R22 MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Elegant Plus
ǀƸǤȤLjȚ ǀƴƫƱƶƵȮŽȚ ȔȚǞƷŽȚ ǗƸƸƳů ȜǎƷűȖ
ǀƂźNjůNjƁǍƃů 53QFJ 36-48
ǓƲźNjƁǍƃů 53KFJT 60

ȝƾȮƃȮƸȮżǍƄȮŽȚ ǚȮȮƸȮŽȢ
.ȜȢǞƐȚȝƾƁǞƄƉžǟƴŸȖǟƴŸȲǞƫƇƴŽȰȚǞŴLjȚȝƾűƾƸƄŲȘȶǀƸŽȶNjŽȚȶǀƸƴƤȚȝƾƱǧȚǞƵƴŽȹƾƲƃŶƾƷůƾƆƄƶƓǍƵƄƉƓȚǍƁǞƭƄŽƾŮǍƸƁȤƾżȳǞƲů
.ǍƸƁȤƾƳŽǍƵƄƉƵȮŽȚǍƁǞƭƄŽȚǀŴƾƸƉŽȹƾƲƃŶǘƃƉžȤƾƭųȘȴȶNjŮǃƄƶƵȮŽȚȝƾƱǧȚǞžǍƸƸưůǟźƾƷƲƇŮǍƸƁȤƾżǔƱƄƇȮůƾƵż

Safety Enviromental Quality


Management System Management System Management System
BS OHSAS 18001 : 2007 ISO 14001 : 2004 ISO 9001 : 2008
03503923 Certificate No : 12 116 30334 TMS Certificate No : 12 104 30334 TMS Certificate No.: QS-5519HH
Rev. (0) - 2015
‫ﻓﻬﺮس اﻟﻤﺤﺘﻮﻳﺎت‬
‫رﻗﻢ اﻟﺼﻔﺤﺔ‬
‫‪١‬‬ ‫ﻣﻌﻠﻮﻣﺎت ﻋﺎﻣﺔ إﻟﻰ ﻓﻨﻲ اﻟﺘﺮآﻴﺒﺎت‬ ‫‪- ١‬‬

‫‪٢‬‬ ‫اﺣﺘﻴﺎﻃﺎت ﻗﺒﻞ اﻟﺘﺮآﻴﺐ‬ ‫‪- ٢‬‬

‫‪٣‬‬ ‫وﺻﻒ ﻧﻈﺎم ﺟﻬﺎز ﺗﻜﻴﻴﻒ اﻟﻬﻮاء اﻟﺤﺎﺋﻄﻲ اﻟﻤﻨﻔﺼﻞ‬ ‫‪- ٣‬‬

‫‪٤‬‬ ‫اﻟﻤﻮدﻳﻼت‬ ‫‪-٤‬‬

‫‪٤‬‬ ‫ﺣﺪود ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻒ‬ ‫‪-٥‬‬

‫‪٥‬‬ ‫أﺑﻌﺎد ووزن اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫‪- ٦‬‬

‫‪٥‬‬ ‫أﺑﻌﺎد ووزن اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫‪-٧‬‬

‫‪٦‬‬ ‫اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫‪-٨‬‬

‫‪٨‬‬ ‫اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫‪-٩‬‬

‫‪١٥‬‬ ‫ﻗﺎﺋﻤﺔ ﻓﺤﻮﺻﺎت اﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ‬ ‫‪-١٠‬‬

‫‪١٦‬‬ ‫ﻣﻠﺤﻘﺎت اﻟﺘﺮآﻴﺒﺎت‬ ‫‪- ١١‬‬

‫‪١٨‬‬ ‫ﺧﺮﻳﻄﺔ ﺗﺮﺗﻴﺐ أﻋﻤﺎل اﻟﺘﺮآﻴﺒﺎت‬ ‫‪-١٢‬‬

‫‪١٩‬‬ ‫ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫‪-١٣‬‬

‫‪٢٠‬‬ ‫ﺗﺮآﻴﺐ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬ ‫‪-١٤‬‬

‫‪٢١‬‬ ‫ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫‪-١٥‬‬

‫‪٢٢‬‬ ‫ﺗﻮﺻﻴﻼت وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬ ‫‪-١٦‬‬

‫‪٣٥‬‬ ‫ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬ ‫‪-١٧‬‬

‫‪٣٦‬‬ ‫اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫‪-١٨‬‬

‫‪٤٢‬‬ ‫إﻧﻬﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬ ‫‪-١٩‬‬

‫‪٤٣‬‬ ‫اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ﺑﻌﺪ اﻧﺘﻬﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬ ‫‪-٢٠‬‬

‫‪٤٥‬‬ ‫ﻗﺎﺋﻤﺔ ﻓﺤﻮﺻﺎت ﻣﺎ ﺑﻌﺪ اﻟﺘﺮآﻴﺒﺎت‬ ‫‪-٢١‬‬

‫‪٤٧‬‬ ‫وﻇﻴﻔﺔ اﻟﺘﺸﻐﻴﻞ اﻟﺬاﺗﻰ ﻹآﺘﺸﺎف اﻷﻋﻄﺎل‬ ‫‪-٢٢‬‬

‫‪٠‬‬
‫‪ -١‬ﻣﻌﻠﻮﻣﺎت ﻋﺎﻣﺔ إﻟﻰ ﻓﻨﻰ اﻟﺘﺮآﻴﺒﺎت‬
‫ﺟﻬﺎز ﺗﻜﻴﻴﻒ اﻟﻬﻮاء ﺗﻢ ﺗﺼﻤﻴﻤﻪ ﺑﻌﻨﺎﻳﺔ ودﻗﺔ وﺗﻢ ﺗﺼﻨﻴﻌﻪ ﺑﺎﻟﺠﻮدة اﻟﻤﻄﻠﻮﺑﺔ‪.‬‬
‫ﻟﺬا ﻓﻘﺪ أﺻﺒﺢ ﻟﺰاﻣﺎ ﻋﻠﻴﻚ ﺗﺮآﻴﺐ اﻟﺠﻬﺎز وﺗﺸﻐﻴﻠﻪ ﺑﻌﻨﺎﻳﺔ ودﻗﺔ وﺗﺸﻄﻴﺐ أﻋﻤﺎل اﻟﺘﺮآﻴﺒﺎت ﺑﺎﻟﺸﻜﻞ اﻟﺠﻤﺎﻟﻰ وﻣﺴﺘﻮى اﻟﺠﻮدة‬
‫اﻟﺬى ﻳﺤﻘﻖ رﻏﺒﺎت اﻟﻌﻤﻼء ‪ ،‬آﻤﺎ ﻳﺠﺐ ﻋﻠﻴﻚ إرﺷﺎد اﻟﻌﻤﻴﻞ إﻟﻰ ﻃﺮﻳﻘﺔ ﺗﺸﻐﻴﻞ اﻟﺠﻬﺎز ﻣﺴﺘﺮﺷﺪًا ﺑﺪﻟﻴﻞ ﺗﻌﻠﻴﻤﺎت اﻟﺘﺸﻐﻴﻞ‪.‬‬
‫ﺑﺮﺟﺎء ﻗﺮاءة هﺬا اﻟﺪﻟﻴﻞ ﻣﻊ اﻻﺣﺘﻔﺎظ ﺑﻪ ﻟﻠﺮﺟﻮع إﻟﻴﻪ ﻋﻨﺪ اﻟﺤﺎﺟﺔ ﺣﻴﺚ أﻧﻪ ﻳﺸﺘﻤﻞ ﻋﻠﻰ ﺗﻌﻠﻴﻤﺎت اﻟﺘﺮآﻴﺒﺎت اﻟﺘﻰ ﺗﻀﻤﻦ‬
‫آﻔﺎءة ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وإﻃﺎﻟﺔ ﻋﻤﺮﻩ‪.‬‬

‫ﺗﺄآﺪ ﻣﻦ وﺟﻮد ﻣﻠﺤﻘﺎت اﻟﺘﺮآﻴﺐ ﻣﻊ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻗﺒﻞ اﻟﺒﺪء ﻓﻰ ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺐ‬

‫ﺳﻮف ﺗﺤﺘﺎج اﻟﻌﺪد واﻟﻤﻌﺪات اﻟﺘﺎﻟﻴﺔ أﺛﻨﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺐ‪:‬‬


‫ﻋﺪة ﻓﻠﻴﺮ‬ ‫‪.١٠‬‬ ‫ﻣﻔﻚ ﻋﺎدى‬ ‫‪.١‬‬
‫ﻋﺪة ﺛﻨﻲ اﻟﻤﻮاﺳﻴﺮ‬ ‫‪.١١‬‬ ‫ﻣﻔﻚ ﺻﻠﻴﺒﺔ‬ ‫‪.٢‬‬
‫ﻣﻔﺘﺎح رﺑﺎط ﻣﺴﺪس‬ ‫‪.١٢‬‬ ‫ﻣﺜﻘﺎب‬ ‫‪.٣‬‬
‫ﻣﻔﺘﺎح رﺑﺎط ﻟﻘﻴﺎس ﻋﺰم اﻟﺪوران‬ ‫‪.١٣‬‬ ‫ﻣﺘﺮ ﻗﻴﺎس‬ ‫‪.٤‬‬
‫ﻃﻠﻤﺒﺔ ﺗﻔﺮﻳﻎ اﻟﻬﻮاء واﻟﺮﻃﻮﺑﺔ‬ ‫‪.١٤‬‬ ‫ﻣﻴﺰان ﻣﻴﺎﻩ‬ ‫‪.٥‬‬
‫ﺟﻬﺎز إآﺘﺸﺎف ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن‬ ‫‪.١٥‬‬ ‫آﻼﺑﺔ ﻣﻮاﺳﻴﺮ‬ ‫‪.٦‬‬
‫ﺟﻬﺎز ﻗﻴﺎس ﺿﻐﻮط اﻟﻔﺮﻳﻮن‬ ‫‪.١٦‬‬ ‫ﻗﺎﻃﻌﺔ ﻣﻮاﺳﻴﺮ‬ ‫‪.٧‬‬
‫ﺛﺮﻣﻮﻣﻴﺘﺮ‬ ‫‪.١٧‬‬ ‫ﻣﻔﺎﺗﻴﺢ رﺑﻂ‬ ‫‪.٨‬‬
‫ﺟﻬﺎز اﺧﺘﺒﺎر اﻟﺪاﺋﺮة اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫‪.١٨‬‬ ‫ﻣﻮﺳﻊ ﺛﻘﻮب ﻟﺘﻨﻈﻴﻒ اﻟﻤﻮاﺳﻴﺮ‬ ‫‪.٩‬‬

‫ﻋﻨﺪ إﺗﻤﺎم ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت واﻻﺧﺘﺒﺎر ﻳﺠﺐ أن ﺗﻮﺿﺢ ﻟﻠﻌﻤﻴﻞ ﻃﺮﻳﻘﺔ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وإﺟﺮاءات‬
‫اﻟﺼﻴﺎﻧﺔ اﻟﺪورﻳﺔ ﻟﻠﺠﻬﺎز وﻳﺘﻢ اﻟﺘﺮآﻴﺰ ﻋﻠﻰ‪:‬‬

‫ﻃﺮﻳﻘﺔ ﻓﻚ وﺗﻨﻈﻴﻒ ﻓﻼﺗﺮ اﻟﻬﻮاء‪.‬‬ ‫•‬ ‫ﻃﺮﻳﻘﺔ ﺗﺸﻐﻴﻞ وإﻳﻘﺎف ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬ ‫•‬

‫ﻃﺮﻳﻘﺔ إﻋﺎدة ﺗﺮآﻴﺐ ﻓﻼﺗﺮ اﻟﻬﻮاء ﻓﻰ اﻟﻮﺣﺪة ﺑﻌﺪ ﺗﻨﻈﻴﻔﻬﺎ‪.‬‬ ‫•‬ ‫وﻇﺎﺋﻒ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬ ‫•‬

‫أﺗﺮك دﻟﻴﻞ ﺗﻌﻠﻴﻤﺎت اﻟﺘﺸﻐﻴﻞ ﻟﻠﻌﻤﻴﻞ ﻟﻼﺳﺘﺮﺷﺎد ﺑﻪ ﻋﻨﺪ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ واﺗﺮك أﻳﻀ ًﺎ دﻟﻴﻞ اﻟﺘﺮآﻴﺒﺎت ﻟﻠﻌﻤﻴﻞ‪.‬‬
‫آﻤﺎ أﻧﻪ ﻳﺠﺐ ﻋﻠﻴﻚ إرﺷﺎد اﻟﻌﻤﻴﻞ ﺑﺎﻟﻨﻘﺎط اﻟﺘﻰ ﺗﻘﻠﻞ اﻟﺤﻤﻞ اﻟﺤﺮارى داﺧﻞ اﻟﻐﺮﻓﺔ اﻟﻤﻜﻴﻔﺔ ﻟﻠﺤﺼﻮل ﻋﻠﻰ أﺣﺴﻦ أداء ﻟﺠﻬﺎز‬
‫اﻟﺘﻜﻴﻴﻒ آﻤﺎ هﻮ ﻣﻮﺿﺢ ﻓﻲ دﻟﻴﻞ ﺗﻌﻠﻴﻤﺎت اﻟﺘﺸﻐﻴﻞ‪.‬‬

‫‪١‬‬
‫‪ -٢‬اﺣﺘﻴﺎﻃﺎت ﻗﺒﻞ اﻟﺘﺮآﻴﺐ‬

‫اﺣﺘﻴﺎﻃﺎت اﻷﻣــــﺎن‬

‫• ﺗﺮآﻴﺐ وﺻﻴﺎﻧﺔ أﺟﻬﺰة اﻟﺘﻜﻴﻴﻒ ﻳﻤﻜﻦ أن ﻳﻨﻄﻮى ﻋﻠﻰ ﻣﺨﺎﻃﺮة ﻻﺣﺘﻮاء ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻋﻠﻰ ﺿﻐﻂ ﻓﺮﻳﻮن وﻣﻜﻮﻧﺎت آﻬﺮﺑﻴﺔ‬
‫واﺟﺰاء ﻣﺘﺤﺮآﺔ‪.‬‬
‫• ﻳﺠﺐ أن ﻳﺘﻢ ﺗﺮآﻴﺐ وﺻﻴﺎﻧﺔ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺑﻮاﺳﻄﺔ ﻓﻨﻴﻴﻦ ﻣﺪرﺑﻴﻦ وﻣﺆهﻠﻴﻦ ﻣﻦ آﺎرﻳﻴﺮ أو أﺣﺪ ﻣﻮزﻋﻴﻬﺎ اﻟﻤﻌﺘﻤﺪﻳﻦ‪.‬‬
‫• ﺑﻌﺪ ﻓﻚ ﺗﻐﻠﻴﻒ آﻞ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ واﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ ﻋﺪم وﺟﻮد أي ﺗﻠﻒ ﺑﻬﺪذﻩ اﻟﻮﺣﺪات‪.‬‬
‫• ﻗﺒﻞ إﺟﺮاء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺐ واﻟﺼﻴﺎﻧﺔ ﻷي ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ أو اﻟﺨﺎرﺟﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻳﺠﺐ ﻓﺼﻞ ﻣﺼﺪر اﻟﺘﻴﺎر‬
‫اﻟﻜﻬﺮﺑﺎﺋﻲ ﻋﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫!‬ ‫ﺗﺤﺬﻳﺮ‬

‫ﻳﺼﻒ هﺬا اﻟﺪﻟﻴﻞ ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت اﻟﺨﺎﺻﺔ ﺑﺠﻬﺎز ﺗﻜﻴﻴﻒ اﻟﻬﻮاء اﻟﻤﻨﻔﺼﻞ اﻟﻤﻜﻮن ﻣﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫•‬
‫واﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ اﻟﻤﺘﻮاﻓﻘﺔ واﻟﻤﺼﻨﻌﺔ ﺑﻤﺼﺎﻧﻊ آﺎرﻳﻴﺮ‪.‬‬
‫ﺗﺘﻢ ﻋﻤﻠﻴﺎت ﺗﺮآﻴﺐ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻃﺒﻘ ًﺎ ﻟﻠﻤﻮاﺻﻔﺎت اﻟﻤﺤﻠﻴﺔ‪.‬‬ ‫•‬
‫ﻓﻲ ﺣﺎﻟﺔ اﻟﺘﺮآﻴﺐ ﻳﺠﺐ اﻹﻧﺘﻬﺎء ﻣﻦ إﺗﻤﺎم ﺗﻮﺻﻴﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ ﻗﺒﻞ اﻟﻘﻴﺎم‬ ‫•‬
‫ﺑﺎﻋﻤﺎل اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ وﻓﻲ ﺣﺎﻟﺔ اﻟﺨﺪﻣﺔ واﻟﺼﻴﺎﻧﺔ ﻳﻜﻮن اﻟﻌﻜﺲ‪.‬‬

‫ﻣﺎ اﻟﺬى ﻻ ﺗﺘﻀﻤﻨﻪ ﺷﻬﺎدة ﺿﻤﺎن ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ؟‬


‫‪ -١‬اﻷﺿﺮار اﻟﻨﺎﺗﺠﺔ ﻣﻦ ﻣﺸﺎآﻞ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﻃﺌﺔ ﺑﻴﻦ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻲ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬
‫واﻟﺘﻲ ﺗﺆدي إﻟﻰ ﺣﺪوث ﺣﺎﻻت اﻟﻘﺼﺮ اﻟﻜﻬﺮﺑﺎﺋﻲ واﻟﺤﺮﻳﻖ ﺣﻴﺚ أن هﺬﻩ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ هﻲ ﻣﺴﺌﻮﻟﻴﺔ‬
‫اﻟﻤﺸﺘﺮى‪.‬‬
‫‪ -٢‬اﻷﺿﺮار اﻟﻨﺎﺗﺠﺔ ﻣﻦ ﺳﻮء اﻻﺳﺘﺨﺪام ) اﻹهﻤﺎل – اﻟﺤﻤﻞ اﻟﺰاﺋﺪ – ﻋﺪم ﺗﻨﻈﻴﻒ ﻓﻼﺗﺮ اﻟﻬﻮاء‪ -‬ﻋﺪم اﻹﻟﺘﺰام ﺑﺘﻌﻠﻴﻤﺎت‬
‫اﻟﺘﺸﻐﻴﻞ اﻟﻤﻮﺿﺤﺔ ﻓﻲ دﻟﻴﻞ اﻟﺘﺸﻐﻴﻞ اﻟﻤﺮﻓﻖ ﻣﻊ اﻟﻤﻨﺘﺞ (‪.‬‬
‫‪ -٣‬اﻷﺿﺮار اﻟﻨﺎﺗﺠﺔ ﻋﻦ ﺣﻮادث اﻟﻄﻘﺲ ) ﺳﻮء اﻷﺣﻮال اﻟﺠﻮﻳﺔ – ﻋﻮاﺻﻒ اﻟﺒﺮد – اﻟﻌﻮاﺻﻒ اﻟﺮﻣﻠﻴﺔ – اﻟﺒﺮق –‬
‫اﻟﻔﻴﻀﺎﻧﺎت – اﻷﻣﻄﺎر اﻟﺤﻤﻀﻴﺔ – أي ﺗﺴﺎﻗﻂ ﻣﻦ اﻟﺠﻮ ‪ ..... -‬إﻟﺦ (‪.‬‬
‫‪ -٤‬اﻷﺿﺮار اﻟﻨﺎﺗﺠﺔ ﻣﻦ ﻧﻘﻞ ﺧﺎﻃﺊ ﻟﻠﻤﻨﺘﺞ اﻟﺬى ﺗﻢ ﺑﻤﻌﺮﻓﺔ اﻟﻤﺸﺘﺮى‪.‬‬
‫‪ -٥‬اﻷﺿﺮار اﻟﻨﺎﺗﺠﺔ ﻣﻦ أى ﺗﻌﺪﻳﻞ ﻋﻠﻰ اﻟﻤﻨﺘﺞ ﺗﻢ ﺑﻤﻌﺮﻓﺔ اﻟﻤﺸﺘﺮى‪.‬‬
‫‪ -٦‬اﻷﺿﺮار اﻟﻨﺎﺗﺠﺔ ﻣﻦ أﻋﻤﺎل ﺗﺮآﻴﺐ أو ﺧﺪﻣﺔ وﺻﻴﺎﻧﺔ أو إﺻﻼح ﺗﻤﺖ ﺑﻤﻌﺮﻓﺔ اﻟﻤﺸﺘﺮى‪.‬‬
‫‪ -٧‬اﻟﺼﻮت اﻟﻄﺒﻴﻌﻲ اﻟﺼﺎدر ﻣﻦ اﻟﺠﻬﺎز ) ﻏﺎز اﻟﺘﺒﺮﻳﺪ – اﻷﺟﺰاء اﻟﻤﺘﺤﺮآﺔ (‪.‬‬
‫‪ -٨‬اﻹزﻋﺎج أو اﻟﻀﻴﻖ أو اﻟﺨﺴﺎرة اﻟﺘﺠﺎرﻳﺔ‪.‬‬
‫ﻗﺮار آﺎرﻳﻴﺮ ﻓﻲ اﻟﺘﺤﻘﻖ ﻣﻦ أﺳﺒﺎب اﻷﺿﺮار اﻟﻤﺬآﻮرة أﻋﻼﻩ وﺗﺤﺪﻳﺪهﺎ ﻳﻌﺘﺒﺮ ﻧﻬﺎﺋﻴ ًﺎ ‪ ،‬وﻓﻲ هﺬﻩ اﻟﺤﺎﻟﺔ ﻓﺈن‬
‫أي إﺻﻼﺣﺎت أو اﺳﺘﺒﺪال ﻟﻸﺟﺰاء اﻟﺘﺎﻟﻔﺔ ﺳﻴﻜﻮن ﻋﻠﻰ ﺣﺴﺎب اﻟﻤﺸﺘﺮى‪.‬‬

‫‪٢‬‬
‫‪ -٣‬وﺻﻒ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬

‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬

‫‪١‬‬ ‫‪٣‬‬
‫‪١٠‬‬ ‫‪٤‬‬
‫‪٢‬‬ ‫‪٥‬‬

‫‪٦‬‬

‫‪٧‬‬ ‫‪٩‬‬ ‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬

‫‪٨‬‬

‫‪ :٢‬ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ اﻹﻟﻜﺘﺮوﻧﻴﺔ‬ ‫‪ :١‬اﻟﻬﻮاء اﻟﻤﻜﻴﻒ اﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪ :٤‬ﻣﻮﺟﻬﺎت اﻟﻬﻮاء اﻟﻤﻜﻴﻒ اﻷﻓﻘﻴﺔ‬ ‫‪ :٣‬ﻣﻮﺟﻬﺎت اﻟﻬﻮاء اﻟﻤﻜﻴﻒ اﻟﺮأﺳﻴﺔ‬

‫‪ :٦‬اﻟﻬﻮاء اﻟﺮاﺟﻊ ﻣﻦ اﻟﻐﺮﻓﺔ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫‪ :٥‬ﻣﻜﺎن وﺿﻊ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﻟﺤﻔﻈﻬﺎ‬
‫) ﻋﻠﻰ آﻞ ﺟﺎﻧﺐ (‬ ‫ﻣﻦ اﻟﻀﻴﺎع‬
‫‪ :٧‬وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن وآﺎﺑﻼت اﻟﺘﻮﺻﻴﻞ‬
‫‪ :٨‬ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬
‫اﻟﻜﻬﺮﺑﺎﺋﻰ‬

‫‪ :١٠‬وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬ ‫‪ :٩‬اﻟﻤﺤﺎﺑﺲ اﻟﻔﻠﻴﺮ ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪٣‬‬
‫‪ -٤‬اﻟﻤﻮدﻳﻼت‬

‫ﺗﺒﺮﻳﺪ ﻓﻘﻂ‬ ‫ﺗﺒﺮﻳﺪ ‪ /‬ﺗﺪﻓﺌﺔ‬


‫ﻣﻮدﻳﻞ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﻣﻮدﻳﻞ‬
‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬ ‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬
‫‪38KFJT60-508 42KFJT60-708 53KFJT60-508‬‬ ‫‪38QFJ36-708 42QFJ36-708‬‬ ‫‪53QFJ36-708‬‬
‫‪38QFJ48-508‬‬ ‫‪42QFJ48-708‬‬ ‫‪53QFJ48-508‬‬

‫ﻣﻼﺣﻈﺎت‪:‬‬
‫‪ = 53‬اﻟﺠﻬﺎز اﻟﻤﻨﻔﺼﻞ ﺑﺄآﻤﻠﻪ‬
‫‪ = 42‬اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪ = 38‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ = Q‬ﺗﺒﺮﻳﺪ ‪ /‬ﺗﺪﻓﺌﺔ ﺑﻨﻈﺎم اﻟﺪورة اﻟﻤﻌﻜﻮﺳﺔ‬
‫‪ = K‬ﺗﺒﺮﻳﺪ ﻓﻘﻂ‬
‫‪ = F‬ﻓﺮي ﺳﺘﺎﻧﺪ‬
‫= ﺷﻜﻞ اﻟﻮاﺟﻬﺔ اﻷﻣﺎﻣﻴﺔ ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫‪J‬‬
‫‪ = T‬اﻟﺠﻬﺎز ﻳﻌﻤﻞ ﻓﻰ اﻷﺟﻮاء اﻟﺤﺎرة‬
‫‪ ٢٤٠-٢٢٠ = 708‬ﻓﻮﻟﺖ ‪١ /‬ﻓﺎز ‪٥٠ /‬هﺮﺗﺰ‬
‫‪ ٤٢٠-٣٨٠ = 508‬ﻓﻮﻟﺖ ‪٣ /‬ﻓﺎز ‪٥٠ /‬هﺮﺗﺰ‬

‫‪ -٥‬ﺣﺪود اﻟﺘﺸﻐﻴﻞ‬

‫ﺗﺪﻓﺌﺔ‬ ‫ﺗﺒﺮﻳﺪ‬
‫درﺟﺔ اﻟﺤﺮارة‬ ‫درﺟﺔ اﻟﺤﺮارة‬ ‫درﺟﺔ اﻟﺤﺮارة‬ ‫درﺟﺔ اﻟﺤﺮارة‬
‫اﻻﺧﺘﻼف‬ ‫اﻻﺧﺘﻼف‬
‫اﻟﻤﺒﺘﻠﺔ م‪°‬‬ ‫اﻟﺠﺎﻓﺔ م‪°‬‬ ‫اﻟﻤﺒﺘﻠﺔ م‪°‬‬ ‫اﻟﺠﺎﻓﺔ م‪°‬‬
‫درﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺪاﺧﻠﻰ‬ ‫درﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺪاﺧﻠﻰ‬
‫‪-‬‬ ‫‪٢٧‬‬ ‫أﻗﺼﻰ ﻗﻴﻤﺔ‬ ‫‪٢٣‬‬ ‫‪٣٢‬‬ ‫أﻗﺼﻰ ﻗﻴﻤﺔ‬
‫‪١٥‬‬ ‫‪٢١‬‬ ‫أﻗﻞ ﻗﻴﻤﺔ‬
‫درﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺨﺎرﺟﻰ‬ ‫درﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺨﺎرﺟﻰ‬
‫‪١٨‬‬ ‫‪٢٤‬‬ ‫أﻗﺼﻰ ﻗﻴﻤﺔ‬ ‫‪-‬‬ ‫‪٤٦‬‬ ‫أﻗﺼﻰ ﻗﻴﻤﺔ‬
‫‪١‬‬ ‫‪٢‬‬ ‫أﻗﻞ ﻗﻴﻤﺔ‬ ‫‪-‬‬ ‫‪٢٠‬‬ ‫أﻗﻞ ﻗﻴﻤﺔ‬

‫ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ‬


‫أﻗﺼﻰ‬ ‫أﻗﻞ‬ ‫اﻟﻔﻮﻟﺖ اﻹﺳﻤﻰ‬
‫اﻻﺧﺘﻼف‬
‫ﻓﻮﻟﺖ‬ ‫ﻓﻮﻟﺖ‬ ‫ﻓﻮﻟﺖ ‪ /‬ﻓﺎز ‪ /‬هﻴﺮﺗﺰ‬
‫‪٢٦٤‬‬ ‫‪١٨٧‬‬ ‫‪٥٠ / ١ / ٢٤٠-٢٢٠‬‬ ‫‪53QFJ36-708‬‬
‫‪٤٦٢‬‬ ‫‪٣٤٢‬‬ ‫‪٥٠ / ٣ / ٤٢٠ -٣٨٠‬‬ ‫‪53QFJ48-508‬‬
‫‪٤٦٢‬‬ ‫‪٣٤٢‬‬ ‫‪٥٠ / ٣ / ٤٢٠ -٣٨٠‬‬ ‫‪53KFJT60-508‬‬

‫ﻣﻼﺣﻈﺎت‪:‬‬
‫ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻓﻰ ﺣﺪود أﻋﻠﻰ أو أﻗﻞ ﻣﻦ اﻟﻤﺬآﻮرة ﻓﺈن اﻟﺠﻬﺎز ﻻ ﻳﻌﻤﻞ ﺑﺤﺎﻟﺔ ﺟﻴﺪة‪.‬‬ ‫*‬
‫اﻟﺮﻃﻮﺑﺔ اﻟﻨﺴﺒﻴﺔ داﺧﻞ اﻟﻤﻜﺎن اﻟﻤﻄﻠﻮب ﺗﻜﻴﻴﻔﻪ ﺗﻜﻮن أﻗﻞ ﻣﻦ ‪%٨٠‬‬ ‫**‬
‫إذا ﺗﻢ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وآﺎﻧﺖ اﻟﺮﻃﻮﺑﺔ اﻟﻨﺴﺒﻴﺔ داﺧﻞ اﻟﻤﻜﺎن اﻟﻤﻄﻠﻮب ﺗﻜﻴﻴﻔﻪ أآﺒﺮ ﻣﻦ ‪ %٨٠‬ﻓﺈﻧﻪ ﻳﺠﺐ ﺿﺒﻂ زواﻳﺎ‬
‫اﻟﻤﻮﺟﻬﺎت اﻷﻓﻘﻴﺔ ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﺑﺤﻴﺚ ﺗﻜﻮن ﻋﻤﻮدﻳﺔ ﺑﺎﻟﻨﺴﺒﺔ ﻷرﺿﻴﺔ اﻟﻤﻜﺎن آﻤﺎ ﻳﺠﺐ ﺿﺒﻂ ﺳﺮﻋﺔ اﻟﻤﺮوﺣﺔ ﻋﻨﺪ اﻟﺴﺮﻋﺔ‬
‫اﻟﻌﺎﻟﻴﺔ‪ .‬وذﻟﻚ ﻟﺘﺠﻨﺐ ﺣﺪوث ﺗﻜﺜﻴﻔﻪ ﻟﻠﻤﻴﺎﻩ ﻋﻠﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫*** ﻳﻜﻮن أداء ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﺜﺎﻟﻴ ًﺎ ﻋﻨﺪ درﺟﺎت اﻟﺤﺮارة اﻟﻤﻮﺿﺤﺔ أﻋﻼﻩ‪.‬‬

‫‪٤‬‬
‫‪ -٦‬أﺑﻌـﺎد ووزن اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫ﺝ‬ ‫ﺃ‬ ‫اﻻﺑﻌﺎد )ﻣﻢ(‬

‫ﻜﺠﻡ‬

‫اﻟﻮزن‬ ‫اﻷﺑﻌﺎد ) ﻣﻢ (‬ ‫ﻣﻮدﻳﻞ‬


‫ﻧﻈﺎم‬
‫ﺏ‬ ‫ج‬ ‫ب‬ ‫أ‬ ‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪٥٨‬‬ ‫‪٤١٠‬‬ ‫‪١٨٢٥‬‬ ‫‪٥٤٠‬‬ ‫ﺗﺒﺮﻳﺪ ‪ /‬ﺗﺪﻓﺌﺔ‬ ‫‪42QFJ36-708‬‬

‫‪٥٨‬‬ ‫‪٤١٠‬‬ ‫‪١٨٢٥‬‬ ‫‪٥٤٠‬‬ ‫ﺗﺒﺮﻳﺪ ‪ /‬ﺗﺪﻓﺌﺔ‬ ‫‪42QFJ48-708‬‬

‫‪٥٩‬‬ ‫‪٣٩٠‬‬ ‫‪١٩٢٥‬‬ ‫‪٦١٠‬‬ ‫ﺗﺒﺮﻳﺪ ﻓﻘﻂ‬ ‫‪42KFJT60-708‬‬

‫‪ -٧‬أﺑﻌــــﺎد ووزن اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫اﻻﺑﻌﺎد )ﻣﻢ(‬ ‫ﻜﺠﻡ‬


‫اﻟﻮزن‬
‫آﺠﻢ‬ ‫اﻟﻤﻮدﻳﻞ‬
‫‪٧٩٫٥ 38QFJ36-708‬‬
‫‪٩٠‬‬ ‫‪38QFJ48-508‬‬
‫‪٩٢ 38KFJT60-508‬‬

‫‪38QFJ48-508‬‬ ‫‪38QFJ36-708‬‬
‫‪38KFJT60-508‬‬
‫‪٨٦٠‬‬

‫‪٨٦٠‬‬ ‫‪٣٥٠‬‬

‫‪١١٥٠‬‬ ‫‪٧٢٠‬‬

‫‪٦٦٥‬‬ ‫‪٣٨٤‬‬

‫‪٦٦٥‬‬ ‫‪٦٦٥‬‬
‫‪٩٧٫٥‬‬ ‫‪٣٨٤‬‬
‫‪٨٦٠‬‬
‫‪٣٧١‬‬

‫‪٣٥٠‬‬
‫‪٣٥٠‬‬
‫‪٣٧١‬‬

‫‪٥‬‬
‫‪ - ٨‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪ ١-٨‬اﻋﺘﺒﺎرات اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪ ٥٠‬ﻤﻡ‬
‫ﺃﻭ ﺃﻜﺜﺭ‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺴﻤﺢ ﺑﺤﺮﻳﺔ ﺣﺮآﺔ‬


‫اﻟﻬﻮاء اﻟﺪاﺧﻞ واﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وﻳﺴﻤﺢ‬
‫ﺑﺴﻬﻮﻟﺔ ﻋﻤﻠﻴﺎت اﻟﺨﺪﻣﺔ واﻟﺼﻴﺎﻧﺔ‪.‬‬
‫‪ ٥٠٠‬ﻤﻡ‬ ‫‪ ٥٠٠‬ﻤﻡ‬
‫ﺃﻭ ﺃﻜﺜﺭ‬ ‫ﺃﻭ ﺃﻜﺜﺭ‬
‫‪ ٢٠٠٠‬ﻤﻡ ﺃﻗل ﻤﺴﺎﻓﺔ ﺃﻤﺎﻡ ﻭﺍﺠﻬﺔ ﺍﻟﻭﺤﺩﺓ‬

‫ﻤﻜﺎﻥ ﺍﻟﺨﺭﻭﺝ ﻤﻥ ﺍﻟﺠﺎﻨﺏ ﺍﻷﻴﻤﻥ ﺃﻭ ﺍﻟﺠﺎﻨﺏ ﺍﻷﻴﺴﺭ ﻟﻠﻭﺤﺩﺓ‬

‫ﻓﺘﺤﺔ ﺨﺭﻭﺝ‬ ‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺴﻤﺢ ﻳﺘﻮاﻓﻖ ﻓﺘﺤﺔ‬


‫ﻓﺘﺤﺔ ﺨﺭﻭﺝ‬ ‫ﻭﺼﻼﺕ ﺍﻟﻤﻭﺍﺴﻴﺭ‬ ‫اﻟﺤﺎﺋﻂ اﻟﺨﺎﺻﺔ ﻣﻊ أﻣﺎآﻦ ﺧﺮوج ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫ﺍﻟﻜﺎﺒﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ‬ ‫ﻭﺨﺭﻁﻭﻡ ﺘﺼﺭﻴﻑ ﺍﻟﻤﻴﺎﻩ‬ ‫واﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ ﻣﻦ‬
‫ﻗﻁﺭ ﺍﻟﻔﺘﺤﺔ ‪٣٥‬ﻤﻡ‬ ‫ﻗﻁﺭ ﺍﻟﻔﺘﺤﺔ ‪ ٨٠‬ﻤﻡ‬ ‫ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻣﻦ أﺣﺪ اﻷﻣﺎآﻦ اﻟﻤﺒﻴﻨﺔ ﻟﻠﺮﺳﻢ‪.‬‬

‫• ﺗﺠﻨﺐ اﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ أن ﺗﻜﻮن‬


‫ﻤﻜﺎﻥ ﺍﻟﺨﺭﻭﺝ ﻤﻥ ﺨﻠﻑ ﺍﻟﻭﺤﺩﺓ‬ ‫ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ ﻓﻰ ﻋﻤﻮد أو آﻤﺮ ﺧﺮﺳﺎﻧﻰ‪.‬‬
‫• ﺗﺠﻨﺐ اﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ أن ﺗﻘﻄﻊ‬
‫ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ أﻳﺔ ﺧﻄﻮط ﺗﻐﺬﻳﺔ آﻬﺮﺑﺎﺋﻴﺔ أو ﻣﻮاﺳﻴﺮ‬
‫داﺧﻞ اﻟﺤﺎﺋﻂ‪.‬‬

‫ﻓﺘﺤﺔ ﺨﺭﻭﺝ‬
‫ﻭﺼﻼﺕ ﺍﻟﻤﻭﺍﺴﻴﺭ‬
‫ﻓﺘﺤﺔ ﺨﺭﻭﺝ ﺍﻟﻜﺎﺒﻼﺕ‬ ‫ﻭﺨﺭﻁﻭﻡ ﺘﺼﺭﻴﻑ ﺍﻟﻤﻴﺎﻩ‬
‫ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﻗﻁﺭ ﺍﻟﻔﺘﺤﺔ ‪٣٥‬ﻤﻡ‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ اﻟﻄﻮل‬


‫اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﻟﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻴﻦ‬
‫اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ اﻻرﺗﻔﺎع‬


‫اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫‪٦‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﺗﺎﺑﻊ ‪ -‬اﻋﺘﺒﺎرات اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪ ٣٠٠‬ﻤﻡ‬
‫ﺃﻭ ﺃﻜﺜﺭ‬
‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺴﻤﺢ أن ﺗﻐﻄﻰ اﻟﻮﺣﺪة‬
‫اﻟﺪاﺧﻠﻴﺔ أآﺒﺮ ﺟﺰء ﻣﻦ اﻟﻐﺮﻓﺔ ﺑﺎﻟﻬﻮاء اﻟﻤﻜﻴﻒ‬
‫اﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺘﻌﺮض ﻷﺷﻌﺔ‬


‫اﻟﺸﻤﺲ اﻟﻤﺒﺎﺷﺮة‪.‬‬
‫ﻓﻰ ﺣﺎﻟﺔ ﺗﻌﺮض اﻟﻤﻜﺎن ﻟﻀﻮء اﻟﺸﻤﺲ ﻳﺘﻢ اﺳﺘﺨﺪام‬
‫واﻗﻴﺎت اﻟﺸﻤﺲ آﺎﻟﺤﻮاﺟﺰ واﻟﺴﺘﺎﺋﺮ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺘﻌﺮض ﻷﻳﺔ‬


‫ﻣﺼﺎدر ﺣﺮارﻳﺔ ﺗﺆﺛﺮ ﺑﺎﻟﺴﻠﺐ ﻋﻠﻰ أداء اﻟﻮﺣﺪة‪.‬‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺴﻤﺢ ﺑﺤﺮﻳﺔ ﺣﺮآﺔ‬


‫اﻟﻬﻮاء ﺣﻮل اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫ﺗﺠﻨﺐ ﻋﺪم وﺟﻮد أﻳﺔ ﻋﻮاﺋﻖ أﻣﺎم اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﻣﺜﻞ اﻟﺴﺘﺎﺋﺮ أو اﻷﺛﺎث أو اﻟﻤﻼﺑﺲ ﻓﻰ ﻣﻜﺎن اﻟﺘﺮآﻴﺐ‬
‫أﻣﺎم ﺣﺮآﺔ اﻟﻬﻮاء اﻟﻤﻜﻴﻒ اﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة أو‬
‫ﺣﺮآﺔ اﻟﻬﻮاء اﻟﺮاﺟﻊ ﻟﻠﻮﺣﺪة ﻟﻠﻤﺤﺎﻓﻈﺔ ﻋﻠﻰ آﻔﺎءة‬
‫اﻟﺘﺒﺮﻳﺪ وآﻤﻴﺔ اﻟﻬﻮاء اﻟﻼزﻣﺔ ﻟﻬﺎ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺘﻌﺮض ﻷﺑﺨﺮة‬


‫زﻳﺖ ﺑﺎﻟﻘﺮب ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﻘﺮﻳﺐ ﻣﻦ ﺗﺄﺛﻴﺮ‬


‫اﻟﻤﻮﺟﺎت اﻟﻜﻬﺮوﻣﻐﻨﺎﻃﻴﺴﻴﺔ اﻟﺼﺎدرة ﻣﻦ أﺟﻬﺰة‬
‫آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﻘﺮﻳﺐ ﻣﻦ اﻟﻐﺎزات اﻟﻘﺎﺑﻠﺔ ﻟﻼﺷﺘﻌﺎل أو أﻳﺔ ﻏﺎزات آﺒﺮﻳﺘﻴﺔ‪.‬‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﺑﺤﻴﺚ ﻳﺘﺤﻤﻞ اﻟﺤﺎﺋﻂ وزن اﻟﻮﺣﺪة وﺑﺎﻟﺘﺎﻟﻰ ﺗﺠﻨﺐ ﺗﺮآﻴﺐ اﻟﻮﺣﺪة ﻋﻠﻰ اﻟﺤﻮاﺋﻂ اﻟﺨﺸﺒﻴﺔ‬
‫أو اﻟﺠﺒﺴﻴﺔ أواﻟﺸﺒﻚ اﻟﻤﻤﺪد واﻟﻘﻮاﻃﻊ اﻟﻐﻴﺮ ﻣﺜﺒﺘﺔ‪.‬‬

‫‪٧‬‬
‫‪ -٩‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ ١-٩‬اﻋﺘﺒﺎرات اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ اﻟﻄﻮل‬


‫اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﻟﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻴﻦ‬
‫اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﻟﺘﻔﺎدى ﺗﻘﻠﻴﻞ‬
‫آﻔﺎءة ﺗﺒﺮﻳﺪ وﺗﺪﻓﺌﺔ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ اﻹرﺗﻔﺎع‬


‫اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‬
‫وذﻟﻚ ﻟﺘﻔﺎدى ﺗﻘﻠﻴﻞ آﻔﺎءة ﺗﺒﺮﻳﺪ وﺗﺪﻓﺌﺔ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﻳﺠﺐ ﺗﺠﻨﺐ ﻋﻤﻞ اﻧﺤﻨﺎءات آﺜﻴﺮة ﻓﻰ وﺻﻼت ﻣﻮاﺳﻴﺮ‬


‫اﻟﻔﺮﻳﻮن ﻋﻨﺪ ﺗﻮﺻﻴﻠﻬﺎ ﺑﺎﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‬
‫وذﻟﻚ ﻟﺘﻔﺎدى ﺗﻘﻠﻴﻞ آﻔﺎءة ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﺗﻮﺟﺪ ﺑﻪ ﻋﻮاﺋﻖ‬


‫ﻟﻠﻬﻮاء اﻟﺪاﺧﻞ واﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫ﺗﺠﻨﺐ ﺗﺮآﻴﺐ وﺣﺪات ﺧﺎرﺟﻴﺔ ﺑﺠﻮار ﺑﻌﻀﻬﺎ ﺑﺤﻴﺚ‬


‫ﻳﻜﻮن اﻟﻬﻮاء اﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة اﻷوﻟﻰ ﻣﻮاﺟﻬ ًﺎ‬
‫ﻟﻠﻮﺣﺪة اﻟﺜﺎﻧﻴﺔ وهﻜﺬا‪.‬‬

‫‪٨‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﺗﺎﺑﻊ ‪ -‬اﻋﺘﺒﺎرات اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺘﺤﻤﻞ وزن اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺘﺤﻤﻞ ﺑﻌﻴﺪًا ﺑﻘﺪر اﻹﻣﻜﺎن ﻋﻦ أﺷﻌﺔ اﻟﺸﻤﺲ أو أﻳﺔ ﻣﻨﺎﻃﻖ ﺳﺎﺧﻨﺔ‪.‬‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﻜﻮن ﻧﻈﻴﻔﺎ ﺧﺎﻟﻴﺎ ﻣﻦ اﻷﺗﺮﺑﺔ أو أﻳﺔ ﻣﻮاد ﻳﻤﻜﻦ أن ﺗﺴﺒﺐ اﻧﺴﺪاد‬
‫اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻤﻜﺜﻒ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﻜﻮن ﻣﻌﺮﺿ ًﺎ ﻷﺑﺨﺮة اﻟﺰﻳﺖ‪.‬‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﻜﻮن ﻣﻌﺮﺿ ًﺎ ﻟﻐﺎزات آﺒﺮﻳﺘﻴﺔ‬

‫ﺗﺠﻨﺐ إﺧﺘﻴﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺆدي إﻟﻰ إزﻋﺎج اﻟﺠﻴﺮان ﺑﺴﺒﺐ ﺻﻮت اﻟﺘﺸﻐﻴﻞ واﻟﻬﻮاء اﻟﺨﺎرج ﻣﻦ‬
‫اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫ﻓﻲ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ﻋﻠﻰ اﻟﺴﻄﺢ أو ﻓﻲ اﻷﻣﺎآﻦ اﻷﺧﺮى اﻟﻤﻌﺮﺿﺔ ﻟﺮﻳﺎح ﺷﺪﻳﺪة ‪:‬‬

‫ﻓﻲ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻋﻠﻰ اﻟﺴﻄﺢ أو ﻓﻲ اﻷﻣﺎآﻦ اﻟﺘﻲ ﻻﺗﺤﻴﻂ ﺑﻬﺎ اﻳﺔ ﻣﺒﺎﻧﻲ ﻳﺠﺐ ﻋﺪم ﺗﻌﺮض اﻟﻬﻮاء اﻟﺨﺎرج ﻣﻦ‬
‫اﻟﻮﺣﺪة ﻟﻠﺮﻳﺎح اﻟﺸﺪﻳﺪة وذﻟﻚ ﻟﺘﺠﻨﺐ اﻟﺘﺄﺛﻴﺮ ﻋﻠﻰ ﻣﻌﺪل ﺗﺪﻓﻖ هﻮاء اﻟﻮﺣﺪة وﺑﺎﻟﺘﺎﻟﻲ ﺗﺠﻨﺐ اﻟﺘﺄﺛﻴﺮ ﻋﻠﻰ آﻔﺎءة اﻟﺘﺒﺮﻳﺪ واﻟﺘﺪﻓﺌﺔ ‪.‬‬

‫ﻋﻨﺪﻣﺎ ﺗﻜﻮن هﻨﺎك ﺣﻮاﺋﻂ ﻗﺮﻳﺒﺔ ﻣﻦ اﻟﻮﺣﺪة ﻓﺈﻧﻪ ﻳﺘﻢ ﺗﺮآﻴﺐ ﻋﻨﺪﻣﺎ ﻳﻜﻮن اﺗﺠﺎﻩ اﻟﻬﻮاء اﻟﺨﺎرﺟﻲ ﻣﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﺤﻴﺚ ﻳﻜﻮن إﺗﺠﺎﻩ اﻟﻬﻮاء اﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة ﻣﺘﺄﺛﺮًا ﺑﺮﻳﺎح ﺷﺪﻳﺪة ﻓﺈﻧﻪ ﻳﺠﺐ ﺗﻐﻴﻴﺮ ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﺑﺤﻴﺚ ﻳﻜﻮن‬
‫ﻣﻮاﺟﻬﺎ ﻟﻠﺤﺎﺋﻂ ﻣﻊ اﻟﻤﺤﺎﻓﻈﺔ ﻋﻠﻰ ﻣﺴﺎﻓﺔ ﻻﺗﻘﻞ ﻋﻦ ‪ ٥٠٠‬ﻣﻢ اﺗﺠﺎﻩ اﻟﻬﻮاء اﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة ﺑﺰاوﻳﺔ ﻣﺴﺘﻘﻴﻤﺔ ﺑﻌﻴﺪًا ﻋﻦ‬
‫اﺗﺠﺎﻩ اﻟﺮﻳﺎح‬ ‫ﻣﻦ اﻟﺤﺎﺋﻂ‬

‫‪٩‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ ٢-٩‬أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ وﺣﺪة ﺧﺎرﺟﻴﺔ واﺣﺪة‬
‫أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ وﺣﺪة ﺧﺎرﺟﻴﺔ واﺣﺪة‬
‫أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ أآﺜﺮ ﻣﻦ وﺣﺪة ﺧﺎرﺟﻴﺔ‬

‫إﺧﺘﺎر ﻣﻜﺎن اﻟﺘﺮآﻴﺐ اﻟﺬي ﻳﺴﻤﺢ ﺑﻮﺟﻮد أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺘﻢ ﺗﺮآﻴﺒﻬﺎ ﺣﻮل اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻟﻀﻤﺎن ﺣﺮﻳﺔ ﺣﺮآﺔ‬
‫اﻟﻬﻮاء اﻟﺪاﺧﻞ واﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ وأﻳﻀ ًﺎ ﻟﺴﻬﻮﻟﺔ ﻋﻤﻠﻴﺎت اﻟﺨﺪﻣﺔ واﻟﺼﻴﺎﻧﺔ ‪.‬‬
‫• ﻳﺠﺐ أن ﺗﻜﻮن واﺟﻬﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﻌﻴﺪة ﻋﻦ أﻳﺔ ﻋﻮاﺋﻖ ﺑﻤﺴﺎﻓﺔ ﺗﺴﻤﺢ ﺑﺤﺮﻳﺔ ﺣﺮآﺔ ﺧﺮوج اﻟﻬﻮاء ﻣﻦ‬
‫اﻟﻮﺣﺪة واﻟﻤﺤﺎﻓﻈﺔ ﻋﻠﻰ آﻔﺎءﺗﻬﺎ‪.‬‬

‫• ﻳﺠﺐ أن ﻳﻜﻮن ﻇﻬﺮ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﻌﻴﺪًا ﻋﻦ أﻳﺔ ﻋﻮاﺋﻖ ﺑﻤﺴﺎﻓﺔ ﺗﺴﻤﺢ ﺑﺤﺮﻳﺔ ﺣﺮآﺔ دﺧﻮل اﻟﻬﻮاء إﻟﻰ‬
‫اﻟﻮﺣﺪة واﻟﻤﺤﺎﻓﻈﺔ ﻋﻠﻰ آﻔﺎءﺗﻬﺎ‪.‬‬

‫ﻓﻲ ﺣﺎﻟﺔ اﻟﺘﺮآﻴﺐ اﻟﺤﺎﺋﻄﻲ ﺗﻜﻮن هﺬﻩ اﻟﻤﺴﺎﻓﺔ ‪ ١٦‬ﺳﻢ ﻣﻮﺟــﻮدة ﻓﻲ ﺗﺼﻤﻴﻢ اﻟﺘﺤﻤﻴــﻠﺔ اﻟﺤﺎﺋﻄﻴــﺔ‬
‫ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ‪.‬‬
‫• ﻳﺠﺐ أن ﻳﻜﻮن اﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﻌﻴﺪًا ﻋﻦ أﻳﺔ ﻋﻮاﺋﻖ ﺑﻤﺴﺎﻓﺔ ‪ ٤٠‬ﺳﻢ أو أآﺜﺮ ﺗﺴﻤﺢ‬
‫ﺑﺴﻬﻮﻟﺔ ﺗﻮﺻﻴﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن وﺳﻬﻮﻟﺔ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪.‬‬

‫• ﻳﺠﺐ أن ﻳﻜﻮن اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﻌﻴﺪًا ﻋﻦ أﻳﺔ ﻋﻮاﺋﻖ ﺑﻤﺴﺎﻓﺔ ‪ ٢٥‬ﺳﻢ أو أآﺜﺮ ﺗﺴﻤﺢ ﺑﺤﺮﻳﺔ‬
‫ﺣﺮآﺔ دﺧﻮل اﻟﻬﻮاء إﻟﻰ اﻟﻮﺣﺪة واﻟﻤﺤﺎﻓﻈﺔ ﻋﻠﻰ آﻔﺎءﺗﻬﺎ‪.‬‬

‫• ﻳﺠﺐ أن ﻳﻜﻮن أﻋﻠﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﻌﻴﺪًا ﻋﻦ أﻳﺔ ﻋﻮاﺋﻖ ﺑﻤﺴﺎﻓﺔ ‪ ٤٠‬ﺳﻢ أو اآﺜﺮ ‪ ،‬ﺗﺴﻤﺢ ﺑﺴﻬﻮﻟﺔ‬
‫ﻋﻤﻠﻴﺎت اﻟﺨﺪﻣﺔ واﻟﺼﻴﺎﻧﺔ ﻟﻠﻤﻜﻮﻧﺎت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ واﻟﻤﻮﺗﻮر واﻟﻤﺮوﺣﺔ‪.‬‬

‫‪١٠‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ وﺣﺪة ﺧﺎرﺟﻴﺔ واﺣﺪة‬
‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻣﺎم واﺟﻬﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺨﺮج اﻟﻬﻮاء (‬

‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬

‫‪ ٥٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫ﻋﺎﺋﻖ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ ﺧﻠﻒ أو أﻋﻠﻰ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻣﺎم واﺟﻬﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺨﺮج اﻟﻬﻮاء (‬


‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬
‫ﻣﻼﺣﻈﺔ ‪ :‬إرﺗﻔﺎع اﻟﻌﺎﺋﻖ ﻳﺠﺐ أن ﻳﻜﻮن أﻗﻞ ﻣﻦ إرﺗﻔﺎع اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻋﺎﺋﻖ‬
‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬

‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬

‫‪١٠٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬

‫ﻋﺎﺋﻖ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻋﻠﻰ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻣﺎم واﺟﻬﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺨﺮج اﻟﻬﻮاء (‬


‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻋﻠﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﻋﺎﺋﻖ‬
‫‪١٠٠‬ﺳﻢ‬
‫‪١٠٠‬ﺳﻢ‬ ‫أو أآﺜﺮ‬
‫أو أآﺜﺮ‬

‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ ﺧﻠﻒ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪١١‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ وﺣﺪة ﺧﺎرﺟﻴﺔ واﺣﺪة‬
‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬

‫ﻋﺎﺋﻖ‬
‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬

‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻣﺎم أو أﻋﻠﻰ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬


‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻋﻠﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻋﺎﺋﻖ‬
‫‪٤٠‬ﺳﻢ‬ ‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬

‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻣﺎم أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬


‫ﺗﻮﺟﺪ ﻋﻮاﺋﻖ ﻋﻠﻰ اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ وﻋﻠﻰ اﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ‬

‫ﻋﺎﺋﻖ‬
‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬
‫ﻋﺎﺋﻖ‬

‫‪٢٥‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻣﺎم أو أﻋﻠﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪١٢‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ أآﺜﺮ ﻣﻦ وﺣﺪة ﺧﺎرﺟﻴﺔ‬
‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻣﺎم واﺟﻬﺎت اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺨﺮج اﻟﻬﻮاء (‬

‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬


‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬
‫‪١٠٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫ﻋﺎﺋﻖ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ ﺧﻠﻒ أو أﻋﻠﻰ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ أﻣﺎم واﺟﻬﺎت اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺨﺮج اﻟﻬﻮاء (‬


‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬
‫ﻣﻼﺣﻈﺔ ‪ :‬إرﺗﻔﺎع اﻟﻌﺎﺋﻖ ﻳﺠﺐ أن ﻳﻜﻮن أﻗﻞ ﻣﻦ إرﺗﻔﺎع اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ‬

‫ﻋﺎﺋﻖ‬
‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬

‫‪١٠٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫ﻋﺎﺋﻖ‬
‫‪٤٠‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬
‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻋﻠﻰ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬


‫ﻋﺎﺋﻖ‬
‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬

‫‪٤٠‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬
‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻣﺎم أو أﻋﻠﻰ أو ﻳﻤﻴﻦ أو ﻳﺴﺎر اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ‬

‫‪١٣‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﺧﺘﻴﺎر ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫أﻗﻞ ﻣﺴﺎﻓﺎت ﻳﺠﺐ ﻣﺮاﻋﺎﺗﻬﺎ ﺣﻮل اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﺣﺎﻟﺔ ﺗﺮآﻴﺐ أآﺜﺮ ﻣﻦ وﺣﺪة ﺧﺎرﺟﻴﺔ‬

‫ﻳﻮﺟﺪ ﻋﺎﺋﻖ ﺧﻠﻒ اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ ) أﻣﺎم ﻣﺪﺧﻞ اﻟﻬﻮاء (‬


‫ﺗﻮﺟﺪ ﻋﻮاﺋﻖ ﻋﻠﻰ اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ وﻋﻠﻰ اﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ‬
‫ﻋﺎﺋﻖ‬ ‫ﻋﺎﺋﻖ‬
‫ﻋﺎﺋﻖ‬
‫‪١٦‬ﺳﻢ‬
‫أو أآﺜﺮ‬
‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬ ‫اﻟﻮﺣﺪة‬
‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﺨﺎرﺟﻴﺔ‬

‫‪٢٥‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬


‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻣﺎم أو أﻋﻠﻰ اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ‬

‫ﻋﺎﺋﻖ‬ ‫ﻋﺎﺋﻖ‬

‫‪١٠٠‬ﺳﻢ‬ ‫‪٤٠‬ﺳﻢ‬ ‫‪١٥٠‬ﺳﻢ‬ ‫‪٢٠٠‬ﺳﻢ‬ ‫‪١٦‬ﺳﻢ‬


‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬ ‫أو أآﺜﺮ‬

‫ﻻﺗﻮﺟﺪ ﻋﻮاﺋﻖ أﻣﺎم أو أﻋﻠﻰ اﻟﻮﺣﺪات اﻟﺨﺎرﺟﻴﺔ‬

‫‪١٤‬‬
‫‪ -١٠‬ﻗﺎﺋﻤﺔ ﻓﺤﻮﺻﺎت اﺧﺘﻴﺎر أﻣﺎآﻦ اﻟﺘﺮآﻴﺐ‬

‫أو ًﻻ‪ :‬اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪ .١‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻳﺴﻤﺢ ﺑﺤﺮﻳﺔ ﺣﺮآﺔ اﻟﻬﻮاء اﻟﺪاﺧﻞ واﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة وﻳﺴﻤﺢ ﻳﺴﻬﻮﻟﺔ ﻋﻤﻠﻴﺎت‬
‫اﻟﺨﺪﻣﺔ واﻟﺼﻴﺎﻧﺔ‪.‬‬
‫‪ .٢‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻳﺴﻤﺢ ﺑﺄن ﺗﻜﻮن ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ اﻟﻼزﻣﺔ ﻟﺨﺮوج وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن واﻟﻜﺎﺑﻼت‬
‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ ﺗﻢ اﺧﺘﻴﺎر ﻣﻜﺎﻧﻬﺎ ﺑﺤﻴﺚ ﻻ ﺗﻜﻮن ﻓﻰ ﻋﻤﻮد أو آﻤﺮ ﺧﺮﺳﺎﻧﻰ وأﻳﻀ ًﺎ ﻻ‬
‫ﺗﻘﻄﻊ ﺧﻄﻮط ﺗﻐﺬﻳﺔ آﻬﺮﺑﺎﺋﻴﺔ أو ﻣﻮاﺳﻴﺮ داﺧﻞ اﻟﺤﺎﺋﻂ‬
‫‪ .٣‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻗﺮﻳﺐ ﻣﻦ ﻣﻜﺎن ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ .٤‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻳﺴﻤﺢ أن ﺗﻐﻄﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ أآﺒﺮ ﺟﺰء ﻣﻦ اﻟﻐﺮﻓﺔ ﺑﺎﻟﻬﻮاء اﻟﻤﻜﻴﻒ اﻟﺨﺎرج‬
‫ﻣﻦ اﻟﻮﺣﺪة‬
‫‪ .٥‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﺑﻌﻴﺪ ﻋﻦ أﺷﻌﺔ اﻟﺸﻤﺲ‬

‫‪ .٦‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﺑﻌﻴﺪ ﻋﻦ أﻳﺔ ﻣﺼﺎدر ﺣﺮارﻳﺔ‬

‫ﺛﺎﻧﻴ ًﺎ‪ :‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪ .١‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻗﺮﻳﺐ ﻣﻦ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻲ‬


‫‪ .٢‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻳﺴﻤﺢ ﺑﺤﺮﻳﺔ ﺣﺮآﺔ اﻟﻬﻮاء اﻟﺪاﺧﻞ واﻟﺨﺎرج ﻣﻦ اﻟﻮﺣﺪة‬
‫وﻳﺴﻤﺢ ﺑﺴﻬﻮﻟﺔ ﻋﻤﻠﻴﺎت اﻟﺨﺪﻣﺔ واﻟﺼﻴﺎﻧﺔ‬
‫‪ .٣‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻳﺴﻤﺢ أن ﻳﻜﻮن ﻣﻜﺎن ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ ﻣﻼﺋﻤ ًﺎ ﻟﻠﺘﺮآﻴﺐ‬

‫‪ .٤‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻗﺮﻳﺐ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪ .٥‬ﻳﺘﺤﻤﻞ ﻣﻜﺎن اﻟﺘﺮآﻴﺐ وزن اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪ .٦‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﺑﻌﻴﺪ ﻋﻦ أﺷﻌﺔ اﻟﺸﻤﺲ أو أﻳﺔ ﻣﻨﺎﻃﻖ ﺳﺎﺧﻨﺔ‬

‫‪ .٧‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻧﻈﻴﻒ ﺧﺎﻟﻲ ﻣﻦ اﻷﺗﺮﺑﺔ‬

‫‪ .٨‬ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻻﻳﺆدي إى إزﻋﺎج اﻟﺠﻴﺮان ﺑﺴﺒﺐ ﺻﻮت اﻟﺘﺸﻐﻴﻞ واﻟﻬﻮاء اﻟﺨﺎرج‬

‫ﺛﺎﻟﺜ ًﺎ‪ :‬وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‬

‫‪ .١‬ﺗﻢ ﺗﺠﻨﺐ اﺧﺘﻴﺎر اﻟﻄﻮل اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﻟﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫‪ .٢‬ﺗﻢ ﺗﺠﻨﺐ اﻻرﺗﻔﺎع اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‬


‫)وﺧﺼﻮﺻ ًﺎ إذا آﺎﻧﺖ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ أﻋﻠﻰ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ(‬
‫‪ .٣‬ﺗﻢ ﺗﺠﻨﺐ ﻋﻤﻞ اﻹﻧﺤﻨﺎءات اﻟﻜﺜﻴﺮة ﻓﻲ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫ﻋﻨﺪ ﺗﻮﺻﻴﻠﻬﺎ ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‬

‫‪١٥‬‬
‫‪ - ١١‬ﻣﻠﺤﻘﺎت اﻟﺘﺮآﻴﺒﺎت‬
‫‪ ١-١١‬اﻟﻤﻠﺤﻘﺎت اﻟﻘﻴﺎﺳﻴﺔ ﻟﻠﺘﺮآﻴﺐ واﻟﺘﻰ ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ ﻣﻊ أﺟﻬﺰة ﺗﻜﻴﻴﻒ اﻟﻬﻮاء اﻟﻤﻨﻔﺼﻠﺔ ‪:‬‬
‫اﻻﺳﺘﺨﺪام‬ ‫اﻟﻜﻤﻴﺔ‬ ‫اﻟﺸﻜﻞ‬ ‫اﻟﺘﻮﺻﻴﻒ‬

‫ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬ ‫‪١‬‬ ‫وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬

‫ﺗﺮآﻴﺐ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬


‫ﻋﻠﻰ اﻟﺤﺎﺋﻂ‬
‫‪١‬‬ ‫اﻟﺤﺎﻣﻞ اﻟﺒﻼﺳﺘﻴﻚ ﻟﻮﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬
‫ﺗﺜﺒﻴﺖ اﻟﺤﺎﻣﻞ اﻟﺒﻼﺳﺘﻴﻚ ﻟﻮﺣﺪة اﻟﺘﺤﻜﻢ‬
‫ﻣﺴﻤﺎر ﺗﺜﺒﻴﺖ ﻗﻄﺮ ‪١٠ x ٢٫٩‬ﻣﻢ‬
‫اﻟﻼﺳﻠﻜﻴﺔ ﻋﻠﻰ اﻟﺤﺎﺋﻂ‬
‫ﺗﺸﻐﻴﻞ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬ ‫‪٢‬‬ ‫ﺑﻄﺎرﻳﺔ ‪ ١٫٥‬ﻓﻮﻟﺖ ﻣﻘﺎس ‪AAA‬‬
‫ﺗﻮﺿﻴﺢ ﺗﻌﻠﻴﻤﺎت ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬ ‫‪١‬‬ ‫آﺘﺎﻟﻮج ﺗﻌﻠﻴﻤﺎت اﻟﺘﺸﻐﻴﻞ‬
‫ﺗﻮﺿﻴﺢ ﺗﻌﻠﻴﻤﺎت ﺗﺮآﻴﺐ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬ ‫‪١‬‬ ‫آﺘﺎﻟﻮج اﻟﺘﺮآﻴﺒﺎت‬

‫ﺗﺜﺒﻴﺖ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻓﻰ اﻟﺤﺎﺋﻂ‬ ‫‪١‬‬ ‫ﺣﺎﻣﻞ ﺗﺜﺒﻴﺖ‬


‫ﺗﺜﺒﻴﺖ ﺣﺎﻣﻞ اﻟﺘﺜﺒﻴﺖ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وأﻳﻀ ًﺎ‬
‫ﺑﺎﻟﺤﺎﺋﻂ‬
‫‪٤‬‬ ‫ﻣﺴﻤﺎر ‪ ٢٥ x ٤‬ﻣﻢ‬
‫ﺗﺜﺒﻴﺖ ﺣﺎﻣﻞ اﻟﺘﺜﺒﻴﺖ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وأﻳﻀ ًﺎ‬
‫ﺑﺎﻟﺤﺎﺋﻂ‬
‫‪٤‬‬ ‫وردة ﻋﺎدﻳﺔ ‪ ٤‬ﻣﻢ‬
‫اﻟﺘﺤﻜﻢ اﻟﻜﻬﺮﺑﺎﺋﻰ ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫اﻟﻮﺻﻠﺔ اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻟﻠﺘﺤﻜﻢ ﺑﻴﻦ‬
‫واﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪١‬‬ ‫اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ واﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﺣﻤﺎﻳﺔ اﻷﺳﻼك اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫‪٢‬‬ ‫ﺣﻠﻘﺔ ﻣﻄﺎط‬

‫ﺣﻤﺎﻳﺔ اﻟﻤﻮاﺳﻴﺮ‬ ‫‪١‬‬ ‫ﺷﺮﻳﻂ ﺑﻼﺳﺘﻴﻚ‬


‫ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻣﻦ‬
‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪١‬‬ ‫ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬

‫ﺗﻐﻄﻴﺔ اﻟﺨﻠﻮص اﻟﻤﻮﺟﻮد ﺑﻴﻦ ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ‬ ‫‪١‬‬ ‫ﺟﻠﺒﺔ ﺑﻼﺳﺘﻴﻚ ﻟﻔﺘﺤﺔ اﻟﺤﺎﺋﻂ‬
‫وﺣﺰﻣﺔ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن واﻟﻜﺎﺑﻼت‬
‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬ ‫‪١‬‬ ‫ﻣﻌﺠﻮن ﻣﺎﻧﻊ اﻟﺘﺴﺮب‬
‫رﺑﺎط وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻣﻊ اﻟﻜﺎﺑﻼت‬
‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ‪.‬‬
‫‪١‬‬ ‫ﺷﺮﻳﻂ ﻻﺻﻖ ﻟﺘﺸﻄﻴﺐ اﻟﺘﺮآﻴﺒﺎت‬

‫‪٢‬‬ ‫ﺟﻠﺐ ﻋﺎزﻟﺔ ﻟﻠﺤﺮارة واﻟﺼﻮت‬


‫ﺗﺴﺘﺨﺪم ﻣﻊ وﺻﻠﺔ اﻟﺼﺮف‬ ‫‪١‬‬ ‫وردة ﻣﺎﻧﻌﺔ ﻟﻠﺘﺴﺮب‬
‫ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻣﻦ‬
‫‪١‬‬ ‫وﺻﻠﺔ اﻟﺼﺮف‬
‫اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ إﻟﻰ اﻟﺨﺎرج‬

‫‪١٦‬‬
‫ﺗﺎﺑﻊ‪ -‬ﻣﻠﺤﻘﺎت اﻟﺘﺮآﻴﺒﺎت‬

‫ﺗﺎﺑﻊ ‪ -‬اﻟﻤﻠﺤﻘﺎت اﻻﺧﺘﻴﺎرﻳﺔ اﻟﺘﻲ ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ ﺣﺴﺐ اﻟﻄﻠﺐ ﻷﺟﻬﺰة ﺗﻜﻴﻴﻒ اﻟﻬﻮاء اﻟﻤﻨﻔﺼﻠﺔ ‪:‬‬

‫اﻻﺳﺘﺨﺪام‬ ‫اﻟﻜﻤﻴﺔ‬ ‫اﻟﺸﻜﻞ‬ ‫اﻟﺘﻮﺻﻴﻒ‬


‫اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻋﻠﻰ اﻟﺤﺎﺋﻂ‬ ‫‪١‬‬ ‫ﻟﺠﻬﺎز ﺗﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪38QFJ36‬‬
‫) ﺧﺎﺻﺔ ﻓﻘﻂ ﺑﺎﻟﺴﻮق اﻟﻤﺤﻠﻰ (‬
‫اﻟﺘﺤﻤﻴﻠﺔ اﻷرﺿﻴﺔ ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﻟﺠﻬﺎز ﺗﻜﻴﻴﻒ ﻣﻮدﻳﻼت‬
‫ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻋﻠﻰ اﻷرض‬ ‫‪38QFJ36‬‬
‫‪١‬‬
‫أو اﻟﺴﻄﺢ‬ ‫‪38QFJ48‬‬
‫‪38KFJT60‬‬
‫) ﺧﺎﺻﺔ ﻓﻘﻂ ﺑﺎﻟﺴﻮق اﻟﻤﺤﻠﻰ (‬
‫ﺗﻮﺻﻴﻞ اﻟﻔﺮﻳﻮن ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن اﻟﻤﻌﺰوﻟﺔ‬
‫واﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ووﺻﻼت ﻣﻮاﺳﻴﺮ‬ ‫‪١‬‬ ‫واﻟﻤﺰودة ﺑﺎﻟﻜﺎﺑﻠﻨﺞ اﻟﻔﻠﻴﺮ ﻃﻮل ‪٤‬‬
‫اﻟﻔﺮﻳﻮن‬ ‫) ﺧﺎﺻﺔ ﻓﻘﻂ ﺑﺎﻟﺴﻮق اﻟﻤﺤﻠﻰ (‬

‫‪٢-١١‬اﻟﻤﻠﺤﻘﺎت اﻷﺧﺮى اﻟﺘﻰ ﻳﺠﺐ اﺳﺘﺨﺪاﻣﻬﺎ ﻓﻰ اﻟﺘﺮآﻴﺒﺎت وﻻ ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ ‪:‬‬

‫اﻻﺳﺘﺨﺪام‬ ‫اﻟﺘﻮﺻﻴﻒ‬

‫اﻟﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ واﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ وﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ‪.‬‬ ‫‪ -‬آﺎﺑﻼت آﻬﺮﺑﺎﺋﻴﺔ‬

‫‪ -‬ﺷﺮﻳﻂ ﻻﺻﻖ ﻟﻌﺎزل‬


‫ﻟﺼﻖ ﻋﺎزل وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫اﻟﻤﻮاﺳﻴﺮ‬

‫‪ -‬ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬


‫ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ إﻟﻰ اﻟﺨﺎرج‪.‬‬
‫ﻗﻄﺮ ﺧﺎرﺟﻰ ‪ ٢٦‬ﻣﻢ‪.‬‬

‫ﺗﻮﺻﻴﻞ اﻟﻔﺮﻳﻮن ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ و اﻟﺨﺎرﺟﻴﺔ‬


‫ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬ ‫‪-‬‬
‫ووﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪.‬‬

‫ﻋﺰل وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻐﺎز واﻟﺴﺎﺋﻞ‪.‬‬ ‫ﻋﺎزل اﻟﻤﻮاﺳﻴﺮ‬ ‫‪-‬‬

‫ﺿﺒﻂ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن ﻟﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن اﻟﻄﻮﻳﻠﺔ‪.‬‬ ‫ﻓﺮﻳﻮن ‪٢٢‬‬ ‫‪-‬‬

‫ﺗﺜﺒﻴﺖ اﻟﺤﺰﻣﺔ اﻟﻤﻜﻮﻧﺔ ﻣﻦ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن واﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬


‫ﻣﺸﺎﺑﻚ ﺁو ﺣﻮاﻣﻞ ﺗﺜﺒﻴﺖ‬ ‫‪-‬‬
‫وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‪.‬‬

‫‪١٧‬‬
‫‪ -١٢‬ﺧﺮﻳﻄﺔ ﺗﺮﺗﻴﺐ أﻋﻤﺎل اﻟﺘﺮآﻴﺒﺎت‬

‫‪ (٩‬ﻁﺭﺩ ﺍﻟﺭﻁﻭﺒﺔ ﻭﺍﻟﻬﻭﺍﺀ ﻤﻥ ﺍﻟﺠﻬﺎﺯ‬ ‫‪ (٥‬ﺘﻭﺼﻴل ﻭﺼﻼﺕ ﻤﻭﺍﺴﻴﺭ ﺍﻟﻔﺭﻴﻭﻥ‬ ‫‪ (١‬ﺘﺭﻜﻴﺏ ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬

‫‪ (١٠‬ﺍﺨﺘﺒﺎﺭ ﺘﻨﻔﻴﺱ ﺍﻟﻔﺭﻴﻭﻥ‬ ‫‪ (٦‬ﺘﻭﺼﻴل ﺨﺭﻁﻭﻡ ﺘﺼﺭﻴﻑ ﻤﻴﺎﻩ‬ ‫‪ (٢‬ﻋﻤل ﻓﺘﺤﺔ ﺍﻟﺤﺎﺌﻁ‬
‫ﺍﻟﺘﻜﺜﻴﻑ‬

‫‪ (١١‬ﻓﺘﺢ ﺍﻟﻤﺤﺎﺒﺱ‬ ‫‪ (٧‬ﺍﻟﺘﻭﺼﻴﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ‬ ‫‪ (٣‬ﺘﺭﻜﻴﺏ ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬

‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬

‫‪ (١٢‬ﺍﻟﺘﺸﻁﻴﺏ ﺍﻟﻨﻬﺎﺌﻲ ﻷﻋﻤﺎل‬ ‫‪ (٨‬ﻋﺯل ﻭﺘﻐﻁﻴﺔ ﺍﻟﻤﻭﺍﺴﻴﺭ‬ ‫‪ (٤‬ﺘﺠﻬﻴﺯ ﺍﻟﻤﻭﺍﺴﻴﺭ ﺒﺎﻟﻔﻠﻴﺭ‬


‫ﺍﻟﺘﺭﻜﻴﺒﺎﺕ‬

‫‪ (١٣‬ﺍﺨﺘﺒﺎﺭ ﺘﺸﻐﻴل ﺠﻬﺎﺯ ﺍﻟﺘﻜﻴﻴﻑ‬

‫‪ (١٤‬ﺇﺭﺸﺎﺩ ﺍﻟﻌﻤﻴل ﺇﻟﻰ ﻁﺭﻴﻘﺔ‬


‫ﺘﺸﻐﻴل ﺠﻬﺎﺯ ﺍﻟﺘﻜﻴﻴﻑ‬

‫‪١٨‬‬
‫‪ .١٣‬ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪ ١-١٣‬ﺗﺠﻬﻴﺰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻗﺒﻞ اﻟﺘﺮآﻴﺐ‬
‫‪ -٢‬ﻓﻚ ﻏﻄﺎء ﻋﻠﺒﺔ اﻟﻜﻬﺮﺑﺎء‬ ‫‪ -١‬ﻓﻚ ﺟﺮﻳﻠﺔ راﺟﻊ اﻟﻬﻮاء‬
‫ﻓﻚ ﻣﺴﺎﻣﻴﺮ ﺗﺜﺒﻴﺖ ﻏﻄﺎء ﻋﻠﺒﺔ اﻟﻜﻬﺮﺑﺎء ﺛﻢ ﻓﻚ اﻟﻐﻄﺎء‬ ‫•‬ ‫اﻣﺴﻚ آﻼ ﻣﻦ ﺟﺎﻧﺒﻲ ﺟﺮﻳﻠﺔ راﺟﻊ اﻟﻬﻮاء ﺛﻢ اﺟﺬﺑﻬﺎ إﻟﻰ‬ ‫•‬
‫أﻋﻠﻰ ﺑﺤﻴﺚ ﺗﻜﻮن ﻣﺎﺋﻠﺔ ﺣﺘﻰ ﻳﺼﺒﺢ ﻣﺎﺳﻚ ﺟﺮﻳﻠﺔ راﺟﻊ‬
‫اﻟﻬﻮاء ﻣﺴﺘﻘﻴﻤﺎ ﺛﻢ ﻓﻚ ﻣﺴﺎﻣﻴﺮ ﺗﺜﺒﻴﺖ اﻟﻤﺎﺳﻚ ﺣﺘﻰ ﺗﺼﺒﺢ‬
‫ﻏﻁﺎﺀ ﻋﻠﺒﺔ‬
‫ﺟﺮﻳﻠﺔ راﺟﻊ اﻟﻬﻮاء ﺣﺮة وﻳﺘﻢ ﻓﻜﻬﺎ‪.‬‬
‫ﺍﻟﻜﻬﺭﺒﺎﺀ‬

‫ﺠﺭﻴﻠﺔ ﺭﺍﺠﻊ‬
‫ﺍﻟﻬﻭﺍﺀ‬

‫‪ ٢-١٣‬ﺧﻄﻮات اﻟﺘﺮآﻴﺐ ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫)‪ (١‬ﻳﺘﻢ ﺗﺜﺒﻴﺖ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻣﻊ اﻟﺤﺎﺋﻂ ﺑﺈﺳﺘﺨﺪام ﺣﺎﻣﻞ اﻟﺘﺜﺒﻴﺖ ﻓﻲ اﻟﺤﺎﺋﻂ ﺑﺈﺳﺘﺨﺪام ﻣﺴﺎﻣﻴﺮ ‪ ٢٥ x ٣٫٩‬ﻣﻢ أو ﺛﻢ ﻳﺘﻢ ﺗﺜﺒﻴﺖ اﻟﻮﺣﺪة‬
‫اﻟﺪاﺧﻠﻴﺔ ﻓﻰ أرﺿﻴﺔ اﻟﻤﻜﺎن اﻟﻤﺮاد ﺗﻜﻴﻴﻔﻪ ﺑﺈﺳﺘﺨﺪام ﺣﺎﻣﻞ اﻟﺘﺜﺒﻴﺖ ﻓﻲ اﻷرﺿﻴﺔ ﻣﻊ اﻟﻤﺴﺎﻣﻴﺮ واﻟﻮرد آﻤﺎ هﻮ ﻣﻮﺿﺢ ﺑﺎﻟﺮﺳﻢ‪.‬‬

‫ﺤﺎﻤل ﺍﻟﺘﺜﺒﻴﺕ‬ ‫ﻤﺴﺎﻤﻴﺭ‬


‫ﻓﻰ ﺍﻟﺤﺎﺌﻁ‬ ‫‪ ١٠ × ٣,٩‬ﻤﻡ‬

‫ﻭﺭﺩﺓ ﻋﺎﺩﻴﺔ‬
‫ﻤﺴﺎﻤﻴﺭ‬
‫‪ ٢٥ × ٣,٩‬ﻤﻡ‬ ‫ﺍﻟﻬﻭﺍﺀ ﺍﻟﻤﻜﻴﻑ‬

‫ﺤﺎﻤل ﺍﻟﺘﺜﺒﻴﺕ‬
‫ﻓﻲ ﺍﻷﺭﻀﻴﺔ‬
‫ﺍﻟﻬﻭﺍﺀ ﺍﻟﺭﺍﺠﻊ‬

‫)‪ (٢‬ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم اﻟﺘﻬﻮﻳﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬


‫ﺗﺄآﺪ ﻣﻦ ﻣﻜﺎن ﺧﺮوج ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ واﻗﻄﻊ‬ ‫‪١-٢‬‬
‫اﻟﻐﻄﺎء اﻟﺒﻼﺳﺘﻴﻚ اﻟﻤﻮﺟﻮد ﻓﻲ اﻟﺠﺎﻧﺐ اﻟﺬي ﺳﻴﺨﺮج ﻣﻨﻪ‬
‫ﺧﺮﻃﻮم ﺗﺼﺮﺳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‪.‬‬

‫ﺗﺄآﺪ ﻣﻦ ﻋﺪم وﺟﻮد أﻳﺔ اﺧﺘﻨﺎﻗﺎت ﻓﻲ ﺧﺮﻃﻮم اﻟﺘﻬﻮﻳﺔ أو‬ ‫‪٢-٢‬‬


‫ﺨﺭﻁﻭﻡ ﺘﺼﺭﻴﻑ‬ ‫ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‪.‬‬
‫ﻤﻴﺎﻩ ﺍﻟﺘﻜﺜﻴﻑ‬
‫أﻋﺰل آﻼ ﻣﻦ ﺧﺮﻃﻮم اﻟﺘﻬﻮﻳﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ‬ ‫‪٣-٢‬‬
‫اﻟﺘﻜﺜﻴﻒ‪.‬‬
‫ﻤﺠﻤﻭﻋﺔ ﺍﻟﻤﺭﻭﺤﺔ‬
‫ﺗﺄآﺪ ﻣﻦ وﺟﻮد ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻓﻲ اﻟﺠﺰء‬ ‫‪٤-٢‬‬
‫اﻷﺳﻔﻞ ﻣﻦ اﻟﺤﺰﻣﺔ اﻟﻤﻜﻮﻧﺔ ﻣﻦ ﺧﺮﻃﻮم اﻟﺘﻬﻮﻳﺔ وﺧﺮﻃﻮم‬
‫ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ‪.‬‬

‫‪١٩‬‬
‫‪ -١٤‬ﺗﺮآﻴﺐ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬
‫‪ ١-١٤‬ﺧﻄﻮات ﺗﺮآﻴﺐ اﻟﺒﻄﺎرﻳﺎت ﻓﻰ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬
‫)أ( ﻓﻚ ﻏﻄﺎء اﻟﺒﻄﺎرﻳﺎت اﻟﻤﻮﺟﻮد ﻓﻰ اﻟﺠﺰء اﻷﻣﺎﻣﻲ اﻟﺴﻔﻠﻰ ﻣﻦ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬
‫ﻋﻦ ﻃﺮﻳﻖ ﺗﺤﺮﻳﻜﻪ إﻟﻰ أﺳﻔﻞ ﻓﻰ اﺗﺠﺎﻩ اﻟﺴﻬﻢ‪.‬‬

‫)ب( رآﺐ اﻟﺒﻄﺎرﻳﺘﻴﻦ ﻣﻘﺎس ‪ ١٫٥ AAA‬ﻓﻮﻟﺖ واﻟﻤﻮﺟﻮدﺗﻴﻦ آﻤﻠﺤﻖ ﻣﻊ وﺣﺪة اﻟﺘﺤﻜﻢ‬
‫اﻟﻼﺳﻠﻜﻴﺔ‪ .‬ﺛﻢ ﻗﻢ ﺑﺘﺮآﻴﺐ ﻏﻄﺎء اﻟﺒﻄﺎرﻳﺎت ﻓﻰ ﻣﻜﺎﻧﻪ‪.‬‬

‫ﻣﻼﺣﻈﺔ‪:‬‬
‫أﺛﻨﺎء ﺗﺮآﻴﺐ اﻟﺒﻄﺎرﻳﺎت ﺗﺄآﺪ ﻣﻦ إﺷﺎرات اﻟﺒﻄﺎرﻳﺎت )‪+‬و‪ (-‬اﻟﻤﺒﻴﻨﺔ ﻓﻰ ﺧﺰاﻧﺔ اﻟﺒﻄﺎرﻳﺎت‪.‬‬

‫ﻣﻼﺣﻈــﺎت‬
‫‪ -١‬وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﻳﺘﻢ وﺿﻊ ﺑﻬﺎ ﺑﻄﺎرﻳﺘﻴﻦ ﻣﻌﺎ ﻣﻦ ﻣﻘﺎس ‪ ١٫٥ AAA‬ﻓﻮﻟﺖ‪.‬‬
‫‪ -٢‬ﻻﺗﺴﺘﺨﺪم اﻟﺒﻄﺎرﻳﺎت اﻟﻤﺴﺘﻌﻤﻠﺔ أو أﻧﻮاع أﺧﺮى ﻏﻴﺮ ﻣﻌﺮوﻓﺔ ﻻن ذﻟﻚ ﻗﺪ ﻳﺴﺒﺐ ﻋﻄﻞ ﻟﻮﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬
‫‪ -٣‬ﻓﻰ ﺣﺎﻟﺔ ﻋﺪم اﻻﺳﺘﺨﺪام ﻟﻤﺪة اﺳﺎﺑﻴﻊ ﻳﻔﻀﻞ ازاﻟﺔ اﻟﺒﻄﺎرﻳﺎت ﻣﻦ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﻟﻠﺤﻔﺎظ ﻋﻠﻴﻬﺎ‪.‬‬
‫‪ -٤‬اﻟﻌﻤﺮ اﻻﻓﺘﺮاﺿﻰ ﻟﻠﺒﻄﺎرﻳﺎت ﺣﻮاﻟﻰ ﺳﻨﺔ أو ﺳﻨﺔ وﻧﺼﻒ‪.‬‬
‫ﻋﻠﻰ‬ ‫‪ -٥‬إذا ﻟﻢ ﻳﻌﻤﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺑﻌﺪ ﺗﻐﻴﻴﺮ اﻟﺒﻄﺎرﻳﺎت ‪ ،‬وﻟﻢ ﻳﺼﺪر ﺻﻮت اﺳﺘﻘﺒﺎل اﻹﺷﺎرة ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وﻇﻬﻮر رﻣﺰ‬
‫ﺷﺎﺷﺔ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ‪ ،‬أﻋﺪ ﺗﻐﻴﺮ اﻟﺒﻄﺎرﻳﺎت ﻣﺮة أﺧﺮى واﺿﻐﻂ ﻣﻔﺘﺎح إﻋﺎدة اﻟﺘﺸﻐﻴﻞ‪.‬‬
‫‪ -٦‬ﻳﺠﺐ ﺗﻐﻴﻴﺮ اﻟﺒﻄﺎرﻳﺎت ﺑﻌﺪ إﻳﻘﺎف اﻟﺠﻬﺎز‪.‬‬
‫‪ ٢-١٤‬ﻋﻨﺪ ﺗﻮﺟﻴﻪ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ إﻟﻰ ﻣﺴﺘﻘﺒﻞ اﻻﺷﺎرات اﻟﻼﺳﻠﻜﻴﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻳﺮاﻋﻰ اﻋﺘﺒﺎر اﻟﻨﻘﺎط اﻟﺘﺎﻟﻴﺔ ‪:‬‬
‫ﻳﺠﺐ ﺗﻮﺟﻴﻪ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﻧﺎﺣﻴﺔ ﻣﺴﺘﻘﺒﻞ اﻹﺷﺎرات اﻟﻼﺳﻠﻜﻴﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﻋﻨﺪ اﻟﻀﻐﻂ ﻋﻠﻰ ﻣﻔﺎﺗﻴﺢ ﺗﺸﻐﻴﻞ‬ ‫‪-١‬‬
‫وﺣﺪة اﻟﺘﺤﻜﻢ ﻋﻨﺪﺋﺬ ﻳﺘﻢ ﺳﻤﺎع ﺻﻮت ﺻﻔﺎرة ﺗﺪل ﻋﻠﻰ اﺳﺘﻘﺒﺎل اﻻﺷﺎرات اﻟﻼﺳﻠﻜﻴﺔ ﻣﻦ وﺣﺪة اﻟﺘﺤﻜﻢ ﻋﻦ ﻃﺮﻳﻖ ﻣﺴﺘﻘﺒﻞ اﻻﺷﺎرات‬
‫اﻟﻼﺳﻠﻜﻴﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫ﺗﺠﻨﺐ ﺗﻌﺮض ﻣﺴﺘﻘﺒﻞ اﻹﺷﺎرات اﻟﻼﺳﻠﻜﻴﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻷﺷﻌﺔ اﻟﺸﻤﺲ اﻟﻤﺒﺎﺷﺮة اﻟﺘﻰ ﺗﻌﻮق ﻣﻦ وﺻﻮل اﻹﺷﺎرات اﻟﻼﺳﻠﻜﻴﺔ‬ ‫‪-٢‬‬
‫ﻣﻦ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ إﻟﻰ ﻣﺴﺘﻘﺒﻞ اﻹﺷﺎرات‪.‬‬
‫ﺗﺠﻨﺐ وﺟﻮد أﻳﺔ ﻋﻮاﺋﻖ ﻣﺜﻞ اﻟﺴﺘﺎﺋﺮ ﺑﻴﻦ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ وﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬ ‫‪-٣‬‬
‫أﻗﺼﻰ ﻣﺪى ﻟﺘﺸﻐﻴﻞ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﺣﻮاﻟﻰ ‪ ٨‬ﻣﺘﺮ‪.‬‬ ‫‪-٤‬‬
‫ﺣﺎﻓﻆ ﻋﻠﻰ وﺟﻮد وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﺑﻌﻴﺪُا ﻋﻦ اﻟﻤﺎء ‪ ،‬ﺗﺠﻨﺐ ﺳﻘﻮط وﺣﺪة اﻟﺘﺤﻜﻢ ﻋﻠﻰ اﻷرض‪.‬‬ ‫‪-٥‬‬
‫ﻻ ﺗﺴﺘﺨﺪم أداة ﺣﺎدة ﻓﻰ اﻟﻀﻐﻂ ﻋﻠﻰ ﻣﻔﺎﺗﻴﺢ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬ ‫‪-٦‬‬
‫ﺗﺠﻨﺐ ﺳﻘﻮط أى ﺳﺎﺋﻞ ﻋﻠﻰ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬ ‫‪-٧‬‬
‫ﺃﻗﺼﻰ ﻤﺩﻯ ‪ ٨‬ﻤﺘﺭ‬ ‫أﺑﻌﺪ أﻳﺔ أﺟﻬﺰة آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى ﺗﺆﺛﺮ ﻋﻠﻰ ﻋﻤﻞ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬ ‫‪-٨‬‬

‫ﻭﺤﺩﺓ‬
‫ﺍﻟﺘﺤﻜﻡ ﺍﻻﺴﻠﻜﻴﺔ‬
‫‪ ٣-١٤‬ﺗﺮآﻴﺐ ﺣﺎﻣﻞ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬
‫ﻳﺘﻢ وﺿﻊ وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ ﻓﻰ اﻟﻤﻜﺎن اﻟﻤﺨﺼﺺ‬ ‫•‬ ‫ﻳﺘﻢ ﺗﺜﺒﻴﺖ اﻟﺤﺎﻣﻞ اﻟﺒﻼﺳﺘﻴﻚ ﻟﻮﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬ ‫•‬
‫ﻟﻬﺎ واﻟﻤﻮﺟﻮد ﻋﻠﻰ اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬ ‫ﻓﻲ اﻟﺤﺎﺋﻂ ﺑﺈﺳﺘﺨﺪام ﻣﺴﺎﻣﻴﺮ اﻟﺘﺜﺒﻴﺖ‪.‬‬

‫ﻣﺴﻤﺎر‬
‫ﺣﺎﻣﻞ وﺣﺪة اﻟﺘﺤﻜﻢ اﻻﺳﻠﻜﻴﺔ‬

‫‪٢٠‬‬
‫‪ -١٥‬ﺗﺮآﻴﺐ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ ١-١٥‬ﺧﻄﻮات اﻟﺘﺠﻬﻴﺰ ﻗﺒﻞ اﻟﺘﺮآﻴﺐ‬
‫ﻓﻚ ﻣﺴﻤﺎر ﺗﺜﺒﻴﺖ ﻏﻄﺎء ﻋﻠﺒﺔ اﻟﻜﻬﺮﺑﺎء‬ ‫ارﻓﻊ اﻟﻮﺣﺪة ﻣﻦ اﻟﻜﺮﺗﻮن‬ ‫ﺿﻊ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫)رﻗﻢ ‪ (١‬ﺛﻢ ﻓﻚ اﻟﻐﻄﺎء )رﻗﻢ ‪(٢‬‬ ‫آﻤﺎ هﻮ ﻣﺒﻴﻦ ﺑﺎﻟﺸﻜﻞ‬

‫‪٢‬‬

‫‪١‬‬

‫‪ ٢-١٥‬ﺧﻄﻮات ﺗﺮآﻴﺐ اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ) ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ‪( 38QFJ36-708‬‬


‫أﺟﺰاء اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ‪:‬‬
‫اﻟﻜﻤﻴﺔ‬ ‫اﺳﻢ اﻟﺠﺰء‬ ‫م‬
‫‪١‬‬ ‫اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ‬ ‫‪١‬‬
‫‪١‬‬ ‫اﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ‬ ‫‪٢‬‬
‫‪١‬‬ ‫اﻟﺰاوﻳﺔ اﻟﺨﻠﻔﻴﺔ‬ ‫‪٣‬‬
‫‪٢‬‬ ‫اﻟﺰاوﻳﺔ اﻷﻣﺎﻣﻴﺔ واﻟﻌﻠﻮﻳﺔ‬ ‫‪٤‬‬
‫‪٨‬‬ ‫ﺻﺎﻣﻮﻟﺔ‬ ‫‪٥‬‬
‫‪٨‬‬ ‫وردة‬ ‫‪٦‬‬
‫ﺧﻄﻮات ﺗﺠﻤﻴﻊ أﺟﺰاء اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ‪:‬‬
‫)‪ (١‬ﺗﺜﺒﻴﺖ اﻟﺰاوﻳﺔ اﻟﺨﻠﻔﻴﺔ ) رﻗﻢ ‪ ( ٣‬ﻣﻊ آﻞ ﻣﻦ اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ رﻗﻢ ) رﻗﻢ ‪ ( ١‬واﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ ) رﻗﻢ ‪( ٢‬‬
‫ﺑﺈﺳﺘﺨﺪام ﻋﺪد ‪ ٢‬ﺻﺎﻣﻮﻟﺔ ) رﻗﻢ ‪ ( ٥‬وﻋﺪد ‪ ٢‬وردة ) رﻗﻢ ‪.( ٦‬‬
‫)‪ (٢‬ﺗﺜﺒﻴﺖ اﻟﺰاوﻳﺔ اﻷﻣﺎﻣﻴﺔ ) رﻗﻢ ‪ ( ٤‬ﻣﻊ آﻞ ﻣﻦ اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ ) رﻗﻢ ‪ ( ١‬واﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ ) رﻗﻢ ‪( ٢‬‬
‫ﺑﺈﺳﺘﺨﺪام ﻋﺪد ‪ ٢‬ﺻﺎﻣﻮﻟﺔ ) رﻗﻢ ‪ ( ٥‬وﻋﺪد ‪ ٢‬وردة ) رﻗﻢ ‪.( ٦‬‬
‫)‪ (٣‬ﺗﺜﺒﻴﺖ اﻟﺰاوﻳﺔ اﻟﻌﻠﻮﻳﺔ ) رﻗﻢ ‪ ( ٤‬ﻣﻊ آﻞ ﻣﻦ اﻟﺠﺎﻧﺐ اﻷﻳﻤﻦ ) رﻗﻢ ‪ ( ١‬واﻟﺠﺎﻧﺐ اﻷﻳﺴﺮ ) رﻗﻢ ‪( ٢‬‬
‫ﺑﺈﺳﺘﺨﺪام ﻋﺪد ‪ ٤‬ﺻﺎﻣﻮﻟﺔ ) رﻗﻢ ‪ ( ٥‬وﻋﺪد ‪ ٤‬وردة ) رﻗﻢ ‪( ٦‬‬
‫‪٢‬‬
‫‪٢‬‬

‫‪٤‬‬
‫‪١‬‬ ‫‪٤‬‬
‫‪٥‬‬ ‫‪١‬‬
‫‪٣‬‬
‫‪٦‬‬ ‫‪٣‬‬
‫ﺗﻔﺎﺻﻴﻞ أ‬
‫أ‬
‫‪٤‬‬
‫اﻟﺸﻜﻞ اﻟﻨﻬﺎﺋﻰ ﺑﻌﺪ اﻟﺘﺠﻤﻴﻊ‬ ‫‪٤‬‬
‫ﻣﻼﺣﻈﺎت هﺎﻣﺔ ‪:‬‬
‫)‪ (١‬ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ وﺿﻊ اﻟﻮردة ﻗﺒﻞ اﻟﺼﺎﻣﻮﻟﺔ‪.‬‬
‫)‪ (٢‬ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ إﺣﻜﺎم رﺑﺎط اﻟﺼﺎﻣﻮﻟﺔ ﺣﺘﻰ ﺗﺼﺒﺢ اﻟﻮردة ﻣﺴﺘﻮﻳﺔ وﻳﻔﻀﻞ اﺳﺘﺨﺪام ﻣﻔﺘﺎح ﻋﺰم ﺑﺠﻴﺚ ﻳﻜﻮن ﻋﺰم‬
‫اﻟﺮﺑﺎط ‪ ٥٫٧‬ﻧﻴﻮﺗﻦ ﻣﺘﺮ‪.‬‬
‫)‪ (٣‬ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ اﻟﺘﺠﻤﻴﻊ اﻟﻨﻬﺎﺋﻰ ﻟﻠﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ﺑﺤﻴﺚ ﺗﻜﻮن ﻣﺴﺘﻮﻳﺔ وﻣﻄﺎﺑﻘﺔ ﻟﻠﺸﻜﻞ اﻟﻨﻬﺎﺋﻰ اﻟﻤﻮﺿﺢ ﺑﺎﻟﺮﺳﻢ‪.‬‬
‫ﺿﻊ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫ﺛﺒﺖ اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ﻋﻠﻰ اﻟﺤﺎﺋﻂ‬
‫اﻟﻮﺣﺪة‬
‫ﻋﻠﻰ اﻟﺘﺤﻤﻴﻠﺔ اﻷرﺿﻴﺔ‬ ‫ﺑﺤﻴﺚ ﺗﻜﻮن ﻣﺴﺘﻮﻳﺔ‬
‫اﻟﺨﺎرﺟﻴﺔ‬
‫ﺛﻢ ﺿﻊ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﻋﻠﻰ اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ‬
‫اﻟﺘﺤﻤﻴﻠﺔ‬ ‫اﻟﺘﺤﻤﻴﻠﺔ‬
‫اﻷرﺿﻴﺔ‬ ‫اﻟﺘﺮآﻴﺐ اﻷرﺿﻰ‬ ‫اﻟﺤﺎﺋﻄﻴﺔ‬ ‫اﻟﺘﺮآﻴﺐ اﻟﺤﺎﺋﻄﻰ‬

‫‪٢١‬‬
‫‪ -١٦‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١-١٦‬ﺧﺮﻳﻄﺔ ﺗﺮﺗﻴﺐ أﻋﻤﺎل ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫)‪ (١‬ﺗﺠﻬﻴﺰ اﻟﻤﻮاﺳﻴﺮ ﺑﺎﻟﻔﻠﻴﺮ‬

‫)‪ (٢‬ﺗﻮﺻﻴﻞ اﻟﻤﻮاﺳﻴﺮ‬

‫)‪ (٣‬ﻃﺮد اﻟﻬﻮاء‬

‫)‪ (٤‬اﺧﺘﻴﺎر ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن‬

‫)‪ (٥‬ﻋﺰل اﻟﻤﻮاﺳﻴﺮ‬

‫)‪ (٦‬ﻓﺘﺢ اﻟﻤﺤﺎﺑﺲ‬

‫‪٢٢‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ٢-١٦‬ﺗﻌﻠﻴﻤﺎت ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫ﺗﺠﻨﺐ اﻻرﺗﻔﺎع اﻟﺰاﺋﺪ ﻋﻦ اﻟﺤﺪ ﺑﻴﻦ آﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ‬


‫اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﻟﺘﻔﺎدي ﺗﻘﻠﻴﻞ آﻔﺎءة ﺟﻬﺎز‬
‫اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﺗﺠﻨﺐ اﻟﻤﺴﺎﻓﺔ اﻟﺰاﺋﺪة ﻋﻦ اﻟﺤﺪ ﺑﻴﻦ آﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ‬


‫اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﻟﺘﻔﺎدي ﺗﻘﻠﻴﻞ آﻔﺎءة ﺟﻬﺎز‬
‫اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﺗﺠﻨﺐ ﻋﻤﻞ اﻧﺤﻨﺎءات آﺜﻴﺮة ﻓﻰ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬


‫ﻋﻨﺪ ﺗﻮﺻﻴﻠﻬﺎ ﺑﺎﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﻟﺘﻔﺎدى‬
‫ﺗﻘﻠﻴﻞ آﻔﺎءة ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫ﻳﺠﺐ أن ﺗﻘﻮم ﺑﻔﺮد اﻟﻮﺻﻼت ﺑﻌﻨﺎﻳﺔ ﻗﺒﻞ ﺗﻮﺻﻴﻠﻬﺎ ﺑﻜﻞ ﻣﻦ‬


‫اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫‪ -‬ﻳﺆﺧﺬ ﻓﻲ اﻻﻋﺘﺒﺎر ﻋﻨﺪ ﺣﺴﺎب أﻃﻮال اﻟﻮﺻﻼت ﺟﻤﻴﻊ‬
‫اﻟﻤﻨﺤﻴﺎت‪.‬‬
‫‪ -‬ﻳﺠﺐ ﻋﺪم إزاﻟﺔ اﻷﻏﻄﻴﺔ اﻟﺒﻼﺳﺘﻴﻚ اﻟﻤﺎﻧﻌﺔ ﻟﻸﺗﺮﺑﺔ ﻣﻦ‬
‫ﻋﻠﻰ اﻟﻜﺎﺑﻠﻨﺞ أو اﻟﻤﻮاﺳﻴﺮ إﻻ ﻋﻨﺪﻣﺎ ﺗﻜﻮن وﺻﻼت‬
‫اﻟﻔﺮﻳﻮن ﺟﺎهﺰة ﻟﻠﺘﻮﺻﻴﻞ ﻣﻊ آﻞ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫واﻟﺨﺎرﺟﻴﺔ وذﻟﻚ ﻟﻠﻤﺤﺎﻓﻈﺔ ﻋﻠﻰ ﻧﻈﺎﻓﺔ اﻟﻤﻮاﺳﻴﺮ‪.‬‬
‫‪ -‬ﺗﺠﻨﺐ ﺣﺪوث ﺧﻔﺲ أو إﻋﻮﺟﺎج ﻓﻲ وﺻﻼت ﻣﻮاﺳﻴﺮ‬
‫اﻟﻔﺮﻳﻮن ﻋﻨﺪ ﺗﺸﻜﻴﻠﻬﺎ‪.‬‬
‫‪ -‬ﻳﺠﺐ ﻣﺮاﻋﺎة أن أﻗﻞ ﻧﺼﻒ ﻓﻄﺮ ﻟﺜﻨﻲ اﻟﻤﻮاﺳﻴﺮ ﻻ ﻳﻘﻞ‬
‫ﻋﻦ ‪ ١٠٠‬ﻣﻢ ﻟﺘﻔﺎدي ﺗﻠﻒ اﻟﻤﻮاﺳﻴﺮ‪.‬‬
‫‪ -‬ﻋﻨﺪ ﺛﻨﻲ اﻟﻤﻮاﺳﻴﺮ ﻳﺠﺐ ﻋﺪم ﻓﺮدهﺎ وﺛﻨﻴﻬﺎ ﻣﺮة أﺧﺮى‬
‫ﻋﻨﺪ ﻧﻔﺲ ﻣﻨﻄﻘﺔ اﻟﺜﻨﻲ ﻟﺼﻌﻮﺑﺔ ﺗﺸﻜﻴﻠﻬﺎ ﺑﻌﺪ ذﻟﻚ‪.‬‬

‫ﻤﻭﺍﺴﻴﺭ‬
‫ﻋﻨﺪ ﻋﻤﻞ ﺛﻨﻰ ﻓﻰ اﻟﻮﺻﻼت ﻳﺘﻢ ﻗﻄﻊ اﻟﻌﺎزل ﻋﻨﺪ ﻣﻨﻄﻘﺔ‬
‫اﻟﺜﻨﻰ وإزاﺣﺘﻪ ﺣﺘﻰ ﻳﺘﻢ اﻟﺜﻨﻰ ﺛﻢ إرﺟﺎﻋﻪ ﻣﺮة أﺧﺮى إﻟﻰ‬
‫ﻋﺎﺯل‬ ‫ﻣﻜﺎﻧﻪ واﺳﺘﺨﺪام ﺷﺮﻳﻂ ﻻﺻﻖ‪.‬‬

‫‪٢٣‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ٣-١٦‬اﺳﺘﻌﻤﺎل وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫اﻟﺠﺪول اﻟﺘﺎﻟﻲ ﻳﺒﻴﻦ اﺳﺘﻌﻤﺎل وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻨﻔﺲ أﻗﻄﺎر اﻟﻤﻮاﺳﻴﺮ اﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‬
‫‪ = L‬أﻗﺼﻰ ﻃﻮل ﻟﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫‪ = H‬أﻗﺼﻰ ارﺗﻔﺎع ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫)‪ (١‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ أﺳﻔﻞ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬


‫ﻗﻢ ﺑﻌﻤﻞ ﻣﻴﻮل ﺑﻤﻘﺪار )‪ ٦‬ﻣﻢ ﻟﻜﻞ ‪ ٣٠‬ﺳﻢ( ﻓﻰ ﻣﻮاﺳﻴﺮ اﻟﻐﺎز واﻟﺴﺎﺋﻞ اﻟﻮاﺻﻠﺔ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫ﺍﻟﻭﺤﺩﺓ‬
‫ﺘﺩﻓﺌﺔ‬
‫ﺍﻟﺩﺍﺨﻠﻴﺔ‬ ‫)ﻁﺭﺩ(‬

‫ﺘﺩﻓﺌﺔ‬
‫ﻣﺘﺮ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﺨﻁ‬
‫‪H L‬‬ ‫اﻟﺠﻬﺎز‬ ‫ﺨﻁ ﺍﻟﺴﺎﺌل‬ ‫ﺍﻟﻐﺎﺯ‬
‫‪١٠ ٢٥ 53QFJ36‬‬
‫‪١٥ ٣٠ 53QFJ48‬‬ ‫ﺘﺒﺭﻴﺩ‬
‫ﺘﺒﺭﻴﺩ )ﺴﺤﺏ(‬
‫‪١٥ ٣٠ 53KFJT60‬‬
‫ﺍﻟﻭﺤﺩﺓ‬
‫ﺍﻟﺨﺎﺭﺠﻴﺔ‬

‫)‪ (٢‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ أﻋﻠﻰ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬


‫أ ‪ -‬إذا آﺎن اﻹرﺗﻔﺎع ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ أﻗﻞ ﻣﻦ أو ﻳﺴﺎوي ‪ ٤‬ﻣﺘﺮ ﻳﺠﺐ وﺟﻮد ﻣﺼﻴﺪة زﻳﺖ ﺑﺤﻴﺚ ﺗﻜﻮن ﻗﺮﻳﺒﺔ ﻣﻦ‬
‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﻟﻤﻨﻊ رﺟﻮع اﻟﺰﻳﺖ إﻟﻰ اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻤﺒﺨﺮ ﻣﻤﺎ ﻳﻘﻠﻞ ﻣﻦ آﻔﺎءة ﻋﻤﻠﻴﺔ اﻟﺘﺒﺮﻳﺪ آﻤﺎ أن ﻣﺼﻴﺪة اﻟﺰﻳﺖ‬
‫ﺗﺴﻤﺢ ﺑﺮﺟﻮع اﻟﺰﻳﺖ إﻟﻰ اﻟﻀﺎﻏﻂ ﻟﻀﻤﺎن آﻔﺎءة ﺗﺸﻐﻴﻞ أﺟﺰاﺋﻪ اﻟﻤﻴﻜﺎﻧﻴﻜﻴﺔ‪.‬‬
‫ب‪ -‬إذا آﺎن اﻹرﺗﻔﺎع ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ أآﺒﺮ ﻣﻦ ‪ ٤‬ﻣﺘﺮ ﻳﺠﺐ وﺟﻮد أآﺜﺮ ﻣﻦ ﻣﺼﻴﺪة زﻳﺖ ﻓﻲ ﺧﻂ اﻟﻐﺎز ﺑﺤﻴﺚ ﺗﻜﻮن‬
‫ﻣﺼﻴﺪة اﻟﺰﻳﺖ اﻷوﻟﻰ ﻗﺮﻳﺒﺔ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وﺗﻜﻮن ﻣﺼﻴﺪة اﻟﺰﻳﺖ اﻟﺘﺎﻟﻴﺔ ﻋﻠﻰ ﺑﻌﺪ ‪ ٤‬ﻣﺘﺮ ﻣﻦ ﻣﺼﻴﺪة اﻟﺰﻳﺖ اﻷوﻟﻰ وهﻜﺬا‪.‬‬

‫ﺘﺩﻓﺌﺔ‬
‫)ﻁﺭﺩ(‬
‫ﺍﻟﻭﺤﺩﺓ‬
‫ﻣﺘﺮ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﺍﻟﺨﺎﺭﺠﻴﺔ‬
‫‪H L‬‬ ‫اﻟﺠﻬﺎز‬ ‫ﺨﻁ‬
‫ﺍﻟﻐﺎﺯ‬
‫‪١٠ ٢٥ 53QFJ36‬‬ ‫ﺘﺩﻓﺌﺔ‬
‫‪١٥ ٣٠ 53QFJ48‬‬
‫ﺨﻁ ﺍﻟﺴﺎﺌل‬
‫‪١٥ ٣٠ 53KFJT60‬‬
‫ﺘﺒﺭﻴﺩ‬
‫ﺍﻟﻭﺤﺩﺓ‬ ‫)ﺴﺤﺏ(‬ ‫ﺘﺒﺭﻴﺩ‬
‫ﺍﻟﺩﺍﺨﻠﻴﺔ‬

‫)‪ (٣‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻓﻰ ﻧﻔﺲ ﻣﺴﺘﻮى اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬


‫ﻳﻔﻀﻞ وﺟﻮد ﻣﺼﻴﺪة زﻳﺖ ﻓﻲ ﺧﻂ اﻟﻐﺎز ﺑﺤﻴﺚ ﺗﻜﻮن ﻗﺮﻳﺒﺔ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ﺣﺘﻰ ﻻ ﻳﺮﺟﻊ اﻟﺰﻳﺖ إﻟ ﻰ اﻟﻤﺒ ﺎدل اﻟﺤ ﺮاري ﻟﻠﻤﺒﺨ ﺮ‬
‫ﻣﻤﺎ ﻳﻘﻠﻞ ﻣﻦ آﻔﺎءة ﻋﻤﻠﻴﺔ اﻟﺘﺒﺮﻳﺪ آﻤﺎ أن ﻣﺼﻴﺪة اﻟﺰﻳﺖ ﺗﺴﻤﺢ ﺑﺮﺟﻮع اﻟﺰﻳﺖ إﻟﻰ اﻟﻀﺎﻏﻂ ﻟﻀﻤﺎن آﻔﺎءة ﺗﺸﻐﻴﻞ أﺟﺰاﺋﻪ اﻟﻤﻴﻜﺎﻧﻴﻜﻴﺔ‪.‬‬

‫ﻣﺘﺮ‬ ‫ﻣﻮدﻳﻞ‬ ‫ﺍﻟﻭﺤﺩﺓ‬ ‫‪L‬‬


‫‪L‬‬ ‫اﻟﺠﻬﺎز‬ ‫ﺍﻟﺩﺍﺨﻠﻴﺔ‬ ‫ﺨﻁ ﺍﻟﺴﺎﺌل‬
‫ﺍﻟﻭﺤﺩﺓ‬
‫‪٢٥‬‬ ‫‪53QFJ36‬‬ ‫ﺍﻟﺨﺎﺭﺠﻴﺔ‬
‫‪٣٠‬‬ ‫‪53QFJ48‬‬
‫ﺨﻁ ﺍﻟﻐﺎﺯ‬
‫‪٣٠‬‬ ‫‪53KFJT60‬‬
‫ﻤﺼﻴﺩﺓ ﺍﻟﺯﻴﺕ‬

‫‪٢٤‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫‪ ٤-١٦‬أﻗﻄﺎر وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫أﻗﺼﻰ ﻃﻮل‬ ‫ﻗﻄﺮ‬ ‫ﻗﻄﺮ‬ ‫ﻣﻮدﻳﻞ‬


‫ﻟﻮﺻﻼت اﻟﻤﻮاﺳﻴﺮ‬ ‫ﻣﺎﺳﻮرة اﻟﺴﺎﺋﻞ‬ ‫ﻣﺎﺳﻮرة اﻟﻐﺎز‬ ‫اﻟﺠﻬﺎز‬
‫‪ ٢٥‬ﻣﺘﺮ‬ ‫‪"٨/٣‬‬ ‫‪"٤/٣‬‬ ‫‪53QFJ36‬‬
‫‪ ٣٠‬ﻣﺘﺮ‬ ‫‪"٨/٣‬‬ ‫‪"٤/٣‬‬ ‫‪53QFJ48‬‬
‫‪ ٣٠‬ﻣﺘﺮ‬ ‫‪"٢/١‬‬ ‫‪"٨/٧‬‬ ‫‪53KFJT60‬‬

‫‪ ٥-١٦‬ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن‬
‫)‪ (١‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ ﻣﺸﺤﻮﻧﺔ ﺑﻜﻤﻴﺔ ﻓﺮﻳﻮن ﻣﻨﺎﺳﺒﺔ ﻟﻺﺳﺘﻌﻤﺎل ﻣﻊ وﺻﻼت اﻟﻔﺮﻳﻮن ﻃﻮل ‪ ٤‬ﻣﺘﺮ ﻣﻀﺎﻓ ًﺎ‬
‫إﻟﻴﻬﺎ ‪ ٥٠‬ﺟﺮام ﻓﺮﻳﻮن ﻟﻺﺳﺘﺨﺪام ﻓﻲ ﻃﺮد اﻟﻬﻮاء واﻟﻔﺮﻳﻮن‪.‬‬

‫)‪ (٢‬ﻋﻨﺪﻣﺎ ﻳﻜﻮن ﻃﻮل وﺻﻼت اﻟﻔﺮﻳﻮن أآﺒﺮ ﻣﻦ ‪ ٤‬ﻣﺘﺮ ﻓﺈﻧﻪ ﻳﻠﺰم إﺿﺎﻓﺔ آﻤﻴﺔ ﻓﺮﻳﻮن ‪ ٢٢‬ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ‬
‫ﺑﻤﻘﺪار ‪ ٢٥‬ﺟﺮام ﻟﻜﻞ ﻣﺘﺮ ﻃﻮﻟﻰ‪.‬‬

‫ﻣﺜﺎل ‪ :١‬ﻋﻨﺪﻣﺎ ﻳﻜﻮن ﻃﻮل وﺻﻼت اﻟﻔﺮﻳﻮن ‪ ٨‬ﻣﺘﺮ ﺗﻜﻮن آﻤﻴﺔ اﻟﻔﺮﻳﻮن اﻟﻤﻀﺎﻓﺔ = )‪ ١٠٠ = ٢٥ × (٤- ٨‬ﺟﺮام‬

‫ﻣﺜﺎل ‪ :٢‬ﻋﻨﺪﻣﺎ ﻳﻜﻮن ﻃﻮل وﺻﻼت اﻟﻔﺮﻳﻮن ‪ ١٢‬ﻣﺘﺮ ﺗﻜﻮن آﻤﻴﺔ اﻟﻔﺮﻳﻮن اﻟﻤﻀﺎﻓﺔ = )‪ ٢٠٠ = ٢٥ × (٤-١٢‬ﺟﺮام‬

‫)‪ (٣‬ﻣﻼﺣﻈﺎت‬
‫إذا آﺎﻧﺖ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن أزﻳﺪ ﻣﻦ اﻟﻼزم ﻓﺈن ذﻟﻚ ﻳﺆدي إﻟﻰ ﺣﺪوث ﻣﺸﺎآﻞ ﺗﺆدي إﻟﻰ ﺗﻠﻒ اﻟﻀﺎﻏﻂ ‪.‬‬ ‫•‬
‫إذا آﺎﻧﺖ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن أﻗﻞ ﻣﻦ اﻟﻼزم ﻓﺈم ذﻟﻚ ﻳﺆﺛﺮ ﻋﻠﻰ آﻔﺎءة اﻟﺘﺒﺮﻳﺪ واﻟﺘﺪﻓﺌﺔ‪.‬‬ ‫•‬

‫‪٢٥‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ٦-١٦‬وﺻﻒ ﺗﻮﺻﻴﻼت اﻟﻔﺮﻳﻮن ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫)‪ (١‬ﺍﻟﻤﺤﺒﺱ ﺍﻟﻔﻠﻴﺭ ﺍﻟﺨﺎﺹ ﺒﺎﻟﻐﺎﺯ‪.‬‬


‫)‪ (٢‬ﺼﻤﺎﻡ ﻗﻴﺎﺱ ﺍﻟﻀﻐﻁ ﺍﻟﺨﺎﺹ ﺒﻤﺤﺒﺱ ﺍﻟﻐﺎﺯ‪.‬‬ ‫‪١٠‬‬
‫)‪ (٣‬ﻤﻜﺎﻥ ﻓﺘﺢ ﻭﻏﻠﻕ ﻤﺤﺒﺱ ﺍﻟﻐﺎﺯ‪.‬‬
‫)‪ (٤‬ﻏﻁﺎﺀ ﺼﻤﺎﻡ ﻗﻴﺎﺱ ﺍﻟﻀﻐﻁ ﺍﻟﺨﺎﺹ ﺒﻤﺤﺒﺱ ﺍﻟﻐﺎﺯ‪.‬‬ ‫‪٦‬‬
‫)‪ (٥‬ﻏﻁﺎﺀ ﻤﻜﺎﻥ ﻓﺘﺢ ﻭﻏﻠﻕ ﻤﺤﺒﺱ ﺍﻟﻐﺎﺯ‪.‬‬ ‫‪٨‬‬ ‫‪٩،٧‬‬
‫)‪ (٦‬ﺍﻟﻤﺤﺒﺱ ﺍﻟﻔﻠﻴﺭ ﺍﻟﺨﺎﺹ ﺒﺎﻟﺴﺎﺌل‪.‬‬
‫)‪ (٧‬ﺼﻤﺎﻡ ﻗﻴﺎﺱ ﺍﻟﻀﻐﻁ ﺍﻟﺨﺎﺹ ﺒﻤﺤﺒﺱ ﺍﻟﺴﺎﺌل‪.‬‬ ‫‪١‬‬
‫)‪ (٨‬ﻤﻜﺎﻥ ﻓﺘﺢ ﻭﻏﻠﻕ ﻤﺤﺒﺱ ﺍﻟﺴﺎﺌل‪.‬‬
‫‪٣‬‬ ‫‪٢‬‬
‫)‪ (٩‬ﻏﻁﺎﺀ ﺼﻤﺎﻡ ﻗﻴﺎﺱ ﺍﻟﻀﻐﻁ ﺍﻟﺨﺎﺹ ﺒﻤﺤﺒﺱ ﺍﻟﺴﺎﺌل‪.‬‬ ‫‪٤‬‬
‫)‪ (١٠‬ﻏﻁﺎﺀ ﻤﻜﺎﻥ ﻓﺘﺢ ﻭﻏﻠﻕ ﻤﺤﺒﺱ ﺍﻟﺴﺎﺌل‪.‬‬ ‫‪٥‬‬
‫ﺗﻔﺎﺻﻴﻞ ﺗﻮﺻﻴﻼت اﻟﻔﺮﻳﻮن‬ ‫اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪ ٧-١٦‬وﺻﻒ ﺗﻮﺻﻴﻼت اﻟﻔﺮﻳﻮن ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬


‫ﺍﻟﻬﺎﻑ ﻴﻭﻨﻴﻭﻥ‬
‫ﺍﻟﺨﺎﺹ ﺒﻤﺎﺴﻭﺭﺓ ﺍﻟﻐﺎﺯ‬
‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﺘﻭﺼﻴﻼﺕ ﺍﻟﻔﺭﻴﻭﻥ‬
‫ﺍﻟﻬﺎﻑ ﻴﻭﻨﻴﻭﻥ‬
‫ﺍﻟﺨﺎﺹ ﺒﻤﺎﺴﻭﺭﺓ ﺍﻟﺴﺎﺌل‬

‫ﺗﻔﺎﺻﻴﻞ ﺗﻮﺻﻴﻼت اﻟﻔﺮﻳﻮن‬

‫)‪(١‬‬
‫‪ ٨-١٦‬وﺻﻒ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫)‪(٢‬‬
‫)‪ (١‬وﺻﻠﺔ ﻣﺎﺳﻮرة اﻟﻐﺎز‬
‫)‪ (٢‬وﺻﻠﺔ ﻣﺎﺳﻮرة اﻟﺴﺎﺋﻞ‬

‫‪ ٩-١٦‬اﻟﻤﻌﺪات اﻟﻼزﻣﺔ ﻟﺘﺠﻬﻴﺰ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫ﺗﺄآﺪ ﻣﻦ ﺗﻮﻓﻴﺮ اﻟﻤﻌﺪات اﻟﺘﺎﻟﻴﺔ ﻗﺒﻞ ﺗﺠﻬﻴﺰ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪:‬‬

‫ﻗﺎﻁﻌﺔ ﻤﻭﺍﺴﻴﺭ‬ ‫ﺁﻟﺔ ﻓﻠﻴﺭ‬

‫‪٢٦‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١٠-١٦‬ﺧﻄﻮات ﺗﺠﻬﻴﺰ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻗﺒﻞ اﻟﺘﻮﺻﻴﻞ‬
‫ﻗﺎﻁﻌﺔ ﻤﻭﺍﺴﻴﺭ‬ ‫ﺧﻄﻮة )‪ : (١‬ﻗﻄﻊ اﻟﻤﻮاﺳﻴﺮ ﻓﺮﻳﻮن‪:‬‬
‫• ﻓﻚ اﻷﻏﻄﻴﺔ اﻟﺒﻼﺳﺘﻴﻚ ﻣﻦ ﻧﻬﺎﻳﺎت ﻣﻮاﺳﻴﺮ‬
‫اﻟﻔﺮﻳﻮن‪.‬‬
‫• وﺟﻪ ﻧﻬﺎﻳﺔ اﻟﻤﺎﺳﻮرة إﻟﻰ أﺳﻔﻞ‪.‬‬
‫• اﻗﻄﻊ اﻟﻤﻮاﺳﻴﺮ اﻟﻨﺤﺎس ﺑﺎﺳﺘﺨﺪام ﻗﺎﻃﻌﺔ‬
‫اﻟﻤﻮاﺳﻴﺮ‪.‬‬
‫ﺍﻟﻘﻁﻊ‬ ‫ﺴﻁﺢ‬ ‫ﺴﻁﺢ‬ ‫ﺴﻁﺢ‬ ‫ﻣﻼﺣﻈﺎت‬
‫ﺍﻟﺴﻠﻴﻡ‬ ‫ﺍﻟﻘﻁﻊ‬ ‫ﺍﻟﻘﻁﻊ‬ ‫ﺍﻟﻘﻁﻊ‬ ‫• ﻳﺠﺐ أن ﻳﻜﻮن ﺳﻄﺢ اﻟﻘﻄﻊ ﻣﺴﺘﻘﻴﻤ ًﺎ – أﻧﻈﺮ‬
‫ﻤﺎﺌل‬ ‫ﻤﺘﻌﺭﺝ‬ ‫ﻏﻴﺭ‬ ‫اﻟﺮﺳﻮﻣﺎت اﻟﺘﻰ ﺗﻮﺿﺢ اﻟﻘﻄﻊ اﻟﺴﻠﻴﻢ واﻟﻐﻴﺮ ﺳﻠﻴﻢ‪.‬‬
‫ﻤﺴﺘﻘﻴﻡ‬

‫ﻗﺒل‬ ‫ﺒﻌﺩ‬
‫ﺧﻄﻮة )‪ : (٢‬إزاﻟﺔ اﻟﺰواﺋﺪ ﻣﻦ اﻟﻤﻮاﺳﻴﺮ‪:‬‬
‫‪١‬‬ ‫• ﻗﻢ ﺑﺈزاﻟﺔ ﺑﻄﺮف اﻟﻤﺎﺳﻮرة اﻟﻨﺤﺎس ﺑﺎﺳﺘﺨﺪام ﻣﺒﺮد‬
‫‪٢‬‬ ‫أو اﻟﺠﺰء اﻟﻤﺨﺼﺺ ﻟﺬﻟﻚ واﻟﻤﻮﺟﻮد ﺑﺴﻜﻴﻨﺔ اﻟﻔﻠﻴﺮ‬
‫ﻣﻊ ﻣﻼﺣﻈﺔ أن ﻳﻜﻮن ﻃﺮف اﻟﻤﺎﺳﻮرة اﻟﻨﺤﺎس‬
‫ﺇﺯﺍﻟﺔ‬ ‫ﻷﺳﻔﻞ ﻟﻤﻨﻊ دﺧﻮل اﻟﺰواﺋﺪ داﺧﻞ اﻟﻤﺎﺳﻮرة‪.‬‬
‫ﺍﻟﺭﺍﻴﺵ‬ ‫‪ : ١‬ﻣﺎﺳﻮرة‬
‫‪ : ٢‬ﺁﻟﺔ ﺗﻨﻈﻴﻒ اﻟﺮاﻳﺶ‬

‫ﺧﻄﻮة )‪ : (٣‬ﻋﻤﻞ اﻟﻔﻠﻴﺮ ﻟﻠﻤﻮاﺳﻴﺮ اﻟﻨﺤﺎس‬


‫• اﺳﺘﺨﺪم ﺁﻟﺔ اﻟﻔﻠﻴﺮ ﻟﺘﺸﻜﻴﻞ اﻟﻨﻬﺎﻳﺔ اﻟﻔﻠﻴﺮ‬
‫ﻟﻤﻮاﺳﻴﺮ اﻟﻐﺎز واﻟﺴﺎﺋﻞ‪.‬‬
‫• ﻗﻢ ﺑﺘﺮآﻴﺐ ﺁﻟﺔ اﻟﻔﻠﻴﺮ ﻋﻠﻰ اﻟﻤﺎﺳﻮرة وﻋﺪل‬
‫ﺁﻟﺔ ﺍﻟﻔﻠﻴﺭ‬ ‫ﺣﺴﺐ اﻟﻄﻠﺐ‪.‬‬

‫ﻣﻼﺣﻈﺎت‬
‫ﻤﺎﺴﻭﺭﺓ‬ ‫)‪ (١‬اﻟﻔﻠﻴﺮ اﻟﺠﻴﺪ ﻟﻪ اﻟﻤﻮاﺻﻔﺎت اﻟﺘﺎﻟﻴﺔ‪:‬‬
‫ﺼﺎﻤﻭﻟﺔ ﺍﻟﻔﻠﻴﺭ‬ ‫• اﻟﺴﻄﺢ اﻟﺪاﺧﻠﻰ ﻟﻠﻔﻠﻴﺮ ﻣﺼﻘﻮل وﻧﺎﻋﻢ‪.‬‬
‫• ﺣﺎﻓﺔ اﻟﻔﻠﻴﺮ ﻧﺎﻋﻤﺔ‪.‬‬
‫أﺑﻌﺎد اﻟﻔﻠﻴﺮ اﻟﺠﻴﺪ‬ ‫• اﻟﺠﻮاﻧﺐ اﻟﻤﺨﺮوﻃﻴﺔ ﻟﻠﻔﻠﻴﺮ ذات ﻃﻮل‬
‫‪+) A‬ﺻﻔﺮ –‪(,٤‬‬ ‫اﻟﻘﻄﺮ‬ ‫ﻣﺘﺴﺎوى )ﻣﺘﺠﺎﻧﺲ(‪.‬‬
‫‪ ١٣٫٢‬ﻣﻢ‬ ‫‪ ٨/٣‬ﺑﻮﺻﺔ ‪ ٩٫٥٢‬ﻣﻢ‬
‫‪ ٢٢٫٨٧‬ﻣﻢ‬ ‫‪ ٤/٣‬ﺑﻮﺻﺔ ‪ ١٩٫٠٥‬ﻣﻢ‬
‫‪ ١٦٫٦‬ﻣﻢ‬ ‫‪ ٢/١‬ﺑﻮﺻﺔ ‪ ١٢٫٧‬ﻣﻢ‬
‫ﺃﺒﻌﺎﺩ ﺍﻟﻔﻠﻴﺭ ﺍﻟﺠﻴﺩ‬ ‫‪ ٢٦٫٠٢‬ﻣﻢ‬ ‫‪ ٨/٧‬ﺑﻮﺻﺔ ‪ ٢٢٫٢٢‬ﻣﻢ‬

‫ﺗﺠﻨﺐ ﻋﻤﻞ أﺷﻜﺎل اﻟﻔﻠﻴﺮ اﻟﺨﺎﻃﺌﺔ اﻟﻤﻮﺿﺤﺔ‬


‫ﺑﺎﻷﺷﻜﺎل‪.‬‬

‫ﺃﺸﻜﺎل ﺍﻟﻔﻠﻴﺭ ﺍﻟﻐﻴﺭ ﺠﻴﺩ‬

‫‪٢٧‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫ﺗﺎﺑﻊ ‪ -‬ﺧﻄﻮات ﺗﺠﻬﻴﺰ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻗﺒﻞ اﻟﺘﻮﺻﻴﻞ‬

‫ﻤﺎﺴﻭﺭﺓ ﺍﻟﻐﺎﺯ‬
‫ﺒﺎﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬ ‫ﺧﻄﻮة )‪ : (٤‬ﻓﻚ ﺻﺎﻣﻮﻟﺘﻰ اﻟﻔﻠﻴﺮ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﺍﻟﻐﻁﺎﺀ ﺍﻟﺒﻼﺴﺘﻴﻙ‬
‫ﻟﻠﻬﺎﻑ ﻴﻭﻨﻴﻭﻥ‬
‫ﻓﻚ ﺻﺎﻣﻮﻟﺘﻰ اﻟﻔﻠﻴﺮ )اﻟﻐﺎز واﻟﺴﺎﺋﻞ( ﻣﻦ اﻟﻬﺎف ﻳﻮﻧﻴﻮن اﻟﻤﻮﺟﻮد‬
‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫ﻤﺎﺴﻭﺭﺓ ﺍﻟﺴﺎﺌل‬ ‫ﻣﻼﺣﻈﺎت‬


‫ﺒﺎﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬ ‫• ﻻ ﺗﻘﻢ ﺑﻔﻚ اﻟﺼﻮاﻣﻴﻞ اﻟﻔﻠﻴﺮ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ إﻻ ﻋﻨﺪ اﻟﻘﻴﺎم‬
‫ﺍﻟﻐﻁﺎﺀ ﺍﻟﺒﻼﺴﺘﻴﻙ‬ ‫ﺑﺘﺠﻬﻴﺰ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻟﻠﺘﻮﺻﻴﻞ‪.‬‬
‫ﻟﻠﻬﺎﻑ ﻴﻭﻨﻴﻭﻥ‬

‫ﺧﻄﻮة )‪ : (٥‬ﻓﻚ ﺻﺎﻣﻮﻟﺘﻰ اﻟﻔﻠﻴﺮ ﻣﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬


‫ﻓﻚ ﺻﺎﻣﻮﻟﺘﻲ اﻟﻔﻠﻴﺮ )اﻟﻐﺎز واﻟﺴﺎﺋﻞ( ﻣﻦ اﻟﻤﺤﺎﺑﺲ اﻟﻤﻮﺟﻮدة‬
‫ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫ﻣﻼﺣﻈﺎت‬
‫ﻻ ﺗﻘﻢ ﺑﻔﻚ اﻟﺼﻮاﻣﻴﻞ اﻟﺒﻼﺳﺘﻴﻚ ﻣﻦ ﻣﺤﺎﺑﺲ اﻟﻮﺣﺪة‬ ‫•‬
‫اﻟﺨﺎرﺟﻴﺔ إﻻ ﻋﻨﺪ اﻟﻘﻴﺎم ﺑﺘﺠﻬﻴﺰ وﺻﻼت ﻣﻮاﺳﻴﺮ‬
‫اﻟﻔﺮﻳﻮن ﻟﻠﺘﻮﺻﻴﻞ‪.‬‬
‫ﻓﻚ اﻟﺼﻮاﻣﻴﻞ اﻟﺒﻼﺳﺘﻴﻚ ﻣﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻗﺒﻞ‬ ‫•‬
‫ﺗﺮآﻴﺐ اﻟﻮﺣﺪة ﻋﻠﻰ اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ‪.‬‬

‫ﺧﻄﻮة )‪ : (٦‬ﺗﺮآﻴﺐ ﺻﻮاﻣﻴﻞ اﻟﻔﻠﻴﺮ ﻋﻠﻰ وﺻﻼت ﻣﻮاﺳﻴﺮ‬


‫ﺨﻁ ﺍﻟﺴﺎﺌل‬ ‫اﻟﻔﺮﻳﻮن‬
‫• ﻗﻢ ﺑﺘﺮآﻴﺐ ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻐﺎز‬
‫)اﻟﺼﺎﻣﻮﻟﺔ اﻟﻜﺒﻴﺮة( ﻋﻠﻰ ﻃﺮف ﻣﺎﺳﻮرة اﻟﻐﺎز‬
‫ﺨﻁ ﺍﻟﻐﺎﺯ‬ ‫ﺑﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪.‬‬
‫• ﻗﻢ ﺑﺘﺮآﻴﺐ ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ اﻟﺨﺎﺻﺔ ﺑﺎﻟﺴﺎﺋﻞ‬
‫ﻭﺼﻼﺕ ﻤﻭﺍﺴﻴﺭ ﺍﻟﻔﺭﻴﻭﻥ ﺒﻌﺩ ﺘﺭﻜﻴﺏ‬ ‫)اﻟﺼﺎﻣﻮﻟﺔ اﻟﺼﻐﻴﺮة( ﻋﻠﻰ ﻃﺮف ﻣﺎﺳﻮرة اﻟﺴﺎﺋﻞ ﺑﻮﺻﻼت‬
‫ﺼﻭﺍﻤﻴل ﺍﻟﻔﻠﻴﺭ ﻤﻥ ﻁﺭﻑ ﻭﺍﺤﺩ‬ ‫ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪.‬‬

‫ﺧﻄﻮة )‪ : (٧‬ﺗﺮآﻴﺐ ﺻﻮاﻣﻴﻞ اﻟﻔﻠﻴﺮ ﻋﻠﻰ اﻟﻄﺮف اﻵﺧﺮ‬


‫ﺨﻁ ﺍﻟﺴﺎﺌل‬ ‫ﻣﻦ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫• ﻗﻢ ﺑﺘﺮآﻴﺐ ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻐﺎز‬


‫)اﻟﺼﺎﻣﻮﻟﺔ اﻟﻜﺒﻴﺮة( ﻋﻠﻰ اﻟﻄﺮف اﻵﺧﺮ ﻟﻤﺎﺳﻮرة اﻟﻐﺎز‬
‫ﺨﻁ ﺍﻟﻐﺎﺯ‬ ‫ﺑﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪.‬‬

‫ﻭﺼﻼﺕ ﻤﻭﺍﺴﻴﺭ ﺍﻟﻔﺭﻴﻭﻥ ﺒﻌﺩ ﺘﺭﻜﻴﺏ‬ ‫• ﻗﻢ ﺑﺘﺮآﻴﺐ ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ اﻟﺨﺎﺻﺔ ﺑﺎﻟﺴﺎﺋﻞ‬
‫ﺼﻭﺍﻤﻴل ﺍﻟﻔﻠﻴﺭ ﻤﻥ ﺍﻟﻁﺭﻑ ﺍﻵﺨﺭ‬ ‫)اﻟﺼﺎﻣﻮﻟﺔ اﻟﺼﻐﻴﺮة( ﻋﻠﻰ اﻟﻄﺮف اﻵﺧﺮ ﻟﻤﺎﺳﻮرة اﻟﺴﺎﺋﻞ‬
‫ﺑﻮﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪.‬‬

‫‪٢٨‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١١-١٦‬ﺧﻄﻮات ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻣﻊ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫ﺗﻮﺻﻴﻞ وﺻﻠﺘﻰ ﻣﺎﺳﻮرﺗﻰ اﻟﻐﺎز واﻟﺴﺎﺋﻞ ﻣﻊ وﺻﻠﺘﻰ اﻟﻐﺎز واﻟﺴﺎﺋﻞ‬


‫ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪ .١‬وﺿﻊ زﻳﺖ ﺗﺒﺮﻳﺪ ﻋﻠﻰ ﻧﻬﺎﻳﺔ وﺻﻠﺔ ﻣﺎﺳﻮرة اﻟﻐﺎز أو اﻟﺴﺎﺋﻞ‬
‫ﻼ ﻤﻥ ﺯﻴﺕ‬‫ﻀﻊ ﻗﻠﻴ ﹰ‬ ‫وأﻳﻀ ًﺎ ﻋﻠﻰ ﻗﻼووظ وﺻﻠﺔ اﻟﻐﺎز أو اﻟﺴﺎﺋﻞ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫ﺍﻟﺘﺒﺭﻴﺩ ﻫﻨﺎ ﻭﻫﻨﺎ‬

‫هﺎف ﻳﻮﻧﻴﻮن‬ ‫ﺻﺎﻣﻮﻟﺔ‬ ‫ﻣﺎﺳﻮرة‬


‫اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫ﻓﻠﻴﺮ‬

‫ﻤﻭﺍﺴﻴﺭ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬
‫‪ .٢‬ﺗﺄآﺪ ﻣﻦ اﺳﺘﻘﺎﻣﺔ ﻣﺮآﺰ ﺳﻄﺢ اﻟﻔﻠﻴﺮ ﺛﻢ ﻗﻢ ﺑﺮﺑﺎط ﺻﺎﻣﻮﻟﺔ‬
‫اﻟﻔﻠﻴﺮ ﺑﺎﻟﻴﺪ ﻋﺪة ﻟﻔﺎت‪.‬‬

‫ﻭﺼﻼﺕ‬
‫ﻤﻭﺍﺴﻴﺭ ﺍﻟﻔﺭﻴﻭﻥ‬

‫ﻤﻔﺘﺎﺡ ﻋﺯﻡ‬
‫ﻭﺼﻼﺕ ﺍﻟﻔﺭﻴﻭﻥ‬ ‫‪ .٣‬أآﻤﻞ رﺑﺎط اﻟﺼﺎﻣﻮﻟﺔ ﺑﺎﺳﺘﺨﺪام ﻣﻔﺘﺎح ﻋﺰم ﻋﻠﻰ أن ﺗﺮاﻋﻰ‬
‫ﻨﺎﺤﻴﺔ ﺍﻟﺩﺍﺨل‬ ‫ﻗﻴﻢ اﻟﻌﺰم اﻟﻤﻮﺿﺤﺔ ﻓﻰ اﻟﺠﺪول ‪:‬‬

‫ﻣﻼﺣﻈﺎت‬
‫اﻟﺮﺑﻂ اﻟﻐﻴﺮ آﺎﻓﻰ ﻳﺆدى إﻟﻰ ﺣﺪوث ﺣﺎﻟﺔ ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن‪.‬‬ ‫•‬
‫ﻋﺰم رﺑﺎط ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ‬ ‫اﻟﺮﺑﻂ اﻟﺰاﺋﺪ ﻋﻦ اﻟﻤﻄﻠﻮب ﻳﺆدى إﻟﻰ ﺗﻠﻒ ﻓﻠﻴﺮ اﻟﻤﺎﺳﻮرة‬ ‫•‬
‫ﻋﺰم رﺑﺎط ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ‬ ‫ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ‬ ‫وﺑﺎﻟﺘﺎﻟﻰ ﺣﺪوث ﺣﺎﻟﺔ ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن‪.‬‬
‫آﺠﻢ × ﺳﻢ‬ ‫ﻧﻴﻮﺗﻦ × ﻣﺘﺮ‬ ‫ﻣﻢ‬ ‫ﺑﻮﺻﺔ‬
‫‪٣٥٠-٣١٠‬‬ ‫‪٣٥-٣١‬‬ ‫‪٩٫٥٢‬‬ ‫‪٨/٣‬‬
‫‪٧٦٠-٧٠٠‬‬ ‫‪٧٦-٧٠‬‬ ‫‪١٩٫٠٥‬‬ ‫‪٤/٣‬‬
‫‪٥٥٠-٥٠٠‬‬ ‫‪٥٥-٥٠‬‬ ‫‪١٢٫٧‬‬ ‫‪٢/١‬‬
‫‪٧٦٠-٧٠٠‬‬ ‫‪٧٦-٧٠‬‬ ‫‪٢٢٫٢٢‬‬ ‫‪٨/٧‬‬

‫‪ ١٢-١٦‬ﺧﻄﻮات ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻣﻊ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫‪ -‬ﺗﻮﺻﻴﻞ وﺻﻠﺘﻰ ﻣﺎﺳﻮرﺗﻰ اﻟﻐﺎز واﻟﺴﺎﺋﻞ ﻣﻊ وﺻﻠﺘﻰ اﻟﻐﺎز‬


‫واﻟﺴﺎﺋﻞ ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫‪ -‬أﻋﺪ اﻟﺨﻄﻮات )أ( ‪) ،‬ب( ‪) ،‬ج(‬

‫أآﻤﻞ رﺑﺎط ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ‬ ‫رﺑﻂ ﺻﺎﻣﻮﻟﺔ اﻟﻔﻠﻴﺮ ﺑﺎﻟﻴﺪ‬


‫ﺑﺎﺳﺘﺨﺪام ﻣﻔﺘﺎح اﻟﻌﺰم‬ ‫ﻋﺪة ﻣﺮات‬

‫‪٢٩‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١٣-١٦‬ﻃﺮد اﻟﻬﻮاء ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ووﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١-١٣-١٦‬ﻣﻘﺪﻣﺔ‬
‫ﻓﻰ ﺑﻌﺾ اﻟﺒﻼد ﻳﺤﻈﺮ اﻟﻘﺎﻧﻮن أن ﻳﺘﻢ ﻃﺮد اﻟﻬﻮاء ﻣﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻋﻦ ﻃﺮﻳﻖ ﺿﻐﻂ آﻤﻴﺔ ﻣﻦ اﻟﻔﺮﻳﻮن ﺧﻼل وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‪.‬‬
‫ﻓﻰ هﺬﻩ اﻟﺤﺎﻟﺔ ﻳﺘﻢ اﺳﺘﺨﺪام ﻃﻠﻤﺒﺔ ﺗﻔﺮﻳﻎ ﻟﻄﺮد اﻟﻬﻮاء ﻣﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫‪ ٢-١٣-١٦‬ﻃﺮد اﻟﻬﻮاء ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ووﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬


‫ﺑﺈﺳﺘﺨﺪام اﻟﻔﺮﻳﻮن اﻟﻤﻮﺟﻮد ﻓﻲ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫وﺟﻮد اﻟﻬﻮاء داﺧﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻳﺆدى إﻟﻰ أﺿﺮار ﺟﺎﻧﺒﻴﺔ وﻟﺬﻟﻚ ﻓﺈﻧﻪ ﻣﻦ اﻟﻀﺮورى ﻃﺮد اﻟﻬﻮاء ﻣﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺑﺈﺳﺘﺨﺪام‬
‫اﻟﻔﺮﻳﻮن اﻟﻤﻮﺟﻮد ﻓﻲ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫أﺿﺮار وﺟﻮد اﻟﻬﻮاء داﺧﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪:‬‬


‫زﻳﺎدة ﺿﻐﻮط اﻟﺘﺸﻐﻴﻞ‬ ‫ƒ‬
‫زﻳﺎدة اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻲ ﻟﻠﺘﺸﻐﻴﻞ‬ ‫ƒ‬
‫إﻧﺨﻔﺎض آﻔﺎءة اﻟﺘﺒﺮﻳﺪ‬ ‫ƒ‬
‫إﻧﺨﻔﺎض آﻔﺎءة اﻟﺘﺪﻓﺌﺔ‬ ‫ƒ‬
‫وﺟﻮد ﺳﺪد ﻓﻲ اﻟﻜﺎﺑﻠﺮي ﻧﺘﻴﺠﺔ ﺗﻜﻮن ﺛﻠﺞ‬ ‫ƒ‬
‫ﺗﺂآﻞ أﺟﺰاء داﺋﺮة اﻟﺘﺒﺮﻳﺪ ﻧﺘﻴﺠﺔ وﺟﻮد ﺑﺨﺎر اﻟﻤﺎء‬ ‫ƒ‬

‫ﻣﻼﺣﻈﺔ‬
‫اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ ﻣﺸﺤﻮﻧﺔ ﺑﻜﻤﻴﺔ ﻓﺮﻳﻮن ﻣﻨﺎﺳﺒﺔ ﻟﻺﺳﺘﻌﻤﺎل ﻣﻊ وﺻﻼت اﻟﻔﺮﻳﻮن‬
‫)ﻃﻮل ‪ ٤‬ﻣﺘﺮ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ( ﻣﻀﺎﻓ ًﺎ إﻟﻴﻬﺎ ‪ ٥٠‬ﺟﺮام ﻓﺮﻳﻮن ﻟﻺﺳﺘﺨﺪام ﻓﻲ ﻃﺮد اﻟﻬﻮاء ﻣﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫‪٣٠‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫ﺗﺎﺑﻊ ‪ -‬ﻃﺮد اﻟﻬﻮاء ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ووﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫ﺑﺈﺳﺘﺨﺪام اﻟﻔﺮﻳﻮن اﻟﻤﻮﺟﻮد ﻓﻲ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﺧﻄﻮات ﻃﺮد اﻟﻬﻮاء ‪:‬‬


‫‪ .١‬أﻋﺪ ﻓﺤﺺ ﺗﻮﺻﻴﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ‪.‬‬
‫‪ .٢‬ﻓﻚ ﺻﺎﻣﻮﻟﺔ ﻗﻠﺐ ﺻﻤﺎم اﻟﺴﺎﺋﻞ ﺛﻢ اﻓﺘﺢ ﺻﻤﺎم اﻟﺴﺎﺋﻞ ﺗﻘﺮﻳﺒ ًﺎ ‪ °٩٠‬ﻓﻲ اﺗﺠﺎﻩ ﻋﻜﺲ ﻋﻘﺎرب اﻟﺴﺎﻋﺔ‬
‫ﺑﺈﺳﺘﺨﺪام ﻣﻔﺘﺎح أﻟﻦ اﻧﺘﻈﺮ ﻣﺪة ‪ ١٠‬ﺛﻮاﻧﻲ ﺛﻢ أﻏﻠﻖ ﺻﻤﺎم اﻟﺴﺎﺋﻞ ‪.‬‬
‫‪ .٣‬اﺧﺘﺒﺮ ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن ﻋﻨﺪ ﺗﻮﺻﻴﻼت اﻟﻔﻠﻴﺮ ‪.‬‬
‫‪ .٤‬أﻃﺮد اﻟﻬﻮاء ﻣﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪:‬‬
‫• اﻓﺘﺢ ﺻﻤﺎم اﻟﺴﺎﺋﻞ ‪ .‬وﻓﻚ ﻏﻄﺎء ﺻﻤﺎم اﻟﺨﺪﻣﺔ اﻟﻤﻮﺟﻮد ﺑﺼﻤﺎم اﻟﻐﺎز ‪.‬‬
‫• اﺳﺘﺨﺪم ﻣﻔﺘﺎح أﻟﻦ ﺑﺮأس ﻣﺴﺪﺳﺔ ﻓﻲ اﻟﻀﻐﻂ ﻋﻠﻰ ﻗﻠﺐ ﺻﻤﺎم اﻟﺨﺪﻣﺔ‬
‫ﻟﻄﺮد اﻟﻬﻮاء ﻟﻤﺪة ‪ ٣‬ﺛﻮاﻧﻲ واﻧﺘﻈﺮ ﻟﻤﺪة دﻗﻴﻘﺔ واﺣﺪة‪.‬‬
‫‪ .٥‬اﺳﺘﺨﺪم ﻣﻔﺘﺎح ﻋﺰم ﻟﺮﺑﻂ ﻏﻄﺎء ﺻﻤﺎم اﻟﺨﺪﻣﺔ ﺑﻌﺰم ‪ ١٫٨‬آﺠﻢ ‪ .‬ﻣﺘﺮ ) ‪ ١٨‬ﻧﻴﻮﺗﻦ ‪ .‬ﻣﺘﺮ ( ‪.‬‬
‫‪ .٦‬اﻓﺘﺢ ﻗﻠﺐ ﺻﻤﺎم اﻟﻐﺎز ﻓﻲ اﺗﺠﺎﻩ ﻋﻜﺲ ﻋﻘﺎرب اﻟﺴﺎﻋﺔ ﺑﺈﺳﺘﺨﺪام ﻣﻔﺘﺎح أﻟﻦ ‪٤‬ﻣﻢ‪.‬‬
‫‪ .٧‬ﻗﻢ ﺑﺘﺮآﻴﺐ ﺻﺎﻣﻮﻟﺔ ﻗﻠﺐ آﻞ ﻣﻦ ﺻﻤﺎم اﻟﺴﺎﺋﻞ وﺻﻤﺎم اﻟﻐﺎز‪.‬‬
‫‪ .٨‬اﺧﺘﺒﺎر ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن‪.‬‬

‫اﺣﺘﻴﺎط‬

‫إذا ﺗﻢ اآﺘﺸﺎف ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن ﻓﻲ اﻟﺨﻄﻮة رﻗﻢ )‪ (٣‬ﻗﻢ ﺑﺈﺣﻜﺎم رﺑﺎط ﺗﻮﺻﻴﻼت اﻟﻤﻮاﺳﻴﺮ‬
‫• إذا ﺗﻮﻗﻒ ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن اﺳﺘﻤﺮ ﺑﺪءا ﻣﻦ اﻟﺨﻄﻮة رﻗﻢ )‪.(٤‬‬
‫• إذا ﻟﻢ ﻳﺘﻮﻗﻒ ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن ﻗﻢ ﺑﻔﺤﺺ ﻣﻜﺎن اﻟﺘﻨﻔﻴﺲ وإﺻﻼح اﻟﺘﻨﻔﻴﺲ ﺛﻢ أﻋﺪ ﺷﺤﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬
‫ﺑﺎﻟﻜﻤﻴﺔ اﻟﻤﻨﺎﺳﺒﺔ ﻟﺸﺤﻨﺔ اﻟﻔﺮﻳﻮن‪.‬‬

‫‪٣١‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫ﺗﺎﺑﻊ ‪ -‬ﻃﺮد اﻟﻬﻮاء ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ووﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ٣-١٣-١٦‬ﻃﺮد اﻟﻬﻮاء ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ووﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﺈﺳﺘﺨﺪام ﻃﻠﻤﺒﺔ ﺗﻔﺮﻳﻎ اﻟﻬﻮاء‬
‫ﻣﻼﺣﻈﺔ ‪:‬‬

‫ﻻ ﺗﺴﺘﺨﺪم اﻟﻀﺎﻏﻂ ﻟﻜﻲ ﻳﻘﻮم ﺑﻌﻤﻞ ﻃﻠﻤﺒﺔ اﻟﺘﻔﺮﻳﻎ ‪.‬‬


‫ﻗﺒﻞ ﺗﺸﻐﻴﻞ ﻃﻠﻤﺒﺔ اﻟﺘﻔﺮﻳﻎ ﻳﺠﺐ ﻓﺤﺺ ﻣﺴﺘﻮى اﻟﺰﻳﺖ اﻟﻤﻮﺟﻮد ﺑﻬﺎ ‪.‬‬

‫ﺧﻄﻮات ﻃﺮد اﻟﻬﻮاء‬

‫‪ .١‬ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﻃﻠﻤﺒﺔ ﺗﻔﺮﻳﻎ اﻟﻬﻮاء إﻟﻰ وﺻﻠﺔ اﻟﺨﺮﻃﻮم اﻷوﺳﻂ ﻣﻦ ﺟﻬﺎز ﺷﺤﻦ وﻗﻴﺎس ﺿﻐﻮط اﻟﻔﺮﻳﻮن‪.‬‬
‫‪ .٢‬ﻗﻢ ﺑﺈﺟﺮاء ﻋﻤﻠﻴﺔ ﺗﻔﺮﻳﻎ اﻟﻬﻮاء ﺗﻘﺮﻳﺒ ًﺎ ﻟﻤﺪة ﺳﺎﻋﺔ ‪.‬‬
‫• ﺗﺄآﺪ ﻣﻦ أن ﻣﺆﺷﺮ اﻟﻘﻴﺎس ﻗﺪ ﺗﺤﺮك ﻧﺎﺣﻴﺔ ‪ ٠,١ -‬ﻣﻠﻠﻲ ﺑﺴﻜﺎل ) ‪ ٧٦-‬ﺳﻢ زﺋﺒﻖ ( ‪.‬‬
‫‪ .٣‬ﻓﻚ اﻟﺨﺮﻃﻮم ﻣﻦ ﻃﻠﻤﺒﺔ اﻟﺘﻔﺮﻳﻎ ‪.‬‬
‫• إذا آﺎن اﻟﺰﻳﺖ اﻟﻤﻮﺟﻮد ﻓﻲ ﻃﻠﻤﺒﺔ اﻟﺘﻔﺮﻳﻎ ﻏﻴﺮ ﻧﻈﻴﻒ ﻳﺠﺐ اﺳﺘﺒﺪاﻟﻪ ‪.‬‬

‫‪٣٢‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١٤-١٦‬ﺧﺰﻳﻦ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن ) إﻋﺎدة اﻟﺘﺮآﻴﺐ (‬
‫ﻋﻤﻠﻴﺔ ﺗﺨﺰﻳﻦ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن ﻳﻌﻨﻰ إرﺟﺎع ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن إﻟﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﺑﺪون ﻓﻘﺪ اﻟﻔﺮﻳﻮن إﻟﻰ اﻟﺠﻮ‪.‬‬ ‫•‬
‫ﺗﺴﺘﺨﺪم ﻋﻤﻠﻴﺔ ﺗﺨﺰﻳﻦ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن ﻋﻨﺪ ﻧﻘﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ أو ﺻﻴﺎﻧﺘﻪ‪.‬‬ ‫•‬

‫ﺧﻄﻮات ﺗﺨﺰﻳﻦ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن‬

‫ﻓﻚ أﻏﻄﻴﺔ ﺻﻤﺎﻣﺎت اﻟﺴﺎﺋﻞ واﻟﻐﺎز ﺛﻢ ﺗﺄآﺪ ﻣﻦ ﻓﺘﺢ ﺻﻤﺎﻣﺎت اﻟﺴﺎﺋﻞ واﻟﻐﺎز ﺑﺈﺳﺘﺨﺪام ﻣﻔﺘﺎح أﻟﻦ ﻣﺴﺪس‪.‬‬ ‫‪.١‬‬
‫ﻗﻢ ﺑﺘﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻟﻤﺪة ‪ ١٠‬إﻟﻰ ‪ ١٥‬دﻗﺎﺋﻖ ‪.‬‬ ‫‪.٢‬‬
‫ﻗﻢ ﺑﺈﻳﻘﺎف ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ واﻧﺘﻈﺮ ﻣﺪة ‪ ٣‬دﻗﺎﺋﻖ وﻋﻨﺪﺋﺬ ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﺟﻬﺎز ﺷﺤﻦ اﻟﻔﺮﻳﻮن إﻟﻰ ﺻﻤﺎم اﻟﺨﺪﻣﺔ‬ ‫‪.٣‬‬
‫ﺑﺼﻤﺎم اﻟﺴﺤﺐ ‪.‬‬
‫ﻗﻢ ﺑﺈﺟﺮاء ﻋﻤﻠﻴﺔ ﻃﺮد اﻟﻬﻮاء ﻣﻦ ﺧﺮﻃﻮم اﻟﺸﺤﻦ ‪.‬‬ ‫‪.٤‬‬
‫اﻓﺘﺢ ﺗﺪرﻳﺠﻴ ًﺎ ﺻﻤﺎم اﻟﻀﻐﻂ اﻟﻤﻨﺨﻔﺾ اﻟﻤﻮﺟﻮد ﺑﺠﻬﺎز ﺷﺤﻦ وﻗﻴﺎس ﺿﻐﻮط اﻟﻔﺮﻳﻮن ‪.‬‬
‫أﻏﻠﻖ ﺻﻤﺎم اﻟﺴﺎﺋﻞ ‪.‬‬ ‫‪.٥‬‬
‫ﻗﻢ ﺑﺘﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻟﻜﻲ ﻳﻘﻮم ﺑﻌﻤﻴﺔ اﻟﺘﺒﺮﻳﺪ ﺛﻢ اوﻗﻒ ﺗﺸﻐﻴﻞ اﻟﺠﻬﺎز ﻋﻨﺪﻣﺎ ﻳﺸﻴﺮ ﻣﻘﻴﺎس اﻟﻀﻐﻂ إﻟﻰ‬ ‫‪.٦‬‬
‫‪ ٠,١‬ﻣﻠﻠﻲ ﺑﺴﻜﺎل ‪.‬‬
‫ﻓﻲ اﻟﺤﺎل أﻏﻠﻖ ﺻﻤﺎم اﻟﻐﺎز ﻋﻨﺪﻣﺎ ﻳﺸﻴﺮ ﻣﻘﻴﺎس اﻟﻀﻐﻂ ﻓﻲ اﻟﻨﻬﺎﻳﺔ إﻟﻰ ‪ ٠,٥ – ٠,٣‬ﻣﻠﻠﻲ ﺑﺴﻜﺎل ‪.‬‬ ‫‪.٧‬‬
‫ﻓﻚ ﺧﺮﻃﻮم ﺟﻬﺎز ﺷﺤﻦ وﻗﻴﺎس ﺿﻐﻮم اﻟﻔﺮﻳﻮن ﺛﻢ ﻗﻢ ﺑﺘﺮآﻴﺐ أﻏﻄﻴﺔ ﺻﻤﺎﻣﺎت اﻟﺴﺎﺋﻞ واﻟﻐﺎز‪.‬‬ ‫‪.٨‬‬
‫اﺳﺘﺨﺪم ﻣﻔﺘﺎح ﻋﺰم ﻟﺮﺑﻂ ﻏﻄﺎء ﺻﻤﺎم اﻟﺨﺪﻣﺔ ﺑﻌﺰم ‪ ١,٨‬آﺠﻢ‪.‬ﻣﺘﺮ ) ‪ ١٨‬ﻧﻴﻮﺗﻦ‪.‬ﻣﺘﺮ (‪.‬‬

‫‪٣٣‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫‪ ١٥-١٦‬اﺧﺘﺒﺎر اﻟﺘﻨﻔﻴﺲ‬

‫‪ -‬ﺑﻌﺪ اﻻﻧﺘﻬﺎء ﻣﻦ ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ آﻤﺎ‬
‫ﻳﺠﺐ ﻋﻤﻞ آﺸﻒ ﻋﺎم ﻋﻠﻰ اﻟﺘﻨﻔﻴﺲ ﻋﻠﻰ اﻟﻜﺎﺑﻠﻨﺞ ﺑﺎﺳﺘﻌﻤﺎل ﺟﻬﺎز اﺧﺘﺒﺎر اﻟﺘﻨﻔﻴﺲ‬
‫أو اﻟﺼﺎﺑﻮن اﻟﺴﺎﺋﻞ وذﻟﻚ ﻟﻠﺘﺄآﺪ ﻣﻦ ﻋﺪم ﺗﺴﺮب ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن‪.‬‬

‫ﺗﺠﻨﺐ ﻋﺪم اﻟﺮﺑﺎط اﻟﺠﻴﺪ ﻟﻮﺻﻼت اﻟﻔﺮﻳﻮن ﺑﻌﺪ‬


‫ﺗﻮﺻﻴﻠﻬﺎ ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‬
‫ﻟﺘﻔﺎدى ﺣﺎﻟﺔ ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن‪.‬‬

‫‪ ١٦-١٦‬ﻋﺰل وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬

‫ﺸﺭﻴﻁ‬ ‫ﻟﺘﻮﻓﻴﺮ اﻟﻄﺎﻗﺔ وﻣﻨﻊ ﺗﺴﺎﻗﻂ ﻗﻄﺮات ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻣﻦ‬ ‫‪-‬‬
‫ﻻﺼﻕ‬ ‫اﻟﻮﺻﻼت ﻓﺈﻧﻪ ﻳﺠﺐ ﻋﺰﻟﻬﺎ ﺟﻴﺪًا ﺑﺎﺳﺘﺨﺪام ﻧﻮﻋﻴﺔ ﻋﺰل‬
‫ﺟﻴﺪة‪.‬‬
‫ﺳﻤﻚ اﻟﻌﺰل ﻳﺠﺐ أﻻ ﻳﻘﻞ ﻋﻦ ‪ ٩‬ﻣﻢ‪.‬‬ ‫‪-‬‬
‫ﺍﻟﻤﺎﺴﻭﺭﺓ‬ ‫ﻣﺎدة اﻟﻌﺎزل ﻳﺠﺐ أن ﺗﻜﻮن ذات ﺧﻮاص ﻋﺰل ﺟﻴﺪة ‪ ،‬وﺳﻬﻠﺔ‬ ‫‪-‬‬
‫اﻻﺳﺘﺨﺪام وﻣﻘﺎوﻣﺔ ﻟﻠﺤﺮﻳﻖ وﻻ ﺗﻤﺘﺺ اﻟﺮﻃﻮﺑﺔ‪.‬‬
‫ﻋﺎﺯل‬
‫ﻳﻠﻒ اﻟﻜﺎﺑﻠﻨﺞ اﻟﻔﻠﻴﺮ وآﺬﻟﻚ اﻟﻤﻮاﺳﻴﺮ ﺑﺎﻟﻌﺎزل وﺗﺮﺑﻂ‬ ‫‪-‬‬
‫ﺍﻟﻤﺎﺴﻭﺭﺓ‬
‫ﺑﺎﻟﺸﺮﻳﻂ اﻟﻼﺻﻖ ﻣﻊ ﻣﺮاﻋﺎة ﻋﺪم ﺗﻌﺮﺿﻬﺎ ﻟﻠﻀﻐﻂ اﻟﺰاﺋﺪ‬
‫ﻣﻦ اﻟﺮﺑﺎط‪.‬‬

‫ﺗﺤﺬﻳﺮ‪:‬‬
‫• ﻣﻤﻨﻮع ﻣﺤﺎوﻟﺔ ﺛﻨﻰ اﻟﻤﻮاﺳﻴﺮ ﺑﻌﺪ ﻋﺰﻟﻬﺎ ﺧﺼﻮﺻ ًﺎ ﻓﻰ‬
‫ﻣﻨﺤﻨﻰ ﺿﻴﻖ ﻟﻌﺪم إﺗﻼﻓﻬﺎ‪.‬‬
‫• ﻳﺘﻢ ﻣﻌﺎﻟﺠﺔ أى ﻋﻴﺐ ﻳﻈﻬﺮ ﻓﻰ ﻣﺎدة اﻟﻌﺎزل‪.‬‬
‫• ﺗﺠﻨﺐ ﺗﺴﺎﻗﻂ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻧﺘﻴﺠﺔ ﻋﺪم ﻋﺰل اﻟﻤﻮاﺳﻴﺮ ﺟﻴﺪًا‪.‬‬

‫‪٣٤‬‬
‫‪ - ١٧‬ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻣﻊ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫ﻳﺘﻢ اﺳﺘﺨﺪام ﺧﺮﻃﻮم ‪ PVC‬ﻗﻄﺮ ﺧﺎرﺟﻲ ‪٢٦‬ﻣﻢ‬ ‫‰‬


‫ﻻﺻﻖ‬ ‫ﻣﻨﺎﺳﺐ ﻟﻺﺳﺘﺨﺪام ﻣﻊ ﻣﺎﺳﻮرة اﻟﺼﺮف‪.‬‬

‫ﺧﺮﻃﻮم‬ ‫ﻳﺘﻢ ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم اﻟﺘﺼﺮﻳﻒ ﺑﻤﺎﺳﻮرة اﻟﺼﺮف‬ ‫‰‬


‫اﻟﺘﺼﺮﻳﻒ‬ ‫ﺛﻢ ﺗﺜﺒﻴﺘﻪ ﺑﺈﺳﺘﺨﺪام ﺷﺮﻳﻂ ﻻﺻﻖ‪.‬‬

‫ﻳﺠﺐ ﻋﺰل ﺧﺮﻃﻮم اﻟﺘﺼﺮﻳﻒ ﻟﻌﺪم ﺣﺪوث ﺗﺸﺎﻗﻂ‬ ‫‰‬


‫ﻣﺎﺳﻮرة‬ ‫ﺷﺮﻳﻂ ﻻﺻﻖ‬ ‫ﻟﻤﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ داﺧﻞ اﻟﻐﺮﻓﺔ اﻟﻤﻜﻴﻔﺔ‪.‬‬
‫اﻟﺼﺮف‬ ‫ﻟﺘﻐﻄﻴﺔ ﺧﺮﻃﻮم اﻟﺘﺼﺮﻳﻒ‬

‫ﺗﻌﻠﻴﻤﺎت ﺗﺮآﻴﺐ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻣﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫أ‪ .‬ﻳﺠﺐ ﻋﺰل ﺧﺮﻃﻮم اﻟﺘﺼﺮﻳﻒ ﻟﻌﺪم ﺣﺪوث ﺗﺴﺎﻗﻂ ﻟﻤﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ داﺧﻞ اﻟﻐﺮﻓﺔ اﻟﻤﻜﻴﻔﺔ‬

‫ب‪ .‬ﻳﺠﺐ أن ﻳﻤﻴﻞ ﺧﺮﻃﻮم اﻟﺘﺼﺮﻳﻒ ﺗﺪرﻳﺠﻴ ًﺎ إﻟﻰ أﺳﻔﻞ ﻧﺎﺣﻴﺔ ﻣﺨﺮج اﻟﺘﺼﺮﻳﻒ ﻟﻀﻤﺎن اﻧﺴﻴﺎب ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ إﻟﻰ اﻟﺨﺎرج‪.‬‬

‫ج‪ .‬ﻳﺠﺐ ﻣﺮاﻋﺎة ﺳﻬﻮﻟﺔ ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ ﻣﻦ ﻣﺨﺮج اﻟﺘﺼﺮﻳﻒ ﺣﺘﻰ ﻻ ﻳﺤﺪث ﺗﺴﺎﻗﻂ ﻟﻤﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﺧﺎرج اﻟﻮﺣﺪة‪.‬‬

‫د‪.‬ﻳﺠﺐ ﻣﺮاﻋﺎة ﻋﺪم ﺗﻮﺟﻴﻪ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ إﻟﻰ أﻋﻠﻰ وذﻟﻚ ﻟﺘﺠﻨﺐ إﻋﺎﻗﺔ ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‪.‬‬

‫هـ‪ .‬ﻳﺠﺐ ﻣﺮاﻋﺎة ﻋﺪم وﺟﻮد اﻟﺘﻮاءات أو اﻧﺤﻨﺎءات ﻓﻰ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ وذﻟﻚ ﻟﺘﺠﻨﺐ إﻋﺎﻗﺔ ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻧﺘﻴﺠﺔ‬
‫وﺟﻮد هﻮاء راآﺪ داﺧﻞ اﻟﺨﺮﻃﻮم‪.‬‬

‫ﺘﺠﻨﺏ ﺍﻻﻟﺘﻭﺍﺀﺍﺕ ﺃﻭ ﺍﻻﻨﺤﻨﺎﺀﺍﺕ ﺍﻷﻓﻘﻴﺔ ﻓﻰ ﺨﺭﻁﻭﻡ‬ ‫ﺘﺠﻨﺏ ﺍﻻﻟﺘﻭﺍﺀﺍﺕ ﺃﻭ ﺍﻻﻨﺤﻨﺎﺀﺍﺕ ﺍﻟﺭﺃﺴﻴﺔ ﻓﻰ ﺨﺭﻁﻭﻡ‬
‫ﺍﻟﺘﺼﺭﻴﻑ ﺍﻟﺘﻰ ﺘﻌﻭﻕ ﺘﺼﺭﻴﻑ ﻤﻴﺎﻩ ﺍﻟﺘﻜﺜﻴﻑ‬ ‫ﺍﻟﺘﺼﺭﻴﻑ ﺍﻟﺘﻰ ﺘﻌﻭﻕ ﺘﺼﺭﻴﻑ ﻤﻴﺎﻩ ﺍﻟﺘﻜﺜﻴﻑ‬
‫ﻳﺘﻢ اﺧﺘﺒﺎر ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﻋﻦ ﻃﺮﻳﻖ ﺻﺐ ﺑﻌﺾ اﻟﻤﺎء داﺧﻞ ﺣﻮض ﺻﺮف اﻟﻮﺣﺪة واﻟﺘﺄآﺪ ﻣﻦ ﺣﺴﻦ ﺗﺼﺮﻳﻒ‬ ‫و‪-‬‬
‫اﻟﻤﻴﺎﻩ وﻋﺪم وﺟﻮد ﺗﻨﻔﻴﺲ ﻣﻦ اﻷﺟﺰاء اﻷﺧﺮى‪.‬‬

‫‪٣٥‬‬
‫‪ -١٨‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫‪ ١-١٨‬اﺣﺘﻴﺎﻃﺎت اﻷﻣﺎن اﻟﺨﺎﺻﺔ ﺑﺎﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﻦ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻰ إﻟﻰ ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬

‫ﺘﺤﺫﻴﺭ اﻷﻋﻤﺎل اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﺗﻲ ﺗﺸﻤﻞ اﺧﺘﻴﺎر وﺗﺮآﻴﺐ ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وﺟﻤﻴﻊ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻤﺼﺪر‬
‫اﻟﻜﻬﺮﺑﺎﺋﻰ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ هﻰ ﻣﺴﺌﻮﻟﻴﺔ اﻟﻌﻤﻴﻞ وﻳﺠﺐ أن ﺗﺘﻢ ﻃﺒﻘًﺎ ﻟﻤﻮاﺻﻔﺎت اﻷﻣﺎن اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻘﻴﺎﺳﻴﺔ‬
‫ﺑﻮاﺳﻄﺔ ﻓﻨﻰ آﻬﺮﺑﺎء ﻣﺆهﻞ ﻟﻬﺬا اﻟﻌﻤﻞ ﺣﺘﻰ ﻻ ﺗﺤﺪث أﺧﻄﺎء ﻓﻲ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺗﺆدي إﻟﻰ ﺣﺪوث ﺣﺎﻻت اﻟﻘﺼﺮ‬ ‫!‬
‫اﻟﻜﻬﺮﺑﺎﺋﻰ واﻟﺤﺮﻳﻖ‪.‬‬

‫أو ًﻻ ‪ -‬ﻓﻮﻟﺖ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ‪:‬‬


‫ﻳﺠﺐ أن ﻳﻜﻮن ﻓﻮﻟﺖ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ﻋﻨﺪ ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻓﻰ ﺣﺪود اﻟﻘﻴﻢ اﻟﻤﻮﺿﺤﺔ ﺑﻠﻮﺣﺎت اﻟﺒﻴﺎﻧﺎت‬
‫اﻟﺠﻬﺎز واﻟﻤﺜﺒﺘﺔ ﻋﻠﻰ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪.‬‬

‫ﺛﺎﻧﻴ ًﺎ‪ -‬ﻋﺪاد اﻟﻘﺪرة اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ‪:‬‬


‫ﻳﺠﺐ أن ﺗﻜﻮن ﻗﺪرة اﻟﻌﺪاد اﻟﻜﻬﺮﺑﺎﺋﻰ ﻟﺪى اﻟﻌﻤﻴﻞ أآﺒﺮ ﻣﻦ اﻻﺳﺘﻬﻼك اﻟﻜﻬﺮﺑﺎﺋﻰ اﻟﻜﻠﻰ ﻟﻠﻤﻜﺎن اﻟﻤﺮاد ﺗﻜﻴﻴﻔﻪ ﻣﻊ اﻷﺧﺬ ﻓﻰ‬
‫اﻻﻋﺘﺒﺎر ﺟﻤﻴﻊ أﺟﻬﺰة اﻟﺘﻜﻴﻴﻒ اﻟﻤﺮاد ﺗﺮآﻴﺒﻬﺎ ﺑﺎﻹﺿﺎﻓﺔ إﻟﻰ أﻳﺔ أﺟﻬﺰة آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى ﻣﻮﺟـﻮدة ﻓﻰ اﻟﻤﻜﺎن‪ .‬وﻓﻰ ﺣﺎﻟﺔ ﻋﺪم‬
‫ﺗﻮاﻓﺮ ذﻟﻚ ﻳﺠﺐ اﺳﺘﺒﺪال اﻟﻌﺪاد اﻟﻜﻬﺮﺑﺎﺋﻲ وﻻ ﻳﺘﻢ ﺗﺸﻐﻴﻞ أﺟﻬﺰة اﺳﺘﻬﻼآﻬﺎ أآﺜﺮ ﻣﻦ ﻗﺪرة اﻟﻌﺪاد اﻟﻜﻬﺮﺑﺎﺋﻲ إﻻ ﺑﺎﻟﺘﻨﺎوب‪.‬‬

‫ﺛﺎﻟﺜ ًﺎ‪ -‬ﻟﻮﺣﺔ اﻟﺘﻮزﻳﻊ اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺮﺋﻴﺴﻴﺔ‪:‬‬


‫* ﻳﺠﺐ أن ﻳﻜﻮن ﻋﻨﺪ اﻟﻌﻤﻴﻞ ﻟﻮﺣﺔ ﺗﻮزﻳﻊ آﻬﺮﺑﺎﺋﻴﺔ رﺋﻴﺴﻴﺔ ﻣﻮﺻﻠﺔ ﺑﻌﺪ اﻟﻌﺪاد اﻟﻜﻬﺮﺑﺎﺋﻰ ﻣﺒﺎﺷﺮة وأن ﺗﻜﻮن هﺬﻩ اﻟﻠﻮﺣﺔ ﻣﺰودة‬
‫ﺑﻤﻔﺎﺗﻴﺢ آﻬﺮﺑﺎء ﻣﺰودة ﺑﻘﻮاﻃﻊ أوﺗﻮﻣﺎﺗﻴﻜﻴﺔ ﻟﻠﻮﻗﺎﻳﺔ ﻣﻦ زﻳﺎدة اﻟﺤﻤﻞ )أوﻓﺮﻟﻮدات( ﻳﺘﻢ ﺗﻮزﻳﻊ اﻷﺣﻤﺎل اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻋﻠﻴﻬﺎ ﺑﻄﺮﻳﻘﺔ‬
‫ﺻﺤﻴﺤﺔ ﺑﺤﻴﺚ‪:‬‬
‫* ﻳﺠﺐ أن ﻳﻜﻮن ﻟﻜﻞ ﺟﻬﺎز ﺗﻜﻴﻴﻒ ﻣﻔﺘﺎح آﻬﺮﺑﺎء ﻣﻨﻔﺼﻞ ﺧﺎص ﺑﻪ ﻋﻠﻰ ﻟﻮﺣﺔ اﻟﺘﻮزﻳﻊ اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﻣﺰود ﺑﻘﺎﻃﻊ أوﺗﻮﻣﺎﺗﻴﻜﻰ‬
‫ﻟﻠﻮﻗﺎﻳﺔ ﻣﻦ زﻳﺎدة اﻟﺤﻤﻞ )أوﻓﺮﻟﻮد(‪.‬‬
‫* ﻻ ﻳﺘﻢ ﺗﻮﺻﻴﻞ أآﺜﺮ ﻣﻦ ﺟﻬﺎز ﺗﻜﻴﻴﻒ ﻋﻠﻰ ﺧﻂ آﻬﺮﺑﺎء واﺣﺪ‪.‬‬
‫* ﻻ ﻳﺘﻢ ﺗﻮﺻﻴﻞ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺑﺄﻳﺔ داﺋﺮة آﻬﺮﺑﺎﺋﻴﺔ ﻓﺮﻋﻴﺔ ﺗﻐﺬى ﻓﻰ ﻧﻔﺲ اﻟﻮﻗﺖ ﻋﺪة ﻣﺨﺎرج‬
‫ﻟﻺﺿﺎءة أو أﻳﺔ أﺟﻬﺰة آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى ﺑﺤﻴﺚ ﺗﻜﻮن هﺬﻩ اﻷﺣﻤﺎل اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻤﺸﺘﺮآﺔ آﺒﻴﺮة ﺑﺪرﺟﺔ ﺗﺆﺛﺮ ﻋﻠﻰ ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ‬
‫ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬
‫راﺑﻌ ًﺎ‪ -‬ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ ‪:‬‬
‫* ﻳﺠﺐ ﺗﺮآﻴﺐ ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ أوﺗﻮﻣﺎﺗﻴﻜﻰ ﻃﺮﻓﻴﻦ ﻟﺘﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬
‫* ﻳﺠﺐ ﺗﺮآﻴﺐ ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ ﺑﺸﺮط أن ﻳﻜﻮن ﺑﻌﻴﺪا ﻋﻦ أﻳﺔ ﻣﻮاد ﻗﺎﺑﻠﺔ ﻟﻼﺷﺘﻌﺎل ﻣﺜﻞ‬
‫) اﻟﺴﺘﺎﺋﺮ ‪ -‬اﻟﺪواﻟﻴﺐ ‪ -‬اﻟﺪﻳﻜﻮرات اﻟﺨﺸﺒﻴﺔ ‪ -‬اﻟﻤﻮآﻴﺖ اﻟﺦ (‪.‬‬
‫ﺗﺤﺬﻳﺮات‪:‬‬
‫* ﺗﺤﺬﻳﺮ‪ : ١‬ﻳﺠﺐ أﻻ ﻳﺴﺘﺨﺪم أى ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺧﻼف ﻣﻔﺎﺗﻴﺢ اﻟﺘﺸﻐﻴﻞ ذات اﻟﻤﺎرآﺎت اﻟﻤﻌﺘﻤﺪة ﻟﻼﺳﺘﺨﺪام ﻣﻊ أﺟﻬﺰة اﻟﺘﻜﻴﻴﻒ‪.‬‬
‫* ﺗﺤﺬﻳﺮ‪ : ٢‬ﻳﺠﺐ أن ﻳﻜﻮن ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ ﻣﻨﺎﺳﺒﺎ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ اﻟﺨﺎص ﺑﻪ أﻧﻈﺮ ﺟﺪول اﻟﺒﻴﺎﻧﺎت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺻﻔﺤﺔ )‪(٣٨‬‬
‫ﺧﺎﻣﺴًﺎ ‪ -‬اﻟﻜﺎﺑﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ ‪:‬‬
‫* ﻳﺠﺐ أن ﻳﻜﻮن اﻟﻜﺎﺑﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ اﻟﻮاﺻﻞ ﺑﻴﻦ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻲ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻄﺎﺑﻘ ًﺎ ﻟﻤﻮاﺻﻔﺎت اﻷﻣﺎن‬
‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺄﺟﻬﺰة ﺗﻜﻴﻴﻒ اﻟﻬﻮاء‪.‬‬
‫* ﻳﺠﺐ أن ﻳﻜﻮن اﻟﻜﺎﺑﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ اﻟﻮاﺻﻞ ﺑﻴﻦ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻰ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺟﺰءًا واﺣﺪًا ﻟﻴﺴﺖ ﺑﻪ أﻳﺔ‬
‫اﻣﺘﺪادات‪.‬‬
‫* ﻳﺠﺐ أن ﻳﻜﻮن ﻣﻘﺎس اﻟﻜﺎﺑﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ اﻟﻮاﺻﻞ ﺑﻴﻦ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻰ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻨﺎﺳﺐ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ‬
‫وذﻟﻚ ﺑﻄﻮل اﻟﻜﺎﺑﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ ﺣﺘﻰ ‪ ٣٠‬ﻣﺘﺮ‪ .‬أﻧﻈﺮ ﺟﺪول اﻟﺒﻴﺎﻧﺎت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺻﻔﺤﺔ )‪. (٣٨‬‬
‫ﺳﺎدﺳًﺎ ‪ -‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ‪:‬‬
‫أ‪ .‬ﻳﺘﻢ ﺗﻮﺻﻴﻞ اﻟﻄﺮف اﻷرﺿﻰ ﻗﺒﻞ أى ﺗﻮﺻﻴﻼت آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى‪.‬‬
‫ب‪ .‬ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ إﺟﺮاء اﻟﺘﻮﺻﻴﻞ إﻟﻰ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ﻣﻦ ﺧﻼل ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﻳﻜﻮن أﻗﻞ ﺧﻠﻮص ﺑﻴﻦ ﻧﻘﻂ‬
‫ﺗﻮﺻﻴﻠﻪ ‪ ٣‬ﻣﻢ‪ .‬وﻳﻘﻮم هﺬا اﻟﻤﻔﺘﺎح ﺑﺎﻟﻔﺼﻞ اﻟﻜﻠﻰ ﻟﻸﻗﻄﺎب اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪.‬‬
‫ج‪ .‬ﻳﺠﺐ ﺗﺠﻨﺐ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻐﻴﺮ ﺟﻴﺪة )اﻟﻤﻬﺘﺰة – اﻟﻐﻴﺮ ﻣﺮﺑﻮﻃﺔ ﺟﻴﺪًا( ﻣﻦ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻰ إﻟﻰ ﻣﻔﺘﺎح‬
‫ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وذﻟﻚ ﻟﺘﻔﺎدى ﺣﺪوث اﻟﺘﺤﻤﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ ﻧﺘﻴﺠﺔ اﻧﺨﻔﺎض اﻟﻔﻮﻟﺖ واﻟﺬى ﻳﺆدى إﻟﻰ ﺣﺪوث‬
‫أﻋﻄﺎل آﻬﺮﺑﺎﺋﻴﺔ ﻋﻨﺪ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬

‫‪٣٦‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫‪ ٢-١٨‬اﺣﺘﻴﺎﻃﺎت اﻷﻣﺎن اﻟﺨﺎﺻﺔ ﺑﺎﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ واﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ و ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬

‫ﺟﻤﻴﻊ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ واﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ و ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ هﻰ ﻣﺴﺌﻮﻟﻴﺔ ﻓﻨﻰ‬ ‫ﺘﺤﺫﻴﺭ‬
‫ﺗﺮآﻴﺐ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وﻳﺠﺐ أن ﺗﺘﻢ ﻃﺒﻘ ًﺎ ﻟﻤﻮﺻﻔﺎت اﻷﻣﺎن اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻘﻴﺎﺳﻴﺔ ﺣﺘﻰ ﻻ ﺗﺤﺪث أﺧﻄﺎء ﻓﻲ اﻟﺘﻮﺻﻴﻼت‬
‫!‬
‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺗﺆدي إﻟﻰ ﺣﺪوث ﺣﺎﻻت اﻟﻘﺼﺮ اﻟﻜﻬﺮﺑﺎﺋﻰ واﻟﺤﺮﻳﻖ‪.‬‬

‫ﻼ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ ﻣﻦ اﻟﻤﺼﻨﻊ آﺎﻣﻠﺔ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺪاﺧﻠﻴﺔ ‪.‬‬


‫‪ -‬ﺗﺨﺮج آ ً‬
‫‪ -‬ﻳﺮاﻋﻰ ﻋﺪم إﺟﺮاء أﻳﺔ ﺗﻐﻴﻴﺮات ﻓﻰ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻤﻮﺟﻮدة داﺧﻞ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ‪.‬‬
‫‪ -‬ﻗﺒﻞ اﻟﺒﺪء ﻓﻰ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ أن اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺮﺋﻴﺴﻴﺔ ﻣﻦ‬
‫اﻟﻌﺪاد اﻟﻜﻬﺮﺑﺎﺋﻰ ﺣﺘﻰ ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮﺻﻠﺔ ﺑﻄﺮﻳﻘﺔ ﺻﺤﻴﺤﺔ ﻟﺘﻼﻓﻰ أى ﺗﺤﻤﻴﻞ آﻬﺮﺑﺎﺋﻰ ﻳﺆدى إﻟﻰ ﺗﻠﻒ‬
‫ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪ ،‬ﻟﺬا ﻳﺠﺐ ﻣﺮاﻋﺎة اﻟﻨﻘﺎط اﻟﺘﺎﻟﻴﺔ ﻋﻨﺪ إﺟﺮاء اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‬
‫وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪:‬‬

‫أوﻻ ‪ -‬ﻓﻮﻟﺖ اﻟﺘﺸﻐﻴﻞ‪:‬‬


‫ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ أن ﻓﻮﻟﺖ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻋﻨﺪ اﻟﻌﻤﻴﻞ ﻓﻰ ﺣﺪود اﻟﻘﻴﻢ اﻟﻤﻮﺿﺤﺔ ﺑﻠﻮﺣﺔ ﺑﻴﺎﻧﺎت اﻟﺠﻬﺎز واﻟﻤﺜﺒﺘﺔ ﻋﻠﻰ‬
‫اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪.‬‬

‫ﺛﺎﻧﻴ ًﺎ ‪ -‬اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ‪:‬‬


‫* ﻳﺠﺐ أن ﺗﻜﻮن اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﻄﺎﺑﻘﺔ ﻟﻤﻮاﺻﻔﺎت اﻷﻣﺎن اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺄﺟﻬﺰة ﺗﻜﻴﻴﻒ اﻟﻬﻮاء ‪.‬‬
‫* ﻳﺠﺐ أن ﻳﻜﻮن آﻞ آﺎﺑﻞ آﻬﺮﺑﺎﺋﻲ ﺟﺰءًا واﺣﺪًا ﻟﻴﺴﺖ ﺑﻪ أﻳﺔ إﻣﺘﺪادات ﺗﺆدي إﻟﻰ ﺣﺪوث أﻋﻄﺎل آﻬﺮﺑﺎﺋﻴﺔ ﻋﻨﺪ ﺗﺸﻐﻴﻞ‬
‫ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪.‬‬

‫ﺛﺎﻟﺜ ًﺎ ‪ -‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪:‬‬


‫ﻳﺘﻢ إﺟﺮاء اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻃﺒﻘ ًﺎ ﻟﻠﺪواﺋﺮ‬ ‫أ‪.‬‬
‫اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وإرﺷﺎد اﻟﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻲ اﻟﻤﻠﺼﻖ ﻋﻠﻰ آﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ ‪.‬‬
‫ب‪ .‬ﻻﺗﻘﻢ ﺑﺈﺟﺮاء اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ ﻋﻨﺪ اﻟﻮﺿﻊ ‪. ON‬‬

‫ج‪ .‬ﻳﺘﻢ ﺗﻮﺻﻴﻞ اﻟﻄﺮف اﻷرﺿﻰ ﻗﺒﻞ أى ﺗﻮﺻﻴﻼت آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى ‪.‬‬
‫د‪ .‬ﻳﺘﻢ إﺟﺮاء اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ ﻗﺒﻞ اﻟﺘﻮﺻﻴﻞ إﻟﻰ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ‪.‬‬
‫ﻩ‪ .‬ﻳﺠﺐ اﻟﺘﺄآﺪ ﻣﻦ إﺟﺮاء اﻟﺘﻮﺻﻴﻞ إﻟﻰ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ﻣﻦ ﺧﻼل ﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﻳﻜﻮن أﻗﻞ ﺧﻠﻮص ﺑﻴﻦ ﻧﻘﻂ‬
‫ﺗﻮﺻﻴﻠﺔ ‪ ٣‬ﻣﻢ‪ .‬وﻳﻘﻮم هﺬا اﻟﻤﻔﺘﺎح ﺑﺎﻟﻔﺼﻞ اﻟﻜﻠﻰ ﻟﻸﻗﻄﺎب اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ‪.‬‬
‫و‪ .‬ﺗﺠﻨﺐ اﻟﺘﻮﺻﻴﻼت اﻟﻐﻴﺮ ﺟﻴﺪة )اﻟﻤﻬﺘﺰة – اﻟﻐﻴﺮ ﻣﺮﺑﻮﻃﺔ ﺟﻴﺪًا( ﻋﻠﻰ اﻟﺮوزﻳﺘﺎت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻟﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ‬
‫واﻟﺨﺎرﺟﻴﺔ وﻣﻔﺘﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ وذﻟﻚ ﻟﺘﻔﺎدى ﺣﺪوث اﻟﺘﺤﻤﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ ﻧﺘﻴﺠﺔ اﻧﺨﻔﺎض اﻟﻔﻮﻟﺖ واﻟﺬى‬
‫ﻳﺆدى إﻟﻰ ﺣﺪوث أﻋﻄﺎل آﻬﺮﺑﺎﺋﻴﺔ ‪.‬‬

‫‪٣٧‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫‪ ٣-١٨‬اﻟﺒﻴﺎﻧﺎت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪:‬‬
‫اﻻﺳﺘﻬﻼك اﻟﻜﻬﺮﺑﺎﺋﻰ‬
‫ﻣﻘﺎس‬ ‫ﺗﺪﻓﺌﺔ‬ ‫ﺗﺒﺮﻳﺪ‬ ‫ﻣﻮدﻳﻞ‬
‫ﻣﻔﺘﺎح‬ ‫ﻣﺼﺪر‬
‫اﻟﺴﻠﻚ‬ ‫اﻟﻨﻈﺎم‬
‫اﻟﺘﺸﻐﻴﻞ‬ ‫ﺑﺎﺳﺘﺨﺪام اﻟﺪورة‬ ‫اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ‬
‫)ﻣﻼﺣﻈﺔ‪(٢‬‬
‫‪º٤٦‬م‬ ‫‪º٤٣‬م‬ ‫‪º٣٥‬م‬ ‫اﻟﻤﻨﻔﺼﻞ‬
‫اﻟﻤﻌﻜﻮﺳﺔ‬
‫***‬ ‫**‬ ‫*‬
‫****‬
‫‪٢‬‬
‫ﻣﻢ‬ ‫أﻣﺒﻴﺮ‬ ‫وات‬ ‫أﻣﺒﻴﺮ‬ ‫وات‬ ‫أﻣﺒﻴﺮ‬ ‫وات‬ ‫أﻣﺒﻴﺮ‬ ‫وات‬ ‫أﻣﺒﻴﺮ‬ ‫ﻓﻮﻟﺖ‪/‬ﻓﺎز‪/‬هﺮﺗﺰ‬ ‫دورة ﻣﻌﻜﻮﺳﺔ‬

‫‪ ٦‬ﻣﻢ‪٢‬‬ ‫‪٤٠‬‬ ‫‪٣٨٣٣‬‬ ‫‪١٥‬‬ ‫‪٤٣٢٣ ١٩٫٤ ٤١١٨ ١٨٫٨ ٣٥٧١ ١٧٫١ ٥٠/١/٢٤٠-٢٢٠‬‬ ‫‪53QFJ36-708‬‬

‫‪ ٤‬ﻣﻢ‪٢‬‬ ‫‪٢٠‬‬ ‫‪٤٤٣٣‬‬ ‫‪٨٫٣‬‬ ‫‪٥٦٨٥ ١٠٫٢ ٥٣٧٠‬‬ ‫‪٩٫٦‬‬ ‫‪٤٥٢٦‬‬ ‫‪٧٫٩‬‬ ‫‪٥٠/٣/٤٢٠-٣٨٠‬‬ ‫‪53QFJ48-508‬‬

‫‪ ٤‬ﻣﻢ‪٢‬‬ ‫‪٢٠‬‬ ‫‪---‬‬ ‫‪---‬‬ ‫‪٦٩٨٥ ١١٫٤ ٦٦٥٥‬‬ ‫‪١١‬‬ ‫‪٥٧٧١‬‬ ‫‪١٠‬‬ ‫‪٥٠/٣/٤٢٠-٣٨٠ 53KFJT60-508‬‬

‫ﻣﻼﺣﻈﺎت‪:‬‬
‫‪ .١‬ﻓﺘﺮة ﺗﻴﺎر اﻟﺘﻘﻮﻳﻢ ﺗﻜﻮن ﻋﺎدة اﻗﻞ ﻣﻦ ‪ ١‬ﺛﺎﻧﻴﺔ‪.‬‬
‫‪ .٢‬ﻣﺴﺎﺣﺔ ﻣﻘﻄﻊ اﻟﺴﻠﻚ اﻟﻤﺒﻴﻨﺔ ﻓﻰ اﻟﺠﺪول ﺗﺴﺘﺨﺪم ﺣﺘﻰ ﻃﻮل ‪ ٢٥‬ﻣﺘﺮ ﺑﺎﻟﻨﺴﺒﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪53QFJ36‬‬
‫وﺣﺘﻰ ﻃﻮل ‪ ٣٠‬ﻣﺘﺮ ﺑﺎﻟﻨﺴﺒﺔ ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻼت ‪ 53QFJ48‬و ‪.53KFJT60‬‬
‫‪ .٣‬ﻇﺮوف اﻟﺘﺸﻐﻴﻞ‪.‬‬
‫اﻟﺴﺮﻋﺔ اﻟﻌﺎﻟﻴﺔ ﻟﻤﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫درﺟﺔ اﻟﺤﺮارة اﻟﺨﺎرﺟﻴﺔ ‪ º٣٥‬م ﺟﺎﻓﺔ‬ ‫درﺟﺔ اﻟﺤﺮارة اﻟﺪاﺧﻠﻴﺔ ‪º١٩/٢٧‬م ﺟﺎﻓﺔ‪/‬ﻣﺒﺘﻠﺔ‬ ‫*‬
‫اﻟﺴﺮﻋﺔ اﻟﻌﺎﻟﻴﺔ ﻟﻤﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫درﺟﺔ اﻟﺤﺮارة اﻟﺨﺎرﺟﻴﺔ ‪ º٤٣‬م ﺟﺎﻓﺔ‬ ‫** درﺟﺔ اﻟﺤﺮارة اﻟﺪاﺧﻠﻴﺔ ‪º١٩/٢٧‬م ﺟﺎﻓﺔ‪/‬ﻣﺒﺘﻠﺔ‬
‫اﻟﺴﺮﻋﺔ اﻟﻌﺎﻟﻴﺔ ﻟﻤﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫درﺟﺔ اﻟﺤﺮارة اﻟﺨﺎرﺟﻴﺔ ‪ º٤٦‬م ﺟﺎﻓﺔ‬ ‫*** درﺟﺔ اﻟﺤﺮارة اﻟﺪاﺧﻠﻴﺔ ‪º١٩/٢٧‬م ﺟﺎﻓﺔ‪/‬ﻣﺒﺘﻠﺔ‬
‫اﻟﺴﺮﻋﺔ اﻟﻌﺎﻟﻴﺔ ﻟﻤﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫درﺟﺔ اﻟﺤﺮارة اﻟﺨﺎرﺟﻴﺔ ‪º٦/٧‬م ﺟﺎﻓﺔ‪/‬ﻣﺒﺘﻠﺔ‬ ‫**** درﺟﺔ اﻟﺤﺮارة اﻟﺪاﺧﻠﻴﺔ ‪º٢٠‬م ﺟﺎﻓﺔ‬

‫‪ ٤-١٨‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ إﻟﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫ﻳﺘﻢ ﺗﻮﺻﻴﻞ أﻃﺮاف اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ إﻟﻰ أﻃﺮاف روزﻳﺘﺔ اﻟﻜﻬﺮﺑﺎء ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻃﺒﻘ ًﺎ ﻟﻠﺪاﺋﺮة اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وإرﺷﺎد اﻟﺘﻮﺻﻴﻞ‬
‫اﻟﻜﻬﺮﺑﺎﺋﻲ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ‪.‬‬

‫ﺗﺠﻨﺐ ﻋﺪم إﺣﻜﺎم ﺗﺜﺒﻴﺖ اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻓﻲ روزﻳﺘﺔ‬ ‫•‬


‫آﻬﺮﺑﺎء اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬ ‫ﺘﺤﺫﻴﺭ‬
‫ﺗﺠﻨﺐ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﻟﻠﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫•‬ ‫!‬
‫ﻋﻨﺪ ﺗﻮﺻﻴﻠﻬﺎ ﺑﺮوزﻳﺘﺔ آﻬﺮﺑﺎء اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬

‫‪ ٥-١٨‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬


‫ﻳﺘﻢ ﺗﻮﺻﻴﻞ أﻃﺮاف اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ إﻟﻰ أﻃﺮاف روزﻳﺘﺔ اﻟﻜﻬﺮﺑﺎء ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻃﺒﻘ ًﺎ ﻟﻠﺪاﺋﺮة اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وإرﺷﺎد اﻟﺘﻮﺻﻴﻞ‬
‫اﻟﻜﻬﺮﺑﺎﺋﻲ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ‪.‬‬
‫ﺘﺤﺫﻴﺭ‬
‫ﺗﺠﻨﺐ ﻋﺪم إﺣﻜﺎم ﺗﺜﺒﻴﺖ اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻓﻲ روزﻳﺘﺔ آﻬﺮﺑﺎء اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬ ‫•‬
‫ﺗﺠﻨﺐ اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﻟﻠﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻋﻨﺪ ﺗﻮﺻﻴﻠﻬﺎ ﺑﺮوزﻳﺘﺔ آﻬﺮﺑﺎء اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬ ‫•‬ ‫!‬

‫ﺍﻟﻭﺼﻠﺔ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﻷﺴﻼﻙ ﺍﻟﻜﻬﺭﺒﺎﺀ‬


‫ﺒﻴﻥ ﺍﻟﻭﺤﺩﺘﻴﻥ ﺍﻟﺨﺎﺭﺠﻴﺔ ﻭﺍﻟﺩﺍﺨﻠﻴﺔ‬
‫ﻓﻙ ﻏﻁﺎﺀ ﺍﻟﻜﻬﺭﺒﺎﺀ‬
‫ﻗﺒل ﺇﺠﺭﺍﺀ ﺍﻟﺘﻭﺼﻴﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ‬
‫ﺍﻟﻭﺼﻠﺔ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﻷﺴﻼﻙ‬
‫ﺍﻟﻜﻬﺭﺒﺎﺀ ﺍﻟﺭﺌﻴﺴﻴﺔ‬

‫‪٣٨‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫‪ ٦-١٨‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺒﺎت ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪53QFJ36-708‬‬

‫ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ‬ ‫ﺭﻭﺯﻴﺘﺎﺕ ﻜﻬﺭﺒﺎﺀ‬


‫ﻟﻠﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬ ‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬

‫ﺍﻟﻤﻔﺘﺎﺡ ﺍﻟﺭﺌﻴﺴﻲ‬

‫ﻤﻔﺘﺎﺡ ﺍﻟﺘﺸﻐﻴل‬
‫ﻤﺼﺩﺭ ﺍﻟﻜﻬﺭﺒﺎﺀ‬
‫‪٥٠/١/٢٢٠‬‬

‫ﺭﻭﺯﻴﺘﺎﺕ ﻜﻬﺭﺒﺎﺀ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬
‫اﻟﺮﻣﻮز‬
‫ﻃﺮف اﻻرﺿﻰ‬ ‫=‬
‫اﻟﻄﺮف اﻟﻤﺘﻌﺎدل ﻟﻤﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ) ‪( Neutral‬‬ ‫=‬ ‫‪N‬‬
‫اﻟﻄﺮف اﻟﺤﻲ ﻟﻠﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ )‪(Live‬‬ ‫=‬ ‫‪L‬‬
‫اﻟﻄﺮف اﻟﻤﺘﻌﺎدل ﻟﻠﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ )‪ (Neutral‬ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ اﻟﺨﺎرﺟﻴﺔ‪.‬‬ ‫=‬ ‫‪C‬‬
‫اﻟﻄﺮف اﻟﺤﻲ ﻟﻠﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ )‪ (Live‬ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‪.‬‬ ‫=‬ ‫‪R‬‬
‫ﻃﺮف اﻟﺘﺤﻜﻢ ﻓﻰ اﻟﻀﺎﻏﻂ‬ ‫=‬ ‫‪Y‬‬
‫ﻃﺮف اﻟﺘﺤﻜﻢ ﻓﻰ ﺻﻤﺎم ﻋﺎآﺲ اﻟﺪورة‬ ‫=‬ ‫‪O‬‬
‫ﻃﺮف اﻟﺘﺤﻜﻢ ﻓﻰ ﻣﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫=‬ ‫‪W2‬‬
‫ﺳﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮارى ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬ ‫=‬ ‫‪T3‬‬

‫ﻣﻼﺣﻈﺔ هﺎﻣﺔ‬
‫اﻟﻮﺻﻠﺔ اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺴﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮارى ﻟﻠﺘﺤﻜﻢ ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ واﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫• ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ آﻤﻠﺤﻖ ﺑﻄﻮل ‪ ٦‬ﻣﺘﺮ‬
‫• ﻳﺠﺐ ﺗﻮﺻﻴﻠﻬﺎ إﻟﻰ اﻟﻮﺣﺪة اﻹﻟﻜﺘﺮوﻧﻴﺔ ) ‪ ( PCB‬ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫آﻤﺎ ﻳﺠﺐ ﺗﻮﺻﻴﻠﻬﺎ إﻟﻰ اﻟﻮﺣﺪة اﻹﻟﻜﺘﺮوﻧﻴﺔ ) ‪ ( PCB‬ﻋﻨﺪ اﻟﻮﺻﻠﺔ ) ‪ ( CN1‬ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫• ﻓﻰ ﺣﺎﻟﺔ اﻹﺣﺘﻴﺎج إﻟﻰ وﺻﻠﺔ آﻬﺮﺑﺎﺋﻴﺔ ﺑﻄﻮل أآﺜﺮ ﻣﻦ ‪ ٦‬ﻣﺘﺮ ﻳﺘﻢ ﻃﻠﺐ ﺷﺮاء وﺻﻠﺔ آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى إﺿﺎﻓﻴﺔ ﻣﻦ ﻣﺮآﺰ ﺑﻴﻊ ﻗﻄﻊ اﻟﻐﻴﺎر‬
‫ﻣﻦ اﻟﻤﺼﻨﻊ وﻳﺘﻢ ﺗﺠﻤﻴﻊ اﻟﻮﺻﻠﺘﻴﻦ ﻣﻊ ﺑﻌﻀﻬﻤﺎ ﻓﻰ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ ﻗﺒﻞ ﺗﻮﺻﻴﻠﻬﻤﺎ ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‬

‫ﻣﻘﺎﺳﺎت اﻷﺳﻼك اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬


‫‪W2‬‬ ‫‪O‬‬ ‫‪Y‬‬ ‫‪R‬‬ ‫‪C‬‬ ‫‪L‬‬ ‫‪N‬‬
‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬
‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ٦‬ﻣﻢ‬ ‫‪ ٦‬ﻣﻢ‬

‫ﻣﻼﺣﻈﺎت‬
‫)‪ (١‬ﻳﺘﻢ اﺟﺮاء اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ أو ًﻻ ﻣﻦ ﻧﺎﺣﻴﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬
‫)‪ (٢‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻤﻮﺿﺤﺔ ﺑﺨﻄﻮط ﻣﻨﻘﻄﺔ ﻳﺘﻢ ﺗﻮﺻﻴﻠﻬﺎ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ‬
‫)‪ (٣‬ﻳﺘﻢ اﻹﺳﺘﻌﺎﻧﺔ ﺑﺎﻟﺪاﺋﺮة اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وإرﺷﺎدات اﻟﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ اﻟﻤﻠﺼﻘﺔ داﺧﻞ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫‪٣٩‬‬
‫ﺗﺎﺑﻊ ‪ -‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫‪ ٧-١٨‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺒﺎت ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪53QFJ48-508‬‬

‫ﺭﻭﺯﻴﺘﺎﺕ ﻜﻬﺭﺒﺎﺀ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬ ‫ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ‬
‫ﻟﻠﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬

‫ﺍﻟﻤﻔﺘﺎﺡ ﺍﻟﺭﺌﻴﺴﻲ‬

‫ﻤﺼﺩﺭ ﺍﻟﻜﻬﺭﺒﺎﺀ‬
‫‪٥٠/٣/٤٢٠-٣٨٠‬‬

‫ﻤﻔﺘﺎﺡ ﺍﻟﺘﺸﻐﻴل‬

‫ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ‬
‫ﺭﻭﺯﻴﺘﺎﺕ ﻜﻬﺭﺒﺎﺀ‬
‫ﻟﻠﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬

‫اﻟﺮﻣﻮز‬
‫= ﻃﺮف اﻻرﺿﻰ‬
‫‪= L1,L2,‬‬
‫اﻟﻄﺮف اﻟﺤﻲ ﻟﻤﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ )‪.(Live‬‬
‫‪L3‬‬
‫‪ = N‬اﻟﻄﺮف اﻟﻤﺘﻌﺎدل ﻟﻤﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ )‪.(Neutral‬‬
‫‪ = N1‬اﻟﻄﺮف اﻟﻤﺘﻌﺎدل ﻟﻠﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ )‪ (Neutral‬ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ اﻟﺨﺎرﺟﻴﺔ‪.‬‬
‫‪ = A1‬اﻟﻄﺮف اﻟﺤﻲ ﻟﻠﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ )‪ (Live‬ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‪.‬‬
‫‪ = 4‬ﻃﺮف ﺗﺤﻜﻢ‬
‫‪ = O‬ﻃﺮف ﺗﺤﻜﻢ ﻓﻰ ﺻﻤﺎم ﻋﺎآﺲ اﻟﺪورة‬
‫‪ = W2‬ﻃﺮف ﺗﺤﻜﻢ ﻓﻰ ﻣﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ = Y‬ﻃﺮف اﻟﺘﺤﻜﻢ ﻓﻰ اﻟﻀﺎﻏﻂ‬

‫ﻣﻼﺣﻈﺔ هﺎﻣﺔ‬
‫اﻟﻮﺻﻠﺔ اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺎﻟﺘﺤﻜﻢ ﺑﻴﻦ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ واﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫• ﻳﺘﻢ ﺗﻮرﻳﺪهﺎ ﻣﻦ اﻟﻤﺼﻨﻊ آﻤﻠﺤﻖ ﺑﻄﻮل ‪ ٦‬ﻣﺘﺮ‬
‫• ﻳﺠﺐ ﺗﻮﺻﻴﻠﻬﺎ إﻟﻰ اﻟﻮﺣﺪة اﻹﻟﻜﺘﺮوﻧﻴﺔ ) ‪ ( PCB‬ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫آﻤﺎ ﻳﺠﺐ ﺗﻮﺻﻴﻠﻬﺎ إﻟﻰ اﻟﻮﺣﺪة اﻹﻟﻜﺘﺮوﻧﻴﺔ ) ‪ ( PCB‬ﻋﻨﺪ اﻟﻮﺻﻠﺔ ) ‪ ( CN305‬ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫• ﻓﻰ ﺣﺎﻟﺔ اﻹﺣﺘﻴﺎج إﻟﻰ وﺻﻠﺔ آﻬﺮﺑﺎﺋﻴﺔ ﺑﻄﻮل أآﺜﺮ ﻣﻦ ‪ ٦‬ﻣﺘﺮ ﻳﺘﻢ ﻃﻠﺐ ﺷﺮاء وﺻﻠﺔ آﻬﺮﺑﺎﺋﻴﺔ أﺧﺮى إﺿﺎﻓﻴﺔ ﻣﻦ ﻣﺮآﺰ ﺑﻴﻊ ﻗﻄﻊ اﻟﻐﻴﺎر‬
‫ﻣﻦ اﻟﻤﺼﻨﻊ وﻳﺘﻢ ﺗﺠﻤﻴﻊ اﻟﻮﺻﻠﺘﻴﻦ ﻣﻊ ﺑﻌﻀﻬﻤﺎ ﻓﻰ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ ﻗﺒﻞ ﺗﻮﺻﻴﻠﻬﻤﺎ ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‬

‫ﻣﻘﺎﺳﺎت اﻷﺳﻼك اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬


‫‪Y‬‬ ‫‪W2‬‬ ‫‪O‬‬ ‫‪4‬‬ ‫‪A1-L‬‬ ‫‪N1-N‬‬ ‫‪N‬‬ ‫‪L1‬‬ ‫‪L2‬‬ ‫‪L3‬‬
‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬
‫‪ ٦‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ٦‬ﻣﻢ‬ ‫‪ ٤‬ﻣﻢ‬ ‫‪ ٤‬ﻣﻢ‬ ‫‪ ٤‬ﻣﻢ‬

‫ﻣﻼﺣﻈﺎت‬
‫)‪ (١‬ﻳﺘﻢ اﺟﺮاء اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ أو ًﻻ ﻣﻦ ﻧﺎﺣﻴﺔ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‪.‬‬
‫)‪ (٢‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ اﻟﻤﻮﺿﺤﺔ ﺑﺨﻄﻮط ﻣﻨﻘﻄﺔ ﻳﺘﻢ ﺗﻮﺻﻴﻠﻬﺎ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺐ‬
‫)‪ (٣‬ﻳﺘﻢ اﻹﺳﺘﻌﺎﻧﺔ ﺑﺎﻟﺪاﺋﺮة اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وإرﺷﺎدات اﻟﺘﻮﺻﻴﻞ اﻟﻜﻬﺮﺑﺎﺋﻰ اﻟﻤﻠﺼﻘﺔ داﺧﻞ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺨﺎرﺟﻴﺔ واﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫‪٤٠‬‬
‫ﺘﺎﺒﻊ ‪ -‬ﺍﻟﺘﻭﺼﻴﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ‬
‫‪ ٨-١٨‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻓﻲ ﻣﻮﻗﻊ اﻟﺘﺮآﻴﺒﺎت ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪53KFJT60-508‬‬

‫ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ‬
‫ﻟﻠﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬
‫ﺭﻭﺯﻴﺘﺎﺕ ﻜﻬﺭﺒﺎﺀ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬

‫ﻤﺼﺩﺭ ﺍﻟﻜﻬﺭﺒﺎﺀ‬
‫‪٥٠/٣/٣٨٠‬‬
‫ﻤﻼﺤﻅﺔ ﻫﺎﻤﺔ‬

‫ﺭﻭﺯﻴﺘﺎﺕ ﻜﻬﺭﺒﺎﺀ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬
‫ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ‬
‫ﻟﻠﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬

‫ﺍﻟﺭﻤﻭﺯ‬

‫= ﻁﺭﻑ ﺍﻻﺭﻀﻰ‬
‫‪ = L1,L2, L3‬ﺍﻟﻁﺭﻑ ﺍﻟﺤﻲ ﻟﻤﺼﺩﺭ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺭﺒﺎﺌﻰ )‪.(Live‬‬
‫‪ = N‬ﺍﻟﻁﺭﻑ ﺍﻟﻤﺘﻌﺎﺩل ﻟﻤﺼﺩﺭ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺭﺒﺎﺌﻰ )‪.(Neutral‬‬
‫‪ = A1‬ﺍﻟﻁﺭﻑ ﺍﻟﺤﻲ ﻟﻠﺘﻭﺼﻴل ﺍﻟﻜﻬﺭﺒﺎﺌﻰ )‪ (Live‬ﺒﻴﻥ ﺍﻟﻭﺤﺩﺘﻴﻥ ﺍﻟﺩﺍﺨﻠﻴﺔ ﻭﺍﻟﺨﺎﺭﺠﻴﺔ‪.‬‬
‫‪ = N1‬ﺍﻟﻁﺭﻑ ﺍﻟﻤﺘﻌﺎﺩل ﻟﻠﺘﻭﺼﻴل ﺍﻟﻜﻬﺭﺒﺎﺌﻰ )‪ (Neutral‬ﺒﻴﻥ ﺍﻟﻭﺤﺩﺘﻴﻥ ﺍﻟﺩﺍﺨﻠﻴﺔ ﺍﻟﺨﺎﺭﺠﻴﺔ‪.‬‬
‫‪ = 1‬ﻁﺭﻑ ﺍﻟﺘﻭﺼﻴل ﺍﻟﻜﻬﺭﺒﺎﺌﻰ ﺇﻟﻰ ﺍﻟﻀﺎﻏﻁ‪.‬‬
‫‪ = 4‬ﻁﺭﻑ ﺘﺤﻜﻡ‬
‫➀ = ﺍﻟﻤﻔﺘﺎﺡ ﺍﻟﺭﺌﻴﺴﻲ‬
‫➁ = ﻤﻔﺘﺎﺡ ﺍﻟﺘﺸﻐﻴل‬
‫ﻤﻼﺤﻅﺔ ﻫﺎﻤﺔ‬
‫ﺍﻟﻭﺼﻠﺔ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﻟﻠﺘﺤﻜﻡ ﺒﻴﻥ ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ ﻭﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ ‪:‬‬
‫ﻴﺘﻡ ﺘﻭﺭﻴﺩﻫﺎ ﻤﻥ ﺍﻟﻤﺼﻨﻊ ﻜﻤﻠﺤﻕ ﺒﻁﻭل ‪ ٦‬ﻤﺘﺭ‬ ‫•‬
‫ﻴﺠﺏ ﺘﻭﺼﻴﻠﻬﺎ ﺇﻟﻰ ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ ) ‪ ( PCB‬ﻋﻨﺩ ﺍﻟﻭﺼﻠﺔ ‪ CN305‬ﺒﺎﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬ ‫•‬
‫ﻜﻤﺎ ﻴﺠﺏ ﺘﻭﺼﻴﻠﻬﺎ ﺇﻟﻰ ﺍﻟﻭﺤﺩﺓ ﺍﻹﻟﻜﺘﺭﻭﻨﻴﺔ ) ‪ ( PCB‬ﻋﻨﺩ ﺍﻟﻭﺼﻠﺔ ‪ CN120‬ﺒﺎﻟﻭﺤﺩﺓ ﺍﻟﺩﺍﺨﻠﻴﺔ‬
‫ﻓﻰ ﺤﺎﻟﺔ ﺍﻹﺤﺘﻴﺎﺝ ﺇﻟﻰ ﻭﺼﻠﺔ ﻜﻬﺭﺒﺎﺌﻴﺔ ﺒﻁﻭل ﺃﻜﺜﺭ ﻤﻥ ‪ ٦‬ﻤﺘﺭ ﻴﺘﻡ ﻁﻠﺏ ﺸﺭﺍﺀ ﻭﺼﻠﺔ ﻜﻬﺭﺒﺎﺌﻴﺔ ﺃﺨﺭﻯ ﺇﻀﺎﻓﻴﺔ ﻤﻥ ﻤﺭﻜﺯ ﺒﻴﻊ ﻗﻁﻊ‬ ‫•‬
‫ﺍﻟﻐﻴﺎﺭ ﻤﻥ ﺍﻟﻤﺼﻨﻊ ﻭﻴﺘﻡ ﺘﺠﻤﻴﻊ ﺍﻟﻭﺼﻠﺘﻴﻥ ﻤﻊ ﺒﻌﻀﻬﻤﺎ ﻓﻰ ﻤﻭﻗﻊ ﺍﻟﺘﺭﻜﻴﺏ ﻗﺒل ﺘﻭﺼﻴﻠﻬﻤﺎ ﺒﻜل ﻤﻥ ﺍﻟﻭﺤﺩﺘﻴﻥ ﺍﻟﺨﺎﺭﺠﻴﺔ ﻭﺍﻟﺩﺍﺨﻠﻴﺔ‪.‬‬

‫ﻣﻘﺎﺳﺎت اﻷﺳﻼك اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬


‫‪1-1‬‬ ‫‪4-4‬‬ ‫‪N1-N A1-A‬‬ ‫‪N‬‬ ‫‪L1‬‬ ‫‪L2‬‬ ‫‪L3‬‬
‫‪٢‬‬ ‫‪٢‬‬ ‫‪٢‬‬
‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‬ ‫‪ ١‬ﻣﻢ‪ ١ ٢‬ﻣﻢ‬ ‫‪٢‬‬
‫‪ ٦‬ﻣﻢ‬ ‫‪٢‬‬
‫‪ ٤‬ﻣﻢ‬ ‫‪٢‬‬
‫‪ ٤‬ﻣﻢ‬ ‫‪٢‬‬
‫‪ ٤‬ﻣﻢ‬

‫ﻤﻼﺤﻅﺎﺕ )‪ (١‬ﻴﺘﻡ ﺍﺠﺭﺍﺀ ﺍﻟﺘﻭﺼﻴﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﺃﻭ ﹰﻻ ﻤﻥ ﻨﺎﺤﻴﺔ ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‪.‬‬


‫)‪ (٢‬ﺍﻟﺘﻭﺼﻴﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﺍﻟﻤﻭﻀﺤﺔ ﺒﺨﻁﻭﻁ ﻤﻨﻘﻁﺔ ﻴﺘﻡ ﺘﻭﺼﻴﻠﻬﺎ ﻓﻲ ﻤﻭﻗﻊ ﺍﻟﺘﺭﻜﻴﺏ‬
‫)‪ (٣‬ﻴﺘﻡ ﺍﻹﺴﺘﻌﺎﻨﺔ ﺒﺎﻟﺩﺍﺌﺭﺓ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ ﻭﺇﺭﺸﺎﺩﺍﺕ ﺍﻟﺘﻭﺼﻴل ﺍﻟﻜﻬﺭﺒﺎﺌﻰ ﺍﻟﻤﻠﺼﻘﺔ ﺩﺍﺨل ﺍﻟﻭﺤﺩﺘﻴﻥ ﺍﻟﺨﺎﺭﺠﻴﺔ ﻭﺍﻟﺩﺍﺨﻠﻴﺔ‪.‬‬
‫‪٤١‬‬
‫‪ .١٩‬إﻧﻬﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬

‫)‪ (١‬ﺗﺮآﻴﺐ ﻏﻄﺎء ﻋﻠﺒﺔ آﻬﺮﺑﺎء اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬


‫* ﻗﻢ ﺑﺘﺮآﻴﺐ ﻏﻄﺎء ﻋﻠﺒﺔ اﻟﻜﻬﺮﺑﺎء ﻓﻰ ﻣﻮﺿﻌﻪ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﺑﺈﺳﺘﺨﺪام ﻣﺴﺎﻣﻴﺮ اﻟﺘﺜﺒﻴﺖ‬

‫ﻏﻁﺎﺀ ﻋﻠﺒﺔ‬
‫ﺍﻟﻜﻬﺭﺒﺎﺀ‬

‫)‪ (٢‬ﺗﺮآﻴﺐ ﺟﺮﻳﻠﺔ راﺟﻊ اﻟﻬﻮاء‬


‫* ﻗﻢ ﺑﺘﺮآﻴﺐ اﻟﻮاﺟﻬﺔ اﻷﻣﺎﻣﻴﺔ ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﺑﻮاﺳﻄﺔ اﻟﻤﻘﺒﻀﻴﻦ آﻤﺎ هﻮ ﻣﻮﺿﺢ ﺑﺎﻟﺸﻜﻞ ‪.‬‬

‫ﺍﻟﻭﺍﺠﻬﺔ ﺍﻷﻤﺎﻤﻴﺔ‬

‫)‪ (٣‬ﻳﺠﺐ رﺑﺎط اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﻊ وﺻﻼت اﻟﻔﺮﻳﻮن وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﺑﺸﻜﻞ ﺣﺰﻣﻪ ﺗﻐﻄﻰ ﺑﻐﻄﺎء ﻳﺘﻢ ﺗﻌﻠﻴﻘﻪ ﻓﻰ‬
‫اﻟﻤﻜﺎن اﻟﻤﻨﺎﺳﺐ ﺑﻮاﺳﻄﺔ ﺣﺎﻣﻞ‪.‬‬
‫ﺣﺰﻣﺔ اﻟﻮﺻﻼت واﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﻋﻠﻰ اﻷﺧﺺ اﻟﺠﺰء ﻣﻨﻬﺎ اﻟﺬى ﻳﻤﺮ ﺧﻼل ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ ﻳﺠﺐ أن ﻳﻜﻮن ﻣﺴﺘﺪﻳﺮ اﻟﺸﻜﻞ ﺑﻘﺪر‬
‫اﻹﻣﻜﺎن‪.‬‬
‫ﻳﺠﺐ أن ﻳﻜﻮن ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ أﺳﻔﻞ وﺻﻼت اﻟﻔﺮﻳﻮن وذﻟﻚ ﻟﻀﻤﺎن ﺳﻬﻮﻟﺔ ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‪.‬‬

‫ﻤﻭﺍﺴﻴﺭ‬
‫ﺍﻟﻔﺭﻴﻭﻥ‬ ‫ﺍﻟﻭﺼﻼﺕ‬
‫ﺍﻟﻤﻌﺯﻭﻟﺔ‬ ‫ﺸﺭﻴﻁ ﻻﺼﻕ‬

‫ﺍﻟﻜﺎﺒﻼﺕ ﺍﻟﻜﻬﺭﺒﺎﺌﻴﺔ‬
‫ﺨﺭﻁﻭﻡ ﺘﺼﺭﻴﻑ‬
‫ﻤﻴﺎﻩ ﺍﻟﺘﻜﺜﻴﻑ‬
‫ﺤﻭﺍﻤل‬

‫‪٤٢‬‬
‫)‪ (٤‬ﻳﺠﺐ ﺗﻐﻄﻴﺔ اﻟﺨﻠﻮص اﻟﻤﻮﺟﻮد ﺑﻴﻦ اﻟﺤﺰﻣﺔ وﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ ﺑﺎﺳﺘﺨﺪام ﺟﻠﺒﺔ ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ وﻏﻄﺎء ﻟﻠﺠﻠﺒﺔ وﻣﻌﺠﻮن ﻣﺎﻧﻊ اﻟﺘﺴﺮب وﻓﻰ‬
‫ﺣﺎﻟﺔ إهﻤﺎل إﺟﺮاء ذﻟﻚ ﻓﺈن اﻟﻬﻮاء اﻟﺠﻮى ﻳﺘﺴﺮب داﺧﻞ اﻟﻐﺮﻓﺔ اﻟﻤﺮاد ﺗﻜﻴﻴﻔﻬﺎ‪.‬‬

‫‪٤٣‬‬
‫‪ – ٢٠‬اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ﺑﻌﺪ اﻧﺘﻬﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬
‫‪ ١-٢٠‬ﻣﻼﺣﻈﺎت‪:‬‬
‫)‪ (١‬ﻻ ﻳﺘﻢ إﺟﺮاء اﻻﺧﺘﺒﺎر إﻻ ﺑﻌﺪ إﻧﻬﺎء أﻋﻤﺎل ﺗﻮﺻﻴﻼت وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن وﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ وإﺗﻤﺎم‬
‫اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪.‬‬
‫)‪ (٢‬ﻻ ﻳﺘﻢ إﺟﺮاء اﻻﺧﺘﺒﺎر إﻻ ﺑﻌﺪ اﻟﺘﺄآﺪ ﻣﻦ ﺗﺮآﻴﺐ ﻓﻼﺗﺮ اﻟﻬﻮاء واﻟﻮاﺟﻬﺔ اﻷﻣﺎﻣﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬

‫‪ ٢-٢٠‬ﺧﻄﻮات اﺧﺘﺒﺎر ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺒﺮﻳﺪ‬


‫ﻟﻠﺘﺄآﺪ ﻣﻦ ﺿﺒﻂ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن وأﻳﻀ ًﺎ ﻗﻴﺎس اﻷﻣﺒﻴﺮ اﻟﻜﻠﻰ‬
‫ﺘﻔﺎﺼﻴل‬ ‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬
‫أ ‪ -‬ﺣﺮك ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ إﻟﻰ وﺿﻊ اﻟﺘﺸﻐﻴﻞ )‪.(ON‬‬
‫ب ‪ -‬ﻗﻢ ﺑﺘﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺒﺮﻳﺪ ﺑﺎﺳﺘﺨﺪام وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬
‫ج ‪ -‬ﻗﻢ ﺑﻘﻴﺎس اﻟﻀﻐﻂ اﻟﻤﻨﺨﻔﺾ ﻟﻠﺘﺄآﺪ ﻣﻦ ﺿﺒﻂ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن‬
‫وأﻳﻀ ًﺎ ﻗﻢ ﺑﻘﻴﺎس اﻷﻣﺒﻴﺮ اﻟﻜﻠﻰ‪.‬‬
‫)‪(١‬‬

‫)‪ (١‬ﻗﻴﺎﺱ ﺍﻟﻀﻐﻁ ﺍﻟﻤﻨﺨﻔﺽ‬

‫‪53KFJT60‬‬ ‫‪53QFJ48‬‬ ‫‪53QFJ36‬‬ ‫ﻣﻮدﻳﻞ اﻟﺠﻬﺎز‬


‫‪٣٥‬‬ ‫‪٣٥‬‬ ‫‪٣٥‬‬ ‫درﺟﺔ ﺣﺮارة اﻟﺠﻮ اﻟﺨﺎرﺟﻲ م‪º‬‬
‫‪٦٢٫٧‬‬ ‫‪٦٠‬‬ ‫‪٧٣٫٦‬‬ ‫اﻟﻀﻐﻂ اﻟﻤﻨﺨﻔﺾ رﻃﻞ ﻋﻠﻰ اﻟﺒﻮﺻﺔ اﻟﻤﺮﺑﻌﺔ‬
‫‪١٠‬‬ ‫‪٧٫٩‬‬ ‫‪١٧٫١‬‬ ‫اﻷﻣﺒﻴﺮ اﻟﻜﻠﻰ‬
‫)‪ (١‬اﻟﻘﺮاءات ﻋﻨﺪ ﻓﻮﻟﺖ ‪ ٢٢٠‬ﻓﻮﻟﺖ ودرﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺮاﺟﻊ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ‪ ٢٧‬درﺟﺔ ﻣﺌﻮﻳﺔ ) ﻟﻠﺠﻬﺎز ‪( 36‬‬
‫)‪ (٢‬اﻟﻘﺮاءات ﻋﻨﺪ ﻓﻮﻟﺖ ‪ ٣٨٠‬ﻓﻮﻟﺖ ودرﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺮاﺟﻊ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ‪ ٢٧‬درﺟﺔ ﻣﺌﻮﻳﺔ ) ﻟﻠﺠﻬﺎز ‪( 60-48‬‬
‫)‪ (٣‬اﻟﻘﺮاءات ﻋﻨﺪ اﻟﺴﺮﻋﺔ اﻟﻌﺎﻟﻴﺔ ﻟﻤﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪ ٣-٢٠‬ﺧﻄﻮات اﺧﺘﺒﺎر ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺪﻓﺌﺔ‬


‫ﺘﻔﺎﺼﻴل‬ ‫ﺍﻟﻭﺤﺩﺓ ﺍﻟﺨﺎﺭﺠﻴﺔ‬ ‫ﻟﻠﺘﺄآﺪ ﻣﻦ ﺿﺒﻂ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن وأﻳﻀ ًﺎ ﻗﻴﺎس اﻷﻣﺒﻴﺮ اﻟﻜﻠﻰ‬

‫أ ‪ -‬ﺣﺮك ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ إﻟﻰ وﺿﻊ اﻟﺘﺸﻐﻴﻞ )‪.(ON‬‬


‫ب‪ -‬ﻗﻢ ﺑﺘﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺪﻓﺌﺔ ﺑﺎﺳﺘﺨﺪام وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬
‫ج‪ -‬ﻗﻢ ﺑﻘﻴﺎس اﻟﻀﻐﻂ اﻟﻌﺎﻟﻰ ﻟﻠﺘﺄآﺪ ﻣﻦ ﺿﺒﻂ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن‬
‫وأﻳﻀ ًﺎ ﻗﻢ ﺑﻘﻴﺎس اﻷﻣﺒﻴﺮ اﻟﻜﻠﻰ‪.‬‬
‫)‪(١‬‬

‫)‪ (١‬ﻗﻴﺎﺱ ﺍﻟﻀﻐﻁ ﺍﻟﻌﺎﻟﻰ‬

‫‪53QFJ48‬‬ ‫‪53QFJ36‬‬ ‫ﻣﻮدﻳﻞ اﻟﺠﻬﺎز‬


‫‪٧‬‬ ‫‪٧‬‬ ‫درﺟﺔ ﺣﺮارة اﻟﺠﻮ اﻟﺨﺎرﺟﻲ م‪º‬‬
‫‪٢٨٤‬‬ ‫‪٢٠٨‬‬ ‫اﻟﻀﻐﻂ اﻟﻌﺎﻟﻲ رﻃﻞ ﻋﻠﻰ اﻟﺒﻮﺻﺔ اﻟﻤﺮﺑﻌﺔ‬
‫‪٨٫٣‬‬ ‫‪١٥‬‬ ‫اﻷﻣﺒﻴﺮ اﻟﻜﻠﻰ‬
‫)‪ (١‬اﻟﻘﺮاءات ﻋﻨﺪ ﻓﻮﻟﺖ ‪ ٢٢٠‬ﻓﻮﻟﺖ ودرﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺮاﺟﻊ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ‪ ٢٠‬درﺟﺔ ﻣﺌﻮﻳﺔ ) ﻟﻠﺠﻬﺎز ‪( 36‬‬
‫)‪ (٢‬اﻟﻘﺮاءات ﻋﻨﺪ ﻓﻮﻟﺖ ‪ ٣٨٠‬ﻓﻮﻟﺖ ودرﺟﺔ ﺣﺮارة اﻟﻬﻮاء اﻟﺮاﺟﻊ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ‪ ٢٠‬درﺟﺔ ﻣﺌﻮﻳﺔ ) ﻟﻠﺠﻬﺎز ‪( 48‬‬
‫)‪ (٣‬اﻟﻘﺮاءات ﻋﻨﺪ اﻟﺴﺮﻋﺔ اﻟﻌﺎﻟﻴﺔ ﻟﻤﻮﺗﻮر اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬

‫‪٤٤‬‬
‫ﺗﺎﺑﻊ – اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ﺑﻌﺪ اﻧﺘﻬﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬

‫‪ ٤-٢٠‬وﻇﻴﻔﺔ اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ﺑﻌﺪ اﺗﻤﺎم ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬


‫• ﻳﻤﻜﻨﻚ أﻳﻀ ًﺎ اﺳﺘﺨﺪام وﻇﻴﻔﺔ اﺧﺘﺒﺎر ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻟﻤﺪة ﺳﺎﻋﺔ‪.‬‬
‫• ﻹﺳﺘﺨﺪام وﻇﻴﻔﺔ اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ‬
‫)‪ (١‬اﺿﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎح ‪ TEST RUNNING‬اﻟﻤﻮﺟﻮد ﻋﻠﻰ ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫وﻋﻨﺪﺋﺬ ﻳﻈﻬﺮ اﻟﺮﻣﺰ ‪ TEST RUN‬ﻋﻠﻰ ﺷﺎﺷﺔ ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ‪.‬‬

‫ﺗﺸﻐﻴﻞ ‪:‬‬
‫‪ .١‬اﺿﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎح اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ‪TEST RUNNING‬‬
‫اﻟﻤﻮﺟﻮد ﻋﻠﻰ ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫ﻋﻨﺪﺋﺬ ﺗﻌﻤﻞ وﻇﻴﻔﺔ اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ﻟﻤﺪة ‪ ٣٠‬دﻗﻴﻘﺔ ﺑﻐﺾ اﻟﻨﻈﺮ‬
‫ﻋﻦ درﺟﺔ اﻟﺤﺮارة اﻟﻤﻀﺒﻮﻃﺔ وﻋﻨﺪﺋﺬ ﺗﺄآﺪ ﻣﻦ أن ﺟﻤﻴﻊ‬
‫رﻣﻮز وﻇﻴﻔﺔ‬
‫اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ‬ ‫وﻇﺎﺋﻒ اﻟﺘﺸﻐﻴﻞ ﺗﻌﻤﻞ ﺑﺼﻮرة ﺟﻴﺪة‪.‬‬
‫‪( ADJUST‬‬ ‫‪ ( ADJUST‬أو )‬ ‫‪ .٢‬اﺿﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎح اﻟﻀﺒﻂ )‬
‫‪١‬‬
‫اﻟﻤﻮﺟﻮد ﻋﻠﻰ ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪:‬‬
‫ƒ ﻟﻔﺤﺺ درﺟﺎت اﻟﺤﺮارة ‪ T4 ، T3 ، T2 ، T1‬ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪٣٦‬‬
‫ƒ ﻟﻔﺤﺺ درﺟﺎت اﻟﺤﺮارة ‪ T3 ، T2 ، T1‬ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪٤٨‬‬
‫ﺣﻴﺚ ‪ = T1‬درﺟﺔ ﺣﺮارة اﻟﻐﺮﻓﺔ اﻟﻤﻜﻴﻔﺔ‬
‫‪ = T2‬درﺟﺔ ﺣﺮارة ﺳﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫‪ = T3‬درﺟﺔ ﺣﺮارة ﺳﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫‪ = T4‬درﺟﺔ ﺣﺮارة ﺳﻴﻨﺴﻮر اﻟﻬﻮاء اﻟﺪاﺧﻞ إﻟﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬

‫إﻳﻘﺎف اﻟﺘﺸﻐﻴﻞ ‪:‬‬


‫ﺑﻌﺪ إﺗﻤﺎم اﺧﺘﺒﺎر ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ‪ ،‬أﺿﻐﻂ ﻣﺮة ﺛﺎﻧﻴﺔ ﻋﻠﻰ ﻣﻔﺘﺎح اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ‪TEST RUNNING‬‬

‫‪٤٥‬‬
‫‪ -٢١‬ﻗﺎﺋﻤﺔ ﻓﺤﻮﺻﺎت اﻟﺘﺮآﻴﺒﺎت‬

‫‪ ١-٢١‬اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻣﻨﺎﺳﺐ‬ ‫)أ(‬
‫ﺗﻢ ﺗﺜﺒﻴﺖ ﺣﺎﻣﻞ اﻟﺘﺮآﻴﺐ ﻣﺴﺘﻮﻳ ًﺎ ﻋﻠﻰ اﻟﺤﺎﺋﻂ ﻓﻰ اﻻﺗﺠﺎهﻴﻦ اﻷﻓﻘﻰ واﻟﺮأﺳﻰ ﺑﺎﺳﺘﺨﺪام ﺟﻤﻴﻊ اﻟﻤﺴﺎﻣﻴﺮ‬
‫)ب(‬
‫اﻟﻤﺮﻓﻘﺔ ﻣﻊ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫ﺣﺎﻣﻞ اﻟﺘﺮآﻴﺐ ﻣﻠﺘﺼﻖ ﺗﻤﺎﻣ ًﺎ ﺑﺎﻟﺤﺎﺋﻂ ﺑﻌﺪ ﺗﺜﺒﻴﺘﻪ وﻻﻳﻤﻜﻦ ﺗﺤﺮﻳﻜﻪ‬ ‫)ج(‬
‫ﺗﻢ ﺗﺮآﻴﺐ ﺟﺮﻳﻠﺔ راﺟﻊ اﻟﻬﻮاء ﺟﻴﺪًا ﻋﻠﻰ اﻟﻮﺣﺪة‬ ‫)د(‬
‫)هـ( ﻓﻼﺗﺮ اﻟﻬﻮاء ﺗﻢ ﺗﺮآﻴﺒﻪ ﺟﻴﺪًا داﺧﻞ ﺟﺮﻳﻠﺔ راﺟﻊ اﻟﻬﻮاء‬
‫اﻟﻜﺎﺑﻴﻨﺔ ﻣﺜﺒﺘﺔ ﺟﻴﺪًا ﻋﻠﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬ ‫)و(‬

‫‪ ٢-٢١‬اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﻣﻜﺎن اﻟﺘﺮآﻴﺐ ﻣﻨﺎﺳﺐ‬ ‫)أ(‬
‫ﺗﻢ ﺗﺜﺒﻴﺖ اﻟﺘﺤﻤﻴﻠﺔ اﻟﺤﺎﺋﻄﻴﺔ ﻣﺴﺘﻮﻳﺔ ﻋﻠﻰ اﻟﺤﺎﺋﻂ ﻓﻰ اﻻﺗﺠﺎهﻴﻦ اﻷﻓﻘﻰ واﻟﺮأﺳﻰ‬
‫)ب(‬
‫)ﻓﻰ ﺣﺎﻟﺔ اﻟﺘﺮآﻴﺐ اﻟﺤﺎﺋﻄﻰ(‬
‫ﺗﻢ ﺗﺮآﻴﺐ اﻟﻮﺣﺪة ﺟﻴﺪًا ﻋﻠﻰ اﻟﺘﺤﻤﻴﻠﺔ اﻷرﺿﻴﺔ‬ ‫)ج(‬
‫ﺗﻢ ﺗﺮآﻴﺐ وﺗﺜﺒﻴﺖ ﺑﺎب اﻟﺨﺪﻣﺔ اﻟﺒﻼﺳﺘﻴﻚ‬ ‫)د(‬

‫‪ ٣-٢١‬ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬


‫وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﻣﺘﻮاﻓﻘﺔ ﻣﻊ ﻣﻮدﻳﻞ اﻟﻮﺣﺪة وذﻟﻚ ﺑﺎﻟﻨﺴﺒﺔ ﻷﻗﻄﺎر اﻟﻤﻮاﺳﻴﺮ وﻃﻮﻟﻬﺎ واﻟﻘﻄﺮ‬
‫)أ(‬
‫اﻟﺪاﺧﻠﻰ ﻟﻠﻌﺎزل وﺳﻤﻜﻪ‬
‫ﺗﻢ وﺿﻊ ﻋﺎزل ﻋﻠﻰ ﺻﻮاﻣﻴﻞ اﻟﻔﻠﻴﺮ واﻟﻬﺎف ﻳﻮﻧﻴﻮن ﺑﻌﺪ ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫)ب(‬
‫ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‬
‫ﺗﻢ إﺟﺮاء ﻋﻤﻠﻴﺔ ﻃﺮد اﻟﻬﻮاء واﻟﺮﻃﻮﺑﺔ ﺟﻴﺪًا‬ ‫)ج(‬
‫ﺗﻢ اﺧﺘﺒﺎر ﺗﻨﻔﻴﺲ اﻟﻔﺮﻳﻮن ﺑﻌﺪ ﺗﻮﺻﻴﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن ﺑﻜﻞ ﻣﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ‬ ‫)د(‬
‫)هـ( ﺗﻢ ﻓﺘﺢ اﻟﻤﺤﺎﺑﺲ اﻟﻔﻠﻴﺮ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻐﺎز واﻟﺴﺎﺋﻞ ﺟﻴﺪًا واﻟﻤﻮﺟﻮدة ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫ﺗﻢ إﻋﺎدة ﺗﺮآﻴﺐ أﻏﻄﻴﺔ اﻟﻤﺤﺎﺑﺲ اﻟﻔﻠﻴﺮ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻐﺎز واﻟﺴﺎﺋﻞ‬ ‫)و(‬

‫‪ ٤-٢١‬ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬


‫ﺗﻢ ﻣﺮاﻋﺎة ﻣﻴﻞ ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﺗﺪرﻳﺠﻴ ًﺎ إﻟﻰ أﺳﻔﻞ ﻓﻰ اﺗﺠﺎﻩ ﻣﺨﺮج اﻟﺘﺼﺮﻳﻒ‬
‫إﻟﻰ اﻟﺨﺎرج‬
‫‪ ٥-٢١‬اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫ﻓﻮﻟﺖ ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻓﻲ ﺣﺪود اﻟﻘﻴﻢ اﻟﻤﺴﻤﻮح ﺑﻬﺎ واﻟﻤﺪوﻧﺔ ﺑﻠﻮﺣﺔ ﺑﻴﺎﻧﺎت اﻟﺠﻬﺎز‬ ‫)أ(‬
‫)ب( ﻣﻘﺎﺳﺎت اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﻼﺋﻤﺔ ﻟﻤﻮدﻳﻞ اﻟﺠﻬﺎز‬
‫ﻣﻘﺎس ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ ﻣﻼﺋﻢ ﻟﻤﻮدﻳﻞ اﻟﺠﻬﺎز‬ ‫)ج(‬
‫اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻴﻦ اﻟﻮﺣﺪﺗﻴﻦ اﻟﺪاﺧﻠﻴﺔ واﻟﺨﺎرﺟﻴﺔ وﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ ﻣﻄﺎﺑﻘ ًﺔ ﻹرﺷﺎد اﻟﺘﻮﺻﻴﻞ‬
‫)د(‬
‫اﻟﻜﻬﺮﺑﺎﺋﻲ اﻟﻤﻠﺼﻖ داﺧﻞ اﻟﻮﺣﺪﺗﻴﻦ‬
‫)هـ( اﻟﺘﻮﺻﻴﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﺜﺒﺘﺔ ﺟﻴﺪًا وﻣﺤﻜﻤﺔ‬
‫ﺳﻠﻚ اﻷرﺿﻲ ﺗﻢ ﺗﻮﺻﻴﻠﻪ ﻣﻊ اﻷرض‬ ‫)و(‬

‫‪٤٦‬‬
‫ﺗﺎﺑﻊ ‪ -‬ﻗﺎﺋﻤﺔ ﻓﺤﻮﺻﺎت اﻟﺘﺮآﻴﺒﺎت‬

‫‪ ٦-٢١‬اﻟﺘﺸﻄﻴﺐ اﻟﻨﻬﺎﺋﻰ ﻷﻋﻤﺎل اﻟﺘﺮآﻴﺒﺎت‬


‫ﺗﻢ رﺑﺎط اﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻣﻊ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ ﺑﺸﻜﻞ ﺣﺰﻣﺔ‬
‫)أ(‬
‫ﻣﺴﺘﺪﻳﺮة‬
‫)ب( ﺗﻢ ﻣﺮاﻋﺎة أن ﻳﻜﻮن ﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ اﻟﻤﻴﺎﻩ أﺳﻔﻞ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن واﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫ﺗﻢ ﺗﻐﻄﻴﺔ اﻟﺨﻠﻮص اﻟﻤﻮﺟﻮد ﺑﻴﻦ ﻓﺘﺤﺔ اﻟﺤﺎﺋﻂ واﻟﺤﺰﻣﺔ اﻟﻤﺴﺘﺪﻳﺮة اﻟﻤﻜﻮﻧﺔ ﻣﻦ وﺻﻼت ﻣﻮاﺳﻴﺮ اﻟﻔﺮﻳﻮن‬
‫)ج(‬
‫واﻟﻜﺎﺑﻼت اﻟﻜﻬﺮﺑﺎﺋﻴﺔ وﺧﺮﻃﻮم ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ اﻟﺘﻜﺜﻴﻒ‬
‫‪ ٧-٢١‬اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ ﺑﻌﺪ اﻧﺘﻬﺎء ﻋﻤﻠﻴﺎت اﻟﺘﺮآﻴﺒﺎت‬
‫ﺗﻢ اﺧﺘﺒﺎر ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺒﺮﻳﺪ وﺿﺒﻂ ﺷﺤﻨﺔ اﻟﻔﺮﻳﻮن‬ ‫)أ(‬
‫)ب( ﺗﻢ اﺧﺘﺒﺎر ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺪﻓﺌﺔ )ﻓﻰ ﺣﺎﻟﺔ اﻟﺪورة اﻟﻤﻌﻜﻮﺳﺔ(‬
‫ﺗﻢ اﻟﺘﺄآﺪ ﻣﻦ ﻋﺪم وﺟﻮد أﻳﺔ اهﺘﺰازات أو ﺻﻮت ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ أو اﻟﺨﺎرﺟﻴﺔ أﺛﻨﺎء اﺧﺘﺒﺎر اﻟﺘﺸﻐﻴﻞ‬ ‫)ج(‬
‫ﺗﻢ ﺿﺒﻂ اﻟﻤﻮﺟﻬﺎت اﻟﺪاﺧﻠﻴﺔ ﻟﻠﻬﻮاء اﻟﻤﻜﻴﻒ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﺣﺴﺐ اﻻﺣﺘﻴﺎج‬ ‫)د(‬

‫‪ ٨-٢١‬إرﺷﺎدات ﻟﻠﻌﻤﻴﻞ‬
‫ﺗﻢ إرﺷﺎد اﻟﻌﻤﻴﻞ ﺑﺎﻟﻨﻘﺎط اﻟﺘﺎﻟﻴﺔ‬ ‫)أ(‬
‫ﻃﺮﻳﻘﺔ ﺗﺸﻐﻴﻞ وإﻳﻘﺎف ﺗﺸﻐﻴﻞ اﻟﺠﻬﺎز‪.‬‬ ‫‪-‬‬

‫ﻃﺮﻳﻘﺔ ﺗﻐﻴﻴﺮ ﻧﻈﺎم اﻟﺘﺸﻐﻴﻞ‪.‬‬ ‫‪-‬‬

‫ﻃﺮﻳﻘﺔ ﺿﺒﻂ درﺟﺎت اﻟﺤﺮارة‪.‬‬ ‫‪-‬‬

‫وﻇﺎﺋﻒ اﻟﺘﺎﻳﻤﺮ‪.‬‬ ‫‪-‬‬

‫وﻇﻴﻔﺔ اﻟﺘﻮﺟﻴﻪ اﻷوﺗﻮﻣﺎﺗﻴﻜﻰ ﻟﻠﻤﻮﺟﻪ اﻟﺨﺎرﺟﻰ اﻟﺨﺎص ﺑﺎﻟﻬﻮاء اﻟﻤﻜﻴﻒ‪.‬‬ ‫‪-‬‬

‫اﻟﻮﻇﺎﺋﻒ اﻷﺧﺮى ﻟﻮﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‪.‬‬ ‫‪-‬‬

‫ﻃﺮﻳﻘﺔ اﺳﺘﺨﺪام اﻟﻤﻮﺟﻬﺎت اﻟﺪاﺧﻠﻴﺔ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻬﻮاء اﻟﻤﻜﻴﻒ‪.‬‬ ‫‪-‬‬

‫ﻃﺮﻳﻘﺔ إﺧﺮاج اﻟﻔﻠﺘﺮ وﺗﻨﻈﻴﻔﻪ ﺛﻢ إﻋﺎدة ﺗﺮآﻴﺒﻪ‪.‬‬ ‫‪-‬‬

‫)ب( ﺗﻢ إﻋﻄﺎء اﻟﻌﻤﻴﻞ آﺘﺎﻟﻮج اﻟﺘﺸﻐﻴﻞ وآﺘﺎﻟﻮج اﻟﺘﺮآﻴﺒﺎت‬

‫‪٤٧‬‬
‫‪ -٢٢‬وﻇﻴﻔﺔ اﻟﺘﺸﺨﻴﺺ اﻟﺬاﺗﻰ ﻹآﺘﺸﺎف اﻷﻋﻄﺎل‬
‫ﺷﺮح وﻇﻴﻔﺔ اﻟﺘﺸﺨﻴﺺ اﻟﺬاﺗﻰ ﻟﻸﻋﻄﺎل‪:‬‬
‫‪ -‬وﻇﻴﻔﺔ اﻟﺘﺸﺨﻴﺺ اﻟﺬاﺗﻰ ﻟﻸﻋﻄﺎل ﻣﻦ أهﻢ ﻣﻘﻮﻣﺎت ﻧﺠﺎح ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺑﺪون ﺣﺪوث أﻋﻄﺎل‪.‬‬
‫‪ -‬وﺣﺪة اﻟﺘﺤﻜﻢ اﻹﻟﻜﺘﺮوﻧﻴﺔ اﻟﻤﻮﺟﻮدة ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻣﺰودة ﺑﻮﻇﻴﻔﺔ اﻟﺘﺸﺨﻴﺺ اﻟﺬاﺗﻰ ﻻآﺘﺸﺎف اﻷﻋﻄﺎل وإﻳﻘﺎف ﺗﺸﻐﻴﻞ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬
‫أوﺗﻮﻣﺎﺗﻴﻜﻴ ًﺎ ﻋﻨﺪ ﺣﺪوث ﻋﻄﻞ‪.‬‬
‫‪ -‬وﻇﻴﻔﺔ اﻟﺘﺸﺨﻴﺺ اﻟﺬاﺗﻰ ﻟﻸﻋﻄﺎل هﺎﻣﺔ ﺟﺪًا ﻓﻰ ﺗﺤﺪﻳﺪ اﻟﺴﺒﺐ اﻟﻤﺤﺘﻤﻞ ﻟﻠﻌﻄﻞ ﻟﻔﺤﺼﻪ وإﺻﻼﺣﻪ‪.‬‬
‫ﻋﻨﺪﻣﺎ ﻳﺤﺪث ﻋﻄﻞ ﻓﺈن آﻮد اﻟﻌﻄﻞ ﻳﻈﻬﺮ ﻋﻠﻰ ﺷﺎﺷﺔ ﻟﻮﺣﺔ اﻟﺘﺤﻜﻢ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻃﺒﻘ ًﺎ ﻟﻠﺠﺪول اﻟﻤﻮﺿﺢ‪.‬‬
‫‪ ( ADJUST‬اﻟﻤﻮﺟﻮد ﻋﻠﻰ ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ وذﻟﻚ ‪:‬‬ ‫‪ ( ADJUST‬أو )‬ ‫‪ -‬ﻋﻨﺪ ﺣﺪوث ﻋﻄﻞ اﺿﻐﻂ ﻋﻠﻰ ﻣﻔﺘﺎح اﻟﻀﺒﻂ )‬
‫ﻓﺤﺺ اﻷﻋﻄﺎل ‪ P9 ، P5 ، P4 ، E6 ، E4 ، E3 ، E2 ، E1‬ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪٣٦‬‬ ‫ƒ‬
‫ﻟﺠﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻣﻮدﻳﻞ ‪٦٠ -٤٨‬‬ ‫ﻓﺤﺺ اﻷﻋﻄﺎل ‪P9 ، P5 ، P4 ، E6 ، E3 ، E2 ، E1‬‬ ‫ƒ‬

‫ﻜﻭﺩ ﺍﻟﻌﻁل ﻴﻅﻬﺭﻋﻠﻰ ﺸﺎﺸﺔ‬


‫ﻟﻭﺤﺔ ﺘﺸﻐﻴل ﺍﻟﻭﺤﺩﺓ ﺍﻟﺩﺨﻠﻴﺔ‬

‫اﻟﺤﻞ‬ ‫ﻧﻮع اﻟﻌﻄﻞ‬ ‫آﻮد اﻟﻌﻄﻞ‬ ‫ﻣﺴﻠﺴﻞ‬


‫ﻋﻄﻞ ﻓﻲ ﺳﻴﻨﺴﻮر اﻟﻬﻮاء اﻟﺮاﺟﻊ إﻟﻰ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫أﺧﺘﺒﺮ اﻟﺴﻴﻨﺴﻮر ﺛﻢ ﻗﻢ ﺑﺘﻐﻴﻴﺮﻩ إذا آﺎن ﺗﺎﻟﻔﺎ‬ ‫‪E1‬‬ ‫‪١‬‬
‫) ﻓﺘﺢ آﻬﺮﺑﺎﺋﻲ أو ﻗﺼﺮ آﻬﺮﺑﺎﺋﻲ (‬
‫ﻋﻄﻞ ﻓﻲ ﺳﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‬
‫أﺧﺘﺒﺮ اﻟﺴﻴﻨﺴﻮر ﺛﻢ ﻗﻢ ﺑﺘﻐﻴﻴﺮﻩ إذا آﺎن ﺗﺎﻟﻔﺎ‬ ‫‪E2‬‬ ‫‪٢‬‬
‫) ﻓﺘﺢ آﻬﺮﺑﺎﺋﻲ أو ﻗﺼﺮ آﻬﺮﺑﺎﺋﻲ (‬
‫ﻋﻄﻞ ﻓﻲ ﺳﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫أﺧﺘﺒﺮ اﻟﺴﻴﻨﺴﻮر ﺛﻢ ﻗﻢ ﺑﺘﻐﻴﻴﺮﻩ إذا آﺎن ﺗﺎﻟﻔﺎ‬ ‫‪E3‬‬ ‫‪٣‬‬
‫) ﻓﺘﺢ آﻬﺮﺑﺎﺋﻲ أو ﻗﺼﺮ آﻬﺮﺑﺎﺋﻲ (‬
‫ﻋﻄﻞ ﻓﻲ ﺳﻴﻨﺴﻮر اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫أﺧﺘﺒﺮ اﻟﺴﻴﻨﺴﻮر ﺛﻢ ﻗﻢ ﺑﺘﻐﻴﻴﺮﻩ إذا آﺎن ﺗﺎﻟﻔﺎ‬ ‫‪E4‬‬ ‫‪٤‬‬
‫) ﻓﺘﺢ آﻬﺮﺑﺎﺋﻲ أو ﻗﺼﺮ آﻬﺮﺑﺎﺋﻲ (‬
‫وﻇﻴﻔﺔ اﻟﺤﻤﺎﻳﺔ اﻟﺨﺎﺻﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ واﻟﺘﻲ ﺗﻌﻤﻞ‬
‫اﺗﺼﻞ ﺑﻜﺎرﻳﻴﺮ أو أﺣﺪ ﻣﻮزﻋﻴﻬﺎ اﻟﻤﻌﺘﻤﺪﻳﻦ ﻟﻌﻼج‬ ‫ﻋﻨﺪ ﺣﺪوث أﺣﺪ اﻷﻋﻄﺎل اﻟﺘﻲ ﺗﻈﻬﺮ أﻳﻀ ًﺎ ﻣﻦ ﺧﻼل‬ ‫‪E6‬‬ ‫‪٥‬‬
‫اﻟﻌﻄﻞ وإﺻﻼﺣﻪ‬ ‫اﻟﻠﻤﺒﺎت اﻟﻤﻮﺟﻮدة ﺑﺎﻟﻮﺣﺪة اﻹﻟﻜﺘﺮوﻧﻴﺔ ﺑﺎﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ‬
‫آﺎﻟﺘﺎﻟﻲ ‪:‬‬
‫‪LED LED LED‬‬
‫‪3‬‬ ‫‪2‬‬ ‫‪1‬‬
‫اﻟﻌﻄﻞ‬
‫‪on‬‬ ‫‪off‬‬ ‫‪off‬‬ ‫ﻻﻳﻮﺟﺪ ﻋﻄﻞ‬
‫‪on‬‬ ‫‪off‬‬ ‫‪on‬‬ ‫ﻋﻜﺲ أﺣﺪ اﻟﻔﺎزات‬
‫‪on‬‬ ‫‪on‬‬ ‫‪off‬‬ ‫اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻲ أآﺒﺮ ﻣﻦ اﻟﻼزم‬
‫‪on‬‬ ‫‪on‬‬ ‫‪on‬‬ ‫ﺳﻘﻮط أﺣﺪ اﻟﻔﺎزات‬
‫ﻗﻢ ﺑﻌﻼج اﻟﺘﻨﻔﻴﺲ‬ ‫ﺗﻨﻔﻴﺲ ﺑﺪاﺋﺮة اﻟﻔﺮﻳﻮن ﻓﻰ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ‬ ‫‪EC‬‬ ‫‪٦‬‬
‫اﻓﺼﻞ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻲ ﻋﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺛﻢ‬
‫درﺟﺔ ﺣﺮارة اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﻣﻨﺨﻔﻀﺔ‬
‫ﻗﻢ ﺑﺘﻨﻈﻴﻒ ﻓﻼﺗﺮ اﻟﻬﻮاء ﺛﻢ أﻋﺪ ﺗﺸﻐﻴﻞ ﺟﻬﺎز‬
‫ﺟﺪا أو ﻣﺮﺗﻔﻌﺔ ﺟﺪا وﻋﻨﺪﺋﺬ ﺗﻌﻤﻞ وﻇﻴﻔﺔ اﻟﺤﻤﺎﻳﺔ اﻟﺘﻲ‬ ‫‪P4‬‬ ‫‪٧‬‬
‫اﻟﺘﻜﻴﻴﻒ ﻓﺈذا اﺳﺘﻤﺮ اﻟﻌﻄﻞ اﺗﺼﻞ ﺑﻜﺎرﻳﻴﺮ أو أﺣﺪ‬
‫ﺗﻘﻮم أوﺗﻮﻣﺎﺗﻴﻜﻴ ًﺎ ﺑﺈﻳﻘﺎف ﺗﺸﻐﻴﻞ اﻟﻀﺎﻏﻂ‬
‫ﻣﻮزﻋﻴﻬﺎ اﻟﻤﻌﺘﻤﺪﻳﻦ‬
‫اﻓﺼﻞ اﻟﻤﺼﺪر اﻟﻜﻬﺮﺑﺎﺋﻲ ﻋﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﺛﻢ‬
‫درﺟﺔ ﺣﺮارة اﻟﻤﺒﺎدل اﻟﺤﺮاري ﻟﻠﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻣﺮﺗﻔﻌﺔ‬
‫ﺗﺄآﺪ ﻣﻦ ﻋﺪم وﺟﻮد ﻋﻮاﺋﻖ أﻣﺎم اﻟﻬﻮاء اﻟﺪاﺧﻞ‬
‫ﺟﺪا وﻋﻨﺪﺋﺬ ﺗﻌﻤﻞ وﻇﻴﻔﺔ اﻟﺤﻤﺎﻳﺔ اﻟﺘﻲ ﺗﻘﻮم أوﺗﻮﻣﺎﺗﻴﻜﻴ ًﺎ‬ ‫‪P5‬‬ ‫‪٨‬‬
‫إﻟﻰ اﻟﻮﺣﺪة اﻟﺨﺎرﺟﻴﺔ ﻓﺈذا اﺳﺘﻤﺮ اﻟﻌﻄﻞ اﺗﺼﻞ‬
‫ﺑﺈﻳﻘﺎف ﺗﺸﻐﻴﻞ اﻟﻀﺎﻏﻂ‬
‫ﺑﻜﺎرﻳﻴﺮ أو أﺣﺪ ﻣﻮزﻋﻴﻬﺎ اﻟﻤﻌﺘﻤﺪﻳﻦ‬
‫وﻇﻴﻔﺔ اﻟﺤﻤﺎﻳﺔ اﻟﺨﺎﺻﺔ ﺑﺈذاﺑﺔ اﻟﺜﻠﺞ ﻣﻦ اﻟﻤﺒﺎدل اﻟﺤﺮاري‬
‫ﻟﻠﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﺗﻌﻤﻞ أﺛﻨﺎء ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺪﻓﺌﺔ ﻋﻨﺪ‬
‫وﻇﻴﻔﺔ ﺣﻤﺎﻳﺔ ﻃﺒﻴﻌﻴﺔ‬ ‫درﺟﺔ ﺣﺮارة هﻮاء ﺧﺎرﺟﻲ ﻣﻨﺨﻔﻀﺔ‬ ‫‪P9‬‬ ‫‪٩‬‬
‫أو وﻇﻴﻔﺔ اﻟﺤﻤﺎﻳﺔ اﻟﺨﺎﺻﺔ ﺑﻤﻨﻊ ﺧﺮوج هﻮاء ﺑﺎرد أﺛﻨﺎء‬
‫ﺑﺪء ﺗﺸﻐﻴﻞ ﻋﻤﻠﻴﺔ اﻟﺘﺪﻓﺌﺔ‬
‫ﻣﻼﺣﻈﺎت‬
‫ﻋﻨﺪ إﺻﻼح اﻟﻌﻄﻞ ﻳﺠﺐ ﻓﺼﻞ ﻣﺼﺪر اﻟﺘﻴﺎر اﻟﻜﻬﺮﺑﺎﺋﻰ ﻋﻦ ﺟﻬﺎز اﻟﺘﻜﻴﻴﻒ ﻋﻦ ﻃﺮﻳﻖ ﺗﺤﺮﻳﻚ ﻣﻔﺘﺎح اﻟﺘﺸﻐﻴﻞ إﻟﻰ وﺿﻊ إﻳﻘﺎف )‪.(OFF‬‬ ‫‪-١‬‬
‫ﺑﻌﺪ إﺻﻼح اﻟﻌﻄﻞ ﻳﺠﺐ ﺗﺤﺮﻳﻚ اﻟﺘﺸﻐﺒﻞ إﻟﻰ وﺿﻊ ﺗﺸﻐﻴﻞ )‪ (ON‬ﺛﻢ ﻳﺘﻢ ﺗﺸﻐﻴﻞ اﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ ﺑﺎﺳﺘﺨﺪام وﺣﺪة اﻟﺘﺤﻜﻢ اﻟﻼﺳﻠﻜﻴﺔ‬ ‫‪-٢‬‬
‫أو ﺑﺈﺳﺘﺨﺪام ﻟﻮﺣﺔ اﻟﺘﺸﻐﻴﻞ اﻟﻤﻮﺟﻮدة ﺑﺎﻟﻮﺣﺪة اﻟﺪاﺧﻠﻴﺔ‪.‬‬
‫‪٤٨‬‬
www.miraco.com.eg