You are on page 1of 102

operator’s

guide
CPAS-3000 V2.7
Data Loader

Export Control Classification Notice (ECCN) for this document is 7E994.


For product orders or inquiries, please contact:

Rockwell Collins
Customer Response Center
400 Collins Rd NE M/S 133-100
Cedar Rapids, IA 52498-0001

TELEPHONE: 1.888.265.5467
INTERNATIONAL: 1.319.265.5467
FAX NO: 1.319.295.4941
EMAIL: response@rockwellcollins.com

© Copyright 2008 Rockwell Collins, Inc. All rights reserved.

Printed in the USA

SOFTWARE COPYRIGHT NOTICE


© Copyright 2003–2008 Rockwell Collins, Inc. All rights reserved.
All software resident in the equipment covered by this publication is
protected by copyright.

REGISTERED TRADE MARKS


® Microsoft, Windows, Windows 95, Windows 98, Windows 2000,
Windows ME, Windows NT and Windows XP are registered trade
marks of Microsoft.
CPAS-3000 Data Loader OPERATOR’S GUIDE
Data Loading Software For Windows Table of Contents

TABLE OF CONTENTS
Tab Title Page

1 INTRODUCTION
List of Acronyms and Abbreviations .................................... 1- 1

2 OVERVIEW
Introduction .......................................................................... 2- 1

3 SYSTEM REQUIREMENTS
Introduction .......................................................................... 3- 1
Items Needed to Install/Use the CPAS-3000 ....................... 3- 2

4 SETUP
Introduction .......................................................................... 4- 1
Installing the CPAS-3000 Data Loader ................................ 4- 1
Uninstalling the CPAS-3000 Data Loader ............................ 4- 2

5 UNLOCKING THE SOFTWARE


Unlock Software Window ..................................................... 5- 1

6 SELECTING PC NETWORK ADAPTER


Introduction .......................................................................... 6- 1
Select the Dataload Network Adapter Window .................... 6- 1
Configure Dataload Network Adapter Settings Win-
dow ...................................................................................... 6- 2

7 QUICK START
Introduction .......................................................................... 7- 1
Uploading Data/Software to an LRU ................................... 7- 1
Downloading Data/Software from an LRU ........................... 7- 3
Importing Data/Software ...................................................... 7- 4

8 PROGRAM LIMITATIONS
CPAS-3000 Data Loader Limitations ................................... 8- 1

9 PROGRAM OPERATION
Introduction .......................................................................... 9- 1
CPAS-3000 Launch Pad Window ........................................ 9- 1
Network Connections Detected Window ............................. 9- 2
Starting CPAS-3000 Window ............................................... 9- 4
Exiting CPAS-3000 Window ................................................ 9- 5
Quick Start Checklist Window ............................................. 9- 6

2nd Edition
6 Jun 08 i
OPERATOR’S GUIDE CPAS-3000 Data Loader
Table of Contents Data Loading Software For Windows

Tab Title Page


CPAS-3000 Data Loader Window ....................................... 9- 8
Load Direction .................................................................. 9- 9
Acquire/Refresh Targets .................................................. 9-10
Select Target/LRU to be Updated .................................... 9-10
Select Data/Software to be Updated ................................ 9-11
Load From ........................................................................ 9-13
Begin Load ....................................................................... 9-13
Status Tabs ...................................................................... 9-14
Show Detailed Information ............................................... 9-17
Check Integrity of Selected Data/Software ...................... 9-18
Optional Pop-Up Windows ............................................... 9-19
Manage Data/Software Window .......................................... 9-21
Remove ............................................................................ 9-22
Import ............................................................................... 9-23
Check Integrity ................................................................. 9-27
Refresh ............................................................................ 9-28
Advanced ......................................................................... 9-29
Close ................................................................................ 9-32
Requesting 615A Target ...................................................... 9-32
Data Loader Configuration Window ..................................... 9-33
General ............................................................................ 9-34
Logging ............................................................................ 9-37
Restore Defaults .............................................................. 9-38
Advanced ......................................................................... 9-38
Help Information ............................................................... 9-53
Support Information ............................................................. 9-53

10 TROUBLESHOOTING
Introduction ........................................................................ 10- 1
CPAS-3000 Data Loader Installation Fails ........................ 10- 1
Insufficient Hard Drive Memory ...................................... 10- 1
Unable to Register the COM Objects ............................. 10- 1
No Targets Available to Update ......................................... 10- 1
Target/LRU Missing From the Update List ......................... 10- 2
Installed Data/Software Not Shown .................................. 10- 3
Unable to Import a Data/Software Item ............................. 10- 3
Data/Software Not Shown ............................................. 10- 4
Error Occurred During the Import .................................. 10- 4
Data/Software Fails an Integrity Check .......................... 10- 5
Dataload Failure Encountered ........................................... 10- 5
File Missing .................................................................... 10- 5
Timeout/Counter Error ................................................... 10- 6

2nd Edition
ii 6 Jun 08
CPAS-3000 Data Loader OPERATOR’S GUIDE
Data Loading Software For Windows Table of Contents

Tab Title Page


Communication/Transmission Error ............................... 10- 6
Load Aborted ..................................................................... 10- 7
Wireless or Local Area Connections Not Working ............. 10- 7
Other Notes ....................................................................... 10- 7

INDEX .............................................................................. Index- 1

2nd Edition
6 Jun 08 iii
OPERATOR’S GUIDE CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
iv 6 Jun 08
CPAS-3000 Data Loader OPERATOR’S GUIDE
Data Loading Software For Windows List of Illustrations

LIST OF ILLUSTRATIONS
Figure Title Page

3-1 FSU Setup .......................................................................... 3- 2


5-1 Unlock Software Window .................................................... 5- 1
6-1 Select the Dataload Network Adapter Window ................... 6- 2
6-2 Configure Dataload Network Adapter Settings Win-
dow ..................................................................................... 6- 3
9-1 CPAS-3000 Launch Pad Window ....................................... 9- 2
9-2 Network Connections Detected Window ............................ 9- 3
9-3 Starting CPAS-3000 Window .............................................. 9- 4
9-4 Reboot PC Window (start up) ............................................. 9- 4
9-5 Exiting CPAS-3000 Window (no network adapter
changes) ............................................................................. 9- 5
9-6 Exiting CPAS-3000 Window (with network adapter
changes) ............................................................................. 9- 5
9-7 Reboot PC Window (Exiting) .............................................. 9- 6
9-8 Quick Start Checklist .......................................................... 9- 7
9-9 CPAS-3000 Data Loader Window ...................................... 9- 9
9-10 Load Direction Buttons ....................................................... 9- 9
9-11 Acquire/Refresh Targets ..................................................... 9-10
9-12 Select Target/LRU to be Updated Window ......................... 9-11
9-13 Select Data/Software to be Updated Window .................... 9-12
9-14 Load From Hard Drive Button ............................................. 9-13
9-15 Begin Load Button .............................................................. 9-13
9-16 Begin Load Grayed ............................................................. 9-14
9-17 Status Window .................................................................... 9-14
9-18 Status Window with Error Icon ........................................... 9-16
9-19 Load Failed Window ........................................................... 9-17
9-20 Show Detailed Information Window .................................... 9-18
9-21 Check Integrity Window ...................................................... 9-18
9-22 Acquire/Refresh Targets ..................................................... 9-20
9-23 Query Completes ................................................................ 9-20
9-24 Query Reply ........................................................................ 9-21
9-25 Manage Data/Software Window ......................................... 9-22
9-26 Select Data/Software to Import Window ............................. 9-24
9-27 Select a Directory ............................................................... 9-25
9-28 Importing Data/Software Window ....................................... 9-26
9-29 Check Integrity Window ...................................................... 9-28
9-30 Data/Software Properties ................................................... 9-30
9-31 615A Properties .................................................................. 9-31

2nd Edition
6 Jun 08 v
OPERATOR’S GUIDE CPAS-3000 Data Loader
List of Illustrations Data Loading Software For Windows

Figure Title Page


9-32 615A Target Information Window ....................................... 9-33
9-33 Data Loader Configuration Window .................................... 9-34
9-34 Edit Target Support Information .......................................... 9-36
9-35 Support Information ............................................................ 9-37
9-36 Configuration Window: FSU Tab ........................................ 9-40
9-37 Configuration Window: 615A Tab ....................................... 9-43
9-38 Configuration Window: DBU Tab ........................................ 9-45
9-39 Configuration Window: 615-3 Tab ...................................... 9-47
9-40 Configuration Window: Network Tab .................................. 9-50
9-41 Configuration Window: IOC Tab ......................................... 9-52

2nd Edition
vi 6 Jun 08
CPAS-3000 Data Loader INTRODUCTION
Data Loading Software For Windows List of Acronyms and Abbreviations

INTRODUCTION
This operator’s guide applies to Rockwell Collins CPAS-3000 Data
Loader, Version 2.7. The guide will be revised as other functions
become available in the future.
The software installation procedures located in the Setup topic of this
guide are a one-time install procedure. Once installed, the Data Loader
program remains on the Personal Computer’s (PC) hard drive until the
user removes it via the uninstall procedure.

To submit comments regarding this manual, please contact:

Rockwell Collins Services


350 Collins Rd NE
Cedar Rapids, IA 52498-0001

Attn: Technical Operations M/S 153-250

or send email to: techmanuals@rockwellcollins.com

LIST OF ACRONYMS AND ABBREVIATIONS


ARINC Aeronautical Radio, Inc.
COTS Commercial Off The Shelf
CPAS Collins Portable Access Software
CPN Collins Part Number
DBU Data Base Unit
FIND Find Identification of Network Devices
FMC Flight Management Computer
FSU File Server Unit
ID Identification
IOC Input Output Concentrator
IP Internet Protocol
LAN Local Area Network
LRU Line Replaceable Unit
MDC Maintenance Diagnostic Computer
MTU Maximum Transmission Unit
PC Personal Computer
PCMCIA Personal Computer Memory Card Interface
Association

2nd Edition
6 Jun 08 1-1
INTRODUCTION CPAS-3000 Data Loader
List of Acronyms and Abbreviations Data Loading Software For Windows

SNIP Simple Network Identification Protocol


TFTP Trivial File Transfer Protocol
VPN Virtual Private Network

2nd Edition
1-2 6 Jun 08
CPAS-3000 Data Loader OVERVIEW
Data Loading Software For Windows Introduction

OVERVIEW

INTRODUCTION
The Collins Portable Access Software (CPAS) Data Loader is a
software application that provides external media upload and download
capabilities to Ethernet based Line Replaceable Units (LRU), like
Rockwell Collins’ File Server Unit (FSU). The FSU provides the added
capability to allow uploads and downloads to other LRUs, like the Flight
Management Computer (FMC) and Maintenance Diagnostic Computer
(MDC), which are attached to the FSU. The CPAS Data Loader is
designed for use on a standard Windows-based PC with Ethernet
capability.
Overview of File Server Unit (FSU)
The FSU is part of Rockwell Collins’ Pro Line 21 Continuum architecture
that provides an advanced, highly integrated cockpit environment.
The FSU provides the storage and processing platform for advanced
features, like electronic airport and procedure charts, up-linked
graphical weather and enhanced map overlays.
The FSU provides data load connectivity to other Rockwell Collins’ Pro
Line 21 and Pro Line 4 LRUs, like the FMC, the MDC and Aeronautical
Radio, Inc (ARINC) 429 based LRUs. These LRUs are loaded over
the same Ethernet connection that is used to load the FSU. Thus, the
CPAS-3000 supports loading of all (aircraft loadable) LRUs using the
same user interface and a single Ethernet connection, while relieving
the operator of having to understand what data load type corresponds
to what LRU.
Overview of Data Load Types
The CPAS-3000 automatically manages the type of data loads and
only provides a list of data and software loads that are appropriate for
the selected target or LRU. This alleviates the operator from having to
understand and manage the different data load types. The following
paragraphs provide an overview of the various data load types that
CPAS supports.
The CPAS supports ARINC 615A loads for Ethernet based LRUs,
like the FSU. ARINC 615A loads must be formatted per ARINC 665
standards. The CPAS does not support ARINC 615A download
capabilities.

2nd Edition
6 Jun 08 2-1
OVERVIEW CPAS-3000 Data Loader
Introduction Data Loading Software For Windows

When connected to the FSU, the CPAS also supports ARINC 615-3
loads for ARINC 429 based LRUs and Rockwell Collins proprietary
RS-422 DBU (Data Base Unit) based loads to the FMC and MDC. The
CPAS does not support ARINC 615-3 download capabilities.
The CPAS supports two types of RS-422 DBU based loads, normal
DBU mode and enhanced DBU mode. Normal DBU mode functions
similar to a normal DBU – once the data load has been started on the
CPAS, the operator must then initiate the actual upload or download
operation through the appropriate FMC or MDC interface. In enhanced
DBU mode, the CPAS can initiate the actual upload or download,
thereby bypassing any required interaction through the FMC or MDC
interface. If a FMC or MDC does not support enhanced DBU mode,
CPAS will revert back to normal DBU mode, which is supported by all
FMCs and MDCs. CPAS will prompt the operator (through a message
in the status window) when FMC or MDC interaction is necessary.
On some aircraft that contain an Avionics System Local Area Network
(LAN), the CPAS also supports ARINC 615-3 loads for ARINC 429
based LRUs over the Avionics System LAN. On these aircraft, the
ARINC 429 based LRUs are connected to a data load switch attached
to an Input/Output Concentrator (IOC) that is connected to the Avionics
System LAN.

2nd Edition
2-2 6 Jun 08
CPAS-3000 Data Loader SYSTEM REQUIREMENTS
Data Loading Software For Windows Introduction

SYSTEM REQUIREMENTS

INTRODUCTION
The Rockwell Collins CPAS-3000 Data Loader is designed to run on a
system with the following minimum requirements:

DESCRIPTION REQUIREMENT
PC or Laptop A PC with at least a 1 GHz 32-bit (x86)
Computer processor (or equivalent), 512 Mbyte RAM and
20 Gbyte hard drive. The PC must be running
the Windows 2000, Windows XP, or Windows
Vista operating system.

NOTE
N
CPAS-3000 will NOT run on Windows
95, Windows 98, Windows ME, or
Windows NT.
The PC must have Ethernet capability, which
may be built into the PC or may be an installed
Customer Off The Shelf (COTS) Ethernet
Personal Computer Memory Card Interface
Association (PCMCIA) card. The Ethernet
hardware must support 100 Base T.

NOTE
N
Installation of the CPAS-3000 requires
administrator rights.

NOTE
N
It is recommended that the CPAS-3000
users have administrator rights (or
at least rights to modify the network
parameters and enable/disable the
network adapter). Otherwise the PC will
require a reboot at startup and exit of the
CPAS-3000 Data Loader program.

2nd Edition
6 Jun 08 3-1
SYSTEM REQUIREMENTS CPAS-3000 Data Loader
Items Needed to Install/Use the CPAS-3000 Data
Loading Software For Windows

ITEMS NEEDED TO INSTALL/USE THE


CPAS-3000
The following table describes the items needed to install and use the
Rockwell Collins CPAS-3000 Data Loader.

QUANTITY DESCRIPTION
1 CPAS-3000 Data Loader Software
Package (CPN 810-0032-004),
which includes the following items:
•Install CD contains the Rockwell
Collins CPAS-3000 Launch Pad
and Data Loader software V2.7.
•CPAS-3000 Data Loader operator’s
guide.
1 Ethernet cable with RJ-45 connectors:
•Refer to the aircraft manual to determine
proper cable type (i.e., Standard or crossover
cable) to be used.

Refer to the aircraft manual for instructions on how and where to


connect the CPAS-3000 PC. The following illustration provides an
example of how the FSU could be connected (Figure 3-1).

Figure 3-1 FSU Setup

2nd Edition
3-2 6 Jun 08
CPAS-3000 Data Loader SYSTEM REQUIREMENTS
Data Loading Software For Windows Items
Needed to Install/Use the CPAS-3000

CAUTION
C
If using an Ethernet switch to connect the CPAS-3000 to multiple
Ethernet based LRU’s (like the FSU), the ports on the switch must
be configured for 100 Base T and full duplex mode before the Data
Loader application will function properly. Refer to the Ethernet
switch documentation for further information on configuring the
switch.

2nd Edition
6 Jun 08 3-3
SYSTEM REQUIREMENTS CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
3-4 6 Jun 08
CPAS-3000 Data Loader SETUP
Data Loading Software For Windows Introduction

SETUP

INTRODUCTION
The following paragraphs provide the procedures to install the Rockwell
Collins CPAS-3000 Data Loader onto the PC and to uninstall the Data
Loader from the PC.

INSTALLING THE CPAS-3000 DATA LOADER


Use the following procedure to install the Data Loader software onto
the PC.
NOTE
N
Administrator rights are required to install the CPAS-3000 Data
Loader software. Previous versions of CPAS-3000 Data Loader
software must be uninstalled before installing a newer version of
CPAS-3000 Data Loader software. Refer to UNINSTALLING THE
CPAS-3000 DATA LOADER for uninstall instructions.

1. Turn on the PC. Let the PC boot up.


2. Insert the CPAS-3000 Data Loader CD into the CD drive.
3. If the installation program doesn’t start automatically, click the
START button on the taskbar. Click RUN. Type in D:/Setup and click
OK. (If the PC CD drive letter is other than D, use the applicable
drive letter instead of D.)
4. Follow the instructions on the screen to perform the Rockwell Collins
CPAS-3000 Data Loader installation.
5. If virus protection software appears to be running, a window will be
displayed indicating the virus protection software detected. Disable
the virus protection software and click OK to continue with the
installation. For information on how to disable the virus protection
software, refer to the virus protection software documentation.
6. If this is the first time the CPAS-3000 Data Loader software is
installed on the PC, the UNLOCK SOFTWARE window will be
displayed. A software unlock key must be entered to activate the
Data Loader software. Refer to the Unlock Software Window section
for more information.

2nd Edition
6 Jun 08 4-1
SETUP CPAS-3000 Data Loader
Uninstalling the CPAS-3000 Data Loader Data Loading Software For Windows

7. If prompted, select the PC network adapter to be used by the


CPAS-3000 Data Loader. Refer to the Selecting the PC Network
Adapter section for more information.
Installation is complete. The Data Loader is now ready to use. To
start the Data Loader, double click on the LAUNCH PAD icon that was
created during the install and is now present on your desktop. Then
simply double click on the DATA LOADER button.

UNINSTALLING THE CPAS-3000 DATA LOADER


The Data Loader remains on the PC hard drive until the user wants to
remove it. Use the following procedure to uninstall the Data Loader
from the PC.
1. Turn on the PC. Let the PC boot up.
2. Click START. Select SETTINGS, then click on CONTROL PANEL.
Removal is performed through ADD/REMOVE PROGRAMS.
3. Select Program CPAS-3000 Dataload from list.
4. Click the Uninstall/Change or Change/Remove button. Follow
uninstall instructions.

2nd Edition
4-2 6 Jun 08
CPAS-3000 Data Loader UNLOCKING THE SOFTWARE
Data Loading Software For Windows Unlock Software Window

UNLOCKING THE SOFTWARE

UNLOCK SOFTWARE WINDOW


The UNLOCK SOFTWARE window (Figure 5-1) is displayed during
software installation time or on application startup if a valid software key
has not been entered. This window allows the software unlock key to be
entered, enabling the CPAS-3000 Data Loader application to be used.
This window will be shown if a software unlock key has not been entered
or if the software unlock key is determined to be invalid for this system.

Figure 5-1 Unlock Software Window

You must provide the software serial number and system id to Rockwell
Collins Technical Support in order to receive your software unlock key.
The software serial number and system id will be displayed in the fields
as shown above. If the software serial number field is blank, enter the
Software Serial Number from your CPAS-3000 software CD.

2nd Edition
6 Jun 08 5-1
UNLOCKING THE SOFTWARE CPAS-3000 Data Loader
Unlock Software Window Data Loading Software For Windows

After receiving your software unlock key from Rockwell Collins Technical
Support, enter the key in the field and click UNLOCK. If the software
determines the key is valid, it will launch the Data Loader application.
If you do not have a software unlock key, you can click the EXIT button
to exit the application.

2nd Edition
5-2 6 Jun 08
CPAS-3000 Data Loader SELECTING PC NETWORK ADAPTER
Data Loading Software For Windows Introduction

SELECTING PC NETWORK ADAPTER

INTRODUCTION
For the Data Loader to properly communicate with the FSU or other
Ethernet based LRUs, the Internet Protocol (IP) address, subnet
mask, MTU size, connection speed, and duplex mode of the Ethernet
network connection must be properly configured. The Data Loader will
automatically configure the network adapter on application startup and
restore the network adapter to its original configuration upon application
exit.
In order to provide this capability, the installation program attempts
to automatically select the Local Area Connection network adapter
and determine the appropriate configuration settings during software
installation. If a Local Area Connection is not detected, the installation
program selects the first available network adapter, excluding Wireless
and 1394 (FireWire) network connections. If multiple Local Area
Connection entries are detected, the user will be prompted to manually
select the PC network adapter and appropriate configuration settings
that will be used by the Data Loader.
NOTE
N
The selected network adapter can be viewed and changed from the
Network tab of the Data Loader advanced configuration settings.
Refer to the Network Tab under the Advanced section of the Data
Loader Configuration Window topic for information on viewing and
changing the network parameters.

SELECT THE DATALOAD NETWORK ADAPTER


WINDOW
The SELECT THE DATALOAD NETWORK ADAPTER window (Figure
6-1) allows the user to select the network adapter to be used by the
Data Loader. Select the appropriate network adapter card from the list
provided and click the OK button.

2nd Edition
6 Jun 08 6-1
SELECTING PC NETWORK ADAPTER CPAS-3000 Data Loader
Configure Dataload Network Adapter Settings Window Data
Loading Software For Windows

Figure 6-1 Select the Dataload Network Adapter Window

CONFIGURE DATALOAD NETWORK ADAPTER


SETTINGS WINDOW
The CONFIGURE DATALOAD NETWORK ADAPTER SETTINGS
window (Figure 6-2) is displayed after the network adapter has been
selected. Since every network adapter uses different properties and
values for specifying the speed and duplex settings, the correct values
to be used cannot always be automatically determined. Thus the user
is required to verify that the selected settings are correct.
Verify that the selected speed and duplex settings are set to 100
Base T and full duplex and click OK. If this is not the case, select the
correct settings and click OK. Refer to the text on the window for more
information on specifying the correct speed and duplex settings.
NOTE
N
The values listed in the SELECT PROPERTY FOR SPEED AND
DUPLEX and SELECT SETTING FOR 100 BASE T SPEED &
FULL DUPLEX boxes will probably be different than the values
displayed in Figure 6-2.

2nd Edition
6-2 6 Jun 08
CPAS-3000 Data Loader SELECTING PC NETWORK ADAPTER
Data Loading Software For Windows Configure
Dataload Network Adapter Settings Window

Figure 6-2 Configure Dataload Network Adapter Settings Window

2nd Edition
6 Jun 08 6-3
SELECTING PC NETWORK ADAPTER CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
6-4 6 Jun 08
CPAS-3000 Data Loader QUICK START
Data Loading Software For Windows Introduction

QUICK START

INTRODUCTION
The procedures that follow outline the basics on uploading,
downloading, and importing data/software. All procedures assume that
the PC is running and that the CPAS-3000 Data Loader application has
been successfully installed. For additional information on these topics,
please refer to the applicable sections later in this Operator’s Guide.
NOTE
N
Multiple target LRUs can be loaded simultaneously by starting
multiple uploads or downloads using the following instructions. A
separate status tab will be created for each load.

NOTE
N
If the user does not have sufficient privileges to modify the
network parameters and enable/disable the network adapter (e.g.,
administrator rights), then the PC will require a reboot at startup and
exit of the CPAS-3000 Data Loader Program.

UPLOADING DATA/SOFTWARE TO AN LRU


An upload is defined as the transfer of data/software from the Data
Loader to a target/LRU.
NOTE
N
The following procedure assumes that a valid data/software item
has already been imported (if uploading from the hard drive).

2nd Edition
6 Jun 08 7-1
QUICK START CPAS-3000 Data Loader
Uploading Data/Software to an LRU Data Loading Software For Windows

CAUTION
C
Disable any internet security software for example, firewalls
and Virtual Private Network (VPN) software, before starting the
CPAS-3000. These programs can block the network traffic needed
to communicate with the LRUs. The firewall and VPN programs
should be re-enabled before the PC is connected to internet service
or office network.

1. Ensure the FSU or other Ethernet based LRU is operating and is


properly connected to the PC with the appropriate Ethernet cable.
2. Double click on the Launch Pad icon. Double click on the DATA
LOADER button to launch the application.
3. Select the load direction by clicking on the UPLOAD button.
4. Click on the ACQUIRE/REFRESH Targets button.
5. Select the desired target from the SELECT TARGET/LRU TO BE
UPDATED drop-down box. If there are no targets in the list, click
on the ACQUIRE/REFRESH Targets button. If there are still no
targets in the list, verify that the data load targets/LRUs are properly
connected to the network and repeat step 4.
6. Verify the drive that data/software will be uploaded from is displayed
next to the SELECT DATA/SOFTWARE TO BE UPDATED
drop-down box. If a different drive is desired, select VIEW and then
SELECT DRIVE from the menu bar. The SELECT DRIVE pop-up
window will display an item for the hard drive and items for each
available CD, DVD, and removable drive found on the PC. Select
the desired drive.
7. Select the desired data/software item from the SELECT
DATA/SOFTWARE TO BE UPDATED drop-down box.
8. Click on the BEGIN LOAD button.
The upload is now in progress. A tab displaying the status of the load
will appear in the Status area.
NOTE
N
If the FMC or MDC does not support the enhanced DBU mode,
the upload must be started through the appropriate FMC or MDC
interface. Refer to the appropriate FMC or MDC Operator’s Guide
for information on the keystrokes required to initiate the upload.

2nd Edition
7-2 6 Jun 08
CPAS-3000 Data Loader QUICK START
Data Loading Software For Windows Downloading Data/Software from an LRU

Upon completion of the upload, the text on the CANCEL UPLOAD


button will change to Close Status.
NOTE
N
If the FMC or MDC does not support the enhanced DBU mode, the
text on the CANCEL UPLOAD button will not automatically change
to Close Status. When the FMC or MDC interface used to start the
load indicates the load is complete, click on the CANCEL UPLOAD
button. The button text will then change to Close Status.

Click the CLOSE STATUS button to close the status tab for the
completed load. Select FILE and then EXIT from the menu bar, or click
the EXIT CPAS button to exit the CPAS-3000 Data Loader.

DOWNLOADING DATA/SOFTWARE FROM AN


LRU
A download is defined as the transfer of data/software from a target/LRU
to the Data Loader.
CAUTION
C
Disable any internet security software for example, firewalls
and Virtual Private Network (VPN) software, before starting the
CPAS-3000. These programs can block the network traffic needed
to communicate with the LRUs. The firewall and VPN programs
should be re-enabled before the PC is connected to internet service
or office network.

1. Ensure the FSU or other Ethernet based LRU is operating and is


properly connected to the PC with the appropriate Ethernet cable.
2. Double click on the LAUNCH PAD icon. Double click on the DATA
LOADER button to launch the application.
3. Select the load direction by clicking on the DOWNLOAD button.
4. Click on the ACQUIRE/REFRESH TARGETS button.
5. Select the desired target from the SELECT TARGET/LRU TO BE
UPDATED drop-down box. If there are no targets in the list, click
on the ACQUIRE/REFRESH TARGETS button. If there are still no
targets in the list, verify that the data load targets/LRUs are properly
connected to the network and repeat step 4.

2nd Edition
6 Jun 08 7-3
QUICK START CPAS-3000 Data Loader
Importing Data/Software Data Loading Software For Windows

6. To download data/software, select the desired data/software item


from the SELECT DATA/SOFTWARE TO BE UPDATED drop-down
box.
7. Click on the BEGIN LOAD button.
The download is now in progress. A tab displaying the status of the
load will appear in the Status area.
NOTE
N
If the FMC or MDC does not support the enhanced DBU mode, the
download must be started through the appropriate FMC or MDC
interface. Refer to the appropriate FMC or MDC Operator’s Guide
for information on the keystrokes required to initiate the download.

Upon completion of the download, the text on the CANCEL


DOWNLOAD button will change to Close Status.
NOTE
N
If the FMC or MDC does not support the enhanced DBU mode,
the text on the CANCEL DOWNLOAD button will not automatically
change to Close Status. When the FMC or MDC interface used to
start the load indicates the load is complete, click on the CANCEL
DOWNLOAD button. The button text will then change to Close
Status.

Click the CLOSE STATUS button to close the status tab for the
completed load. Select FILE and then EXIT from the menu bar or click
the EXIT CPAS button to exit the CPAS-3000 Data Loader.

IMPORTING DATA/SOFTWARE
NOTE
N
The CPAS does not need to be connected to the FSU or other
Ethernet capable LRUs in order to import data/software.

1. Double click on the LAUNCH PAD icon.


2. The MANAGE DATA/SOFTWARE window can be accessed
by either double clicking on the MANAGE DATA/SOFTWARE
button, or by double clicking on the DATA LOADER button to
launch the application and selecting FILE and then MANAGE
DATA/SOFTWARE from the DATA LOADER menu bar.

2nd Edition
7-4 6 Jun 08
CPAS-3000 Data Loader QUICK START
Data Loading Software For Windows Importing Data/Software

3. In the MANAGE DATA/SOFTWARE window, click on the IMPORT


button.
4. In the SELECT A DIRECTORY window, select the drive containing
the desired data/software from the DRIVES drop-down box.
5. Double click on a folder under the drive to display the directories
contained in that folder.
6. Select the folder containing the data/software item(s) to import and
click on the OK button. The data/software contained in the folder
will be displayed in the AVAILABLE DATA/SOFTWARE display area
of the SELECT DATA/SOFTWARE TO IMPORT window.
7. Click on the desired data/software item in the AVAILABLE
DATA/SOFTWARE display area to toggle the check box.
8. Click on the OK button to import the data/software item.
NOTE
N
See the Import section of the Manage Data/Software Window topic
for information on where the imported data/software item is stored
on the hard drive.

2nd Edition
6 Jun 08 7-5
QUICK START CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
7-6 6 Jun 08
CPAS-3000 Data Loader PROGRAM LIMITATIONS
Data Loading Software For Windows CPAS-3000 Data Loader Limitations

PROGRAM LIMITATIONS

CPAS-3000 DATA LOADER LIMITATIONS


The CPAS-3000 Data Loader is designed to transfer data/software,
with the following limitations:
• The CPAS-3000 will not run under the Windows 95, Windows 98,
Windows ME, or Windows NT operating system.
• Downloading data/software (from a target/LRU to the Data Loader) is
currently not supported for the 615A and 615-3 data load types.
• Only one upload from a CD-ROM may be performed at a time.
• Multiple loads can be performed simultaneously, but only a single
load can be performed for a given target (e.g., can load the navigation
database into all FMCs at the same time but cannot load both the
Charts and Enhanced Maps databases into the FSU at the same
time).
• The FSU and the LRUs attached to the FSU (i.e., FMCs, MDC
and 429-based LRUs) cannot be loaded simultaneously. Although
loads for the FSU and the LRUs attached to the FSU can be started
simultaneously, they will be loaded serially.
• The CPAS-3000 will store only one pilot route file, one disk route
file and one pilot waypoint file for each FMC. The CPAS-3000 will
store only one checklist file and one test and rigging file for the MDC.
CPAS will overwrite any of these downloaded files that may already
be stored in the \DBU\Output directory.
• Importing Navigation databases from floppy disk is not supported.
If a Navigation database is contained on floppy disks, it should be
ordered on a larger media type (e.g., CD-ROM) or electronically.
• Importing data/software with individual files split across media
members (floppy disk, CD-ROM, etc.) is not supported. If a file does
not fit on a single media member (e.g., floppy disk), it should be
ordered on a larger media type (e.g., CD-ROM) or electronically.
• If the user does not have sufficient rights to modify the network
parameters and enable/disable the network adapter (e.g.,
administrator rights), then the PC will require a reboot at startup and
exit of the CPAS-3000 Data Loader program.

2nd Edition
6 Jun 08 8-1
PROGRAM LIMITATIONS CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
8-2 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Introduction

PROGRAM OPERATION

INTRODUCTION
The CPAS-3000 Data Loader supports the following functions:
• Uploading data/software to the target LRU.
• Downloading data/software from the target LRU.
• Importing data/software into the PC.
• Removing data/software from the PC.
• Checking the integrity of data/software.
• Requesting 615A target information.
• Querying which targets are available for data loading (i.e.,
acquire/refresh targets).
NOTE
N
Multiple targets/LRUs can be loaded simultaneously by starting
multiple uploads or downloads using the instructions listed in the
Quick Start Section.

CPAS-3000 LAUNCH PAD WINDOW


The CPAS-3000 LAUNCH PAD window (Figure 9-1) is displayed
after double-clicking on the LAUNCH PAD icon on the desktop. The
LAUNCH PAD icon should be displayed on the desktop after the
CPAS-3000 Data Loader software has been installed. The Launch Pad
provides a starting point for launching the CPAS-3000 Data Loader
application and accessing data/software management features.

2nd Edition
6 Jun 08 9-1
PROGRAM OPERATION CPAS-3000 Data Loader
Network Connections Detected Window Data Loading Software For Windows

Figure 9-1 CPAS-3000 Launch Pad Window

When double clicked, the DATALOAD button launches the CPAS-3000


Data Loader application, displaying the CPAS-3000 DATA LOADER
window. The MANAGE DATA/SOFTWARE button launches the
CPAS-3000 Data Loader data/software management features
separately from the other Data Loader functions. When the
MANAGE DATA/SOFTWARE button is double clicked, the MANAGE
DATA/SOFTWARE window will be displayed.
NOTE
N
Only one instance of the CPAS-3000 Data Loader can be running
at one time. This includes any instance launched by double clicking
on the MANAGE DATA/SOFTWARE button.

To close the Launch Pad, click the EXIT button.

NETWORK CONNECTIONS DETECTED


WINDOW
The NETWORK CONNECTIONS DETECTED window (Figure 9-2) is
displayed on the Data Loader program startup when active wireless
or local area network connections, other than the network adapter
configured for loads, are detected (Figure 9-2). The window allows
disabling the active network connections during operation of the Data
Loader program, as they may inhibit the performance of CPAS-3000
dataloads.

2nd Edition
9-2 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Network Connections Detected Window

Figure 9-2 Network Connections Detected Window

Click the YES button to automatically disable the active network


connections. Disabled connections will be re-enabled when the Data
Loader program is exited.
NOTE
N
If the Data Loader program exits abnormally during operation,
restart the application and exit to re-enable the network connections.

To prevent disabling the active network connections, click the NO button.

2nd Edition
6 Jun 08 9-3
PROGRAM OPERATION CPAS-3000 Data Loader
Starting CPAS-3000 Window Data Loading Software For Windows

STARTING CPAS-3000 WINDOW


The STARTING CPAS-3000 window (Figure 9-3) is displayed when
the Data Loader program is initially launched. This window will be
removed after the network card is successfully configured for use by
the Data Loader.

Figure 9-3 Starting CPAS-3000 Window

If the network parameters are different than those required by the Data
Loader, then the original network parameters will be saved, the network
parameters will be updated to the appropriate values and the network
adapter will be reset. If the user does not have sufficient rights to update
the network adapter and enable/disable the network adapter, the user
will be prompted (Figure 9-4) to reboot the PC and restart CPAS-3000
before the Data Loader will function properly. Refer to the Network Tab
under the Advanced section of the Data Loader Configuration Window
topic for information on the network parameters.

Figure 9-4 Reboot PC Window (start up)

2nd Edition
9-4 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Exiting CPAS-3000 Window

EXITING CPAS-3000 WINDOW


The EXITING CPAS-3000 window (Figure 9-5) is displayed when the
Data Loader program is exited and no network adapter changes are
required for the dataload network adapter. This window will be removed
once the CPAS-3000 program has shut down.

Figure 9-5 Exiting CPAS-3000 Window (no network adapter changes)

If the Restore Original Network Adapters Parameters on Exit box on the


Network Tab is checked, then the EXITING CPAS-3000 window (Figure
9-6) is displayed when the Data Loader program is exited. This window
will be removed after the original network parameters (that were saved
at startup) are successfully restored and the network adapter is reset.

Figure 9-6 Exiting CPAS-3000 Window (with network adapter


changes)

If the user does not have sufficient rights to update the network adapter
and enable/disable the network adapter, the user will be prompted
(Figure 9-7) to reboot the PC before the PC will function properly. Refer
to the Network Tab under the Advanced section of the Data Loader
Configuration Window topic for information on the network parameters.

2nd Edition
6 Jun 08 9-5
PROGRAM OPERATION CPAS-3000 Data Loader
Quick Start Checklist Window Data Loading Software For Windows

Figure 9-7 Reboot PC Window (Exiting)

QUICK START CHECKLIST WINDOW


The Quick Start Checklist window (Figure 9-8) is displayed on
application startup (Figure 1-8). This window provides a checklist of
steps on how to start a load.

2nd Edition
9-6 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Quick Start Checklist Window

Figure 9-8 Quick Start Checklist

The current step displayed indicates the next action that should be
performed by the user to start a load. When the action is performed in
the CPAS-3000 Data Loader window, the current step will automatically
become checked and the next step will be displayed. For instance,
when Step 3 is shown as the current step (as shown above), selecting
a target from the Select Target/LRU to be Updated drop-down box will
cause Step 3 to become checked and advance to Step 4 as the current
step. The current step in the list can also be manually checked off by
clicking on the box next to the step.

2nd Edition
6 Jun 08 9-7
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

Once the last step, Step 5, has been completed by starting a load,
Steps 3 – 5 will automatically become unchecked and Step 3 will be
displayed as the current step. This indicates the user can start another
load by selecting another target and continuing down the checklist.
Click the CLOSE button to close the Quick Start Checklist window. If
the DO NOT SHOW THIS AGAIN BOX is checked, the window will no
longer be displayed on application startup. By default, this box is not
checked.
Displaying the Quick Start Checklist window on startup can also be
enabled or disabled by selecting Help Show Quick Start Checklist on
Startup from the main CPAS-3000 Data Loader menu bar. This menu
item can either be checked or not checked, and selecting the menu
item will toggle its checked status. When checked, the Quick Start
Checklist window will be displayed on application startup. This menu
item is checked by default.

CPAS-3000 DATA LOADER WINDOW


The CPAS-3000 DATA LOADER window (Figure 9-9) is displayed
once the STARTING CPAS-3000 window has finished configuring the
network adapter. The following sections describe the use and function
of the Data Loader controls.

2nd Edition
9-8 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows CPAS-3000 Data Loader Window

Figure 9-9 CPAS-3000 Data Loader Window

LOAD DIRECTION
The pressed button indicates the current load direction (Figure 9-10).
To change the load direction, simply click on the button of the desired
direction. Upload will transfer data/software from the CPAS to the
selected target/LRU. Download will transfer data/software from the
selected target/LRU to the CPAS. UPLOAD is selected by default.

Figure 9-10 Load Direction Buttons

In this example, UPLOAD is selected as the load direction.

2nd Edition
6 Jun 08 9-9
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

ACQUIRE/REFRESH TARGETS
Click on the ACQUIRE/REFRESH TARGETS button to refresh the
SELECT TARGET/LRU TO BE UPDATED list (Figure 1-11). A query
command (as defined by ARINC 615A) is sent to all data load targets
attached to the Ethernet network, and the targets that reply to this query
are added to the list.

Figure 9-11 Acquire/Refresh Targets

While a load is in progress or the Data Loader is waiting for targets to


response to the query command, the ACQUIRE/REFRESH TARGETS
button remains grayed (disabled).

SELECT TARGET/LRU TO BE UPDATED


The SELECT TARGET/LRU TO BE UPDATED drop-down box (Figure
9-12) is a list of targets or LRUs that are currently available for data
loading via the Ethernet network. In order to generate this list, an
Acquire/Refresh Targets query must be sent by the CPAS. This list is
then generated using the type name and position of all targets that reply
to this query command. When one or more targets reply to this query
command, the drop-down portion of the drop-down box is automatically
displayed. The Acquire/Refresh Targets query can be sent automatically
when CPAS is started, or manually through the ACQUIRE/REFRESH
TARGETS button or the VIEW and then ACQUIRE/REFRESH
TARGETS menu item. For more information on how to issue this query,
refer to the Refresh Targets section later in this operator’s guide.

2nd Edition
9-10 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows CPAS-3000 Data Loader Window

Figure 9-12 Select Target/LRU to be Updated Window

The target’s type name is displayed in the left column of the list item.
In the example above, the selected target’s type name is FSU. The
target’s position is displayed in the right column of the list item. In Figure
9-12, L28 is the selected target’s position. For Ethernet-based LRUs,
the target’s hardware ID is listed in parenthesis following the position. In
this example above, Col_FSU is the selected target’s hardware ID.
NOTE
N
The targets displayed in the drop-down box are filtered based on
the selected load direction. For instance, if the Download button
is selected, only targets supporting downloads will be displayed,
which are currently only the FMCs and MDC.

SELECT DATA/SOFTWARE TO BE UPDATED


The SELECT DATA/SOFTWARE TO BE UPDATED drop-down box
(Figure 9-13) contains the part numbers or names of the data/software
items available for loading. By default, the drop-down box displays
data/software items that were imported to the PC’s hard drive.
Data/software items on CD, DVD, or removable drives in the PC can be
displayed by clicking on the SELECT DRIVE button and selecting the
desired drive from the pop-up menu displayed. For more information
on selecting the drive to load data/software, refer to the Select Drive
section later in this Operator’s Guide.
The SELECT DATA/SOFTWARE TO BE UPDATED drop-down box
remains grayed (disabled) until a target has been selected. Once
a target has been selected, if one or more data/software items are

2nd Edition
6 Jun 08 9-11
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

available for loading, the drop-down portion of the drop-down box is


automatically displayed.

Figure 9-13 Select Data/Software to be Updated Window

In Figure 9-13, the selected data/software item’s part number is


CRC29-SL0T-0000.
NOTE
N
The data/software items displayed in the drop-down box are
filtered based on the selected load direction and target. Only the
data/software items that support the selected load direction and
correspond to the data load type of the selected target (615A,
615-3, or DBU) are shown in the drop-down box (i.e., if a FMC
target is selected, only DBU compatible data/software items for a
FMC will be displayed).

When a 615A target is selected, the data/software items displayed in the


drop-down box can also be further filtered by selecting VIEW and then
FILTER DATA/SOFTWARE FOR SELECTED TARGET from the main
CPAS-3000 Data Loader menu bar. This will cause only data/software
items that either specifically list the selected 615A target as a compatible
target, or list no compatible targets in the data/software item’s header
files to be displayed. This menu option remains grayed (disabled) until
a 615A target has been selected and defaults to checked.
By default, the data/software items shown are ordered alphabetically by
part number/name. Alternatively, the items can be ordered by creation
date by selecting VIEW, ARRANGE/DATA/SOFTWARE BY and then
DATA from the main CPAS-3000 Data Loader menu bar. The order can
be changed back to alphabetical by part number/name by selecting
VIEW, ARRANGE DATA/SOFTWARE BY and then NAME.

2nd Edition
9-12 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows CPAS-3000 Data Loader Window

LOAD FROM
The LOAD FROM area above the SELECT DRIVE/SOFTWARE TO BE
UPDATED displays the drive where data/software items in the SELECT
DRIVE/SOFTWARE TO BE UPDATED list is stored. This area is for
display purposes only.To change the drive from which data/software
items will be loaded, select VIEW and then SELECT DRIVE from the
menu bar. The SELECT DRIVE pop-up window will be displayed with
the hard drive and any available CD, DVD, and removable drives on the
PC. Select a drive from the list and click the OK button.

Figure 9-14 Load From Hard Drive Button

When a new drive is selected using the SELECT DRIVE pop-up, the
LOAD FROM area is updated with the icon and drive letter of the new
selection. The SELECT DATA/SOFTWARE TO BE UPDATED list is
updated with the data/software items found on the selected drive.

BEGIN LOAD
After selecting a target from the SELECT TARGET/LRU TO BE
UPDATED drop-down box and a data/software item from the SELECT
DATA/SOFTWARE TO BE UPDATED drop-down box, click the BEGIN
LOAD button (Figure 9-15) to begin the load.

Figure 9-15 Begin Load Button

After clicking on the BEGIN LOAD button, a tab displaying the status
of the load will appear in the STATUS area. If any other load tabs are
displayed in the STATUS area, the newly added tab will be displayed on
top of the other tabs.

2nd Edition
6 Jun 08 9-13
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

The BEGIN LOAD button remains grayed (disabled) until a target and a
data/software item have been selected (Figure 9-16).

Figure 9-16 Begin Load Grayed

STATUS TABS
A status tab (Figure 9-17) is created for each load that is started by
clicking on the BEGIN LOAD button. Each load status tab in the
STATUS area contains the selected target’s type name and position,
the selected data/software item’s part number or name, the overall
percentage of the load completed, and an icon indicating the current
state of the load process.
The three load state icons are:

• Indicates the load is currently in progress (rotates periodically)

• Indicates the load has successfully completed

• Indicates the load has encountered an error

Figure 9-17 Status Window

2nd Edition
9-14 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows CPAS-3000 Data Loader Window

In Figure 9-17, the icon indicates the load is currently in progress. The
target’s type name and position are FSU and L28, the data/software
item’s part number is CRC29-SL0T-0000, and the load is 88 percent
complete.
The status window contains two progress bars. The FILE progress
bar graphically indicates the percentage of the current file that is
being loaded. The name of the file currently being loaded is displayed
immediately above the FILE progress bar. In the example shown above,
the load of the current file, 7844-CRC29-SL0T-0000.017, is about
20% complete (the progress bar is roughly 20% full). The OVERALL
PROGRESS bar graphically indicates the overall percentage of the
load completed.
Status information for the load process is logged to a text file. The
status window displays these logged messages if the DISPLAY
LOGGED STATUS INFO box is checked. These messages can be
useful troubleshooting information to assist Rockwell Collins Customer
Support when the Data Loader does not operate as expected. By
default, this box is checked.
The load may be cancelled by clicking on the CANCEL UPLOAD button
(or CANCEL DOWNLOAD, if a download is in progress). If the load is
cancelled, encounters an error, or completes successfully, the button
text will change to CLOSE STATUS. Clicking on the CLOSE STATUS
button will remove the status tab for that load process.
If the CLOSE STATUS ON COMPLETION box is checked, the status
tab for the load will be closed automatically upon successful completion
of the load process. By default, the CLOSE STATUS ON COMPLETION
box is checked unless the ALWAYS CLOSE ON SUCCESSFUL LOAD
box is checked in the configured settings. Refer to the GENERAL
section of the DATA LOADER CONFIGURATION WINDOW topic
for information on the ALWAYS CLOSE ON SUCCESSFUL LOAD
setting. By default, the CLOSE STATUS ON COMPLETION box is NOT
checked unless the ALWAYS CLOSE ON SUCCESSFUL LOAD box is
not checked in the configuration settings.
If an error occurs during a load, the status tab for that load (Figure 9–18)
is displayed on top of all other tabs. The tab will not close automatically
even if the CLOSE STATUS ON COMPLETION box is checked.

2nd Edition
6 Jun 08 9-15
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

Figure 9-18 Status Window with Error Icon

In Figure 9-18, the displayed load encountered a protocol timeout error.


As a result, the tab has been brought to the front and the button text
has been changed to CLOSE STATUS.
In addition, for each failed load, an error dialog will be displayed. The
error dialog (Figure 1-19) displays the target and data/software involved
in the load, along with tips for troubleshooting the failure.

2nd Edition
9-16 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows CPAS-3000 Data Loader Window

Figure 9-19 Load Failed Window

After reviewing the load failure information, click on CLOSE to close


the window.

SHOW DETAILED INFORMATION


When the SHOW DETAILED INFORMATION box (Figure 9-20) is
checked, information about the selected target and the selected
data/software item are displayed.

2nd Edition
6 Jun 08 9-17
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

Figure 9-20 Show Detailed Information Window

In Figure 9-20, detailed information about a data/software item with part


number CRC29-SL0T-0000 is displayed.

CHECK INTEGRITY OF SELECTED DATA/SOFTWARE


The VIEW and then CHECK INTEGRITY OF SELECTED
DATA/SOFTWARE menu item checks the integrity of the files
associated with the selected data/software item, verifying each file
is valid. This feature is only available for ARINC 665 formatted
and Navigation Database data/software items. The menu item will
remain grayed (disabled) until an ARINC 665 formatted or Navigation
Database data/software item has been selected from the SELECT
DATA/SOFTWARE TO BE UPDATED drop-down list.
Once an ARINC 665 formatted or Navigation Database data/software
item has been selected, select VIEW and then CHECK INTEGRITY
OF SELECTED DATA/SOFTWARE from the main CPAS-3000 Data
Loader menu bar to start the integrity check. The CHECK INTEGRITY
window is shown in Figure 9-21.

Figure 9-21 Check Integrity Window

2nd Edition
9-18 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows CPAS-3000 Data Loader Window

Upon completion of the integrity check, the CLOSE button will be


enabled and the text in the window will be updated to indicate the
results. If a file fails the integrity check, the name of the file and the
reason for failure will be displayed. Refer to the Data/Software Fails an
Integrity Check section under the Troubleshooting topic for information
on how to handle a failed integrity check.
Click on CLOSE to close the window.
NOTE
N
Depending on the size of the files associated with the data/software
item, the integrity check could take up to several minutes to
complete.

OPTIONAL POP-UP WINDOWS


During operation, pop-up windows are displayed to provide support
information or alert the user regarding expected behavior on the aircraft
systems. Each window contains an OK button to close the window
and a DO NOT SHOW THIS AGAIN box. If the DO NOT SHOW THIS
AGAIN box is checked when the OK button is clicked, the window will
no longer be displayed during CPAS-3000 operation. The display of the
optional pop-up windows can be re-enabled by selecting VIEW and
then CONFIGURATION from the main CPAS-3000 Data Loader menu
bar and clicking the SHOW ALL OPTIONAL POP-UP WINDOWS box
in the configuration settings. Refer to the General section of the Data
Loader Configuration Window topic for information on the Show All
Optional Pop-Up Windows box.
The first window (Figure 9-22) is displayed during an Acquire/Refresh
Targets query when a response to the query is received from the
PRIMARY TARGET NAME (specified on the FSU tab in the ADVANCED
configuration settings) (Figure 9–22). The window displays a note
regarding fault messages that may be shown on the cockpit display, but
are a normal effect of loading operations.

2nd Edition
6 Jun 08 9-19
PROGRAM OPERATION CPAS-3000 Data Loader
CPAS-3000 Data Loader Window Data Loading Software For Windows

Figure 9-22 Acquire/Refresh Targets

The second window (Figure 9-23) is displayed when an Acquire/Refresh


Targets query completes and a response to the query is received
from the PRIMARY TARGET NAME (specified on the FSU tab in
the ADVANCED configuration settings) (Figure 9-23). The window
provides support information, by type name, for the targets responding
to the query. If no support information is configured for the target
types responding to the query, this window is not shown. The support
information displayed can be modified in the configuration settings
(refer to the Edit Target Support Information window information under
the General section of the Data Loader Configuration Window topic).

Figure 9-23 Query Completes

2nd Edition
9-20 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Manage Data/Software Window

The third window (Figure 9-24) is displayed when the Data Loader
program is exited and the PRIMARY TARGET NAME (specified on
the FSU tab in the ADVANCED configuration settings) has replied to
a previous Acquire/Refresh Targets query (Figure 9-24). The window
provides an operational warning regarding when avionics power can
be removed.

Figure 9-24 Query Reply

MANAGE DATA/SOFTWARE WINDOW


The MANAGE DATA/SOFTWARE window (Figure 9-25) is displayed
by selecting FILE and then MANAGE DATA/SOFTWARE from the
main CPAS-3000 Data Loader menu bar, or by double clicking the
CPAS LAUNCH PAD icon and double clicking on the MANAGE
DATA/SOFTWARE button. The MANAGE DATA/SOFTWARE window
cannot be accessed while a dataload is in progress.
The part numbers or names and creation dates of the data/software
currently installed on the PC hard drive are displayed in the
DATA/SOFTWARE INSTALLED ON CPAS list box (refer to the Import
section for specific loadset directory information). A data/software item
can be selected by clicking on the part number/name or creation date;
any previous selections will be cleared and the selected item will be
highlighted. Multiple data/software items may be selected using the
standard Windows Ctrl/Shift keyboard combinations.
The data/software items can be sorted alphabetically by part
number/name or by creation date by clicking on the DATA/SOFTWARE
or DATE CREATED column headers, respectively. Clicking on a column
header multiple times will toggle between ascending and descending

2nd Edition
6 Jun 08 9-21
PROGRAM OPERATION CPAS-3000 Data Loader
Manage Data/Software Window Data Loading Software For Windows

sort order for that column. By default, the data/software items are
sorted by part number/name in ascending order.

Figure 9-25 Manage Data/Software Window

In this example, the data/software items are sorted by part number/name


(ascending) and a data/software item with the part number 100-1111-110
and creation date 12/17/2007 12:29 PM has been selected.
The use and function of the controls in the MANAGE DATA/SOFTWARE
window are described in the following sections.

REMOVE
The REMOVE button allows data/software to be removed from the PC
hard drive (refer to the Import section for specific loadset directory
information). The button remains grayed (disabled) until a data/software
item in the DATA/SOFTWARE INSTALLED ON CPAS list box has been
selected.
Use the following procedure to remove data/software. The procedure
assumes that the PC is running and the CPAS-3000 Data Loader
application has been successfully installed.
1. Double click on the CPAS LAUNCH PAD icon.

2nd Edition
9-22 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Manage Data/Software Window

2. The MANAGE DATA/SOFTWARE window can be accessed


by either double clicking on the MANAGE DATA/SOFTWARE
button, or by double clicking on the DATA LOADER button to
launch the application and selecting FILE and then MANAGE
DATA/SOFTWARE from the Data Loader menu bar.
3. Select the desired data/software item(s) by clicking on the part
number or name displayed in the DATA/SOFTWARE INSTALLED
ON CPAS list box.
4. Click on the REMOVE button.
5. A dialog box will appear to confirm the removal. Click OK to remove
the selected data/software items or click CANCEL to return to
the MANAGE DATA/SOFTWARE window without removing the
data/software item(s).
NOTE
N
All removed data/software is moved to the Recycle Bin, rather than
being permanently deleted. This allows removed data/software to
be restored as long as the Recycle Bin has not been emptied.

IMPORT
The IMPORT button allows data/software to be copied from floppy,
hard drive, CD-ROM, and network drives to the PC hard drive portion
managed by the Data Loader. Clicking on the IMPORT button will cause
the SELECT A DIRECTORY window (Figure 9-26) to be displayed.

2nd Edition
6 Jun 08 9-23
PROGRAM OPERATION CPAS-3000 Data Loader
Manage Data/Software Window Data Loading Software For Windows

Figure 9-26 Select Data/Software to Import Window

The SELECT A DIRECTORY window allows selecting an initial directory


to search for loadsets to import. The DRIVES drop-down box contains
all floppy, hard drive, CD-ROM, removable, and network drives detected
on the PC.
After selecting a drive, the drive’s root directory is displayed in the
DIRECTORY NAME box. All directories in the drive’s root directory
will be displayed next to folder icons. In the example above, the root
directory is D:\, which contains two directories, 100-1111-110 and
CZC5B-0000-0001.
Double-clicking on a directory folder icon will display all directories it
contains, with folder icons, below it. The DIRECTORY NAME box will
be updated with the full path of the selected directory.

2nd Edition
9-24 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Manage Data/Software Window

Once the desired directory has been selected, clicking on the OK button
will cause the Select Data/Software to Import window to be displayed
(Figure 9-27).

Figure 9-27 Select a Directory

All data/software detected in the selected directory will be displayed


in the AVAILABLE DATA/SOFTWARE list box. If the SEARCH
SUBDIRECTORIES box is checked, the Data Loader will automatically
search all subdirectories in the selected directory for data/software.
A window will pop up with the message SEARCHING FOR
DATA/SOFTWARE and a STOP SEARCH button allowing the
data/software search to be cancelled. Upon completion or cancellation
of the search, the discovered data/software items will be added to
the AVAILABLE DATA/SOFTWARE list box. By default, the SEARCH
SUBDIRECTORIES box is not checked. The last state of the SEARCH
SUBDIRECTORIES checkbox is saved and restored next time the
import procedure is used.
NOTE
N
Beware! Automatically searching subdirectories on network drives
may take a while, depending on the size of the network drive.

2nd Edition
6 Jun 08 9-25
PROGRAM OPERATION CPAS-3000 Data Loader
Manage Data/Software Window Data Loading Software For Windows

The selected directory can be changed using the DRIVES drop-down


box and directory folder icons in the same manner described for the
SELECT A DIRECTORY window. Additionally, if a network drive is not
present in the DRIVES drop-down box, the Network… button allows
network drives to be mapped. Click on the button and follow the Map
Network Drive window instructions to map the drive. If the network
drive is successfully mapped, the drive will be added to the DRIVES
drop-down box.
To import data/software, click on the desired data/software items in
the AVAILABLE DATA/SOFTWARE list box to toggle the check box
and click OK.
After clicking the OK button, the Data Loader application will store
the path contained in the DIRECTORY NAME box, and will default to
that directory path the next time the SELECT A DIRECTORY window
is displayed. If the directory path no longer exists, the root directory
of the C:\ drive will be selected and displayed. The IMPORTING
DATA/SOFTWARE window will then be displayed, as shown in Figure
9-28. The part numbers or names of all data/software being imported
are listed in the window. The data/software item currently being
imported will have the text Importing displayed in the right side of the
window.

Figure 9-28 Importing Data/Software Window

If a data/software item on the PC hard drive has the same name as


a data/software item being imported, a prompt will appear to confirm
overwriting the existing loadset. Overwritten loadsets will first be placed
in the Recycle Bin before importing the new loadsets.

2nd Edition
9-26 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Manage Data/Software Window

Upon successful completion of a data/software item import, the


text Done! is displayed in the right side of the IMPORTING
DATA/SOFTWARE window. If an error occurs during the import, the
text Error will be displayed. When ARINC 665 formatted or Navigation
Data/software items are imported, the integrity of the files associated
with the data/software item is checked to verify that each file is valid.
If an integrity check fails, an error message will be displayed in a
separate window listing the file that failed the check and the reason for
the failure. Refer to the Data/Software Fails an Integrity Check section
under the Troubleshooting topic for information on how to handle a
failed integrity check.
When all data/software item imports have either successfully completed
or failed due to an error, the CLOSE button will be enabled. Click on
CLOSE to close the window.
NOTE
N
If importing 615-3 compatible data/software that is not in the ARINC
665 defined format, a prompt will appear allowing a name to be
specified for the data/software. A suggested name will be displayed
based on the location of the data/software. The specified name will
be used to identify the imported data/software item.

The imported data/software item is stored as a subdirectory within the


data load type directory (i.e., \615A, \6153, or \DBU). The data load
type directories are located in a \Loadsets directory stored in the same
directory as the application executable. If the default installation path is
used, the loadset directory path would be C:\Program Files\Rockwell
Collins\CPAS-3000\Loadsets.
The name of the directory storing the imported data/software files
depends on the data load type. 615A and 615-3 data/software
directories are named after the data/software item part number, and
DBU data/software is stored in sequential directories \0.dbd, \1.dbd,
etc., in a directory named after the database type (e.g., \Navdb,
\Routes, \Perfdb, \Vspddb, \MDCData, or \Output).

CHECK INTEGRITY
The CHECK INTEGRITY button checks the integrity of the files
associated with a data/software item, verifying each file is valid.
This feature is only available for ARINC 665 formatted or Navigation
Database data/software items, and integrity checks can only be

2nd Edition
6 Jun 08 9-27
PROGRAM OPERATION CPAS-3000 Data Loader
Manage Data/Software Window Data Loading Software For Windows

performed on one data/software item at a time. The button will remain


grayed (disabled) until exactly one ARINC 665 formatted or Navigation
Database data/software item in the DATA/SOFTWARE INSTALLED ON
CPAS list box has been selected.
Once an ARINC 665 formatted or Navigation Database data/software
item has been selected, click on the CHECK INTEGRITY to start the
integrity check. The CHECK INTEGRITY window will be displayed,
as shown in Figure 9-29.

Figure 9-29 Check Integrity Window

Upon completion of the integrity check, the CLOSE button will be


enabled and the text in the window will be updated to indicate the
results. If a file fails the integrity check, the name of the file and the
reason for failure will be displayed. Refer to the Data/Software Fails an
Integrity Check section under the Troubleshooting topic for information
on how to handle a failed integrity check.
Click on CLOSE to close the window.
NOTE
N
Depending upon the size of the files associated with the
data/software item, the integrity could take up to several minutes to
complete.

REFRESH
The REFRESH button refreshes the list of data/software items displayed
in the DATA/SOFTWARE INSTALLED ON CPAS list box. If a loadset is
installed during program operation using any method other than through
the SELECT DATA/SOFTWARE TO IMPORT window (e.g., a separate
installation program for the data/software item), click on the REFRESH
button to allow CPAS to detect the newly installed data/software item.

2nd Edition
9-28 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Manage Data/Software Window

ADVANCED
The ADVANCED button allows detailed information for the selected
data/software item to be viewed and load parameters for the
data/software item to be viewed and modified. This feature is
available for only one data/software item at a time, so the button will
remain grayed (disabled) until exactly one data/software item in the
DATA/SOFTWARE INSTALLED ON CPAS list box has been selected.
Once a data/software item has been selected, click on the ADVANCED
button to display the DATA/SOFTWARE PROPERTIES window (Figure
9-30). The DETAILED INFORMATION tab displays detailed information
for the data/software item. The information displayed is dependent on
the data load type of the data/software item.

2nd Edition
6 Jun 08 9-29
PROGRAM OPERATION CPAS-3000 Data Loader
Manage Data/Software Window Data Loading Software For Windows

Figure 9-30 Data/Software Properties

The second tab contains the load parameters for the data/software
item. The type of tab displayed depends on what data load type the
selected data/software item is compatible with (615A, 615-3, or DBU).
In this example, a 615A data/software item had been selected, so the
615A properties tab is displayed.
NOTE
N
Modifications of these parameters could affect the success of the
actual load to the target/LRU.

2nd Edition
9-30 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Manage Data/Software Window

Figure 9-31 615A Properties

The 615A tab in the DATA/SOFTWARE PROPERTIES window contains


the load parameters for the data/software item. The parameter values
are obtained from a file, LoadParams.ini, stored in the data/software
loadset directory. If no LoadParams.ini file exists in the directory, the
tab will display the 615A parameter values stored in the Data Loader
advanced configuration settings. For information on these parameters,
refer to the Advanced section of the Configuration Window topic.
To modify parameters, change the desired values and click OK. The
modified parameter values will be stored in the LoadParams.ini file in

2nd Edition
6 Jun 08 9-31
PROGRAM OPERATION CPAS-3000 Data Loader
Requesting 615A Target Data Loading Software For Windows

the data/software’s loadset directory, and will be used for subsequent


data loads involving the data/software item.
Clicking on the USE 615A GLOBAL SETTINGS will set the parameter
values to the 615A parameter values stored in the Data Loader
advanced configuration settings.
NOTE
N
The load parameters for the data/software item will be stored in a
file only if one or more of the parameter values are modified. When
storing the values, if the file does not already exist in the directory,
the Data Loader application will create it.

CLOSE
The CLOSE button closes the MANAGE DATA/SOFTWARE window.

REQUESTING 615A TARGET


The 615A TARGET INFORMATION window (Figure 9-32) is displayed
by selecting VIEW and then TARGET INFORMATION from the main
CPAS-3000 Data Loader menu bar. This menu item remains grayed
(disabled) until a 615A target has been selected from the SELECT
TARGET/LRU TO BE UPDATED drop-down box in the DATA LOADER
window.

2nd Edition
9-32 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

Figure 9-32 615A Target Information Window

The Data Loader issues a 615A target information request for the
selected target, and the information received from the target is
displayed. The displayed messages are also logged to a text file. Upon
completion of the information request, the RETRIEVING TARGET
INFORMATION label changes to TARGET INFORMATION.

DATA LOADER CONFIGURATION WINDOW


The DATA LOADER CONFIGURATION window (Figure 9-33) is
displayed by selecting VIEW and then CONFIGURATION from the main
CPAS-3000 Data Loader menu bar. From this window, the common
configuration settings for the application may be viewed and modified.
Modified settings may be saved for only this Data Loader session or
for all future Data Loader sessions upon closing the DATA LOADER
CONFIGURATION window. The use and function of the controls in the
configuration window are described in the following sections.

2nd Edition
6 Jun 08 9-33
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

Figure 9-33 Data Loader Configuration Window

GENERAL
The General section contains five check boxes
• AUTOMATICALLY ACQUIRE/REFRESH TARGETS ON STARTUP:
When this box is checked, the Data Loader will automatically issue a
Acquire/Refresh Targets query on application startup to the data load
targets attached to the Ethernet network. This box is not checked
by default.

2nd Edition
9-34 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

• AUTOMATICALLY INITIATE DATALOAD MODE ON FSU: This box


determines whether or not the Data Loader will automatically request
the FSU to go into dataload mode after the application receives
the PRIMARY TARGET NAME (specified on the FSU tab in the
ADVANCED configuration settings) as one of the targets responding
to the Acquire/Refresh Targets query. This box is checked by default.
NOTE
N
This box needs to be checked if data loading of LRUs, like the FMC
or MDC, that are connected to the FSU is required.

• ALWAYS CLOSE ON SUCCESSFUL LOAD: When this box


is checked, all new loads will have the CLOSE STATUS ON
COMPLETION box checked. This box is not checked by default.
• SHOW TOOL TIPS: When this box is checked, many of the buttons
and controls in the Data Load application will show pop-up tool tips
when the mouse pointer is positioned over the button or control. This
box is checked by default.
• SHOW ALL OPTIONAL POP-UP WINDOWS: When one or more
of the optional pop-up windows (refer to the Optional Pop-Up
Windows section of the CPAS-3000 Data Loader Window topic)
have been checked with DON NOT SHOW THIS AGAIN, this box
will be unchecked. Checking this box will re-enable the display of
all optional pop-up windows. This box is checked by default, as all
optional pop-up windows are shown by default.
The EDIT TARGET SUPPORT INFORMATION button displays the
EDIT TARGET SUPPORT INFORMATION window. This window allows
editing the list of target type names for which support information is
shown, and the support information shown for each type name, in
the ACQUIRED TARGETS/LRU SUPPORT INFORMATION optional
pop-up window (refer to the Optional Pop-Up Windows section of the
CPAS-3000 Data Loader Window topic).

2nd Edition
6 Jun 08 9-35
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

Figure 9-34 Edit Target Support Information

The TARGET TYPE NAMES list shows the target type names for which
support information is configured. An item can be selected by clicking
on the target type name; any previous selections will be cleared and
the selected item will be highlighted. Multiple target type names may be
selected using the standard Windows Ctrl/Shift keyboard combinations.
When exactly one target type name item is selected, the support
information for the target type is displayed in the SUPPORT
INFORMATION box. The information can then be edited and saved by
clicking on the Save Updates button. The Save Updates button remains
grayed (disabled) until the support information has been edited.
The NEW button displays the Add New Target Type window (Figure
9-35).

2nd Edition
9-36 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

Figure 9-35 Support Information

Support information for a new target type can be added by entering


the type name in the TARGET TYPE NAME box and the support
information in the SUPPORT INFORMATION box, then clicking the OK
button. Clicking the CANCEL button will discard the target type name
and support information entered and close the ADD NEW TARGET
TYPE window.
The REMOVE button allows target type name items and their support
information to be removed from the configuration settings. The button
remains grayed (disabled) until a target type name in the TARGET
TYPE NAMES list has been selected.

LOGGING
The CPAS-3000 will always log load information into a log file. This
information can be useful in determining the cause of unsuccessful
dataloads. The controls contained in the Logging section are:

2nd Edition
6 Jun 08 9-37
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

• LOG FILE DIRECTORY: Contains the directory where the log file for
the Data Loader application session is written. A log file is created for
the session when either a data load or target information request is
initially performed. The default directory for log files is C:\CPAS\Logs.
This location can be changed by entering a directory name in the
LOG FILE DIRECTORY box or by clicking on the BROWSE button
and selecting an alternative directory location. If the directory
entered did not previously exist, a message box will be presented
upon exiting the DATA LOADER CONFIGURATION window, asking
whether or not the directory should be created. Click YES to create
the directory and exit, or NO to return to the configuration window.
• LOG DETAILED LOAD INFORMATION: This box determines the
level of detail of the information logged during a load. When checked,
detailed information is logged. When not checked, only basic load
information is logged. This box is not checked by default.
NOTE
N
Beware! Logging of detailed load information may dramatically
slow down a dataload and in some cases prevent the load from
completing successfully.

• DELETE LOG FILES OLDER THAN: This box determines whether


or not log files located in the log file directory that are older than the
amount of days specified should be deleted. When checked, deletion
of the old log files occurs on application startup. The number of days
must be between 1 and 365, and the default number of days is 60.
The DELETE LOG FILES OLDER THAN box is checked by default.

RESTORE DEFAULTS
The RESTORE DEFAULTS button restores the application default
values for all of the settings on the DATA LOADER CONFIGURATION
window. When clicked, a dialog box will appear to confirm restoring the
application default values.

ADVANCED
The ADVANCED button can be used to access and to modify advanced
configuration settings. When clicked, a dialog box will appear with a
note of caution about modifying advanced settings

2nd Edition
9-38 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

NOTE
N
Beware! Modifications of these parameters could render the
CPAS-3000 inoperable.

After clicking the OK button on the dialog box, the CONFIGURATION


window is displayed. The window contains six tabs: FSU, 615A, DBU,
615-3, NETWORK, and IOC. Modified settings may be saved for only
this Data Loader session or for all future Data Loader sessions upon
closing the CONFIGURATION window.

FSU TAB
The FSU tab (Figure 9-36) contains parameters involving the interaction
of the Data Loader with the FSU.

2nd Edition
6 Jun 08 9-39
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

Figure 9-36 Configuration Window: FSU Tab

The parameters and controls contained on the FSU tab are:


• PRIMARY TARGET NAME: This value specifies the name of the
FSU target expected in the response to the Acquire/Refresh Targets
query. The CPAS will use the IP address from this target to establish
the port connections of the LRUs connected to the FSU (i.e., FMC,
MDC and 615-3 targets). The default primary target name is FSU.
• REFRESH TARGETS TIMEOUT (SEC): This value specifies the
amount of time that the Data Loader should continue to issue
Acquire/Refresh Targets queries on application startup if no
responses are received. The default timeout value is 30 seconds.

2nd Edition
9-40 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

NOTE
N
The Refresh Targets timeout value is only applicable if the
AUTOMATICALLY ACQUIRE/REFRESH TARGETS ON STARTUP
box is checked on the DATA LOADER CONFIGURATION window.

• WAIT TIME FOR PORT CONNECTION (SEC): This value specifies


the amount of time, in addition to the FSU-specified reboot wait time,
that the Data Loader should attempt to connect to the FSU ports
listed in this tab. The default wait time is 30 seconds.
NOTE
N
The FSU port connections are only established when the
AUTOMATICALLY INITIATE DATALOAD MODE ON FSU box is
checked on the DATA LOADER CONFIGURATION window and the
FSU target specified by PRIMARY TARGET NAME is first returned
to the Acquire/ Refresh Targets query.

The six port controls allow the port numbers to be specified for each of
the FSU ports. The default values for each are:
• ARINC 615-3 LOW SPEED PORT is 8351
• ARINC 615-3 HIGH SPEED PORT is 8352
• FMC #1 PORT is 8353
• FMC #2 PORT is 8354
• FMC #3 PORT is 8356
• MDC PORT is 8355.
Icons in the PORT CONNECTED column indicate the connection status
of the port in that row. A green circle icon indicates the port is connected
and a red X icon indicates the port is not connected. For example, in the
FSU tab shown in Figure 9-36, the ARINC 615-3 HIGH SPEED PORT
icon indicates that the port is not connected, while the FMC #1 PORT
icon indicates that port is connected.
There will only be one ARINC 615-3 port connected at any one time.
The CPAS will connect the appropriate ARINC 615-3 port based on the
bus speed being used for the data load.
Icons in the LRU RESPONDING column indicate whether or not the
target connected through the port is responding to poll bytes sent by
the Data Loader. A green circle icon indicates the target is responding,
a green circle icon with a black plus sign (+) inscribed in the circle

2nd Edition
6 Jun 08 9-41
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

indicates the target is responding and supports the enhanced DBU


mode, and a red X icon indicates that the target is not responding. For
example, in the FSU tab shown in Figure 9-36, the FMC #1 PORT
icon indicates that the target is responding, while the MDC PORT icon
indicates that the target is responding and supports the enhanced
DBU mode.
NOTE
N
Poll bytes are only sent for the DBU data load type, so the 615-3
port icons for the LRU RESPONDING column display N/A to
indicate this column is not applicable to these ports.

Connected ports may be disconnected by clicking on the boxes next


to the port numbers and clicking on the DISCONNECT SELECTED
PORTS button. Any disconnected ports will not be reconnected until
the CPAS-3000 is restarted.
The RESTORE FSU DEFAULTS button restores the application default
values for all of the settings on the FSU tab. When clicked, a dialog box
will appear to confirm restoring the default values.

615A TAB
The 615A tab (Figure 9-37) contains load parameters for the ARINC
615A data load type.

2nd Edition
9-42 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

Figure 9-37 Configuration Window: 615A Tab

The parameters and controls contained on the 615A tab are:


• BLOCK SIZE (BYTES): This value specifies the largest block size
that a load operation will accept or reject. The default value is 32,768
bytes.
• DATA LOADER PACKET TIMEOUT (SEC): This value specifies the
amount of time the Data Loader will allow between the emissions
of the last packet of the Trivial File Transfer Protocol (TFTP)
acknowledge and the reception of the first packet of the TFTP write
request. The default value is 13 seconds.

2nd Edition
6 Jun 08 9-43
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

• DATA LOADER PACKET RETRY COUNT: This value specifies the


number of retries allowed by the Data Loader after one first failed
TFTP before declaring failure with an error code. The retry number
does not include the first TFTP. The default value is 1.
• TFTP TIMEOUT (SEC): This value specifies the amount of time
allowed between the emission of one TFTP packet and the reception
of the associated answer packet on the same TFTP. The default
value is 2 seconds.
• TFTP RETRY COUNT: This value specifies the number of allowed
retries after a failed transmission before declaring a TFTP failure
with an error code. The retry number does not include the first
transmission. The default value is 1.
• TFTP TARGET PORT: This value specifies the port that TFTP will
transmit on. The default value is 59.
• TFTP LOCAL PORT: This value specifies the port that TFTP will
listen on. The default value is 59.
• SNIP TARGET PORT: This value specifies the port that SNIP
requests will transmit on. The default value is 1001.
• SNIP LOCAL PORT: This value specifies the port to listen on for
responses to a SNIP request. The default value is 1001.
NOTE
N
SNIP (Simple Network Identification Protocol) is the term used by
ARINC 615A to specify the Acquire/Refresh Targets query. SNIP
has also been renamed to FIND (Find Identification of Network
Devices) in later ARINC 615A reports.

The RESTORE 615A DEFAULTS button restores the application default


values for all of the settings on the 615A tab. When clicked, a dialog
box will appear to confirm restoring the default values.

DBU TAB
The DBU tab (Figure 9-38) contains load parameters for the DBU data
load type

2nd Edition
9-44 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

Figure 9-38 Configuration Window: DBU Tab

The parameters and controls contained on the DBU tab are:


• NO RESPONSE TIMEOUT (SEC): This value specifies the maximum
amount of time the Data Loader will wait between the reception
of bytes when processing data packets. The default value is 20
seconds.
• POLL BYTE TIMEOUT (MSEC): This value specifies the maximum
amount of time the Data Loader will wait for a response to a poll byte.
The default value is 200 msec

2nd Edition
6 Jun 08 9-45
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

• TARGET RESET TIMEOUT (SEC): This value specifies the


maximum amount of time required for a DBU target to reset from a
successful dataload. Following a successful load to a DBU target,
loads initiated to the target during the reset timeout will be delayed
until the timeout has been reached. The default value is 5 seconds.
• TARGET RECOVERY TIMEOUT (SEC): This value specifies the
maximum amount of time required for a DBU target to recover from
a failed dataload. Following a failed load to a DBU target, loads
initiated to the target during the recovery timeout will be delayed until
the timeout has been reached. The default value is 45 seconds.
• MAXIMUM NUMBER OF DATABASE VERSIONS STORED ON
CPAS: This value specifies the maximum number of database
versions of a database type (e.g., Nav, Perf, or Vspeed databases)
that can be stored by the Data Loader. The default value is 6.
• SEND ENHANCED POLL BYTE: This box determines whether or
not enhanced poll bytes will be sent out to DBU targets alternated
with normal poll bytes. The box is checked by default.
The RESTORE DBU DEFAULTS button restores the application default
values for all of the settings on the DBU tab. When clicked, a dialog box
will appear to confirm restoring the default values.

615-3 TAB
The 615-3 tab (Figure 9-39) contains load parameters for the 615-3
data load type.

2nd Edition
9-46 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

Figure 9-39 Configuration Window: 615-3 Tab

The parameters and controls contained on the 615-3 tab are:


• FINAL WORD RESPONSE TIMER (MSEC): This value specifies
the maximum amount of time the Data Loader will wait for an
acknowledgement after transmitting the final word of a record in a
dataload. The default value is 2700.
• RTS TRANSMIT TIMER (MSEC): This value specifies the amount of
time the Data Loader will wait between transmitting Request to Send
(RTS) words during a dataload. The default value is 50.

2nd Edition
6 Jun 08 9-47
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

• RTS TRANSMIT BACKOFF TIMER (MSEC): This value specifies


the amount of time the Data Loader will wait between transmitting
Request to Send (RTS) words during a dataload after the RTS
Transmit Counter has been exceeded or the target has responded
but is busy. The default value is 200.
• FINAL WORD RCVD TIMER (MSEC): This value specifies the
maximum amount of time the Data Loader will wait to receive the
final word of a record during a dataload. The default value is 2700.
• POLL TRANSMIT TIMER (MSEC): This value specifies the amount
of time the Data Loader will wait between transmitting poll words
during a dataload. The default value is 50.
• EOF TRANSMIT TIMER (MSEC): This value specifies the amount of
time the Data Loader will wait to receive end-of-file acknowledgement
during a dataload. The default value is 200.
• FILE SEQUENCING TIMER (MSEC): This value specifies the
amount of time the Data Loader will wait to receive file sequencing
acknowledgement during a dataload. The default value is 200.
• IDLE INPUT TIMER (MSEC): This value specifies the amount of time
the Data Loader will wait while not receiving any response from the
target during a dataload. The default value is 30000.
• 2ND CHANCE RECOVER TIMER (MSEC): This value specifies the
maximum amount of time the Data Loader will allow for 2nd chance
recovery from a failure during a dataload. The default value is 10000.
• INTER-RECORD GAP TIMER (MSEC): This value specifies the
amount of time the Data Loader will wait between transmitting
records during a dataload. The default value is 0.
• SUBSYS ID TRANSMIT COUNTER: This value specifies the
maximum number of times the Data Loader will attempt to transmit
the Subsystem Id word during a dataload. The default value is 50.
• RTS TRANSMIT COUNTER: This value specifies the maximum
number of times the Data Loader will attempt to transmit the Request
to Send (RTS) word at the RTS Transmit Timer interval during a
dataload. The default value is 4.
• RTS TRANSMIT BACKOFF COUNTER: This value specifies the
maximum number of times the Data Loader will attempt to transmit
the Request to Send (RTS) word at the RTS Transmit Backoff Timer
interval during a dataload. The default value is 4.

2nd Edition
9-48 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

• RECORD TRANSMIT COUNTER: This value specifies the maximum


number of times the Data Loader will attempt to transmit a record
during a dataload. The default value is 4.
• POLL TRANSMIT COUNTER: This value specifies the maximum
number of times the Data Loader will attempt to transmit a poll word
during a dataload. The default value is 4.
The RESTORE 615-3 DEFAULTS button restores the application
default values for all of the settings on the 615-3 tab. When clicked, a
dialog box appears to confirm restoring the default values.

NETWORK TAB
The NETWORK tab (Figure 9-40) contains network parameters for the
Data Loader.

2nd Edition
6 Jun 08 9-49
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

Figure 9-40 Configuration Window: Network Tab

The parameters contained on the NETWORK tab are:


• SELECTED NETWORK ADAPTER: This value specifies the network
adapter that is used by the Data Loader.
• IP ADDRESS: This value specifies the IP address that will be used
by the Data Loader. The default value is 10.191.254.254.
• SUBNET MASK: This value specifies the subnet mask that will be
used by the Data Loader. The default value is 255.240.0.0.

2nd Edition
9-50 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Data Loader Configuration Window

• MTU SIZE: This value specifies the size of the Maximum


Transmission Unit (MTU) that will be used by the Data Loader. The
default value is 576.
• RESTORE ORIGINAL NETWORK ADAPTER PARAMETERS ON
EXIT: This box determines whether or not the original network
adapter parameters are restored when the Data Loader program is
exited. If the PC is dedicated for Data Loading, then this box can be
unchecked. The box is checked by default.
NOTE
N
The default values specified for the NETWORK tab are the correct
parameters for communicating with the FSU. If the target/LRU
being loaded requires different parameters than the FSU, these
network values will need to be modified before being able to data
load the target/LRU.

The CHANGE button allows changing the network adapter that is


used by the Data Loader, as well as the adapter speed and duplex
configuration settings. When clicked, the windows described under
the Selecting the PC Network Adapter topic are shown. If the network
adapter selection is changed, the original network parameters for
the previously selected adapter will be restored prior to updating the
network parameters for the newly selected adapter.
The RESTORE NETWORK DEFAULTS button restores the application
default values for all of the settings on the NETWORK tab. When
clicked, a dialog box appears to confirm restoring the default values.

IOC TAB
The IOC tab (Figure 9-41) contains parameters for performing ARINC
615-3 uploads to ARINC 429 based LRUs externally connected to a
data load switch through an IOC that is connected to the Avionics
System LAN.

2nd Edition
6 Jun 08 9-51
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loader Configuration Window Data Loading Software For Windows

Figure 9-41 Configuration Window: IOC Tab

The parameters contained on the IOC tab are:


• ENABLE LOADING OF 429-BASED LRU VIA IOC This box
determines whether or not ARINC 615-3 uploads to 429-based LRUs
via the IOC (connected to the Avionics System LAN) are enabled.
When checked, an entry is automatically added to the target list
for uploading a 429-based LRU via the IOC in response to an
Acquire/Refresh Targets query. Additionally, when checked, ARINC
615-3 uploads to 429-based LRUs connected through the FSU are
disabled. The box is unchecked by default.

2nd Edition
9-52 6 Jun 08
CPAS-3000 Data Loader PROGRAM OPERATION
Data Loading Software For Windows Support Information

• TRANSMIT IP MULTICAST ADDRESS: This value specifies the IP


multicast address to which the Data Loader should transmit data for
uploads. The default value is 224.224.142.0.
• RECEIVE IP MULTICAST ADDRESS: This value specifies the IP
multicast address on which the Data Loader should receive data for
uploads. The default value is 224.224.136.204.
• TRANSMIT PORT: This value specifies the port to which the Data
Loader should transmit data for uploads. The default value is 9440.
• RECEIVE PORT: This value specifies the port on which the Data
Loader should receive data for uploads. The default value is 9316.
• STARTING TRANSMIT NDO ID: This value specifies the starting
ID of the NDOs that the Data Loader will transmit for uploads. The
system address label of the 429-based LRU being uploaded is added
to this value to calculate the actual NDO ID that will be used. The
default value is 3328.
• RECEIVE NDO ID: This value specifies the ID of the NDOs that the
Data Loader will receive for uploads. The default value is 4784.
• TRANSMIT NDO SOURCE: This value specifies the NDO source
value for the Data Loader to use when transmitting for uploads. The
default value is 0.
• RECEIVE NDO SOURCE: Receive NDO Source: This value
specifies the NDO source value for the Data Loader to check for on
NDOs received for uploads. The default value is 0.
The RESTORE IOC DEFAULTS button restores the application default
values for all of the settings on the IOC tab. When clicked, a dialog box
will appear to confirm restoring the default values.

HELP INFORMATION
The online help can be accessed by selecting HELP and then HELP
TOPICS from the main CPAS-3000 Data Loader menu bar. The help
topic for a window can also be accessed directly by pressing F1 on the
keyboard while the window is currently displayed.

SUPPORT INFORMATION
For support on the CPAS-3000 Data Loader application, contact your
local Customer Support Engineer or Rockwell Collins Technical Support
at 319-295-5000.

2nd Edition
6 Jun 08 9-53
PROGRAM OPERATION CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
9-54 6 Jun 08
CPAS-3000 Data Loader TROUBLESHOOTING
Data Loading Software For Windows Introduction

TROUBLESHOOTING

INTRODUCTION
This section provides a few troubleshooting tips for various common
problems.

CPAS-3000 DATA LOADER INSTALLATION


FAILS
Data Loader installation may fail if there is not sufficient hard drive
memory available on the PC. Additionally, if the user has restricted
rights on the system, a failure may occur while attempting to register
application-related COM objects. The user must have administrator
rights to install the CPAS-3000 Data Loader.

INSUFFICIENT HARD DRIVE MEMORY


Exit the installation program. Remove any unnecessary program files
stored on the PC hard drive and uninstall any unused programs using
ADD/REMOVE PROGRAMS from the CONTROL PANEL. Run the
CPAS-3000 Data Loader installation program to retry the installation.

UNABLE TO REGISTER THE COM OBJECTS


Exit the installation program. Contact your local system administrator
for further instructions on how to access or obtain an account with
administrator rights.

NO TARGETS AVAILABLE TO UPDATE


If no targets are shown in the SELECT TARGETS/LRU TO BE
UPDATED drop-down box, ensure the FSU and all other LRUs are
operating and are properly linked to the PC through the Ethernet
connections. If any LRUs are attached to the FSU, ensure that
the connectors to the FSU are fully tightened. Also, verify that
the appropriate Ethernet network connection was selected during
installation and that the network connection is properly configured for
the PC. Refer to the Network Tab under the Advanced section of the

2nd Edition
6 Jun 08 10-1
TROUBLESHOOTING CPAS-3000 Data Loader
Target/LRU Missing From the Update List Data Loading Software For Windows

Data Loader Configuration Window topic for information on viewing and


changing the network connection parameters.
Disable any internet security software, like firewalls and Virtual Private
Network (VPN) software, that may be running on the PC, as these
programs can block network traffic needed to communicate with the
LRUs. These programs should be re-enabled before connecting the PC
into any internet or office network.
After checking the connections, and disabling all internet security
software, refresh the target list by clicking on the ACQUIRE/REFRESH
TARGETS button. If no targets appear within a few seconds, exit the
CPAS-3000. Wait for at least a minute to allow any attached LRUs
to reboot into normal mode, then restart the CPAS-3000. If the Data
Loader is not configured to refresh targets automatically (refer to the
General section of the Data Loader Configuration Window topic), click
on the ACQUIRE/REFRESH TARGETS button.
If targets still do not appear, uncheck the AUTOMATICALLY REFRESH
TARGETS ON STARTUP box on the DATA LOADER CONFIGURATION
window (refer to the General section of the Data Loader Configuration
Window topic). When prompted upon closing the DATA LOADER
CONFIGURATION window, save the modified settings for all future
Data Loader sessions. Exit the CPAS-3000.
Wait for at least one minute to allow any attached LRUs to reboot
into normal mode, then restart the CPAS-3000. Click on the
ACQUIRE/REFRESH TARGETS button. If targets now appear,
there is a problem with the driver software for the network adapter
that does not allow the AUTOMATICALLY ACQUIRE/REFRESH
TARGETS ON STARTUP feature to work properly. Please contact
the laptop manufacturer or the network adapter manufacturer to see
if a newer version of the driver software for the network adapter
exists. The CPAS-3000 will still function properly except that the
ACQUIRE/REFRESH TARGETS button needs to be manually clicked
every time the CPAS-3000 is started.

TARGET/LRU MISSING FROM THE UPDATE


LIST
If a particular target/LRU is not shown in the SELECT TARGETS/LRU
TO BE UDATED drop-down box, ensure the corresponding target

2nd Edition
10-2 6 Jun 08
CPAS-3000 Data Loader TROUBLESHOOTING
Data Loading Software For Windows Unable to Import a Data/Software Item

hardware is operating and is properly linked to the PC through either an


Ethernet connection or the FSU.
If the missing target/LRU is a target attached to the FSU, verify that
the FSU is listed in the SELECT TARGETS/LRU TO BE UDATED
drop-down box. If the FSU is present in the list, open the FSU advanced
configuration settings to view the connection status of the particular
target/LRU port (refer to the Advanced section under the Data Loader
Configuration Window topic for information on accessing the FSU
settings). If the port is not connected, refer to the FSU operator’s
guide for further instructions on how to handle unsuccessful LRU port
connections.
After checking the connections, refresh the target list by clicking on the
ACQUIRE/REFRESH TARGETS button. If the missing target/LRU does
not appear within a few seconds, exit the CPAS-3000 and cycle power
on the missing target/LRU. Wait for at least one minute to allow the
target /LRU to reboot into normal mode, then restart the CPAS-3000
Data Loader.

INSTALLED DATA/SOFTWARE NOT SHOWN


If data/software previously imported (successfully) onto the CPAS-3000
does not appear in the DATA/SOFTWARE INSTALLED ON CPAS list in
the MANAGE DATA/SOFTWARE window, restart the CPAS-3000 and
open the MANAGE DATA/SOFTWARE window. If the data/software
still does not appear in the list, the data/software files may have been
corrupted. If the original data/software files are available, attempt to
import the original data/software files. If the import is also unsuccessful,
refer to the Unable to Import a Data/Software Item section under this
topic.

UNABLE TO IMPORT A DATA/SOFTWARE ITEM


Import problems can occur when a data/software item is not supported
or not recognized by the Data Loader, or when an error occurs during
the import operation.

2nd Edition
6 Jun 08 10-3
TROUBLESHOOTING CPAS-3000 Data Loader
Unable to Import a Data/Software Item Data Loading Software For Windows

DATA/SOFTWARE NOT SHOWN


If a data/software item is not shown in the AVAILABLE
DATA/SOFTWARE list in the SELECT DATA/SOFTWARE TO IMPORT
window, importing the data/software item may not be supported. Refer
to the Program Limitations topic for information on what types of
data/software imports are not supported by the CPAS-3000.
If the data/software import is not listed as unsupported, the
data/software item may be corrupted or missing files. Verify that the
data/software files are still valid, restart the CPAS-3000, and retry the
import. If the problem persists, refer to the Support Information topic for
support contact information.

ERROR OCCURRED DURING THE IMPORT


An error can occur while importing a data/software item if the import of
the data/software item is not supported from the media members that
contain it (e.g., multiple disks) or if the data/software item is corrupted
or missing files. If the import of the data/software item is not supported
from the media members that contain it, an error will be displayed
describing the incompatibility. Refer to the Program Limitations topic
for information on what types of data/software imports from media
members are not supported by the CPAS-3000.
If no specific error message is displayed during the import, the
data/software may be corrupted or missing files. Verify that the
data/software files are still valid, restart the CPAS-3000, and retry the
import. If the problem persists, refer to the Support Information topic for
support contact information.
A failed integrity check indicates that one or more of the files in a
data/software item have been corrupted. If an integrity check fails for a
data/software item stored on the hard drive, the data/software should
be removed from CPAS and re-imported from the original media (i.e.,
CD, DVD, USB memory stick, etc.). If the integrity check still fails for the
re-imported data/software item, please obtain an updated (valid) version
of the data/software item. Refer to the Manage Data/Software Window
topic for information on performing the remove and import operations.
If an integrity check fails for a data/software item stored on media other
than the hard drive (i.e., CD, DVD, USB memory stick, etc.), please
obtain an updated (valid) version of the data/software item.

2nd Edition
10-4 6 Jun 08
CPAS-3000 Data Loader TROUBLESHOOTING
Data Loading Software For Windows Dataload Failure Encountered

DATA/SOFTWARE FAILS AN INTEGRITY CHECK


A failed integrity check indicates that one or more of the files in a
data/software item have been corrupted. If an integrity check fails for a
data/software item stored on the hard drive, the data/software should
be removed from CPAS and re-imported from the original media (i.e.,
CD, DVD, USB memory stick, etc.). If the integrity check still fails for the
re-imported data/software item, please obtain an updated (valid) version
of the data/software item. Refer to the Manage Data/Software Window
topic for information on performing the remove and import operations.
If an integrity check fails for a data/software item stored on media other
than the hard drive (i.e., CD, DVD, USB memory stick, etc.), please
obtain an updated (valid) version of the data/software item.

DATALOAD FAILURE ENCOUNTERED


If a dataload fails, load status messages can help diagnose the cause
of the failure. Click on the status tab for the load and make sure
the DISPLAY LOGGED STATUS INFO box is checked. If this box
is checked and no status information is displayed while the load is in
progress, cancel the dataload. Close the status tab for the load, click
Acquire/Refresh Targets, and retry the dataload.
If an ARINC 665 formatted or Navigation Database data/software item
is involved in the failed dataload, the integrity of the data/software
files can be checked by selecting VIEW and then CHECK INTEGRITY
OF SELECTED DATA/SOFTWARE from the main CPAS-3000 Data
Loader menu bar. If an error is encountered during the integrity check,
refer to the Data/Software Fails an Integrity Check section under the
Troubleshooting topic for more information on performing the integrity
check.

FILE MISSING
If the load status messages indicate a file is missing from the
data/software item, exit the CPAS-3000 and verify the data/software
item is still valid and all data/software files are located in the item’s
loadset directory. Restart CPAS-3000 and retry the dataload.

2nd Edition
6 Jun 08 10-5
TROUBLESHOOTING CPAS-3000 Data Loader
Dataload Failure Encountered Data Loading Software For Windows

TIMEOUT/COUNTER ERROR
If the load status messages indicate a timeout value or a retry counter
was exceeded, verify that the advanced configuration settings and
any stored load parameter values for the data/software being loaded
are set to the default values. Refer to the Properties section under
the Manage Data/Software Window topic for information on viewing
stored load parameter values, and the Advanced section under the
Data Loader Configuration Window topic for information on viewing
advanced configuration settings. Exit CPAS-3000 and disable any
screen savers or virus protection software running on the PC, as these
items may inhibit performance of the CPAS-3000. Restart CPAS-3000
and retry the dataload.

COMMUNICATION/TRANSMISSION ERROR
If the load status messages indicate a communication or transmission
error occurred, exit CPAS-3000. Verify the FSU or other Ethernet
based LRU is operating and is properly linked to the PC through the
Ethernet connection. Also, verify that the Ethernet network connection
is properly configured for the PC. Refer to the Configuring the Network
Settings section under the Setup topic for information on configuring
the Ethernet network connection.
If dataloading to an LRU connected to the FSU (FMCs, MDC, or
429 based LRUs), ensure that the connectors to the FSU are fully
tightened. Restart CPAS-3000 and retry the dataload. If a transmission
or communication error occurs again, verify that the advanced
configuration settings and any stored load parameter values for the
data/software being loaded are set to the default values. Refer to the
Properties section under the Manage Data/Software Window topic
for information on viewing stored load parameter values, and the
Advanced section under the Data Loader Configuration Window topic
for information on viewing advanced configuration settings. Disable any
screen savers or virus protection software running on the PC, as these
items may inhibit performance of the CPAS-3000. Restart CPAS-3000
and retry the dataload.
If the problem persists, refer to the Support Information topic for support
contact information.

2nd Edition
10-6 6 Jun 08
CPAS-3000 Data Loader TROUBLESHOOTING
Data Loading Software For Windows Other Notes

LOAD ABORTED
If the load status messages indicate the load is aborted by the target
hardware with either a LUH received failure or file received failure,
the network adapter may be misconfigured. Verify that the network
parameters are set to the default values (or to the appropriate settings
for the target/LRU being loaded). Refer to the Network Tab under the
Advanced section of the Data Loader Configuration Window topic for
information on viewing the network parameters.

WIRELESS OR LOCAL AREA CONNECTIONS


NOT WORKING
If wireless or local area network connections are not working properly
during CPAS-3000 operation, this may be a result of CPAS-3000
disabling active network connections on startup. If CPAS-3000 exits
abnormally during program operation and the active wireless or local
area network connections are not working properly, please restart
CPAS-3000 and exit to re-enable the network connections. Refer to the
Network Connections Detected Window topic under Program Operation
for information on how CPAS-3000 handles detected wireless and local
area network connections.

OTHER NOTES
• Disable any internet security software, like firewalls and Virtual
Private Network (VPN) software, that may be running on the PC, as
these programs can block network traffic needed to communicate
with the LRUs. These programs should be re-enabled before
connecting the PC into any internet or office network.
• Disabling virus protection software before starting CPAS-3000 is
recommended, as it may inhibit the performance of CPAS-3000
dataloads.
• Software that might cause the PC to enter a sleep mode if no
keyboard or mouse activity occurs, such as screen savers or power
savers, may inhibit the performance of CPAS-3000 dataloads.
Disabling this software before starting CPAS-3000 is recommended.

2nd Edition
6 Jun 08 10-7
TROUBLESHOOTING CPAS-3000 Data Loader
Data Loading Software For Windows

This page intentionally left blank

2nd Edition
10-8 6 Jun 08
CPAS-3000 Data Loader OPERATOR’S GUIDE
Data Loading Software For Windows Index

INDEX
Subject Page

A
Acquire/Refresh Targets ................................................................. 9-10
Acronyms: CPAS-3000 .................................................................. 1- 1
Advanced ....................................................................................... 9-29
Advanced button ............................................................................ 9-38
Always Close on Successful Load ................................................. 9-35
Automatically initiate dataload mode on FSU ................................. 9-35
Automatically refresh targets on startup ......................................... 9-34

B
Begin loading .................................................................................. 9-13

C
Cancel loading ................................................................................ 9-15
Check Integrity of Selected Data/Software ..................................... 9-18
Close .............................................................................................. 9-32
Communication/transmission error ............................................... 10- 6
Configuration window: 615-3 Tab ................................................... 9-46
Configuration window: 615A Tab .................................................... 9-42
Configuration window: DBU Tab .................................................... 9-44
Configuration window: FSU tab ...................................................... 9-39
Configuration window: IOC tab ...................................................... 9-51
Configuration window: network tab ................................................ 9-49
Configure Dataload Network Adapter Settings Window ................. 6- 2
CPAS-3000 Data Loader system requirements .............................. 3- 1
CPAS-3000 Data Loader window ................................................... 9- 8
CPAS-3000 Data Loader: installation failure ................................ 10- 1
CPAS-3000 Data Loader: installing ................................................ 4- 1
CPAS-3000 Data Loader: package contents ................................. 3- 2
CPAS-3000 Data Loader: program limitations ............................... 8- 1
CPAS-3000 Data Loader: starting .................................................. 4- 2
CPAS-3000 Data Loader: uninstalling ............................................ 4- 2
CPAS-3000 Data Loader: unlock software window ........................ 5- 1
CPAS-3000 Launch Pad ................................................................ 3- 2
CPAS-3000 Launch Pad window ................................................... 9- 1

2nd Edition
6 Jun 08 Index-1
OPERATOR’S GUIDE CPAS-3000 Data Loader
Index Data Loading Software For Windows

Subject Page

CPAS-3000 Window: exiting .......................................................... 9- 5


CPAS-3000 Window: starting ......................................................... 9- 4

D
Data load types: ARINC 615-3 ....................................................... 2- 1
Data load types: ARINC 615A ........................................................ 2- 1
Data Load Types, overview ............................................................ 2- 1
Data load types: RS-422 DBU-based ............................................ 2- 1
Data Loader Configuration window ................................................ 9-33
Data Loader Configuration window: advanced .............................. 9-38
Data Loader Configuration window: general .................................. 9-34
Data Loader Configuration window: logging .................................. 9-37
Data Loader Configuration window: restore defaults ..................... 9-38
Data/Software fails an integrity check .......................................... 10- 5
Data/Software not shown in Select Data/Software to Import
Window ..................................................................................... 10- 4
Data/software, downloading ........................................................... 7- 3
Data/software, importing ................................................................ 7- 4
Data/software, uploading ................................................................ 7- 1
Dataload failure encountered: Communication/transmission
error .......................................................................................... 10- 6
Dataload failure encountered: File missing .................................. 10- 5
Dataload failure encountered: Timeout/counter error .................. 10- 6
Dataload Network Adapter Settings Window, configure ................. 6- 2
Dataload Network Adapter Window: select .................................... 6- 1
DBU Tab ......................................................................................... 9-44
Delete log files ................................................................................ 9-38
Downloading data/software ............................................................ 7- 3

E
Error occurred during import ........................................................ 10- 4
Exiting CPAS-3000 Window ........................................................... 9- 5

F
File missing .................................................................................. 10- 5
File Progress bar ............................................................................ 9-15
File Server Unit: overview .............................................................. 2- 1
FSU tab .......................................................................................... 9-39
FSU: See File Server Unit .............................................................. 2- 1

2nd Edition
Index-2 6 Jun 08
CPAS-3000 Data Loader OPERATOR’S GUIDE
Data Loading Software For Windows Index

Subject Page

H
Hard drive: loading from ................................................................. 9-13
Help information ............................................................................. 9-53

I
Import button .................................................................................. 9-23
Importing data/software .................................................................. 7- 4
Installation failure: CPAS-3000 Data Loader ................................ 10- 1
Installed data/software not shown in the Manage window ........... 10- 3
Installing CPAS-3000 Data Loader ................................................. 4- 1
Installing CPAS-3000 Data Loader: items needed ......................... 3- 2
Installing CPAS-3000 Data Loader: setup ...................................... 3- 2
Insufficient hard drive memory ..................................................... 10- 1
Integrity Check: Data/Software Fails ............................................ 10- 5
Introduction: CPAS-3000 Data Loader ........................................... 2- 1
IOC tab ........................................................................................... 9-51

L
Launch Pad. See CPAS-3000 Launch Pad .................................... 3- 2
Limitations of program .................................................................... 8- 1
Load direction ................................................................................. 9- 9
Load From Hard Drive .................................................................... 9-13
Load state icons ............................................................................. 9-14
Load, status of ................................................................................ 9-14
Loading, begin ................................................................................ 9-13
Loading, cancel .............................................................................. 9-15
Loading: from hard drive ................................................................ 9-13
Log detailed load information ......................................................... 9-38
Log file ............................................................................................ 9-37
Log file directory ............................................................................. 9-38

M
Manage data/software window ....................................................... 7- 4
Manage Data/Software Window ..................................................... 9-21
Manage Data/Software Window: import ......................................... 9-23
Manage Data/Software Window: remove ....................................... 9-22

N
Network tab .................................................................................... 9-49

2nd Edition
6 Jun 08 Index-3
OPERATOR’S GUIDE CPAS-3000 Data Loader
Index Data Loading Software For Windows

Subject Page
No targets available to update ...................................................... 10- 1

O
Operation, program ........................................................................ 9- 1
Optional Pop-Up Windows ............................................................. 9-19
Overall Progress bar ...................................................................... 9-15

P
Package contents: CPAS-3000 Data Loader ................................. 3- 2
PC Network Adapter Window: selecting ........................................ 6- 1
Program operation .......................................................................... 9- 1
Program operation: supported functions ........................................ 9- 1
Program: limitations of ................................................................... 8- 1

Q
Quick Start Checklist Window ........................................................ 9- 6
Quick Start procedures ................................................................... 7- 1
Quick Start Tips window ................................................................. 9- 2

R
Refresh ........................................................................................... 9-28
Remove button ............................................................................... 9-22
Restore 615A Defaults button ........................................................ 9-44
Restore DBU Defaults button ......................................................... 9-46
Restore Defaults button .................................................................. 9-38
Restore FSU Defaults button ......................................................... 9-42
Restore Network Defaults button ................................................... 9-49

S
Screen savers: disabling .............................................................. 10- 7
Select Data/Software to be Updated .............................................. 9-11
Select Target/LRU To Be Updated ................................................. 9-10
Select the Dataload Network Adapter Window .............................. 6- 1
Select the PC Network Adapter ...................................................... 6- 1
Setup: CPAS-3000 Data Loader .................................................... 3- 2
Show All Optional Pop-Up Windows .............................................. 9-35
Show Detailed Information ............................................................. 9-17
Show tool tips ................................................................................. 9-35
Sleep mode: disabling .................................................................. 10- 7

2nd Edition
Index-4 6 Jun 08
CPAS-3000 Data Loader OPERATOR’S GUIDE
Data Loading Software For Windows Index

Subject Page
Starting CPAS-3000 Data Loader .................................................. 4- 2
Starting CPAS-3000 Window .......................................................... 9- 4
Status tabs ..................................................................................... 9-14
Support: CPAS-3000 Data Loader ................................................. 9-53
System requirements for CPAS-3000 Data Loader ........................ 3- 1

T
Tab, 615-3 ...................................................................................... 9-46
Tab, 615A ....................................................................................... 9-42
Target information ........................................................................... 9-32
Target Information window: 615A ................................................... 9-32
Target/LRU missing from the update list ...................................... 10- 2
Timeout/counter error ................................................................... 10- 6
Troubleshooting: Dataload failure encountered ........................... 10- 5
Troubleshooting: Installed data/software not shown in the Manage
window ...................................................................................... 10- 3
Troubleshooting: insufficient hard drive memory .......................... 10- 1
Troubleshooting: no targets available to update .......................... 10- 1
Troubleshooting: other notes ....................................................... 10- 7
Troubleshooting: screen savers, sleep mode .............................. 10- 7
Troubleshooting: Target/LRU missing from the update list .......... 10- 2
Troubleshooting: Unable to import a data/software item .............. 10- 3
Troubleshooting: unable to register the COM objects .................. 10- 1
Troubleshooting: virus protection software .................................. 10- 7

U
Unable to import a data/software item: Data/Software not
shown ....................................................................................... 10- 4
Unable to import a data/software item: Error occurred during the
import ........................................................................................ 10- 4
Unable to register the COM objects ............................................. 10- 1
Uninstalling CPAS-3000 Data Loader ............................................ 4- 2
Unlock software window: CPAS-3000 Data Loader ....................... 5- 1
Uploading data/software ................................................................. 7- 1

V
View configuration .......................................................................... 9-33
Virus protection: disabling ............................................................ 10- 7

2nd Edition
6 Jun 08 Index-5
OPERATOR’S GUIDE CPAS-3000 Data Loader
Index Data Loading Software For Windows

Subject Page
W
Window controls: CPAS-3000 Data Loader ................................... 9- 8

2nd Edition
Index-6 6 Jun 08
This page intentionally left blank
523-0810629-002117
© Copyright 2008, Rockwell Collins, Inc.,
All Rights Reserved, Printed in USA