MAGNETIC PARTICLEINSPECTION REPORT
   
Project: WELDING PROCEDURE QUALIFICATION TEST
 
Report No.: MEL-WQ-VIS-013
 
Date: 15/02/2022
 
Client: MELCO ENGINEERING PTY LTD
 
Job No.: JN-23195DK
 
Item Description: WELDING PROCEDURE QUALIFICATION
   

This report contains Inspection result related to Results of examination are detailed in Table 1 of
this report. All measurements provided in millimetres unless stated otherwise. was undertaken
and examined to the requirements of AS 1171-1998 AS/NZS 1554.1 2014 for l assessment
compliance of welding cracks defects.
 
a. Test Standard: AS 1171-1998
b. Inspection Codes: AS/NZS1554.1 SP
c. Technique: Magnetic Flow
d. Current Type: Sustained
e. Magnet: AC yoke MT48
f. Media: Sustained
g. Material: Carbon Steel NFS
h. Surface Condition: As welded / Flush ground
i. Features observed: See Remarks (if any)
j. Place of Inspection: Melco Engineering Workshop, Paget
 
 
Remarks:

This inspection was done in-house according to requirements in AS1171 -2018, but without Nata-certified
requirements

Examined by:

Name: OSCAR PEREZ (CSWIP 3.1 - 773075)

Signature:

Page 1 of 2
Date: 14/02/2023
Item examined Defects detected: Interpretation

Head 1 circumferential mpi


Cracks Refer to Photograps 1 to 4 Does not comply
100 %
Head 2 circumferential mpi
100 % Cracks Refer to Photograps4 to 6 Does not comply
Manhole face 1

Manhole face 2 Defects detected: Porosity x Does not comply


Longitudinal 1 No discontinuities detected Complies
Longitudinal 2 exceeding acceptance criteria Complies

Page 2 of 2