1. The RO plant board panel is broken and waiting for a spare part.
2. The LFO forwarding pump A is broken during a heat run test and waiting for materials to be normalized during a planned outage.
3. The U4 HP FW HTR has a sensor deviation and hunting issue and will be replaced during a planned outage, currently waiting on a PR.
4. The U3 dual flow band SC blow valve cannot open or close and is waiting on materials and a PR from planning.
Original Description:
Original Title
Share Important Information 2nd week of may 2020 (8 may 2020)
1. The RO plant board panel is broken and waiting for a spare part.
2. The LFO forwarding pump A is broken during a heat run test and waiting for materials to be normalized during a planned outage.
3. The U4 HP FW HTR has a sensor deviation and hunting issue and will be replaced during a planned outage, currently waiting on a PR.
4. The U3 dual flow band SC blow valve cannot open or close and is waiting on materials and a PR from planning.
1. The RO plant board panel is broken and waiting for a spare part.
2. The LFO forwarding pump A is broken during a heat run test and waiting for materials to be normalized during a planned outage.
3. The U4 HP FW HTR has a sensor deviation and hunting issue and will be replaced during a planned outage, currently waiting on a PR.
4. The U3 dual flow band SC blow valve cannot open or close and is waiting on materials and a PR from planning.
1. RO Plant B Board Panel Broken Waiting Spare part 2. LFO Forwarding Pump A Pump A broken when heat run test during U3 Waiting material (will be normalize on U4 PO PO) 3. U4 HP FW HTR 7 LVL -Deviation between sensor A and B, can’t put Will be replace during U4 PO. Currently to average. waiting PR from PLN -Hunting during storm 4. U3 Dual Flow Band SC A Can’t open and close Waiting material, waiting PR from PLN Blow Valve 5. U3 Long Retractable SB Bending Waiting material 5-L 6. U3 Turbine Zero speed Module abnormal Waiting material (31 march 2020) 7. U3 Screen wash pump A the pump is running but no discharge pressure Repaired pump in warehouse (will be carried out during outage work) 8. U3 Economizer Outlet can’t read actual value In progress repair flue gas oxygen right (B2) 9. U4 IDF A & B Outlet flue there is big deviation between IDF A & B Outlet Investigation gas pressure flue gas pressure 10. Sootblower U4 PLC blurred condition Waiting material monitor 11. U4 Control Valve 1 CONTROL VALVE NO.1 position at dcs different investigation with control valve 2 and control valve 3 12. Sea Water Feed Pump A Vibration Waiting spare part 13. U4 EHC Oil Pump B Get low pressure alarm investigation 14. U4 Generator Frequency U4 gen Freq (4GEN -HSIG 093) abnormal Need calibration (50.21HZ),indication Frequency bias < L ALARM