COLUMNS DIMENSIONS AND REINFORCEMENT SCHEDULE

TYPE
FOUNDATION TO GF SLAB GF SLAB TO 1st FLOOR SLAB 1st FLOOR SLAB TO HR SLAB
OF
COLUMN

500 500 500

200

200

200
C1**

SIZE = 200x500mm SIZE = 200x500mm SIZE = 200x500mm


VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS

10-T16Ø T8Ø @ 150mm C/C 10-T16Ø T8Ø @ 150mm C/C - -

500

200
C1*

SIZE = 200x500mm

VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS


10-T16Ø T8Ø @ 150mm C/C - - - -

500 500
200

200
C1
SIZE = 200x500mm SIZE = 200x500mm
VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS

10-T16Ø T8Ø @ 150mm C/C 10-T16Ø T8Ø @ 150mm C/C - -

600
200

C2

SIZE = 200x600mm

VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS


10-T16Ø T8Ø @ 150mm C/C - - - -

600 600 600


200

200

200
C3

SIZE = 200x600mm SIZE = 200x600mm SIZE = 200x600mm

VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS VERTICAL BARS STIRRUPS


14-T16Ø T8Ø @ 150mm C/C 14-T16Ø T8Ø @ 150mm C/C 14-T16Ø T8Ø @ 150mm C/C