DESIGN ANALYSIS FOR FOOTINGS

F1 F2
Design Criteria: Design Criteria:
Assumed Wt. = 8% Assumed Wt. = 8%
Column width, c = 0.25 m Column width, c = 0.25 m
Load (column) = 105.05 KN Load (column) = 52.526088 KN
Total Load, w = 113.46 KN Total Load, w = 89.97 KN
Soil Pressure, P = 100 KPa Soil Pressure, P = 100 KPa
fs = 165.6 MPa (Gr. 40) fs = 165.6 MPa (Gr. 40)
fc' = 20.7 MPa (3000psi) fc' = 20.7 MPa (3000psi)
fc (.45fc') = 9.315 fc (.45fc') = 9.315
n = 10 n = 10
k [n/(n+fs/fc)] = 0.36 k [n/(n+fs/fc)] = 0.36
j (1-k/3) = 0.88 j (1-k/3) = 0.88
R (1/2fckj) = 1.475496 MPa R (1/2fckj) = 1.475496 MPa
Va (0.09*sqrt(fc') = 0.40947527 MPa va (0.09*sqrt(fc') = 0.4094753 MPa
Analysis: Analysis:
2
Area = 1.1345635 m Area = 0.8996964 m2
Width, b2 = 1.06515891 say 1.1 m Width, b2 = 0.9485233 say 1 m
net upward P, p = 86.8199803 KPa net upward P, p = 52.526088 KPa
Critical for M, x = 0.425 Critical for M, x = 0.375
Moment, M = 8.62502242 KN-m Moment, M = 3.6932406 KN-m
Depth, D (M/Rb)1/2 = 0.07 say Depth, D (M/Rb)1/2 = 0.05 say
Conc. Cover = 0.05 m Conc. Cover = 0.05 m
Total Depth, d = 0.1229 say 0.20 m Total Depth, d = 0.1000 say 0.20 m
Critical for V, y = 0.3021 Critical for V, y = 0.2750
Shear, V (pby) = 28.8513524 KN Shear, V (pby) = 14.443073 KN
v (V/bd) = 0.21341709 <0.4025 :.safe v (V/bd) = 0.1443867 <0.4025 :.safe
Vp (p{b2-(c+d)2} = 14607.8004 N Vp (p{b2-(c+d)2} = 6435.567 N
Ap (c+d)(d)(4) = 0.18331339 Ap (c+d)(d)(4) = 0.1400549
vp (Vp/Ap) = 0.079687581 MPa <0.4025 :.safe vp (Vp/Ap) = 0.04595032 MPa <0.4025 :.safe
Steel (M/fsjd) 2 Steel (M/fsjd) 2
= 481.584967 mm = 253.35658 mm
2
As' (16mm dia.) = 134.041287 mm As' (12mm dia.) = 75.398224 mm2
No. of Bars, n = 3.59281069 say 3.60 pcs No. of Bars, n = 3.360246 say 3.40 pcs