VICINITY MAP 1
WP
WP
S 2-A,B PP
2
PP
STACU
3
tv
S 3-E,F,G
S 2-C,D
B
E E
F WP
G C D WP
LIGHTING-CEILING LEGEND POWER & AUX. LEGEND
WH
POWER CONVENIENCE OUTLET (DUPLEX TYPE)
WALL LIGHT INSTALLED PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS
DATA / TEL
TELEPHONE, DATA, COMMUNICATIONS
INSTALLED PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS
1 2ND FLOOR LIGHTING LAYOUT 2 2ND FLOOR POWER LAYOUT
SCALE: 1:100 MTS. SCALE: 1:100 MTS.
OUTDOOR SPOTLIGHT
CATV
CABLE TV OUTLET E-1 E-1
INSTALLED PER MANUFACTURER'S SPECIFICATIONS & REQUIREMENTS
CCTV
4-6W CCTV CAMERA
M KILOWATT HOUR METTER
EF
230V, 60HZ, ±50W, SILENT TYPE
CEILING MOUNTED FAN WITH SQUARE
MODERN GRILLE
ELECTRICAL NOTES:
1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE LATEST PROVISIONS OF THE PHILIPPINES
ELECTRICAL CODE AND SHALL COMPLY WITH THE RULES AND REGULATION OF THE LOCAL GOVERNMENT AUTHORITIES
CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS AND ORDINANCE AND WITH THE REQUIREMENTS OF THE LOCAL
ELECTRIC UTILITY COMPANY.
2. POWER SUPPLY TO THE PROJECT SHALL BE 230 VOLTS, SINGLE PHASE, 2 WIRES AND 60 HERTZ FROM MERALCO.
3. TYPE OF WIRING INSTALLATION SHALL BE DONE IN RIGID METAL CONDUIT (R.M.C.) FOR MAIN SERVICE ENTRANCE AND
UNPLASTICIZED POLYVINYL CHLORIDE (uPVC) ON ALL BRANCH CIRCUITS. UNLESS OTHERWISE SPECIFIED ON THE PLAN,
THE MINIMUM SIZE OF WIRE TO BE USED SHALL BE NO. 2.0mm2, THHN TYPE IN 20mmØ uPVC. FOLLOW SPECIFICATIONS FOR
MATERIALS AND PRODUCTS.
4. ALL ELECTRICAL EQUIPMENT TO BE USED SHALL BE EQUIPPED WITH PROPER AND ADEQUATE GROUNDING SYSTEM.
5. MOUNTING HEADS:
A. LIGHTING CONTROL SWITCH : 1.48 M ABOVE FINISH FLOOR LINE (VERIFY SPECS.)
B. CONVENIENCE OUTLET : 0.30 M ABOVE FINISH FLOOR LINE (VERIFY
SPECS.) 2-8.0mm² THHN & 1-8.0mm² THHN
C. SPECIAL PURPOSED OUTLET : AS REQUIRED BY EQUIPMENT SERVED (VERIFY SPECS.)
IN 34" Ø PVC PIPE
D. PANEL BOARD : 1.50 M ABOVE FINISH FLOOR LINE (VERIFY SPECS.)
60AT
7.
8.
ALL ELECTRICAL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED FOR BOTH LOCATION AND PURPOSES.
THE CONTRACTOR SHALL STRICTLY FOLLOW SPECIFICATIONS FOR MATERIALS BRANDS AND OTHER MATERIALS NEEDED MCB
FOR A COMPLETE INSTALLATION. NO OTHER BRANDS SHALL BE USED, UNLESS/OTHERWISE SPECIFIED IN THE
SPECIFICATIONS OR IN THE DRAWINGS. THE USE OF SUBSTANDARD MATERIALS SHALL BE REJECTED AND MUST BE
REPLACED AT THE CONTRACTORS EXPENSE. PP
9. ALL ELECTRICAL WORKS HEREIN SHALL BE UNDER THE DIRECT SUPERVISION OF AN EXPERIENCED ELECTRICAL ENGINEER,
OR A REGISTERED MASTER ELECTRICIAN WITH EXPERIENCE IN COMPLEX ELECTRICAL WORKS AND RENOVATION
PROJECTS. THE CONTRACTOR SHALL UNDERSTAND THE CONTENTS OF THE SPECIFICATIONS AND THE DRAWINGS BEFORE
ANY SUPPLY AND INSTALLATIONS.
TAP TO EXISTING
MAIN CIRCUIT
BREAKER