You are on page 1of 29

CLIENT : NATIONAL AUTHORITY FOR TUNNELS

PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS


ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (03.2)

EARTH WORK
Reference shall be made to section (3) of Specifications.
Excavation in ordinary soil including scaffoldings and
transportation of excavated material to dump areas approved
3.2.01
by the Organization and concerned Authorities and
compensation for excavation outside the geometric measured
volumes. (Including excavation for external stairs and
escalators).
Rate per cubic meter 3
m 2600

Excavation in rock including scaffoldings and transportation of


3.2.02 excavated material to dump areas approved by the
Organization and concerned Authorities and compensation for
excavation outside the geometric measured volumes.
(Including excavation for external stairs and escalators).
Rate per cubic meter 3
m 9525

As previous item (3.2.01), but for manual excavation for


3.2.03 exploratory pits and trenches including filling of these pits and
trenches with clean sand, according to the existing public
utilities drawings.
Rate per cubic meter
a. From existing level (0.00) level to (-2.00m) 3
m NA
b. For parts deeper than (-2.00m) to (- 4.00m) 3
m NA

Total to Collection

Page 1 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
Replacement soil (structural fill) under foundation level with
soil as per specified in geotechnical report. measured from
bottom of plain concrete by layers not more than 250 mm for
3.2.04
each layer thickness. The price includes the compaction till not
less than 95% as compaction percentage from modified
proctor test and all requested tests as per geotechnical report,
project specifications and the Egyptian code of practice of soil
mechanics. …. (m3).
Rate per cubic meter 3
m 12000

backfill soil between and above foundation level with well


graded sand as per specified in project specs. measured from
the foundation level by layers not more than 250 mm for each
3.2.05
layer thickness. The price includes the compaction till not less
than 95% as compaction percentage from modified proctor
test and all requested tests as per geotechnical report, project
specifications and the Egyptian code of practice of soil
mechanics.
Rate per cubic meter 3
m 40000

5. Replacement soil under foundation level with cemented


3.2.06 sand (200 kg/m3) as shown in design drawings. The price
includes all requested tests as per project specifications and
the Egyptian code of practice of soil mechanics
Rate per cubic meter 3
m NA

Fill soil behind the retaining walls and narrow areas with
3.2.07 cemented sand (150 kg/m3) as shown in design drawings. The
price includes all requested tests as per project specifications
and the Egyptian code of practice of soil mechanics

Rate per cubic meter 3


m NA

Total to Collection

Page 2 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
3.2.08 Replacement soil backfill a layer of( aggregate + sand) at a
ratio of (2:1) between and above foundation level as per
specified in project specs. measured from the foundation level
by layers not more than 250 mm for each layer thickness. The
price includes the compaction till not less than 95% as m
3
NA
compaction percentage from modified proctor test and all
requested tests as per geotechnical report, project
specifications and the Egyptian code of practice of soil
mechanics.

3.2.09 Replacement soil backfill a layer of (aggregate + sand) at a


ratio of (1:1) between and above foundation level as per
specified in project specs. measured from the foundation level
by layers not more than 250 mm for each layer thickness. The
price includes the compaction till not less than 95% as m
3
NA
compaction percentage from modified proctor test and all
requested tests as per geotechnical report, project
specifications and the Egyptian code of practice of soil
mechanics.

shoring
3.2.10 Supply and installation of shoring systems as needed to
protect adjacent properties,Rate includes the design of the
shoring system and submission of all necessary drawings and
C.N for the organization approval. Rate per linear meter of the
shoring system (secent piles,sheet piles,purlin wall ...etc.)
Rate per linear meter m NA

3.2.11 Supply & install of dewatering system by reasonable system


according to the approved geotechnical report. the price must
include submit of the full detailed drawings, design calculation L.S NA
of the dewatering system, specs and method statement for
review before construction.

3.2.12 Dewatering of ground and surface water and transportation of


water either to sewerage networks or open drains during the L.S
NA
whole foundation construction period (till completion of /month
filling),
Total to Collection

Page 3 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (03.2)

EARTH WORK
Total of page 1

Total of page2

Total of page3

Total to Summary

Page 4 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (05)

CONCRETE WORKS
Reference is to be made to section (5) of Specifications.

Plain Concrete

N.B.: Rates of concrete works include all expenses related to


the supply of materials, labour, plant, equipment, mixes design
.mixing, scaffolding, installation and dismantling of forms,
placement, construction joints, curing, testing, site laboratory,
admixtures (additives such as plasticizer) and all required to
conform with drawings and specifications, and satisfy
contractual obligations .The price also includes the use of
sulphate resistant cement and other requirements as
indicated to soil report and durability requirements stated in
spec item (1.5).

Plain concrete of minimum characteristic cube strength 20


MPa {Equivalent cylinder strength 16 MPa} of minimum
5.01
ordinary portland cement content 300 kg/m3 cement/cubic
meter of concrete.
Rate per cubic meter
a. For foundation, pads & pile caps. 3
m 3000
b. For external stairs and escalators 3
m 50
c. For fence foundations and ground beams. 3
m NA
Rate per square meter
a. Blinding layer with thickness 100 mm under tie beams or 2
m 1000
raft foundation

Plain concrete of minimum characteristic cube strength 20


MPa {Equivalent cylinder strength 16 MPa} of minimum
5.02
sulphate resistant cement content 300 kg/m3 cement/cubic
meter of concrete.
Rate per cubic meter
a. For foundation, pads & pile caps. 3
m NA
b. For external stairs and escalators 3
m NA
c. For fence foundations and ground beams. 3
m NA
Rate per square meter
a. Blinding layer with thickness 100 mm under tie beams or 2
m NA
raft foundation

Total to Collection

Page 5 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
Reinforced Concrete
N.B.: Rates of concrete works include all expenses related to
the supply of materials, labour, plant, equipment, mixes design
.mixing, scaffolding, installation and dismantling of forms,
placement, construction joints, curing, testing, site laboratory,
admixtures (additives such as plasticizer) and all required to
conform with drawings and specifications, and satisfy
contractual obligations . Rates excludes reinforcement unless
otherwise stated in item. The price also includes the use of
sulphate resistant cement and other requirements as indicated
to soil report and durability requirements stated in spec item
(1.5).

5.03 Reinforced concrete of minimum characteristic cube strength


35 MPa {Equivalent cylinder strength 28 MPa} of minimum
ordinary portland cement content 400 kg/m3 of concrete as
approved by the Organization, excluding steel reinforcement

Rate per cubic meter


a. For pile caps 3
m NA
b. For Raft foundation 3
m 5335
c. For isolated footings 3
m 1400
d. For tie beams 3
m 295
e. Sump pits and trenches 3
m 585

5.04 Reinforced concrete of minimum characteristic cube strength


35 MPa {Equivalent cylinder strength 28 MPa} of minimum
3
ordinary portland cement content 400 kg/m of concrete,
using concrete with fly ash or alternatively GGBS or silica fume
as approved by the Organization, excluding steel reinforcement

Rate per cubic meter


a. For pile caps 3
m NA
b. For Raft foundation 3
m NA
c. For isolated footings 3
m NA
d. For tie beams 3
m NA
e. Sump pits and trenches 3
m NA

5.05 Reinforced concrete of minimum characteristic cube strength


35 MPa {Equivalent cylinder strength 28 MPa} of minimum
3
sulphate resistant cement content 400 kg/m of concrete as
approved by the Organization, excluding steel reinforcement
Rate per cubic meter
a. For pile caps 3
m NA
b. For Raft foundation 3
m NA
c. For isolated footings 3
m NA
d. For tie beams 3
m NA
e. Sump pits and trenches 3
m NA
Total to Collection

Page 6 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

5.06 Reinforced concrete of minimum characteristic cube strength


25 MPa {Equivalent cylinder strength 20 MPa} of minimum
3
ordinary portland cement content 350 kg/m of concrete,
item shall include using of steel reinforcing fibers with
minimum content 25 kg/m3 , and all types of joints as
mentioned in drawings
Rate per square meter
a. Slab on grade with thickness 200 mm 2
m 17800
b. Slab on grade with thickness 150 mm 2
m NA

5.07 Reinforced concrete of minimum characteristic cube strength


25 MPa {Equivalent cylinder strength 20 MPa} of minimum
3
sulphate resistant cement content 350 kg/m of concrete,
item shall include using of steel reinforcing fibers with
minimum content 25 kg/m3 , and all types of joints as
mentioned in drawings
Rate per square meter
a. Slab on grade with thickness 200 mm 2
m NA
b. Slab on grade with thickness 150 mm 2
m NA

5.08 Reinforced concrete of minimum characteristic cube strength


40 MPa {Equivalent cylinder strength 32 MPa} of minimum
3
ordinary portland cement content 460 kg/m of concrete,
excluding steel reinforcement.
Rate per cubic meter
a. For columns 3
m 1950
b. For slabs 3
m 6000
c. For slabs on corrugated sheets 3
m 335
d. For stairs 3
m 490
e. For parapets 3
m 465
f. For shear walls and cores 3
m 1370
g. For beams and frames 3
m 1145
h. For retaining walls 3
m 1130

5.08.a Reinforced concrete of minimum characteristic cube strength


40 MPa {Equivalent cylinder strength 32 MPa} of minimum
3
ordinary portland cement content 420 kg/m of concrete,
excluding steel reinforcement.
Rate per cubic meter
a. For columns 3
m NA
b. For slabs 3
m NA
c. For slabs on corrugated sheets 3
m NA
d. For stairs 3
m NA
e. For parapets 3
m NA
f. For shear walls and cores 3
m NA
g. For beams and frames 3
m NA
h. For retaining walls 3
m NA

Total to Collection
Page 7 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
5.09 Reinforced concrete of minimum characteristic cube strength
40 MPa {Equivalent cylinder strength 32 MPa} of minimum
3
sulphate resistant cement content 460 kg/m of concrete,
excluding steel reinforcement.
Rate per cubic meter
a. For columns 3
m NA
b. For slabs 3
m NA
c. For slabs on corrugated sheets 3
m NA
d. For stairs 3
m NA
e. For parapets 3
m NA
f. For shear walls and cores 3
m NA
g. For beams and frames 3
m NA
h. For retaining walls 3
m NA

5.09.b Reinforced concrete of minimum characteristic cube strength


40 MPa {Equivalent cylinder strength 32 MPa} of minimum
3
sulphate resistant cement content 420 kg/m of concrete,
excluding steel reinforcement.
Rate per cubic meter
a. For columns 3
m NA
b. For slabs 3
m NA
c. For slabs on corrugated sheets 3
m NA
d. For stairs 3
m NA
e. For parapets 3
m NA
f. For shear walls and cores 3
m NA
g. For beams and frames 3
m NA
h. For retaining walls 3
m NA

5.10
Supply and install of steel reinforcement. Rate includes supply
of materials, cutting, shaping, assembly, installation, splicing,
losses, chairs binding wire, testing and all other expenses
required to comply with the specifications. (Including steel
reinforcement for all RC elements).
Rate per ton
a. Steel Fy =500 MPA T 3075
Total to Collection

Page 8 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (05)

CONCRETE WORKS

Total of page 5

Total of page 6

Total of page 7

Total of page 8

Total to Summary

Page 9 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (06)

PRECAST CONCRETE WORKS


Reference is to be made to section (6) of Specifications.

N.B.: Rates of precast concrete works include all expenses


related to the supply of materials, labour, plant, equipment,
mixes design .mixing, scaffolding, installation and dismantling
of forms, placement, construction joints, curing, testing, site
laboratory, admixtures (additives such as plasticizer) and all
required to conform with drawings and specifications, and
satisfy contractual obligations . Rates excludes reinforcement
unless otherwise stated in item. The price also includes the use
of sulphate resistant cement and other requirements as
indicated to soil report and durability requirements stated in
spec item (1.5).
Precast reinforced concrete of minimum characteristic cube
strength 40 MPa {Equivalent cylinder strength 32 MPa} of
3
minimum ordinary portland cement content 460 kg/m of
6.01
concrete, using concrete with fly ash or alternatively GGBS or
silica fume as approved by the Organization, excluding steel
reinforcement. Include all materials used in fixation or joints
fillers
Rate per cubic meter
a. For columns (fair faced) 3
m NA
b. For slabs (fair faced) 3
m NA
c. For beams (fair faced) 3
m NA
d. For footings (fair faced) 3
m NA
e. For walls (fair faced) 3
m NA

Precast reinforced concrete of minimum characteristic cube


strength 40 MPa {Equivalent cylinder strength 32 MPa} of
3
minimum ordinary portland cement content 420 kg/m of
6.01.a concrete, using concrete with fly ash or alternatively GGBS or
silica fume as approved by the Organization, excluding steel
reinforcement. Include all materials used in fixation or joints
fillers
Rate per cubic meter
a. For columns (fair faced) 3
m NA
b. For slabs (fair faced) 3
m NA
c. For beams (fair faced) 3
m NA
d. For footings (fair faced) 3
m NA
e. For walls (fair faced) 3
m NA

Total to Collection

Page 10 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
Precast reinforced concrete of minimum characteristic cube
strength 40 MPa {Equivalent cylinder strength 32 MPa} of
3
minimum sulphate resistant cement content 460 kg/m of
6.02
concrete, using concrete with fly ash or alternatively GGBS or
silica fume as approved by the Organization, excluding steel
reinforcement. Include all materials used in fixation or joints
fillers
Rate per cubic meter
a. For columns (fair faced) 3
m NA
b. For slabs (fair faced) 3
m NA
c. For beams (fair faced) 3
m NA
d. For footings (fair faced) 3
m NA
e. For walls (fair faced) 3
m NA

Precast reinforced concrete of minimum characteristic cube


strength 40 MPa {Equivalent cylinder strength 32 MPa} of
3
minimum sulphate resistant cement content 420 kg/m of
6.02.a
concrete, using concrete with fly ash or alternatively GGBS or
silica fume as approved by the Organization, excluding steel
reinforcement. Include all materials used in fixation or joints
fillers
Rate per cubic meter
a. For columns (fair faced) 3
m NA
b. For slabs (fair faced) 3
m NA
c. For beams (fair faced) 3
m NA
d. For footings (fair faced) 3
m NA
e. For walls (fair faced) 3
m NA

6.03 Precast reinforced concrete fence Item shall include


reinforcement, fabrication, installation and all necessary
works according to specifications, drawings and NAT/Engineer
approval.
a. For walls according to drawings m
2
2000
3
b. For columns (I-shape) m NA
c. For footings 3
m NA

Total to Collection

Page 11 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
6.04 Supply and install reinforcement precast concrete crash
barrier of minimum cube strength 40mpa including joint
treatment 300 kg cement per cubic meter of sand ( contractor
is to submit complete details of units and method of fixation to
rate per linear meter m NA

6.05 Precast prestressed beams grade 50 of minimum 28


characteristics cube strength 500kg/cm2 and cement content
550
Ratekg/m3.
per cubic meter m
3
NA

6.06 Supply and install of steel reinforcement and pre stressing


cables. Rate includes supply of materials, cutting, shaping,
assembly, installation, splicing, losses, chairs binding wire,
testing and all other expenses required to comply with the
specifications. (Including steel reinforcement for all RC
elements).
a. Steel reinforcement Fy =500 MPA T 27
b. Pre stressing cables (as per drawings and specifications) T NA
Total to Collection

Page 12 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (06)

PRECAST CONCRETE WORKS

Total of page 10

Total of page 11

Total of page 12

Total to Summary

Page 13 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
SECTION (08)

STRUCTURAL STEEL WORKS

Reference is to be made to section (8) of Specifications.

NB; (Rates include bolts, welding, anchor bolts and


cementitious grout. Painting is including unless it mentioned in
separately in item. Measurements shall be according to shop
drawings prepared by the Contractor and approved by the
Organization. No allowances are to be added to structural
steel weight for bolts, welding.... as their prices are included in
structural steel price. item rate include all test required in
specifications.
rate steel
also include grade (zinc
anti-rust wil beepoxy
according to approved
coating) design.
as per drawings
and specifications.
2
8.01 Structural Steel grade ST - 52 (Fy =3.60t/cm ) without fire

Rate per ton


400
a. Steel Sections T

Structural steel grade ST - 52 (Fy =3.60t/cm2) (painted with


8.02
fire resistant coating measured in items (8.07&8.08).

Rate per ton 960

a. Steel Sections T

2
8.03 Structural Steel grade ST - 37 (Fy =2.40t/cm ) without fire
resisting coating.
Rate per ton

a. External ,internal stairs T NA


b. Beams and girders T NA
f. Columns T NA

2
Structural Steel grade ST - 37 (Fy =2.40t/cm ) (painted with
8.04
fire resistant coating measured in items (8.07&8.08).

Rate per ton

a. External ,internal stairs T NA


b. Beams and girders T NA
f. Columns T NA

Galvanized corrugated steel sheets 1.0mm thick measured on


8.05
horizontal projection.

Rate per square meter

a. For external and internal stairs 2


m NA
b. For metal deck slab 2
m 2300

Total to Collection
Page 14 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
Supply and install of checkered plates for stairs (thickness will
be according to approved DWG) prepared for applying
8.06
adhesive for granite installation For external and internal stairs
(bottom of checkered plate to be coated with zinc epoxy 80
micron thick).
Rate per square meter 2
m NA

8.07 2
Structural Steel grade ST - 52 (Fy =3.60t/cm ) without fire
resisting coating.
for steel sheds above platforms (rate per ton) T NA

8.08 Supply & install of ball joints space truss . the price shall
include submit of the full detailed drawings, design calculation
of the space truss system and connections with concrete
columns , specs and method statement for review before
construction.
Rate per square meter 2
m NA

High density sprayed applied cementitious materials fire


8.09 coating (parts not exposed as specified in technical
specifications)
Rate per square meter / 1hr 2
m NA
Rate per square meter / 2hr 2
m NA

8.10 Intumescent coating for exposed steel structure as per


drawings and specifications.
Rate per square meter / 1hr 2
m NA
Rate per square meter / 2hr 2
m 4900
Total to Collection

Page 15 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (08)

STRUCTURAL STEEL WORKS

Total of page 14

Total of page 15

Total to Summary

Page 16 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
SECTION (10)

DAMP AND WATERPROOFING

Reference is to be made to section (10) of Specifications

Vapour barrier of polyethylene film 400 micron thick, under


10.01
slab on grade.

Rate per square meter 2


m 17800

Cold applied Bitumen rubberized Coating (3 layers) including


10.02 protection of works according to section (10) of specification
as per drawings.

Rate per square meter 2


m 23600

Styrene-Butadiene-Styrene (SBS) Modified Bituminous Sheet


10.03 Waterproofing including protection of works according to
section (10) of specification as per drawings.

Rate per square meter 2


m 6500

Crystalline cement waterproofing including protection of


10.04 works according to section (10) of specification as per
drawings.

Rate per square meter 2


m NA

10.5 Geotextile sheet of density 350kg/m3

Rate per square meter 2


m NA
Total to Collection

Page 17 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (10)

DAMP AND WATERPROOFING

Total of page 17

Total to Summary

Page 18 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
SECTION (17)

Concrete Work For Arrangement


N.B.: Rates comprise all expenses related to the supply of
materials, labor, plant, equipment, mixes design, mixing
scaffolding, installation and dismantling of forms, use of
special forms to produce fair face concrete for exposed
surface, epoxy paint water proofing, screed for slopes,
placement, construction joints, curing, testing, site laboratory,
steel reinforcement and forming any required grooves, gutters
for electromechanical and sanitary work all required to
conform with drawings & Specifications, Section (17).

Screeds
17.01 Fiber Reinforced Screed, with required thickness, Refer Floor
M2 24223
Finishes, compressive strength between 20-25 Mpa.

17.02 Plain concrete for roofs, grade 20 of minimum 28 days,


2
characteristic strength = 20 N/mm and minimum cement
3
content = 300 kg/ m with inclination for drainage of 7 cm
average thickness.
a. For station M2 6566
b. For Platform Sheds at Platform level M2 2528

17.03 Plain concrete for Platform, grade 20 of minimum 28 days,


2
characteristic strength = 20 N/mm and minimum cement
3
M2 12000
content = 300 kg/ m with inclination for drainage of 10 cm
average thickness.

Precast Architectural Concrete


17.04 Concrete Paving , Portland Cement Concrete (PCC) M2 N/A

17.05 Concrete Car Stopper, Ref. Det.11/AE591 U N/A


Total to Collection

Page 19 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (17)

Concrete Work For Arrangement

Total of page 19

Total to Summary

Page 20 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (02)

MASONRY

N.B.: Rates comprise the supply and laying of bricks, mortar,


dovetail metal joints, bar grooving and pointing of external
exposed surfaces and facings links all in accordance with
Specifications, Section (02).
Masonry
2.01 Solid concrete brick wall 10 cm thick.
(WC01), Non-Fire rated M2 1300
(WC02), 1hr Fire rated M2 167

2.02 Solid concrete brick wall 20 cm thick.


(WC03), Non-Fire rated M2 6894
(WC04), 1hr Fire rated M2 6873
(WC05), 2hr Fire rated M2 920

2.03 Solid concrete brick wall 30 cm thick.


(WC10), Non-Fire rated M2 5718
(WC11), 1hr Fire rated M2 4928
(WC12), 2hr Fire rated M2 79

2.04 Hollow concrete brick wall 30 cm thick.


(WC09), 1hr Fire rated M2 140
Total to Collection

Page 21 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (02)

MASONRY

Total of page 21

Total to Summary

Page 22 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (03)

Damp And Waterproofing


N.B.: Rates comprise the supply and installation of
waterproofing layers, applications of coatings, screeds,
protective boards as required all in accordance with
Specifications, Section (03).
3.01 Bituminous Membrane Roofing
Two layers of torch applied bituminous waterproofing
membrane of 4mm thick each, in accordance with
Specifications.
a. For Toilets M2 725
b. For Roof M2 6566
Total to Collection

Page 23 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (03)

Damp And Waterproofing

Total of page 23

Total to Summary

Page 24 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
SECTION (04)

THERMAL INSULATION
4.01 Supply and installation of thermal insulation for roofing
consisting of extruded polystyrene board 50mm thick and a
M2 6566
polyethylene sheet 400 micron thick, in accordance with
Specifications, Section (04).
4.02 Thermal Insulation Board 50 mm thick Mineral Wool behind
spandrel panels, External stone claddings, and/or inbetween
M2 10223
External cavity walls where required and as specified in
drawings and Tech. specifications
Total to Collection

Page 25 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (04)

THERMAL INSULATION

Total of page 25

Total to Summary

Page 26 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.
SECTION (17)

Concrete Work For Arrangement


N.B.: Rates comprise all expenses related to the supply of
materials, labor, plant, equipment, mixes design, mixing
scaffolding, installation and dismantling of forms, use of
special forms to produce fair face concrete for exposed
surface, epoxy paint water proofing, screed for slopes,
placement, construction joints, curing, testing, site laboratory,
steel reinforcement and forming any required grooves, gutters
for electromechanical and sanitary work all required to
conform with drawings & Specifications, Section (17).

Screeds
17.01 Fiber Reinforced Screed, with required thickness, Refer Floor
M2 24223
Finishes, compressive strength between 20-25 Mpa.

17.02 Plain concrete for roofs, grade 20 of minimum 28 days,


2
characteristic strength = 20 N/mm and minimum cement
3
content = 300 kg/ m with inclination for drainage of 7 cm
average thickness.
a. For station M2 6566
b. For Platform Sheds at Platform level M2 2528

17.03 Plain concrete for Platform, grade 20 of minimum 28 days,


2
characteristic strength = 20 N/mm and minimum cement
3
M2 12000
content = 300 kg/ m with inclination for drainage of 10 cm
average thickness.

Precast Architectural Concrete


17.04 Concrete Paving , Portland Cement Concrete (PCC) M2 N/A

17.05 Concrete Car Stopper, Ref. Det.11/AE591 U N/A


Total to Collection

Page 27 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

SECTION (17)

Concrete Work For Arrangement

Total of page 27

Total to Summary

Page 28 of 29
CLIENT : NATIONAL AUTHORITY FOR TUNNELS
PROJECT : EETS - ELECTRICAL EXPRESS TRAIN STATIONS
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
NOTE
EGP. EGP.

TOTAL SUMMARY PAGE FOR ALL SECTIONS

EARTH WORK

CONCRETE WORKS

PRECAST CONCRETE WORKS

STRUCTURAL STEEL WORKS

MASONRY

DAMP AND WATERPROOFING

THERMAL INSULATION

Concrete Work For Arrangement

TOTAL

Page 29 of 29

You might also like