You are on page 1of 13

BUILDING SERVICES– VII

AUDITORIUM DESIGN
7TH Semester School of Architecture

• ASHISH M GOWDA
• PRERANA MANJUNATH
• SAHITHI C
• TEJAS GOWDA
CONFERENCE
ROOM DESIGN
A U D I TO R I U M D E S I G N
RT GRAPH
CALCULATIONS:

Step 1: SURFACE AREA CALCULATION


0.6- 0.9 sq.m /person

Step 2: VOLUME CALCULATION


3-4.5 cum/person

Step 3: RT GRAPH
CONFERENCE HALL- 0.6-0.8

Step 4: FORM DEVELOPMENT


PLAN SCALE 1:75
FA N A R R A N G E M E N T

Surface area= 48sqm


SA/P = .96sqm
Volume = 196cum
V/P = 3.9cum
Form angle =19.6degree
SECTION SCALE 1:75

D E TA I L S

Chair measurement - 60cm


Row spacing -

814cm

868cm

914cm

1015cm

Distance between the screen


- 2min-8max
VISIBILITY RANGE

SCREEN
3m X 2.5m

VISIBILITY RANGE CONSIDERATION 1

SECTION SCALE 1:75

SCREEN
3m X 2.5m

VISIBILITY RANGE CONSIDERATION 2


SECTION SCALE 1:75
SPEAKER
SOUND
REFLECTION
SOLUTION
TO CONTROL THE SOUND
REFLECTION TO THE SIDE
WALLS ,BY NOT AFFECTING
THE FORM OF THE BUILDING

USING WINDOWS AND


VENTILATOR WHICH CAN BE
ADJUSTED TO THE REQUIRED
ANGEL ACTING AS A BARRIER
TO OUTER SOUND AND NOISE
TERRACE PLAN SCALE 1:75 SKY LIGHT FOR VENTILATION
AND
SOUND REFLECTION

SURFACE AREA - .6m X 1.8m

ADJUSTABLE
SOUND ABSORBER

SECTION SCALE 1:75

WINDOWS FOR VENTILATION


AND
SOUND REFLECTION
SURFACE AREA - .6m X 1.8m
SKY LIGHT FOR VENTILATION
AND
SOUND REFLECTION

WINDOWS FOR VENTILATION


AND
SOUND REFLECTION
Location Material NRC S [m²] S
SIDE WALL A Smooth brickwork with flush pointing 0.04 14.15 0.57
SIDE WALL B Smooth brickwork with flush pointing 0.04 14.15 0.57
CURVE WALL Smooth brickwork with flush pointing 0.04 31.5 1.26
PODIUM WALL A Smooth brickwork with flush pointing 0.04 9.25 0.37
PODIUM WALL B Smooth brickwork with flush pointing 0.04 9.25 0.37
PODIUM WALL C Smooth brickwork with flush pointing 0.04 25.9 1.04
SIDE WALL A Plywood, hardwood panels over 25mm airspace on solid backing with 3.04
absorbent material in air space 0.175
17.35
SIDE WALL B Plywood, hardwood panels over 25mm airspace on solid backing with 3.04
absorbent material in air space 0.175
17.35
CURVE WALL Plywood, hardwood panels over 25mm airspace on solid backing with 4.34
absorbent material in air space 0.175
24.78
PODIUM WALL A Plywood, hardwood panels over 25mm airspace on solid backing with 1.62
absorbent material in air space 0.175
9.25
PODIUM WALL B Plywood, hardwood panels over 25mm airspace on solid backing with 1.62
absorbent material in air space 0.175
9.25
PODIUM WALL C Plywood, hardwood panels over 25mm airspace on solid backing with 3.87
absorbent material in air space 0.175
22.12
PODIUM FLOOR 1.48
Wooden floor on joists 0.093333333 15.85
CONFERENCE FLOOR 6mm pile carpet bonded to closed-cell foam underlay 0.241666667 7.61
31.5
CEILING 75MM WOODWOOL FIXED DIRECTLY TO CONCRETE, PRE 8.16
0.15
SCREEDED SURFACE FACING BACKING 54.37
WINDOW Double glazing, 2-3mm glass, 10mm air gap 0.05 6.4 0.32
DOOR 1 Acoustic door, steel frame, double seals, absorbant in airspace, 0.451666667 3.04
6.72
DOOR 2 Solid timber door 0.096666667 3.78 0.37
CEILING VENTILATOR Double glazing, 2-3mm glass, 10mm air gap 0.05 7.8 0.39
PROJECTOR BOARD Acoustic banner, 0.5 kg/m2 wool serge, 100mm from wall 0.62 6 3.72
FURNITURE Fully upholstered seats (per item) in m2 0.181666667 20.25 3.68
ΣS 50.44
V 196 RT 0.63

SOUND ABSORPTION COEFFICIENT

S SURFACE AREA OF MATERIAL

V VOLUME OF THE ROOM


THANK YOU

You might also like