APP.
- r--
t§) HER IANA CO. ,LTO .
#688-1, JURE-DONG, SASANG-GU,
F SUSAN, KOREA 617-010 DATE 2006.12.07 F

Tel. (051) 313-6690-1 Fax. (051) 313-6693


DWG. NO. HA05-A19-A0011
...
· 1
I 2 3
I
1
I 2
I :5
I ...
- 3
NOTE
-
A
ANEMOMETER &ANEMOSCOPE A

- I--

B B

CONTENTS LIST
- PJT NO.: CSN-216 I--

WE IGTH
NO DWG' NO NAME OF COMPONENT Q'TY REMARKS
c APPROX. ACTUAL c
1 CONTENTS LIST
2 T-01601 BLOCK DIAGRAM

- 3 T-01101 WINO TRANSMITTER 1 8.0 Kg AT-200 f--

WIND SPEED/DIRECTION J.O


4 T- 01202 INDICATOR;
1 Kg AC-F11
D 5 T-01901 POWER SWITCH 1 0.1 Kg SW42 0

6 T-01902 DIMMER SWITCH 1 0.1 Kg DM-105


7 T-01211 DIGITAL TYPE INDICATOR 1 2.0 Kg AC-D10

- 8 T-01501 SIGNAL CONVERTER 1 2.0 Kg AC-S01 -


9 T-01203 DIRECTION DIAL NAME PLATE - -

E 10 T-01204 SPEED DIAL NAME PLATE - - E

11 T-01801 SPARE PART BOX 1 0.5 Kg


12

- SCALE /
TITLE:
APPROVED Y.H.CHO I--

COLOR 7.5 BG 7/2 INDEX TABLE CHECKED Y.H.CHO


I F DWG NO.
SHEET NO.
1
-

1
e» 2
HER lANA
3
DRAWN
DATE
T.K.JANG

2006.12.07
...
F

I I
t
2 3 4 5 e 7 a

A A

t WIND>

B B

MASTER SlOE
BR lOGE or CONTROL Rrod

c c

L-MPVC-9
OPVC-2.5
-----+- DC2<4V
YARD SUPPLY
,...-_ _......... TO. VDA
INMEA 0183)
B.C.C
~iWl
T1'fCS1Q

o I o
1 234 ~ 0 7 0

I
I
SIGNAL CONVERTER
L
I I

~
I
E E:

INDICATOR
(DIGITAl TYPE)
AC-otO
-cARGO CONTROL ADOV-

UNITS mm APPROVED Y.H.CHO


SCALE 1-:5 NIS BLOCK DIAGRAM CHECKED Y.H.CHO
, EDmON o tor ANEMOMETER DRAWN T.K.JANG r I

I
MODEL DAlE 2006.12.01
DWG No. 101601 HER lANA SHEET No. 2
2 4 5 e 7 a
1
I 2 3
I 4
... - .. - 5

A ABOUT 520 A

2 3

- ~

I
B .-- I
8

II

~
I

- I
I
4 ~

C C

S-_12HOlES

)t-.
~'. 9~=m~
, I ~
I I
.. BOW -t-- I -,
~ I---

~1~
,
I
--- "1-+../
0
I _160
I L , '1-
0

FITTING DIMENSION

- WEIGHT: 8.0Kg (IP 56) -


5 STAND JJ.. 1
4 TAiLAN FRP 1 9 NAME PLATE SUS304 1 MARKER
E E
:5 ROTATING JJ.. 1 8 CABlE GRAND BS 1 25a
2 GENERATOR 8.S 1 7 DlRECTlON PLATE SUS304 1 BOW
1 PROPElLER PC 1 6 lERMINAL COVER JJ.. 1
NO. NAME OF PART MAlERIAI. Q"TY REMARK NO NAME OF PART MATERIAL Q"TY REMARK

- UNITS mm
TITLE APPROVED Y.H.CHO -
SCALE A4 N/S WIND TRANSMITTER CHECKED Y.H.CHO

EDmON 0 (PROPELLER TYPE) DRAWN T.K.JANG


F F
MODEL AT-200 DATE 2006.12.07

DWG No T01101
@ HER lANA SHEET No 3
1 2 3 4
-
1
I 2 J
I 4
-
6
360 150
I
A
0


0
• •
0 - -
n1l
I A

-
~i~·
0

~
~----'-I HI
l
-
'~ci~
U
b ul ~

,,~ , mI l-tI .~ ·r ..,.


L, HI
I III

~:~.
-( 0
U "I
\; ::: N L--t ,I
e • •
• -- f------~ I I;
I i--f.
e

/ J I II

• •
D •
I II
IL _ _ _ _ .J•
II

....... •
;fc1~40
I
0 / 0 I 0
- -

C
05 cb 170
3

170
4

-4~ -4 ~

~
f---
11\ 0
0 N
N N

, , , ;

6-MS TAP
D 0

\ -t-
324
T

FITTING DIMENSION
- WEIGHT: 7.0 Kg
~

4 COVER STEEL 1
E E
3 NAHE PLATE SUS304 1
2 SPEED METER 1 Cl110 6 COAMING 1 30XSO
1 DIRECTION METER 1 Cl110 5 CASE STEEL 1
NO. NAME OF PART MATERIAL QiY REMARK NO. NAME OF PART MATERIAL Q"lY REMARK

- UNITS mm TITLE APPROVED Y.H.CHO -


SCALE A4 N/S WIND SPEED/DIRECTION INDICATOR CHECKED Y.H.CHO

EDITION 0 (COMBINATION FLUSH TYPE) DRAWN T.K.JANG


F F
MODEL AC-F11 DATE 2006.12.07

DWG No. T01202


Cq) HER lANA SHEET No. 4
1 2 3 4
1
I 2
I 3
I ... 7

A A

- ---
( ..... , ~

B
\ \
\ \
\ \
I 17.5
B

:-i
\ M12 x 0.75
\
..l1.l

t
~ r
13
"'
- l J.. A J"'LI l J.. A J

C
i 20.5 -- -
---
C

I~g 30
0
I 19
I
0
~

1 1 , ,
D D

ON
~12 HOLE
I 0 J 1/
- OFF
-
--E9- I
~

S/W NAME PLATE FITTING HOLE


E E

mLE
- UNITS mm APPROVED Y.H.CHO ~

SCALE A4 N/S POWER SWITCH CHECKED Y.H.CHO

EDITION 0 for ANEMOMETER DRAWN T.K.JANG


F F
MODEL SW42 DATE 2006.12.07

DWG No. T01901


(§J HER lANA SHEET No. S
2 3 ...
I
1
2 3 8

A ~---t/>42----I ABOUT 50 A

~18-

r n
-

B B

,....

- 1---- -- -- '--

'i.

c c

I
~YARD CONSOLE
~~3 HOLE

D
) 1//
12
,-~9 - -$ --
I
HOLE
D
[

-$
FITTING HOLE

E E

NO. NAME OF PART MATERIAl.. NAME OF PART MATERIAl..

TITLE
UNITS mm APPROVED Y.H.CHO

SCALE A4 N/S DIMMER SW ITCH ( 5W 10K Q ) CHECKED Y.H.CHO


EDITION 0 FOR ANEMOMETER DRAWN T.K.JANG
F F
MODEL DM105 DATE 2006.12.07
DWG No. T01902
(ij) HERIANA SHEET No. 6
1 2 3 ...
1
I 2
I :5
I . ....
I &
I e I 7
I I

206
A A
196

- ~
II II 3--r1 84
I 1
187
I
r
- ~
-
laaal~EJ
ISTBOJ
., SPEED
IPORT I laaal
DIRECTION
187 B

L
0 ....
30 00 t> 00 30
ot> BOW dO
- -
O~O
0
6;0 " <PANNEL CUTTING DIM.>
206 196
186
c c
90«) ANEMOMETER ()I> 90

U
0 0
0 0
JD
o~120
--- 120 0
O~
150 0 0 90 0
Q,0
150
.... -
0
180 o
B
NORMAL
D D
o S.FAULT
HERIANA
- :ot (0
- ~

~
WIND SPEED RANGE (DIGITAL 3 digit)
E E
Knot : 0 - 115 ....
M/H :
m/s : 0 - 60
WIND DIRECTION RANGE

- DIGITAl - PORT : 0 - 180


STBD : 181 - 359 UNITS mm Tm..E APPROVED Y.H.CHO -
ANALOG - PORT : 0- 180 M NIs Y.H.CHO,
ST8D : 0 - 180
SCALE INDICATOR(DIGITAL TYPE) CHECI<ED

F EDmON 0 DRAWN T.K.JANG' F


MODEl. AC-010 DATE 2008.12.Qi
owe No. T-01211
(8:) HER lANA SHEET No. 7 ~
1 I 2 I :5 I . I II I e I 7 I I
1 2 3 4 ...... _
lU
I I

A
300 A
252(fittingl

- "....
\
'\
\ ....
-

~. ~
II SIGNAL CONVERTER I
B B

~
152
. ~
(fitting)
200

~ I I
"....
- '\
\ ....
I \
\
-

c 3
dd ~ c

L
IJ
- ,...--

~
, , , 150 ,

0 r.7 0

'1. i

5
- -

4 LOCK SUS304 1
3 NAME PLATE PHENOL 1 MAKER E
E
2 NAME PLATE PHENOL 1 MAKER
1 CASE ASS 1 5 COAMMING 1 80x30
NO. tw.tE OF PART MATERIAl.. Q'lY REMARK NO. tw.tE OF PART MATERIAl.. Q'lY REMARK
TITLE:
- UNITS mm APPROVED Y.H.CHO r--

SCALE A4 N/S CHECKED Y.H.CHO


SIGNAL CONVERTER
EDITION 0 DRAWN T.K.JANG
F F
MODEL AC-S01 DATE 2006.12.07
DWG No. T01501 ~ HER lANA SHEET No. 8
1 2 3 4
2 ~._-- ....

A A

8 B

90 90

c c

180

o o

MATERIAL : ACRYL
GROUNDING: WHITE
PORT,30-150 : RED
E
STBD,30-150 : GREEN E
OTHERS: BLACK

NO. NAME OF PART MATERIAl.. NAME OF PART t.CATERIAI..

UNITS mm TITLE : APPROVED Y.H.CHO


SCALE A4 N/S CHECKED Y.H.CHO
DIRECTION DIAL NAME PLATE
EDITION 0 DRAWN T.K.JANG
F F
MODEL DATE 2006.12.07
DWG No. T01203
~ HER lANA SHEET No. 9
1 2 3 4
r--------'-------...&........-------------~-...Ilf 2
2 J

A A

B B

c c

Knot
m/s

o o

MATERIAL : ACRYl
GROUNDING: WHITE
Knot,O-115 : GREEN
E
OTHERS: BLACK E

NO. NAME OF PART MATERIAL NAME OF PART MATERIAL

UNITS mm TITLE: APPROVED Y.H.CHO


SCALE A4 N/S CHECKED Y.H.CHO
0
SPEED DIAL NAME PLATE T.K.JANG
EDITION DRAWN
F F
MODEL DATE 2006.12.07
DWG No. T01204
(E) HER lANA SHEET No. 10
1 2 3

1
I 2
I 3 .... ... - -, ... 13
PJT NO. SPARE PARTS LIST USE SETS PER
A
VESSEL A

CSN-216 ANEMOMETER 1

- ITEM
NAME OF PART OUT LINE
QUANTllY
REMARK
I---

NO.
PERVSL SPARE

B
1 FUSE ELEMENT D D 2 2 250V 1A
B
1-30-1

-
2
CB I---

3
c c

~
5
; ~ ;

0 6 0

- -
8

E E
9

10

11

F DWG NO. T01801 F

(E) HERIANA CO., LTD. SHEEr NO. 11


1
I 2 3
I ....
I
14

~ ., .'. ..
..

INSTRUCTION MANUAL
FOR
ANEMOMETER & ANEMOSCOPE

HERIANA CO.,LTD
PUSAN ,KOREA
TEL: (82) 051-313-6690
FAX: (82) 051-313-6693
15

- Table of contents -

1. General Description

2. Composition

3. Performance Characteristics
3.1 Transmitter for wind direction and speed
3.2 Indicator for wind direction and speed

4. Principle of operatlon, and basic circuitry

5. Construction of component apparatus


t 5.1 Transmitter lor wind direction; and speed
5.2 Indicator for wind direction and speed

6. Maintenance
6.1 Transmitter for wind direction and speed
6.2 Indicator for wind direction and speed

7. Dismounting Procedure

8. Troubleshooting

i'
16

1. General Description
This equipment provides, wind' direc~tion and speed signals
stmutteneousfv from a:'signal transmitter for the remote
, . ".it·

indication observation'

2. Composition
Each set of this equipment consists of the;
(1) Transmitter for wind direction and speed
(2) Indicator for wind direction and speed
(3) Spare parts box

3. Pertermance characteristics

3.1 Transmitter for wind direction and speed


Type Propeller type
1 Starlof wind dlrection axis
Wind speed more than 1nYs at 90"
Wind direction . Synchro motor type
AC 110V 150Hz or 60Hz
Wind speed·
starting wind speed : more than 1nYs
Maximum permissible wind speed ; 6011}'s

3.2 Indicator for wind direction and speed


Wind direction Synchro motor receiver 360
0

AC 110V 50llz or 60Hz


Wind speed Moving-coil Voltmeter--method
1rr{s to 60rr{s
i?
J.,

4. Principle of operation and circuitry


Transmitter for wind direction and speed
The wind direction is detected as a rotating angle of the vertical tail-fin
and the bodY with respect to the stationary part, transmitter to the
synchro motor type transmitter, and read from the rotating angle of the
synchro motor the receive.
The wind speed is converted to a voltage by the generator added
converter which is directly coupled to the propeller and the voltage is
rectified and directly read on the voltmeter which is calibrated in
instantaneous wind speed.
The basic diagram Is as shown in the FIG-1 the wind direction system
and the wind sped system are Independent each other.

I
GEl\JERATOR I
, , ,
SYNCHRO MOTOR
TRANSMITTER

I SLIP LING I
6 7 8 4 5 I

f------
\
i 1 2 3 I

I
, I P.T I

I I P.C.B i ,
I WIND DIRECTION INDICATOR I
I WIND SPEED INDICATOI( (VOLTMETER) -----lI
TRANSFORMER BOX
. "",-'
(

AC POWER SUPPLY t'

FIG-l
18
~,

5. Construction of component apparatus


'f •.. -,.. ,

5.1 Wind direction and- speed transmitter


" ./"

The wind direction and speed transmitter has the construction


as shown in fig-2 the propeller is fixed to the generator shaft
In sush a manner that the' propeller shaft is the generator shaft.
The generator is located in front part of the streamline body~
the generator cover can be easily mounted or removed by hand
with propeller removed.
The wind direction transmitter is fixed to the lower stand.
To the central stand is mounted on ball bearings a shaft Which
supports the streamline body.
The wind direction and the shaft are connected with each other
by means of a coupling for the installation if this equipment
select a ,location which is as high as practicable and is not
affected by obstructions. In case of the ground installation,
angle I'NII .mark on the stand to the north and "S"mark to the
south and secure equipment. firmly with 5 m10 bolt. In 08Se of
the ahlpboard Instatlatlcn, angle II bow" mark to the head of the
ship.
Note that if this precaution Isnot observed, Indicator reding are
erroneous.
The electric wires should be inserted from the cable grand and,
with the terminal cover removed , be connected to the proper
terminal With reference terminal nos.
The stand has a ground terminal be sure to the connect this
terminal to ground.
19

5.2 Wind direction and speed indicator


The wind direction scale has .3.6.g-:aduations at evenly spaced
intervales in the outer area to indicated 36 directions.
The wind speed ecale '" is a wide angle double scafe(full angle
2500
)of 0 to 60nis and 0 to 115knot ranges.
The illumination intensity, adjustments is propeller with the
illumination intensity adjusting variable resistor.
By removing connections, the instrument can, be easily removed.

6. Maintenance

6.1 Wind direction and speed transmitter


t Bearing

All bearing used ball type, these bearings are thoroughly


cleaned and then packed with grease and the oil reservoir filled
with oil, and should require no maintenance.
oarelessoJ)ening of the bearing will cause a trouble.
* Tranamttter painting,etc.
W~en p~inting this apparatus, pay special attention to the
instructions giVen in theFIG-2.

Slight propeller contamination is not objectionable.


If the propeller is badly contamination, polish with abrasives
or the link and then clean with gasoline. To do this , the pro-
peller, be SUre to align the key In position. If the key is not in
position, in may drop during rotating.

FIG-2
20

6.2 wind direction and speed indicator


To make the zero adlustment .ot.the wind speed indicator,
remove the cover and adjust the inside mounted zero adjusting
If

screw. The Htumlnatton lamp and 'the fuse can be replaced also
by removing the cover.
The wind direction and sneed scale plates are adjusted and
should not be tampered with unless absolutely needed.

7. Dismounting procedure "-


The dismounting of propeller and generator is .made thorough the
following procedure in case where checking of generator,is
necessary;
1) Unscrew the propeller stopper (A)
2) Unscrew the propeller (B) off
3} Unscrew the generator cover (C)
4) UnsCrew the generator fixing screw (D) and take the generator
off.

IREMARK : Wilen mounting lhe propeller on the. shaft. carre must;


be taken to always put the shaft key in the key grove of
the propeller.

l0
(B)~ _ .
i r: (Cl t<wer
. 1,..--'"
t
! ,-I/
I
(OJ
'
RaWm., 6ot,

r.......

Taken off the generator cover, turn it to the right until the red mark
coincides with the blue mark of the generator and pull forward.
21

8. Troubleshooting

f---Trouble symptom f---_p_r_o_b_a_b_'e_c_a_u~- Corrective measure


1. power switch istlii11edT 1.Turn on the power sWitch.
off. I
I
!
2. power is not available
!
I
2. Check the external power
at power ! source.

I
3. power is available at 13. Check the fuse of the
Wind direction part power terminal, but I indicator. Check the cable
does not operate. except terminals N04 I between the transmitter and
and 5 at transmitter. the indicator for open. If the
::i., cable Is normal,check for
:
continuity between trans-
I mittel' terminals 4 and 5 if
I wire broken,1t Is necessary
to repair the synchromotor
transmitter.

1 ;
1. Dl$connect· the transmitter or
I receiver at terrnlnals 6.7 and
1. Secondary voltage of I 8. Apply ac110V ,60 Hz at te-
the transmitter or !:i rminals 4 and 5 of the trans-
receive is abnormal. mitter.
ll
Connect a circuit tester
between 6 and 7,7and 8,8 and
6 and turn the body lightly.
Indicator In abnormal I If a secondary voltage of
maximum 97V in the case of
transmitter or about 90V in
•i the case of the receiver
appears.
I The synchro motor is normal
or if this voltage does not a-
ppear, the synchro motor Is
I
.I -defective and recutres repair.
---------------- - - - - - - - - - - - - - - - - _ . _ - - _ . _.._.._.
22

1. Connecting cable is
defective.
1. Check the cable between
the transmitter and the
Indicator for open.
l
2. Contact is poor 2. Dismount front cover of the
available at power transmitter and check the
terminal contact between the slip-
ring and brushes.

3. Propeller does not 3. Ball bearing of the generator


rotating is defetive and requires
repair.

4~ Wind speed generator 4. Connect a circuit tester (of


is defective. the range of AC 10V or so)
Indicating part
between terminate, and1.~
.does not, oJ)erate
snd3 of the transmitter, and
rotatinp the propeller lightly. 1

11 a voltage of 3 to 4V sppe-
ars, the generator is normal
or If this voltage does not
appear. the generator Inter-
nal wiring is open, and
requires replacement or
repair.

5. Wind speed indicator 5. Check continuity between


is "defective. terminal 19 and 20 of the
indicator if there is no
continuity, the meter is
defective and requires
.......l .
repair•
• MANUFACTUR:E ITEM.
• ANEMOMETER
• RUDDER ANGLE INDICATOR
• ENGINE TELEGRAPH
• PROPELLER SHAFT R.P.M INDICATOR
• TEMPERATURE SENSOR
• CONVERTER MODULE
• THERMOMETER

ADDRESS: #688-1 JURE1-DONG,SASANG-KU,


SUSAN,KOREA
TEL: +82-51-313-6690
FAX: +82-51-313-6693
E-mail: iheriana@hanmail.net
Homepage: http://www.heriana.co.kr