You are on page 1of 1

AKAR INDAH ENGINEERING SDN BHD (607376-K)

CO9P TOWER 1, UPM-MTDC


TECHNOLOGY CENTRE, UPM SERDANG,
43400 SELANGOR, MALAYSIA
Email: technical.aie@gmail.com

MACHINE DECKEL FP1

Complete
No Part Item Issues Before Countermeasure After Remark Status
date
MECHANICAL
Shift rod Shaft Broken shaft part Fabricate new
shaft for
replacment

Pending

M2

Motor (axis) Motor 1) Humming Remove the motor


2) Cut off when for further
apply load inspection
3) Cutt of when
speed reach to Additional
Pending
315 (without load) Finding

Lubricant tank Gasket Rust Replace new


gasket
Pending

ELECTRICAL
DRO control Push button When pressed, Remove and
button the light on the replace new button
push button is not
Pending
visible

DRO control Speed Loose during Remove the loose


button controller turning speed controller,
install new speed
Pending
controller

Axis indicator LED X,Y,Z Missing / Remove


panel indicator panel Mulfunction mulfunction LED
M2
and install new Pending
LED

Control panel Selector The selector Install new


switch spindle switch cover is selector switch
rotation missing.
(cw/ccw)

Pending