You are on page 1of 12

For Review C 9/22/2022 AT

For Review B 7/5/2022 AT RW MMcN

REASON FOR ISSUE REVISION REV. DATE PREP. BY CHECKED APPROVED

Document Class: No. of pages:

D-LIST 12
Doc. Type:
Project: Barossa FPSO
LA - Lists, registers and indexes
Discipline:
Unit: BWO Opal
P - Process
System no:
IMO No:
00
Client: Santos NA Barossa Pty Ltd
Document Title:

PIPING LINE LIST

Alt Doc. No:


E-21061-VD-PR-0744 / TH-22099-M-LA-0001
Client Doc No.: Doc. No.: Rev.

BAF-210 2803 4477-SIM-L-LA-00005 B

Page 1
Barossa FPSO
Doc. No: 4477-BWO-P-LA-00008 - PIPING LINE LIST - ENGINEERING REGISTER (IMPORT FILE TEMPLATE Rev.: 02

Revision History

Revision Section Paragraph Description of changes

Whole
C Updated according to PID development
Doc

Page 2
© BW Offshore 2021

Page 3
Note Field Name Field Description Required by

Line Tag in accordance with the Technical Coding manual


1 Line No (4477-BWO-Z-SA-00002) and sequence number allocation. Completed when Line tag is
Note: Vendor tag (where applicable) shall be entered under created.
Foreign Line No (Note 30).

2 Service / Description Description of equipment service e.g. SEAWATER/COOLING Completed when Line tag is
MEDIUM HEAT EXCHANGER B HOT SIDE INLET. created.

Completed when Line tag is


3 Tag. Reg. Drop down list - PIPE. created.

4 Project BWO Project Number. Completed when Line tag is


created.

Completed when line tag is


5 Comment Any specific comments related to the line, if applicable. created.

All BWO PID Drawing document nos (Doc Type - XB) related to
the tag. These document nos shall be as in the SMDL/ MDL
Completed when equipment
PID Drawing and will be linked to the Tag from BWO document tag is created.
6(a) No management system profile.
Multiple document nos shall be separated with COPYRIGHT
SYMBOL ©

All BWO Isometric Drawing document nos (Doc Type - XN)


related to the tag. These document nos shall be as in the Completed when equipment
Isometric SMDL/ MDL and will be linked to the Tag from BWO document tag is created.
6(b) management system profile.
Drawing No
Multiple document nos shall be separated with COPYRIGHT
SYMBOL ©

All Other BWO Drawing document nos (Doc type that does not
belong to XB / XN / DS / VB) related to the tag. These
Completed when line tag is
BWO DRW. Other Drawing document nos shall be as in the SMDL/ MDL and will be linked created.
6(c) Reference No to the Tag from BWO document management system profile.
Multiple document nos shall be separated with COPYRIGHT
SYMBOL ©

All BWO Datasheet document nos (Doc Type - DS) related to


the tag. These document nos shall be as in the SMDL/ MDL Completed when line tag is
and will be linked to the Tag from BWO document
6(d) Datasheet management system profile. created.

Multiple document nos shall be separated with COPYRIGHT


SYMBOL ©

All BWO Certificates document nos (Doc Type - VB) related to


the tag. These document nos shall be as in the SMDL/ MDL
and will be linked to the Tag from BWO document
6(e) Certificate management system profile. Completed before start of
DOC. No construction.
Multiple document nos shall be separated with COPYRIGHT
SYMBOL ©

Page 4
7 Discipline Drop down list - L (Piping/Layout); M (Mechanical) Completed when line tag is
created.

8 System System Code in accordance with the Technical Coding manual Completed when line tag is
(4477-BWO-Z-SA-00002) e.g. "57" created.

Drop down list - It is not possible to modify the Line No. once it
has been imported into the Engineering Database.
If there is a change to the Line No. that has already been Complete immediately when
9 Status imported into the Engineering Database, then the Line No. change is known.
must be Voided and new Line No created. Enter VOIDED in this
field for the existing/ old Line No.

Completed when line tag is


10 To Line No Flow Downstream of the line tag created.

Completed when line tag is


11 From Line No Flow Upstream of the line tag created.

Shall be completed when PO is


12 Package No BWO Procurement Package No. issued for the
Supply/Fabrication of the line.

Shall be completed when PO is


13 Supplier Supplier/ Fabricator of the line (not the manufacturer). issued for the
Supply/Fabrication of the line.

Shall be completed when PO is


14 Sparing % Line configuration with respect to redundancy. issued for the
Supply/Fabrication of the line.

Shall be completed when PO is


15 P.O. No BWO Purchase Order No. issued for the
Supply/Fabrication of the line.

Completed when line tag is


16 Line Size Nominal Pipe Size created.

17 Service Code (as per 4477) Drop down list - Service Code in accordance with the Technical Completed when line tag is
Coding manual (4477-BWO-Z-SA-00002) Eg. "DC" created.

Drop down list - Insulation Class shall be defined from line tag
18 Insulation (as per 4477) in accordance with the Technical Coding manual (4477-BWO- Completed when line tag is
Z-SA-00002). created.

Drop down list - Pipe Class stands for Piping Material Completed when line tag is
19 Pipe Class (as per 4477) Specification. Shall be in accordance with the Marine/ Topside created.
Piping Valve Specification.

Completed when line tag is


20 Piping Class Drop down list - Piping Class as per DNVGL-OS-D101 created.

Page 5
21 Coating Coating shall be in accordance with the Project Painting Completed when line tag is
Specification created.

22 Oper. Pressure Line tag operating pressure in BARG Completed when line tag is
(Min/Max/Normal where applicable) created.

Line tag design pressure in BARG Completed when line tag is


23 Design Pressure (Min/Max/Normal where applicable) created.

24 Test Pressure Line tag hydrotest pressure in BARG 1.5xDesign Pressure Completed when line tag is
created.

25 Oper. Temperature Line tag operating temperature in oC Completed when line tag is
(Min/Max/Normal where applicable) created.

26 Design Temperature Line tag design temperature in oC Completed when line tag is
(Min/Max/Normal where applicable) created.

27 Standard Velocity (m/s) Line tag fluid flow at standard velocity in m/s Completed when line tag is
created.

Completed when line tag is


28 Calculated Velocity (m/s) Line tag fluid flow at calculated velocity in m/s created.

29 Replaced Line No If a tag is replaced with a new one, the old tag shall be entered Shall always be completed
here (Cross reference with Note 9). when a tag is changed

30 Foreign Line No If dual tagging / vendor tag is required, the secondary tag to Completed when line tag is
be included here. created.

31 Modified By Initials of person creating / updating the Piping Line List. Entered for every change.

32 Modified Date Date when line tag was created / updated. Entered for every change.
(Date Format: DD/MM/YYYY)

Project specific code number which identifies reponsibility for


33 Site Code supplying and installing the equipment, e.g. Integration Completed before start of
Shipyard or Topside Module Fabrication Yard. Code shall be construction.
assigned by BWO

Populate the applicable DCN Number(s) (e.g. DCN 850) to Completed when design is
34 DCN Number which the Line No is affected. changed.

Page 6
Complete during Execute
Combined thermal and To identify lines requiring combined thermal and acoustic unless requirements are
35 acoustic insulation insulation. clearly known and identified
earlier.

To identify lines requiring flushing and drying prior to service Complete during Execute
life operation or after hydrotest. unless requirements are
36 Flushing and Drying Note: All lines shall be flushed to internally remove clearly known and identified
debris/dam prior to hydro test. earlier.

Complete during Execute


unless requirements are
37 Flushing Medium To identify Flushing Medium clearly known and identified
earlier.

Complete during Execute


38 Flushing Required Cleaniness To identify flushing required cleaniness unless requirements are
clearly known and identified
earlier.

Complete during Execute


To identify lines requiring chemical cleaning prior to service unless requirements are
39 Chemical Cleaning life operation. clearly known and identified
earlier.

Complete during Execute


40 Internal Pickling and To identify lines requiring internal pickling and passivation unless requirements are
Passivation prior to service life operation. clearly known and identified
earlier.

Complete during Execute


To identify lines requiring hot oil flushing prior to service life unless requirements are
41 Hot Oil Flushing operation. clearly known and identified
earlier.

Complete during Execute


42 External Pickling and To identify lines requiring external pickling and passivation unless requirements are
Passivation prior to service life operation. clearly known and identified
earlier.

Complete during Execute


43 Fluid State To identify fluid state in line either as "Single Phase Gas", unless requirements are
"Single Phase Liquid" or "Multiphase". clearly known and identified
earlier.

To identify fluid handled under normal operation in line based Complete during Execute
44 Fluids on service such as "Hydrocarbon Gas", "Hydrocarbon Liquid", unless requirements are
clearly known and identified
"Utility Service", "Multiphase Hydrocarbon", etc earlier.

45 Flange Management Criticality Refer "Flange Management Plan - 4477-BWO-Z-TA-00004" for Completed before start of
Flange Criticality rating construction.

Page 7
Complete during Execute
Heat Tracing Temperature (deg unless requirements are
46 Line Heat Tracing temperature in oC
C) clearly known and identified
earlier.

Complete during Execute


47 Critical Line Identification Line Critical (YES/NO) unless requirements are
clearly known and identified
earlier.

48 Fluid Density (kg/m3) Line Fluid Density in kg/m3 Completed when line tag is
created.

Completed when line tag is


49 Flow Momentum (kg/sm2) Flow Momentum in kg/sm2 created.

Complete during Execute


50 AIV Assessment To identify AIV applicability unless requirements are
clearly known and identified
earlier.

51 END Syntax stop read. Leave blank.

Page 8
Note 1 Note 2 Note 3 Note 4 Note 5 Note 6(a) Note 6(b) Note 6(c) Note 6(d) Note 6(e) Note 7 Note 8 Note 9 Note 10 Note 11 Note 12 Note 13 Note 14 Note 15 Note 16 Note 17 Note 18 Note 19 Note 20 Note 21 Note 22 Note 23 Note 24 Note 25 Note 26 Note 27 Note 28 Note 29 Note 30 Note 31 Note 32 Note 33 Note 34 Note 35 Note 36 Note 37 Note 38 Note 39 Note 40 Note 41 Note 42 Note 43 Note 44 Note 45 Note 46 Note 47 Note 48 Note 49 Note 50 Note 51
1.5x designP
BWO DRW. Reference Combined Thermal Flushing Flange Heat Tracing Flow
Service Code Insulation (as Pipe Class (as Oper. Design Standard Calculated Flushing and Flushing Chemical Internal Pickling External Pickling Critical Line Fluid Density
Line No Service / Description Tag. Reg. Project Comment Discipline System Status To Line No From Line No Package No Supplier Sparing % P.O. No Line Size (as per 4477) per 4477) per 4477) Piping Class Coating Oper. Pressure Design Pressure Test Pressure Temperature Temperature Velocity (m/s) Velocity (m/s) Replaced Line No Foreign Line No Modified By Modified Date Site Code DCN Number and Acoustic Drying Medium Required Cleaning and Passivation Hot Oil Flushing and Passivation Fluid State Fluids Management Temperature Identification (kg/m3) Momentum AIV Assessment END
PID Drawing No Isometric Drawing No Other Drawing No Datasheet Certificate DOC. No Insulation Cleaniness Criticality (deg C) (kg/sm2)

Demin System (53)

5 micron
Freshwater supply to Demin Package Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE TP-M92021 E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3001-AS20U-0N available during construction 1-1/2"-WD-53-3002-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Filter 53-CB-3401A Inlet Branch Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3001A E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3002-AS20U-0N available during construction 1-1/2"-WD-53-3001-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Filter 53-CB-3401B Inlet Branch Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3001B E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3003-AS20U-0N available during construction 1-1/2"-WD-53-3001-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Brine Recycle to RO HP pump Suction Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 0.4 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3004-AS20U-0N available during construction 1-1/2"-WD-53-3005-AS20U-0N 1"-WD-53-3022-BS20-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Common RO HP pump feed Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3006-AS20U-0N 53-CB-3001A E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3005-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-PA-3403A Feed branch Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3008-BS20-0N 1-1/2"-WD-53-3005-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3006-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3007-AS20U-0N 53-PA-3403B Feed branch Pipe 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 1-1/2"-WD-53-3009-BS20-0N 1-1/2"-WD-53-3005-AS20U-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N AS20U APPLICABLE Bergesen Green 6 10 15 35 90 APPLICABLE 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3008-BS20-0N 53-PA-3403A 300# Branch Pipe 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 53-PA-3003A 1-1/2"-WD-53-3006-AS20U-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N BS20 APPLICABLE Bergesen Green 14.6 20 30 35 90 APPLICABLE 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3009-BS20-0N 53-PA-3403B 300# Branch Pipe 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 53-PA-3003B 1-1/2"-WD-53-3007-AS20U-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N BS20 APPLICABLE Bergesen Green 14.6 20 30 35 90 APPLICABLE 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3010-BS20-0N RO HP Feed Supply Manifold Pipe 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 1-1/2"-WD-53-3013-BS20-0N 1-1/2"-WD-53-3062-BS20-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N BS20 APPLICABLE Bergesen Green 14.6 20 30 35 90 APPLICABLE 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 16 - NOT filtered fresh
1"-AI-53-3011-AC21-0N Critical Air supply Pipe 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 3/4"-AI-53-3094-AS20U-0N TP-M920X1 0345 Techouse APPLICABLE 170864 1" AI 0N AC21 APPLICABLE Bergesen Green 6 20 30 35 90 APPLICABLE 0.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Gas Instrument Air Low NOT APPLICABLE NO 1.225 NOT APPLICABLE NO
ppm Chloride

5 micron
Non-Critical Air supply Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 3/4"-AI-53-3095-AS20U-0N TP-M920X2 E4477-MC-DG- Techouse NOT 170864 1" AI 0N AC21 NOT System 16 - 6 20 30 35 90 NOT 1.1 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas Instrument Air Low NOT APPLICABLE NO 1.225 NOT APPLICABLE NO
1"-AI-53-3012-AC21-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 1 HP Feed Supply Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3006A 1-1/2"-WD-53-3010-BS20-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N BS20 NOT System 19 - 14.6 20 30 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3013-BS20-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 2 HP Feed Supply Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3006B 1-1/2"-WD-53-3010-BS20-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N BS20 NOT System 19 - 14.6 20 30 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3014-BS20-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 1 Brine Discharge Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3021-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N BS20 NOT System 19 - 14.6 20 30 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3015-BS20-0N available during construction 53-CB-3006A (N3) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 2 Brine Discharge Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3021-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N BS20 NOT System 19 - 14.6 20 30 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3016-BS20-0N available during construction 53-CB-3006B (N2) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 1 Permeate Outlet Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3007 (N6) E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3017-AS20U-0N available during construction 53-CB-3006A (N2) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 2 Permeate Outlet Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3007 (N5) E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3018-AS20U-0N available during construction 53-CB-3006B (N3) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 1 Permeate Dump Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3017-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3019-AS20U-0N available during construction 1-1/2"-DW-53-3051-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
RO Train 2 Permeate Dump Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3018-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3020-AS20U-0N available during construction 1-1/2"-DW-53-3051-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Brine Bleed to drain Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3022-BS20-0N E4477-MC-DG- Techouse NOT 170864 1" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1"-WD-53-3021-AS20U-0N available during construction 1-1/2"-DW-53-3051-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Brine recycle to RO HP Pumps Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3004-AS20U-0N 1-1/2"-WD-53-3015-BS20-0N E4477-MC-DG- Techouse NOT 170864 1" WD 0N BS20 NOT System 19 - 3.5 10 15 35 90 NOT 0.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1"-WD-53-3022-BS20-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Permeate Tank Overflow Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3007 (N3) E4477-MC-DG- Techouse NOT 170864 2" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
2"-DW-53-3023-AS20U-0N available during construction 2"-DW-53-3076-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Permeate Tank Drain Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3007 (N2) E4477-MC-DG- Techouse NOT 170864 2" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
2"-DW-53-3024-AS20U-0N available during construction 2"-DW-53-3023-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Feed Pump Suction Manifold Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3027-AS20U-0N 53-TB-3007 (N1) E4477-MC-DG- Techouse NOT 170864 2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
2"-WD-53-3025-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Feed Pump 53-PA-3008A Suction Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PA-3008A E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3026-AS20U-0N available during construction 2"-WD-53-3025-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Feed Pump 53-PA-3008B Suction Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PA-3008B 2"-WD-53-3025-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3027-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Feed Pump 53-PA-3008A Discharge Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3030-AS20U-0N 53-PA-3008A E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3028-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Feed Pump 53-PA-3008B Discharge Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3030-AS20U-0N 53-PA-3008B E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3029-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3030-AS20U-0N EDI / UV Feed Manifold Pipe 4477 4477-SIM-P-XB-55163.002 available N/A N/A during construction L 53 ACTIVE 1-1/2"-WD-53-3031-AS20U-0N 1-1/2"-WD-53-3028-AS20U-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N AS20U APPLICABLE Bergesen Green 5.25 10 15 35 90 APPLICABLE 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3031-AS20U-0N UV Chamber 53-VF-3009A feed Pipe 4477 4477-SIM-P-XB-55163.003 available N/A N/A during construction L 53 ACTIVE 53-VF-3009A (N1) 1-1/2"-WD-53-3030-AS20U-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N AS20U APPLICABLE Bergesen Green 5.25 10 15 35 90 APPLICABLE 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3032-AS20U-0N UV Chamber 53-VF-3009B feed Pipe 4477 4477-SIM-P-XB-55163.003 available N/A N/A during construction L 53 ACTIVE 53-VF-3009B (N1) 1-1/2"-WD-53-3030-AS20U-0N 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N AS20U APPLICABLE Bergesen Green 5.25 10 15 35 90 APPLICABLE 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
1 -1/2"-WD-53-3033-AS20U- TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
UV Chamber 53-VF-3009A Outlet Pipe 4477 4477-SIM-P-XB-55163.003 available N/A N/A during construction L 53 ACTIVE 1-1/2"-WD-53-3036-AS20U-0N 53-VF-3009A (N2) 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N AS20U APPLICABLE Bergesen Green 5.25 10 15 35 90 APPLICABLE 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
0N
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1-1/2"-WD-53-3034-AS20U-0N UV Chamber 53-VF-3009B Outlet Pipe 4477 4477-SIM-P-XB-55163.003 available N/A N/A during construction L 53 ACTIVE 1-1/2"-WD-53-3039-AS20U-0N 53-VF-3009B (N2) 0345 Techouse APPLICABLE 170864 1-1/2" WD 0N AS20U APPLICABLE Bergesen Green 5.25 10 15 35 90 APPLICABLE 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
UV Chamber Bypass Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3036-AS20U-0N 1-1/2"-WD-53-3031-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3035-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Feed Supply Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3033-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3036-AS20U-0N available during construction 53-CB-3010A (N2A) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Permeate Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3037-AS20U-0N available during construction 53-CB-3010A (N4A) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Permeate to drain Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3037-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3038-AS20U-0N available during construction 2"-DW-53-3050-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010B Feed Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3033-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.3 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3039-AS20U-0N available during construction 53-CB-3010B (N2B) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI53-CB-3010 B Permeate Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3040-AS20U-0N available during construction 53-CB-3010B (N4B) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010 B Permeate to drain Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3040-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3041-AS20U-0N available during construction 2"-DW-53-3050-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Common Permeate Manifold Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3045-AS20U-0N 1-1/2"-WD-53-3037-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3042-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Permeate Recycle to RO Permeate Tank Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3007 (N9) 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3043-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Permeate Dump Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3044-AS20U-0N available during construction 2"-DW-53-3050-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Permeate to Demin Tank Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE TP-M-92148 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 5.25 10 15 35 90 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3045-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-CB-3001A Filter Drain Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-DW-53-3050-AS20U-0 53-CB-3001A E4477-MC-DG- Techouse NOT 170864 3/4" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 1.0 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-DW-53-3046-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-CB-3002A Filter Drain Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-DW-53-3050-AS20U-0 53-CB-3002A E4477-MC-DG- Techouse NOT 170864 3/4" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 1.0 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-DW-53-3047-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-CB-3001B Filter Drain Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-DW-53-3050-AS20U-0 53-CB-3001B E4477-MC-DG- Techouse NOT 170864 3/4" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 1.0 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-DW-53-3048-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-CB-3002B Filter Drain Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-DW-53-3050-AS20U-0 53-CB-3002B E4477-MC-DG- Techouse NOT 170864 3/4" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 1.0 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-DW-53-3049-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Drain Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Drip Tray 1/2"-WD-53-3007-DX-T-0 E4477-MC-DG- Techouse NOT 170864 2" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
2"-DW-53-3050-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Brine Drain Pipe 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE TP-M-92061 1"-WD-53-3021-AS20U-0 E4477-MC-DG- Techouse NOT 170864 1-1/2" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-DW-53-3051-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP EDI Concentrate Return Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE SP-3008 E4477-MC-DG- Techouse NOT 170864 1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 12/8/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-CZ-53-3052-AS20U-0N available during construction 1-1/2"-CZ-53-3060-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1/2"-CZ-53-3053-AS20U-0N CIP EDI Electrolyte Return Pipe 4477 4477-SIM-P-XB-55163.004 available N/A N/A during construction L 53 ACTIVE 1-1/2"-CZ-53-3060-AS20U-0N SP-3007 0345 Techouse APPLICABLE 170864 1/2" CZ 0N AS20U APPLICABLE Bergesen Green 4 10 15 40 50 APPLICABLE 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 12/8/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

Page 9
BWO DRW. Reference Combined Thermal Flushing Flange Heat Tracing Flow
Service Code Insulation (as Pipe Class (as Oper. Design Standard Calculated Flushing and Flushing Chemical Internal Pickling External Pickling Critical Line Fluid Density
Line No Service / Description Tag. Reg. Project Comment Discipline System Status To Line No From Line No Package No Supplier Sparing % P.O. No Line Size (as per 4477) per 4477) per 4477) Piping Class Coating Oper. Pressure Design Pressure Test Pressure Temperature Temperature Velocity (m/s) Velocity (m/s) Replaced Line No Foreign Line No Modified By Modified Date Site Code DCN Number and Acoustic Drying Medium Required Cleaning and Passivation Hot Oil Flushing and Passivation Fluid State Fluids Management Temperature Identification (kg/m3) Momentum AIV Assessment END
PID Drawing No Isometric Drawing No Other Drawing No Datasheet Certificate DOC. No Insulation Cleaniness Criticality (deg C) (kg/sm2)

5 micron
EDI Cabinet Drain Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 3/4"-DW-53-3099-AS20U-0N 53-IB-3010 Drain E4477-MC-DG- Techouse NOT 170864 3/4" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 12/8/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-DW-53-3054-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
EDI Electrolyte drain Vent Pipe 4477 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Vent 3/4"-DW-53-3099-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" DW 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 12/8/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-DW-53-3055-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP PUMP 53-PA-3012 SUCTION Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PA-3012 53-TA-3011 (N1) E4477-MC-DG- Techouse NOT 170864 1-1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1 -1/2"-CZ-53-3056-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP PUMP 53-PA-3012 DISCHARGE Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3013 53-PA-3012 E4477-MC-DG- Techouse NOT 170864 1-1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-CZ-53-3057-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP recirculation Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TA-3011 (N2) 1-1/2"-CZ-53-3057-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1-1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-CZ-53-3058-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP forwarding (RO / EDI Dilute) Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE SP-3010 53-CB-3013 E4477-MC-DG- Techouse NOT 170864 1-1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-CZ-53-3059-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP Return Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE SP-3009 E4477-MC-DG- Techouse NOT 170864 1-1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 1.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-CZ-53-3060-AS20U-0N available during construction 53-TA-3011 (N3) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP Tank Overflow Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Bund E4477-MC-DG- Techouse NOT 170864 1-1/2" CZ 0N AS20U NOT System 19 - Atm 10 15 40 50 NOT 1.2 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-CZ-53-3061-AS20U-0N available during construction 53-TA-3011 (N9) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
PA-3403A 300# Discharge Branch Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3010-BS20-0N 53-PA-3003A E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N BS20 NOT System 19 - 14.6 20 30 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3062-BS20-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
PA-3403B 300# Discharge Branch Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3010-BS20-0N 53-PA-3003B E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N BS20 NOT System 19 - 14.6 20 30 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3063-BS20-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Dechlorination SBS Dosing Line Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3005-AS20U-0N 1/4"-CO-53-3004-DX-T-0 E4477-MC-DG- Techouse NOT 170864 3/4" CO 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 0.0 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3/4"-CO-53-3064-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP Return (Permeate) Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE SP-3006 E4477-MC-DG- Techouse NOT 170864 1" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 1.1 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1"-CZ-53-3065-AS20U-0N available during construction 53-TA-3011 (N4) 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
CIP forwarding ( EDI Conc) Pipe 4477 4477-SIM-P-XB-55163.004 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE SP-3011 E4477-MC-DG- Techouse NOT 170864 1/2" CZ 0N AS20U NOT System 19 - 4 10 15 40 50 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Weak Chemical solution Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-CZ-53-3066-AS20U-0N available during construction 1-1/2"-CZ-53-3059-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
1"-WD-53-3067-AS20U-0N 53-PSV-3001A Inlet PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PSV-3001A E4477-MC-DG- Techouse NOT 170864 1" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
available during construction 1-1/2"-WD-53-3087-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
1"-WD-53-3068-AS20U-0N 53-PSV-3001B Inlet PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PSV-3001B E4477-MC-DG- Techouse NOT 170864 1" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
available during construction 1-1/2"-WD-53-3088-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
2"-WD-53-3069-AS20U-0N 53-PSV-3001A Outlet PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PSV-3001A E4477-MC-DG- Techouse NOT 170864 2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
available during construction 2"-WD-53-3081-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
2"-WD-53-3070-AS20U-0N 53-PSV-3001A Outlet PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 2"-WD-53-3082-AS20U-0N 53-PSV-3001A E4477-MC-DG- Techouse NOT 170864 2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
1"-WD-53-3071-AS20U-0N 53-PSV-3003A Inlet PIPE 4477 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PSV-3003A 1-1/2"-WD-53-3017-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4477-SIM-P-XB-55163.002 available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
1"-WD-53-3072-AS20U-0N 53-PSV-3003B Inlet PIPE 4477 4477-SIM-P-XB-55163.002 N/A N/A L 53 ACTIVE 53-PSV-3003B 1-1/2"-WD-53-3018-AS20U-0N Techouse 170864 1" WD 0N AS20U 6 10 15 35 90 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WD-53-3073-AS20U-0N 53-PSV-3003A Outlet PIPE 4477 4477-SIM-P-XB-55163.002 available N/A N/A during construction L 53 ACTIVE 2"-WD-53-3075-AS20U-0N 53-PSV-3003A 0345 Techouse APPLICABLE 170864 2" WD 0N AS20U APPLICABLE Bergesen Green 6 10 15 35 90 APPLICABLE 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WD-53-3074-AS20U-0N 53-PSV-3003A Outlet PIPE 4477 4477-SIM-P-XB-55163.002 available N/A N/A during construction L 53 ACTIVE 2"-WD-53-3075-AS20U-0N 53-PSV-3003B 0345 Techouse APPLICABLE 170864 2" WD 0N AS20U APPLICABLE Bergesen Green 6 10 15 35 90 APPLICABLE 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WD-53-3075-AS20U-0N 53-PSV-3003A/B Outlet Tundish to Drip Tray PIPE 4477 4477-SIM-P-XB-55163.002 available N/A N/A during construction L 53 ACTIVE Drip Tray 2"-WD-53-3073-AS20U-0N 0345 Techouse APPLICABLE 170864 2" WD 0N AS20U APPLICABLE Bergesen Green Atm 10 15 35 90 APPLICABLE 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WD-53-3076-AS20U-0N 53-TB-3007 Overflow Tundish to Drip Tray PIPE 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 2"-DW-53-3050-AS20U-0N 2"-DW-53-3023-AS20U-0N 0345 Techouse APPLICABLE 170864 2" WD 0N AS20U APPLICABLE Bergesen Green Atm 10 15 35 90 APPLICABLE 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
3/4"-WD-53-3077-AS20U-0N 53-PSV-3001A Inlet Bleed PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-WD-53-3067-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 2"-WD-53-3081-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-WD-53-3078-AS20U-0N 53-PSV-3001B Inlet Bleed PIPE 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 2"-WD-53-3082-AS20U-0N 1"-WD-53-3068-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-WD-53-3079-AS20U-0N 53-CB-3001A Vent PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Tun Dish - 1"-WD-53-3083- 53-CB-3001A E4477-MC-DG- Techouse NOT 170864 3/4" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-WD-53-3080-AS20U-0N 53-CB-3001B Vent PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-WD-53-3083-AS20U-0N 53-CB-3001B E4477-MC-DG- Techouse NOT 170864 3/4" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
2"-WD-53-3081-AS20U-0N 53-PSV-3001A Tundish To drain PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Drip Tray Tundish E4477-MC-DG- Techouse NOT 170864 2" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
2"-WD-53-3082-AS20U-0N 53-PSV-3001B Tundish To drain PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 2"-WD-53-3081-AS20U-0N Tundish E4477-MC-DG- Techouse NOT 170864 2" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.8 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
1"-WD-53-3083-AS20U-0N Filters 53-CB-3001A/B Drain to Drip tRay PIPE 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Drip Tray Tundish E4477-MC-DG- Techouse NOT 170864 1" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
1"-WD-53-3084-AS20U-0N Filters 53-CB-3001A/B Drain to Drip tRay PIPE 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 2"-WD-53-3081-AS20U-0N Tundish E4477-MC-DG- Techouse NOT 170864 1" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-WD-53-3085-AS20U-0N 53-CB-3002A Vent PIPE 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-WD-53-3084-AS20U-0N 53-CB-3002A E4477-MC-DG- Techouse NOT 170864 3/4" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-WD-53-3086-AS20U-0N 53-CB-3002B Vent PIPE 4477 4477-SIM-P-XB-55163.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-WD-53-3084-AS20U-0N 53-CB-3002B E4477-MC-DG- Techouse NOT 170864 3/4" WD 0N AS20U NOT System 19 - Atm 10 15 35 90 NOT 0.1 NOT APPLICABLE NOT APPLICABLE Techouse 11/25/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-CB-3001A to 53-CB-3002A Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3002A 53-CB-3002A E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3087-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
53-CB-3001B to 53-CB-3002B Pipe 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-CB-3002B 53-CB-3002B E4477-MC-DG- Techouse NOT 170864 1-1/2" WD 0N AS20U NOT System 19 - 6 10 15 35 90 NOT 1.9 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1-1/2"-WD-53-3088-AS20U-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-AI-53-3089-AS20U-0N Insturment Manifold A supply 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Instrument Air manifold A 1"-AI-53-3011-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" AI 0N AS20U NOT HOLD 6 20 30 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-AI-53-3090-AS20U-0N Insturment Manifold B supply 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Instrument Air manifold B 1"-AI-53-3011-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" AI 0N AS20U NOT HOLD 6 20 30 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-AI-53-3091-AS20U-0N Insturment Manifold C supply 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Instrument Air manifold C 1"-AI-53-3011-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" AI 0N AS20U NOT HOLD 6 20 30 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-AI-53-3092-AS20U-0N Instrument Manifold D supply 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Instrument Air manifold D 1"-AI-53-3011-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" AI 0N AS20U NOT HOLD 6 20 30 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
3/4"-AI-53-3093-AS20U-0N Instrument Manifold E supply 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE Instrument Air manifold E 1"-AI-53-3011-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" AI 0N AS20U NOT HOLD 6 20 30 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT NOT filtered fresh
3/4"-AI-53-3094-AS20U-0N Instrument Manifold F supply 4477 4477-SIM-P-XB-55163.001
available
N/A N/A
during construction
L 53 ACTIVE Instrument Air manifold F 1"-AI-53-3011-AS20U-0N
0345
Techouse
APPLICABLE
170864 3/4" AI 0N AS20U
APPLICABLE
HOLD 6 20 30 35 90
APPLICABLE
0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER
water, <100
NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
3/4"-AI-53-3095-AS20U-0N Non-Critical Instrument Manifold supply 4477 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE ExP Cabinet 53-IB-3010 1"-AI-53-3012-AS20U-0N E4477-MC-DG- Techouse NOT 170864 3/4" AI 0N AS20U NOT HOLD 6 20 30 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT NOT filtered fresh
3/4"-AI-53-3096-AS20U-0N Redox Sample bleed supplu 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 1/2"-WD-53-3007-DX-T--0N 1-1/2"-WD-53-3005-AS20U-0N 0345 Techouse APPLICABLE 170864 3/4" AI 0N AS20U APPLICABLE HOLD 6 20 30 35 90 APPLICABLE 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT NOT filtered fresh
3/4"-AI-53-3097-AS20U-0N Redox Sample bleed supplu 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE 53-BL-3016 1-1/2"-WD-53-3005-AS20U-0N 0345 Techouse APPLICABLE 170864 3/4" AI 0N AS20U APPLICABLE HOLD 6 20 30 35 90 APPLICABLE 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 11/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Gas FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
3/4"-CO-53-3098-AS20U-0N SBS Tank Overflow Pipe 4477 4477-SIM-P-XB-55163.001 available N/A N/A during construction L 53 ACTIVE Drip Tray 53-TB-3005 (N6) 0345 Techouse APPLICABLE 170864 3/4" CO 0N AS20U APPLICABLE Bergesen Green 6 10 15 35 90 APPLICABLE 0.01 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
3/4"-DW-53-3099-AS20U-0N EDI Electrolyte Drain Pipe 4477 4477-SIM-P-XB-55163.003 available N/A N/A during construction L 53 ACTIVE Drip Tray 1/2"-WD-53-3007-DX-T-0 0345 Techouse APPLICABLE 170864 3/4" DW 0N AS20U APPLICABLE Bergesen Green Atm 10 15 35 90 APPLICABLE 0.6 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

TUBING

5 micron
Dechlorination SBS Dosing Supply 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PB-3004A Outlet E4477-MC-DG- Techouse NOT 170864 1/2" CO 0N AS20U NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2""-CO-53-3004-DX-T-0N available during construction 1/2""-CO-53-3004-DX-T-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Dechlorination SBS Dosing Supply 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PB-3004B E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/4"-CO-53-3004-DX-T-0N available during construction 3/4"-WD-53-3064-AS20U-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
53-PSV-3002A Inlet 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PSV-3002A E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
1/4"-CO-53-3005-DX-T-0N available during construction 1/4"-CO-53-3004-DX-T-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
53-PSV-3002A Outlet 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3005 (N2A) 53-PSV-3002A E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
1/4"-CO-53-3006-DX-T-0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Redox 530AIT-3067 Supply 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1"-DW-53-3050-AS20U-0N 1-1/2"-WD-53-3005-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3007-DX-T--0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Concentrate Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3036-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3008-DX-T--0N available during construction 53-CB-3010A (N1A) 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Concentrate Outlet 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3009-DX-T--0N available during construction 1/2"-WD-53-3012-DX-T--0N 53-CB-3010A (N3A) 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

Page 10
BWO DRW. Reference Combined Thermal Flushing Flange Heat Tracing Flow
Service Code Insulation (as Pipe Class (as Oper. Design Standard Calculated Flushing and Flushing Chemical Internal Pickling External Pickling Critical Line Fluid Density
Line No Service / Description Tag. Reg. Project Comment Discipline System Status To Line No From Line No Package No Supplier Sparing % P.O. No Line Size (as per 4477) per 4477) per 4477) Piping Class Coating Oper. Pressure Design Pressure Test Pressure Temperature Temperature Velocity (m/s) Velocity (m/s) Replaced Line No Foreign Line No Modified By Modified Date Site Code DCN Number and Acoustic Drying Medium Required Cleaning and Passivation Hot Oil Flushing and Passivation Fluid State Fluids Management Temperature Identification (kg/m3) Momentum AIV Assessment END
PID Drawing No Isometric Drawing No Other Drawing No Datasheet Certificate DOC. No Insulation Cleaniness Criticality (deg C) (kg/sm2)

5 micron
EDI 53-CB-3010A Electrolyte Outlet 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3010-DX-T--0N available during construction TP M-910XX [HOLD] 53-CB-3010A (N5A) 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010B Concentrate Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3011-DX-T--0N available during construction 53-CB-3010B (N1B) 1-1/2"-WD-53-3039-AS20U-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Concentrate Outlet 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 2"-DW-53-3050-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3012-DX-T--0N available during construction 53-CB-3010B (N3B) 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
EDI 53-CB-3010A Electrolyte Outlet 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1/2"-WD-53-3010-DX-T--0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3013-DX-T--0N available during construction 53-CB-3010B (N5B) 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Dechlorination SBS Dosing Supply 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PB-3004A Outlet E4477-MC-DG- Techouse NOT 170864 1/2" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/4"-CO-53-3018-DX-T-0N available during construction 1/4"-CO-53-3004-DX-T-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
53-PB-3004A Inlet 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PB-3004B Intlet 53-TB-3005 (N1A) E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/4"-CO-53-3019-DX-T-0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
53-PB-3004B Inlet 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PB-3004A Intlet E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/4"-CO-53-3020-DX-T-0N available during construction 1/4"-CO-53-3019-DX-T-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
53-PSV-3002B Inlet 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-PSV-3002A E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
1/4"-CO-53-3021-DX-T-0N available during construction 1/4"-CO-53-3018-DX-T-0N 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
53-PSV-3002B Outlet 4477 Tubing 4477-SIM-P-XB-55163.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 53-TB-3005 (N2B) 53-PSV-3002A E4477-MC-DG- Techouse NOT 170864 1/4" CO 0N DX NOT HOLD 6 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid FreshWater Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
1/4"-CO-53-3022-DX-T-0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Analyser Bank & 53-AE-3058 (Silica) Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3043-AS20U-0N 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3023-DX-T--0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Analyser 53-AE-3056 (Conductivity) Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3043-AS20U-0N 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3024-DX-T--0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Analyser 53-AE-3057 (pH) Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3043-AS20U-0N 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3025-DX-T--0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Analyser 53-AE-3059 (Sodium) Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3043-AS20U-0N 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3026-DX-T--0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

5 micron
Analyser 53-AE-3060 (TOC) Supply 4477 Tubing 4477-SIM-P-XB-55163.003 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 53 ACTIVE 1-1/2"-WD-53-3043-AS20U-0N 1-1/2"-WD-53-3042-AS20U-0N E4477-MC-DG- Techouse NOT 170864 1/2" WD 0N DX NOT HOLD 5.25 10 15 35 90 NOT 0.5 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid RO Permeate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
1/2"-WD-53-3027-DX-T--0N available during construction 0345 APPLICABLE APPLICABLE APPLICABLE water, <100
ppm Chloride

CPP System (55)

5 micron
Condensate Supply to CPP Cartridge Filters Pipe 4477 4477-SIM-P-XB-55164.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE TP-M92151 E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WQ-55-3401-AS20U-0N available during construction 4"-WQ-55-3402-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Inlet to CPP Cartridge Filters 55-CB-3401A Pipe 4477 4477-SIM-P-XB-55164.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3401A (N1) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3402-AS20U-0N available during construction 4"-WQ-55-3401-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Inlet to CPP Cartridge Filters 55-CB-3401B Pipe 4477 4477-SIM-P-XB-55164.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3401B (N1) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3403-AS20U-0N available during construction 4"-WQ-55-3401-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Outlet of CPP Cartridge Filter 55-CB-3401A Pipe 4477 4477-SIM-P-XB-55164.001 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3401A (N2) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3404-AS20U-0N available during construction 4"-WQ-55-3406-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
4"-WQ-55-3405-AS20U-0N Outlet of CPP Cartridge Filter 55-CB-3401B Pipe 4477 4477-SIM-P-XB-55164.001 available N/A N/A during construction L 55 ACTIVE 4"-WQ-55-3406-AS20U-0N 55-CB-3401B (N2) 0345 Techouse APPLICABLE 170864 4" WQ 0N AS20U APPLICABLE Bergesen Green 7 13 19.5 50 90 APPLICABLE 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
4"-WQ-55-3406-AS20U-0N Outlet of CPP Cartridge Filter manifold Pipe 4477 4477-SIM-P-XB-55164.001 available N/A N/A during construction L 55 ACTIVE 4"-WQ-55-3410-AS20U-0N 4"-WQ-55-3404-AS20U-0N 0345 Techouse APPLICABLE 170864 4" WQ 0N AS20U APPLICABLE Bergesen Green 7 13 19.5 50 90 APPLICABLE 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WQ-55-3407-AS20U-0N Cartridge Filter 55-CB-3401A Drain Pipe 4477 4477-SIM-P-XB-55164.001 available N/A N/A during construction L 55 ACTIVE 2"-WQ-55-3409-AS20U-0N 55-CB-3401A (N4) 0345 Techouse APPLICABLE 170864 2" WQ 0N AS20U APPLICABLE Bergesen Green Atm 13 19.5 50 90 APPLICABLE 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WQ-55-3408-AS20U-0N Cartridge Filter 55-CB-3401B Drain Pipe 4477 4477-SIM-P-XB-55164.001 available N/A N/A during construction L 55 ACTIVE 2"-WQ-55-3409-AS20U-0N 55-CB-3401B (N4) 0345 Techouse APPLICABLE 170864 2" WQ 0N AS20U APPLICABLE Bergesen Green Atm 13 19.5 50 90 APPLICABLE 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WQ-55-3409-AS20U-0N Cartridge Filter Common Drain Pipe 4477 4477-SIM-P-XB-55164.001 available N/A N/A during construction L 55 ACTIVE 4"-WD-55-3429-AS20U-0N 2"-WQ-55-3407-AS20U-0N 0345 Techouse APPLICABLE 170864 2" WQ 0N AS20U APPLICABLE Bergesen Green Atm 13 19.5 50 90 APPLICABLE 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402A Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402A (N1) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3410-AS20U-0N available during construction 4"-WQ-55-3406-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402B Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402B (N1) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3411-AS20U-0N available during construction 4"-WQ-55-3406-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402C Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402C (N1) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3412-AS20U-0N available during construction 4"-WQ-55-3406-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402D Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402D (N1) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3413-AS20U-0N available during construction 4"-WQ-55-3406-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402A Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402A (N2) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Polished Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3414-AS20U-0N available during construction 4"-WQ-55-3418-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402B Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402B (N2) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Polished Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3415-AS20U-0N available during construction 4"-WQ-55-3418-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402C Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402C (N2) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Polished Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3416-AS20U-0N available during construction 4"-WQ-55-3418-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402D Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402D (N2) E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Polished Condensate Low NOT APPLICABLE YES 1000 NOT APPLICABLE NO
4"-WQ-55-3417-AS20U-0N available during construction 4"-WQ-55-3418-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed Combined Product Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE TP-M-92152 E4477-MC-DG- Techouse NOT 170864 4" WQ 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Polished Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WQ-55-3418-AS20U-0N available during construction 4"-WQ-55-3414-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Rinse Supply Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE TP-M-92153 E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3419-AS20U-0N available during construction 4"-WD-55-3421-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Eductor Feed Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 0.76 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3420-AS20U-0N available during construction 4"-WD-55-3419-AS20U-0N 4"-WD-55-3436-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402A Rinse Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402A (N4) E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3421-AS20U-0N available during construction 4"-WD-55-3419-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402B Rinse Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402B (N4) E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3422-AS20U-0N available during construction 4"-WD-55-3419-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402C Rinse Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402C (N4) E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3423-AS20U-0N available during construction 4"-WD-55-3419-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402D Rinse Inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE 55-CB-3402D (N4) E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3424-AS20U-0N available during construction 4"-WD-55-3419-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402A Rinse Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3425-AS20U-0N available during construction 4"-WD-55-3429-AS20U-0N 4"-WQ-55-3414-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402B Rinse Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3426-AS20U-0N available during construction 4"-WD-55-3429-AS20U-0N 4"-WQ-55-3415-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402C Rinse Outlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3427-AS20U-0N available during construction 4"-WD-55-3429-AS20U-0N 4"-WQ-55-3416-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
4"-WD-55-3428-AS20U-0N Mixed Bed IX Vessel 55-CB-3402D Rinse Outlet Pipe 4477 4477-SIM-P-XB-55164.002 available N/A N/A during construction L 55 ACTIVE 4"-WD-55-3429-AS20U-0N 4"-WQ-55-3417-AS20U-0N 0345 Techouse APPLICABLE 170864 4" WD 0N AS20U APPLICABLE Bergesen Green 7 13 19.5 50 90 APPLICABLE 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
4"-WD-55-3429-AS20U-0N Mixed Bed Common Rinse Outlet Pipe 4477 4477-SIM-P-XB-55164.002 available N/A N/A during construction L 55 ACTIVE TP-M-92X15 4"-WQ-55-3414-AS20U-0N 0345 Techouse APPLICABLE 170864 4" WD 0N AS20U APPLICABLE Bergesen Green 7 13 19.5 50 90 APPLICABLE 1.96 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WQ-55-3430-AS20U-0N Mixed Bed IX Vessel 55-CB-3402A Drain Pipe 4477 4477-SIM-P-XB-55164.002 available N/A N/A during construction L 55 ACTIVE 2"-WQ-55-3409-AS20U-0N 4"-WQ-55-3414-AS20U-0N 0345 Techouse APPLICABLE 170864 2" WQ 0N AS20U APPLICABLE Bergesen Green Atm 13 19.5 50 90 APPLICABLE 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WQ-55-3431-AS20U-0N Mixed Bed IX Vessel 55-CB-3402B Drain Pipe 4477 4477-SIM-P-XB-55164.002 available N/A N/A during construction L 55 ACTIVE 2"-WQ-55-3409-AS20U-0N 4"-WQ-55-3415-AS20U-0N 0345 Techouse APPLICABLE 170864 2" WQ 0N AS20U APPLICABLE Bergesen Green Atm 13 19.5 50 90 APPLICABLE 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
TBC once ISO's developed and TBC when pipe is certified E4477-MC-DG- NOT NOT System 19 - NOT filtered fresh
2"-WQ-55-3432-AS20U-0N Mixed Bed IX Vessel 55-CB-3402C Drain Pipe 4477 4477-SIM-P-XB-55164.002 available N/A N/A during construction L 55 ACTIVE 2"-WQ-55-3409-AS20U-0N 4"-WQ-55-3416-AS20U-0N 0345 Techouse APPLICABLE 170864 2" WQ 0N AS20U APPLICABLE Bergesen Green Atm 13 19.5 50 90 APPLICABLE 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER water, <100 NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
ppm Chloride

5 micron
Mixed Bed IX Vessel 55-CB-3402D Drain Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE E4477-MC-DG- Techouse NOT 170864 2" WQ 0N AS20U NOT System 19 - Atm 13 19.5 50 90 NOT 1.46 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Condensate Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
2"-WQ-55-3433-AS20U-0N available during construction 2"-WQ-55-3409-AS20U-0N 4"-WQ-55-3417-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Nitrogen Supply Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE Hose Connector TP-M-92063 E4477-MC-DG- Techouse NOT 170864 1" GN 0N AC21 NOT System 16 - 6 13 19.5 50 90 NOT 5.99 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Gas Nitrogen Low NOT APPLICABLE NO 1.2506 NOT APPLICABLE NO
1"-GN-55-3434-AC21-0N available during construction 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Eductor inlet Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE E4477-MC-DG- Techouse NOT 170864 4" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 0.62 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
4"-WD-55-3436-AS20U-0N available during construction 4"-WD-55-3420-AS20U-0N 4"-WD-55-3419-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

5 micron
Rinse Spill back line Pipe 4477 4477-SIM-P-XB-55164.002 TBC once ISO's developed and N/A N/A TBC when pipe is certified L 55 ACTIVE TP-M-92154 E4477-MC-DG- Techouse NOT 170864 3" WD 0N AS20U NOT System 19 - 7 13 19.5 50 90 NOT 2.06 NOT APPLICABLE NOT APPLICABLE Techouse 9/22/2022 N/A N/A NOT APPLICABLE NO WATER filtered fresh NO YES NO YES Liquid Demin Water Low NOT APPLICABLE NO 1000 NOT APPLICABLE NO
3"-WD-55-3437-AS20U-0N available during construction 4"-WD-55-3436-AS20U-0N 0345 APPLICABLE APPLICABLE Bergesen Green APPLICABLE water, <100
ppm Chloride

Page 11
Pipe Wall Thickness

AS20U "
ND 0.75 1 1.5 2 3 4
OD (mm) 26.7 33.4 48.3 60.3 88.9 114.3
THK (mm) 3.73 4.55 5.08 5.54 3.05 3.05
ID 19.24 24.3 38.14 49.22 82.8 108.2

BS20
ND 1" 1.5" 2" 3" 4"
OD (mm) 33.4 48.3 60.3 88.9 114.3
THK (mm) 4.55 5.08 5.54 7.62 8.56

AC21
ND 1"
OD (mm) 33.4
THK (mm) 4.55

You might also like